Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
JAMA Otolaryngol Head Neck Surg ; 150(4): 318-326, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38451508

RESUMO

Importance: Image guidance is an important adjunct for endoscopic sinus and skull base surgery. However, current systems require bulky external tracking equipment, and their use can interrupt efficient surgical workflow. Objective: To evaluate a trackerless surgical navigation system using 3-dimensional (3D) endoscopy and simultaneous localization and mapping (SLAM) algorithms in the anterior skull base. Design, Setting, and Participants: This interventional deceased donor cohort study and retrospective clinical case study was conducted at a tertiary academic medical center with human deceased donor specimens and a patient with anterior skull base pathology. Exposures: Participants underwent endoscopic endonasal transsphenoidal dissection and surface model reconstruction from stereoscopic video with registration to volumetric models segmented from computed tomography (CT) and magnetic resonance imaging. Main Outcomes and Measures: To assess the fidelity of surface model reconstruction and accuracy of surgical navigation and surface-CT model coregistration, 3 metrics were calculated: reconstruction error, registration error, and localization error. Results: In deceased donor models (n = 9), high-fidelity surface models of the posterior wall of the sphenoid sinus were reconstructed from stereoscopic video and coregistered to corresponding volumetric CT models. The mean (SD; range) reconstruction, registration, and localization errors were 0.60 (0.24; 0.36-0.93), 1.11 (0.49; 0.71-1.56) and 1.01 (0.17; 0.78-1.25) mm, respectively. In a clinical case study of a patient who underwent a 3D endoscopic endonasal transsphenoidal resection of a tubercular meningioma, a high-fidelity surface model of the posterior wall of the sphenoid was reconstructed from intraoperative stereoscopic video and coregistered to a volumetric preoperative fused CT magnetic resonance imaging model with a root-mean-square error of 1.38 mm. Conclusions and Relevance: The results of this study suggest that SLAM algorithm-based endoscopic endonasal surgery navigation is a novel, accurate, and trackerless approach to surgical navigation that uses 3D endoscopy and SLAM-based algorithms in lieu of conventional optical or electromagnetic tracking. While multiple challenges remain before clinical readiness, a SLAM algorithm-based endoscopic endonasal surgery navigation system has the potential to improve surgical efficiency, economy of motion, and safety.


Assuntos
Endoscopia , Cirurgia Assistida por Computador , Humanos , Estudos de Coortes , Estudos Retrospectivos , Endoscopia/métodos , Cirurgia Assistida por Computador/métodos , Base do Crânio/diagnóstico por imagem , Base do Crânio/cirurgia
2.
IEEE Trans Image Process ; 31: 706-720, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34914589

RESUMO

This paper proposes a novel method for removing image feature mismatches in real-time that can handle both rigid and smooth deforming environments. Image distortion, parallax and object deformation may cause the pixel coordinates of feature matches to have non-rigid deformations, which cannot be represented using a single analytical rigid transformation. To solve this problem, we propose an algorithm based on the re-weighting and 1-point RANSAC strategy (R1P-RNSC), which operates under the assumption that a non-rigid deformation can be approximately represented by multiple rigid transformations. R1P-RNSC is fast but suffers from the drawback that local smoothing information cannot be considered, thus limiting its accuracy. To solve this problem, we propose a non-parametric algorithm based on the expectation-maximization algorithm and the dual quaternion-based representation (EMDQ). EMDQ generates dense and smooth deformation fields by interpolating among the feature matches, simultaneously removing mismatches that are inconsistent with the deformation field. It relies on the rigid transformations obtained by R1P-RNSC to improve its accuracy. The experimental results demonstrate that EMDQ has superior accuracy compared to other state-of-the-art mismatch removal methods. The ability to build correspondences for all image pixels using the dense deformation field is another contribution of this paper.

3.
Artigo em Inglês | MEDLINE | ID: mdl-35664445

RESUMO

We propose a novel stereo laparoscopy video-based non-rigid SLAM method called EMDQ-SLAM, which can incrementally reconstruct thee-dimensional (3D) models of soft tissue surfaces in real-time and preserve high-resolution color textures. EMDQ-SLAM uses the expectation maximization and dual quaternion (EMDQ) algorithm combined with SURF features to track the camera motion and estimate tissue deformation between video frames. To overcome the problem of accumulative errors over time, we have integrated a g2o-based graph optimization method that combines the EMDQ mismatch removal and as-rigid-as-possible (ARAP) smoothing methods. Finally, the multi-band blending (MBB) algorithm has been used to obtain high resolution color textures with real-time performance. Experimental results demonstrate that our method outperforms two state-of-the-art non-rigid SLAM methods: MISSLAM and DefSLAM. Quantitative evaluation shows an average error in the range of 0.8-2.2 mm for different cases.

4.
IEEE Trans Med Imaging ; 40(6): 1726-1736, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33690113

RESUMO

The ability to extend the field of view of laparoscopy images can help the surgeons to obtain a better understanding of the anatomical context. However, due to tissue deformation, complex camera motion and significant three-dimensional (3D) anatomical surface, image pixels may have non-rigid deformation and traditional mosaicking methods cannot work robustly for laparoscopy images in real-time. To solve this problem, a novel two-dimensional (2D) non-rigid simultaneous localization and mapping (SLAM) system is proposed in this paper, which is able to compensate for the deformation of pixels and perform image mosaicking in real-time. The key algorithm of this 2D non-rigid SLAM system is the expectation maximization and dual quaternion (EMDQ) algorithm, which can generate smooth and dense deformation field from sparse and noisy image feature matches in real-time. An uncertainty-based loop closing method has been proposed to reduce the accumulative errors. To achieve real-time performance, both CPU and GPU parallel computation technologies are used for dense mosaicking of all pixels. Experimental results on in vivo and synthetic data demonstrate the feasibility and accuracy of our non-rigid mosaicking method.


Assuntos
Imageamento Tridimensional , Laparoscopia , Algoritmos , Movimento (Física)
5.
IEEE Trans Med Imaging ; 39(2): 400-412, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31283478

RESUMO

We propose an approach to reconstruct dense three-dimensional (3D) model of tissue surface from stereo optical videos in real-time, the basic idea of which is to first extract 3D information from video frames by using stereo matching, and then to mosaic the reconstructed 3D models. To handle the common low-texture regions on tissue surfaces, we propose effective post-processing steps for the local stereo matching method to enlarge the radius of constraint, which include outliers removal, hole filling, and smoothing. Since the tissue models obtained by stereo matching are limited to the field of view of the imaging modality, we propose a model mosaicking method by using a novel feature-based simultaneously localization and mapping (SLAM) method to align the models. Low-texture regions and the varying illumination condition may lead to a large percentage of feature matching outliers. To solve this problem, we propose several algorithms to improve the robustness of the SLAM, which mainly include 1) a histogram voting-based method to roughly select possible inliers from the feature matching results; 2) a novel 1-point RANSAC-based [Formula: see text] algorithm called as DynamicR1PP [Formula: see text] to track the camera motion; and 3) a GPU-based iterative closest points (ICP) and bundle adjustment (BA) method to refine the camera motion estimation results. Experimental results on ex- and in vivo data showed that the reconstructed 3D models have high-resolution texture with an accuracy error of less than 2 mm. Most algorithms are highly parallelized for GPU computation, and the average runtime for processing one key frame is 76.3 ms on stereo images with 960×540 resolution.


Assuntos
Algoritmos , Imageamento Tridimensional/métodos , Cirurgia Assistida por Computador/métodos , Animais , Humanos , Rim/diagnóstico por imagem , Rim/cirurgia , Fígado/diagnóstico por imagem , Fígado/cirurgia , Neoplasias/diagnóstico por imagem , Neoplasias/cirurgia , Imagens de Fantasmas , Procedimentos Cirúrgicos Robóticos , Propriedades de Superfície , Suínos
6.
Med Image Comput Comput Assist Interv ; 11764: 339-347, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32391525

RESUMO

Tissue deformation during the surgery may significantly decrease the accuracy of surgical navigation systems. In this paper, we propose an approach to estimate the deformation of tissue surface from stereo videos in real-time, which is capable of handling occlusion, smooth surface and fast deformation. We first use a stereo matching method to extract depth information from stereo video frames and generate the tissue template, and then estimate the deformation of the obtained template by minimizing ICP, ORB feature matching and as-rigid-as-possible (ARAP) costs. The main novelties are twofold: (1) Due to non-rigid deformation, feature matching outliers are difficult to be removed by traditional RANSAC methods; therefore we propose a novel 1-point RANSAC and reweighting method to preselect matching inliers, which handles smooth surfaces and fast deformations. (2) We propose a novel ARAP cost function based on dense connections between the control points to achieve better smoothing performance with limited number of iterations. Algorithms are designed and implemented for GPU parallel computing. Experiments on ex- and in vivo data showed that this approach works at an update rate of 15 Hz with an accuracy of less than 2.5 mm on a NVIDIA Titan X GPU.

7.
IEEE Trans Pattern Anal Mach Intell ; 41(12): 3022-3033, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31689179

RESUMO

The ability to handle outliers is essential for performing the perspective- n-point (P nP) approach in practical applications, but conventional RANSAC+P3P or P4P methods have high time complexities. We propose a fast P nP solution named R1PP nP to handle outliers by utilizing a soft re-weighting mechanism and the 1-point RANSAC scheme. We first present a P nP algorithm, which serves as the core of R1PP nP, for solving the P nP problem in outlier-free situations. The core algorithm is an optimal process minimizing an objective function conducted with a random control point. Then, to reduce the impact of outliers, we propose a reprojection error-based re-weighting method and integrate it into the core algorithm. Finally, we employ the 1-point RANSAC scheme to try different control points. Experiments with synthetic and real-world data demonstrate that R1PP nP is faster than RANSAC+P3P or P4P methods especially when the percentage of outliers is large, and is accurate. Besides, comparisons with outlier-free synthetic data show that R1PP nP is among the most accurate and fast P nP solutions, which usually serve as the final refinement step of RANSAC+P3P or P4P. Compared with REPP nP, which is the state-of-the-art P nP algorithm with an explicit outliers-handling mechanism, R1PP nP is slower but does not suffer from the percentage of outliers limitation as REPP nP.

8.
Int J Comput Assist Radiol Surg ; 13(12): 1871-1880, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30097956

RESUMO

PURPOSE: Matching points that are derived from features or landmarks in image data is a key step in some medical imaging applications. Since most robust point matching algorithms claim to be able to deal with outliers, users may place high confidence in the matching result and use it without further examination. However, for tasks such as feature-based registration in image-guided neurosurgery, even a few mismatches, in the form of invalid displacement vectors, could cause serious consequences. As a result, having an effective tool by which operators can manually screen all matches for outliers could substantially benefit the outcome of those applications. METHODS: We introduce a novel variogram-based outlier screening method for vectors. The variogram is a powerful geostatistical tool for characterizing the spatial dependence of stochastic processes. Since the spatial correlation of invalid displacement vectors, which are considered as vector outliers, tends to behave differently than normal displacement vectors, they can be efficiently identified on the variogram. RESULTS: We validate the proposed method on 9 sets of clinically acquired ultrasound data. In the experiment, potential outliers are flagged on the variogram by one operator and further evaluated by 8 experienced medical imaging researchers. The matching quality of those potential outliers is approximately 1.5 lower, on a scale from 1 (bad) to 5 (good), than valid displacement vectors. CONCLUSION: The variogram is a simple yet informative tool. While being used extensively in geostatistical analysis, it has not received enough attention in the medical imaging field. We believe there is a good deal of potential for clinically applying the proposed outlier screening method. By way of this paper, we also expect researchers to find variogram useful in other medical applications that involve motion vectors analyses.


Assuntos
Algoritmos , Interpretação de Imagem Assistida por Computador , Procedimentos Neurocirúrgicos/métodos , Cirurgia Assistida por Computador/métodos , Humanos
9.
IEEE Trans Vis Comput Graph ; 23(2): 1014-1028, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-26863663

RESUMO

In clinical cardiology, both anatomy and physiology are needed to diagnose cardiac pathologies. CT imaging and computer simulations provide valuable and complementary data for this purpose. However, it remains challenging to gain useful information from the large amount of high-dimensional diverse data. The current tools are not adequately integrated to visualize anatomic and physiologic data from a complete yet focused perspective. We introduce a new computer-aided diagnosis framework, which allows for comprehensive modeling and visualization of cardiac anatomy and physiology from CT imaging data and computer simulations, with a primary focus on ischemic heart disease. The following visual information is presented: (1) Anatomy from CT imaging: geometric modeling and visualization of cardiac anatomy, including four heart chambers, left and right ventricular outflow tracts, and coronary arteries; (2) Function from CT imaging: motion modeling, strain calculation, and visualization of four heart chambers; (3) Physiology from CT imaging: quantification and visualization of myocardial perfusion and contextual integration with coronary artery anatomy; (4) Physiology from computer simulation: computation and visualization of hemodynamics (e.g., coronary blood velocity, pressure, shear stress, and fluid forces on the vessel wall). Substantially, feedback from cardiologists have confirmed the practical utility of integrating these features for the purpose of computer-aided diagnosis of ischemic heart disease.


Assuntos
Técnicas de Imagem Cardíaca/métodos , Simulação por Computador , Interpretação de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Gráficos por Computador , Vasos Coronários/diagnóstico por imagem , Humanos , Modelos Cardiovasculares , Isquemia Miocárdica/diagnóstico por imagem
10.
Comput Med Imaging Graph ; 53: 43-53, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27490317

RESUMO

Image-based simulation of blood flow using computational fluid dynamics has been shown to play an important role in the diagnosis of ischemic coronary artery disease. Accurate extraction of complex coronary artery structures in a watertight geometry is a prerequisite, but manual segmentation is both tedious and subjective. Several semi- and fully automated coronary artery extraction approaches have been developed but have faced several challenges. Conventional voxel-based methods allow for watertight segmentation but are slow and difficult to incorporate expert knowledge. Machine learning based methods are relatively fast and capture rich information embedded in manual annotations. Although sufficient for visualization and analysis of coronary anatomy, these methods cannot be used directly for blood flow simulation if the coronary vasculature is represented as a loose combination of tubular structures and the bifurcation geometry is improperly modeled. In this paper, we propose a novel method to extract branching coronary arteries from CT imaging with a focus on explicit bifurcation modeling and application of machine learning. A bifurcation lumen is firstly modeled by generating the convex hull to join tubular vessel branches. Guided by the pre-determined centerline, machine learning based segmentation is performed to adapt the bifurcation lumen model to target vessel boundaries and smoothed by subdivision surfaces. Our experiments show the constructed coronary artery geometry from CT imaging is accurate by comparing results against the manually annotated ground-truths, and can be directly applied to coronary blood flow simulation.


Assuntos
Vasos Coronários , Hemodinâmica , Algoritmos , Velocidade do Fluxo Sanguíneo , Simulação por Computador , Doença da Artéria Coronariana/diagnóstico , Humanos , Imageamento Tridimensional , Tomografia Computadorizada por Raios X
11.
IEEE Trans Image Process ; 23(8): 3468-77, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24951692

RESUMO

Pose estimation from points with unknown correspondences currently is still a difficult problem in the field of computer vision. To solve this problem, the SoftSI algorithm is proposed, which can simultaneously obtain pose and correspondences. The SoftSI algorithm is based on the combination of the proposed PnP algorithm (the SI algorithm) and two singular value decomposition (SVD)-based shape description theorems. Other main contributions of this paper are: 1) two SVD-based shape description theorems are proposed; 2) by analyzing the calculation process of the SI algorithm, the method to avoid pose ambiguity is proposed; and 3) an acceleration method to quickly eliminate bad initial values for the SoftSI algorithm is proposed. The simulation results show that the SI algorithm is accurate while the SoftSI algorithm is fast, robust to noise, and has large convergence radius.


Assuntos
Algoritmos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Reconhecimento Automatizado de Padrão/métodos , Fotografação/métodos , Simulação por Computador , Aumento da Imagem/métodos , Modelos Estatísticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA