Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Radiother Oncol ; 83(1): 42-8, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17343940

RESUMO

PURPOSE: To evaluate the image quality of retrospectively attenuation corrected Positron Emission Tomography (PET) scans used for gross tumor volume (GTV) delineation in lung cancer patients. MATERIALS AND METHODS: Data of 13 lymph node positive lung cancer patients were acquired on separate CT and PET scanners under free breathing conditions (for radiotherapy planning). First we determined a protocol for CT/PET registration. Second, we compared the image quality of attenuation-corrected PET images using positron transmission images and CT images, in terms of signal-to-noise ratio (SNR) and lesion-to-background ratio (contrast). RESULTS: The largest differences between manual and automatic CT/PET registration were found in the anterior-posterior direction with a mean of 1.8 mm (SD 1.0 mm). Differences in rotations were always smaller than 1.0 degrees . The attenuation-corrected images using CT showed a larger SNR (mean 30%, SD 17%) and larger contrast (mean 14.0%, SD 8.5%) compared to attenuation-corrected images using positron transmission. For lymph nodes, the mean contrast was 16% (SD 6.4%) larger. CONCLUSIONS: This study demonstrated that attenuation correction based on CT provides a better image quality for GTV delineation than when using positron transmission for attenuation correction. Retrospective attenuation correction of PET scans based on registered CT is a good alternative for a dedicated PET/CT scanner if a free-breathing CT is available, e.g., for radiotherapy planning, and allows the use of CT with diagnostic quality for attenuation correction.


Assuntos
Processamento de Imagem Assistida por Computador , Neoplasias Pulmonares/radioterapia , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Idoso , Feminino , Humanos , Aumento da Imagem , Neoplasias Pulmonares/diagnóstico por imagem , Metástase Linfática , Masculino , Pessoa de Meia-Idade , Respiração
2.
Med Phys ; 34(5): 1647-54, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17555246

RESUMO

The gamma-evaluation method is a tool by which dose distributions can be compared in a quantitative manner combining dose-difference and distance-to-agreement criteria. Since its introduction, the gamma evaluation has been used in many studies and is on the verge of becoming the preferred dose distribution comparison method, particularly for intensity-modulated radiation therapy (IMRT) verification. One major disadvantage, however, is its long computation time, which especially applies to the comparison of three-dimensional (3D) dose distributions. We present a fast algorithm for a full 3D gamma evaluation at high resolution. Both the reference and evaluated dose distributions are first resampled on the same grid. For each point of the reference dose distribution, the algorithm searches for the best point of agreement according to the gamma method in the evaluated dose distribution, which can be done at a subvoxel resolution. Speed, computer memory efficiency, and high spatial resolution are achieved by searching around each reference point with increasing distance in a sphere, which has a radius of a chosen maximum search distance and is interpolated "on-the-fly" at a chosen sample step size. The smaller the sample step size and the larger the differences between the dose distributions, the longer the gamma evaluation takes. With decreasing sample step size, statistical measures of the 3D gamma distribution converge. Two clinical examples were investigated using 3% of the prescribed dose as dose-difference and 0.3 cm as distance-to-agreement criteria. For 0.2 cm grid spacing, the change in gamma indices was negligible below a sample step size of 0.02 cm. Comparing the full 3D gamma evaluation and slice-by-slice 2D gamma evaluations ("2.5D") for these clinical examples, the gamma indices improved by searching in full 3D space, with the average gamma index decreasing by at least 8%.


Assuntos
Algoritmos , Raios gama/uso terapêutico , Neoplasias Pulmonares/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Simulação por Computador , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Dosagem Radioterapêutica , Tomografia Computadorizada por Raios X
3.
Int J Radiat Oncol Biol Phys ; 64(2): 435-48, 2006 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-16198064

RESUMO

PURPOSE: Target delineation using only CT information introduces large geometric uncertainties in radiotherapy for lung cancer. Therefore, a reduction of the delineation variability is needed. The impact of including a matched CT scan with 2-[18F]fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET) and adaptation of the delineation protocol and software on target delineation in lung cancer was evaluated in an extensive multi-institutional setting and compared with the delineations using CT only. METHODS AND MATERIALS: The study was separated into two phases. For the first phase, 11 radiation oncologists (observers) delineated the gross tumor volume (GTV), including the pathologic lymph nodes of 22 lung cancer patients (Stages I-IIIB) on CT only. For the second phase (1 year later), the same radiation oncologists delineated the GTV of the same 22 patients on a matched CT-FDG-PET scan using an adapted delineation protocol and software (according to the results of the first phase). All delineated volumes were analyzed in detail. The observer variation was computed in three dimensions by measuring the distance between the median GTV surface and each individual GTV. The variation in distance of all radiation oncologists was expressed as a standard deviation. The observer variation was evaluated for anatomic regions (lung, mediastinum, chest wall, atelectasis, and lymph nodes) and interpretation regions (agreement and disagreement; i.e., >80% vs. <80% of the radiation oncologists delineated the same structure, respectively). All radiation oncologist-computer interactions were recorded and analyzed with a tool called "Big Brother." RESULTS: The overall three-dimensional observer variation was reduced from 1.0 cm (SD) for the first phase (CT only) to 0.4 cm (SD) for the second phase (matched CT-FDG-PET). The largest reduction in the observer variation was seen in the atelectasis region (SD 1.9 cm reduced to 0.5 cm). The mean ratio between the common and encompassing volume was 0.17 and 0.29 for the first and second phases, respectively. For the first phase, the common volume was 0 in 4 patients (i.e., no common point for all GTVs). In the second phase, the common volume was always >0. For all anatomic regions, the interpretation differences among the radiation oncologists were reduced. The amount of disagreement was 45% and 18% for the first and second phase, respectively. Furthermore, the mean delineation time (12 vs. 16 min, p<0.001) and mean number of corrections (25 vs. 39, p<0.001) were reduced in the second phase compared with the first phase. CONCLUSION: For high-precision radiotherapy, the delineation of lung target volumes using only CT introduces too great a variability among radiation oncologists. Implementing matched CT-FDG-PET and adapted delineation protocol and software reduced observer variation in lung cancer delineation significantly with respect to CT only. However, the remaining observer variation was still large compared with other geometric uncertainties (setup variation and organ motion).


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Variações Dependentes do Observador , Tomografia Computadorizada de Emissão/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Diagnóstico por Computador , Feminino , Fluordesoxiglucose F18/uso terapêutico , Humanos , Pulmão/diagnóstico por imagem , Linfonodos/diagnóstico por imagem , Masculino , Mediastino/diagnóstico por imagem , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos/uso terapêutico , Parede Torácica/diagnóstico por imagem
4.
Int J Radiat Oncol Biol Phys ; 63(4): 975-84, 2005 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-16253772

RESUMO

PURPOSE: Previously, we developed an automatic three-dimensional gray-value registration (GR) method for fast prostate localization that could be used during online or offline image-guided radiotherapy. The method was tested on conventional computed tomography (CT) scans. In this study, the performance of the algorithm to localize the prostate on cone-beam CT (CBCT) scans acquired on the treatment machine was evaluated. METHODS AND MATERIALS: Five to 17 CBCT scans of 32 prostate cancer patients (332 scans in total) were used. For 18 patients (190 CBCT scans), the CBCT scans were acquired with a collimated field of view (FOV) (craniocaudal). This procedure improved the image quality considerably. The prostate (i.e., prostate plus seminal vesicles) in each CBCT scan was registered to the prostate in the planning CT scan by automatic 3D gray-value registration (normal GR) starting from a registration on the bony anatomy. When these failed, registrations were repeated with a fixed rotation point locked at the prostate apex (fixed apex GR). Registrations were visually assessed in 3D by one observer with the help of an expansion (by 3.6 mm) of the delineated prostate contours of the planning CT scan. The percentage of successfully registered cases was determined from the combined normal and fixed apex GR assessment results. The error in gray-value registration for both registration methods was determined from the position of one clearly defined calcification in the prostate gland (9 patients, 71 successful registrations). RESULTS: The percentage of successfully registered CBCT scans that were acquired with a collimated FOV was about 10% higher than for CBCT scans that were acquired with an uncollimated FOV. For CBCT scans that were acquired with a collimated FOV, the percentage of successfully registered cases improved from 65%, when only normal GR was applied, to 83% when the results of normal and fixed apex GR were combined. Gray-value registration mainly failed (or registrations were difficult to assess) because of streaks in the CBCT scans caused by moving gas pockets in the rectum during CBCT image acquisition (i.e., intrafraction motion). The error in gray-value registration along the left-right, craniocaudal, and anteroposterior axes was 1.0, 2.4, and 2.3 mm (1 SD) for normal GR, and 1.0, 2.0, and 1.7 mm (1 SD) for fixed apex GR. The systematic and random components of these SDs contributed approximately equally to these SDs, for both registration methods. CONCLUSIONS: The feasibility of automatic prostate localization on CBCT scans acquired on the treatment machine using an adaptation of the previously developed three-dimensional gray-value registration algorithm, has been validated in this study. Collimating the FOV during CBCT image acquisition improved the CBCT image quality considerably. Artifacts in the CBCT images caused by large moving gas pockets during CBCT image acquisition were the main cause for unsuccessful registration. From this study, we can conclude that CBCT scans are suitable for online and offline position verification of the prostate, as long as the amount of nonstationary gas is limited.


Assuntos
Algoritmos , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Previsões , Humanos , Masculino , Movimento , Neoplasias da Próstata/radioterapia , Radioterapia Assistida por Computador
5.
Int J Radiat Oncol Biol Phys ; 61(1): 228-38, 2005 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-15629616

RESUMO

PURPOSE: The prostate is known to translate and rotate under influence of rectal filling changes and many studies have addressed the magnitude of these motions. However, prostate shape variations also have been reported. For image-guided radiotherapy, it is essential to know the relative magnitude of translations, rotations, and shape variation so that the most appropriate correction strategy can be chosen. However, no quantitative analysis of shape variation has been performed. It is, therefore, the purpose of this article to develop a method to determine shape variation of complex organs and apply it to determine shape variation during external beam radiotherapy of a GTV (gross tumor volume) consisting of prostate and seminal vesicles. METHODS AND MATERIALS: For this study, the data of 19 patients with prostate cancer were used. Each patient received a planning computed tomography (CT) scan and 8-12 (11 on average) repeat CT scans that were made during the course of conformal radiotherapy. One observer delineated the GTV in all scans, and volume variations were measured. After matching the GTVs for each patient for translation and rotation, a coverage probability matrix was constructed and the 50% isosurface was taken to determine the average GTV surface. Perpendicular distances between the average GTV and the individual GTVs were calculated for each point of the average GTV, and their variation was expressed in terms of local standard deviation (SD). The local SDs of the shape variation of all 19 patients were mapped onto a reference case by matching and morphing of the individual average GTVs. Repeated delineation of the GTV was done for 6 patients to determine intraobserver variation. Finally, the measured shape variation was corrected for intraobserver variation to estimate the "real" shape variation. RESULTS: No significant variations in GTV volume were observed. The measured shape variation (including delineation variation) was largest at the tip of the vesicles (SD = 2.0 mm), smallest at the left and right side of the prostate (SD = 1.0 mm), and average elsewhere (SD = 1.5 mm). At the left, right, and cranial sides of the prostate, the intraobserver variation was of the same order of magnitude as the measured shape variation; elsewhere it was smaller. However, the accuracy of the estimated SD for intraobserver variation was about half of the accuracy of the estimated SD for the measured shape variation, giving an overall uncertainty of maximum 0.6 mm SD in the estimate of the "real" shape variation. The "real" shape variation was small at the left, right, and cranial side of the prostate (SD <0.5 mm) and between 0.5 mm and 1.6 mm elsewhere. CONCLUSIONS: We developed a method to quantify shape variation of organs with a complex shape and applied it to a GTV consisting of prostate and seminal vesicles. Deformation of prostate and seminal vesicles during the course of radiotherapy is small (relative to organ motion). Therefore, it is a valid approximation in image-guided radiotherapy of prostate cancer, in first order, to correct only for setup errors and organ motion. Prostate and seminal vesicles deformation can be considered as a second-order effect.


Assuntos
Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Radioterapia Conformacional , Glândulas Seminais/diagnóstico por imagem , Humanos , Masculino , Movimento , Estudos Prospectivos , Próstata/patologia , Neoplasias da Próstata/patologia , Neoplasias da Próstata/radioterapia , Radiografia , Rotação , Glândulas Seminais/patologia
6.
Radiother Oncol ; 77(2): 182-90, 2005 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16256231

RESUMO

BACKGROUND AND PURPOSE: To evaluate the process of target volume delineation in lung cancer for optimization of imaging, delineation protocol and delineation software. PATIENTS AND METHODS: Eleven radiation oncologists (observers) from five different institutions delineated the Gross Tumor Volume (GTV) including positive lymph nodes of 22 lung cancer patients (stages I-IIIB) on CT only. All radiation oncologist-computer interactions were recorded with a tool called 'Big Brother'. For each radiation oncologist and patient the following issues were analyzed: delineation time, number of delineated points and corrections, zoom levels, level and window (L/W) settings, CT slice changes, use of side windows (coronal and sagittal) and software button use. RESULTS: The mean delineation time per GTV was 16 min (SD 10 min). The mean delineation time for lymph node positive patients was on average 3 min larger (P = 0.02) than for lymph node negative patients. Many corrections (55%) were due to L/W change (e.g. delineating in mediastinum L/W and then correcting in lung L/W). For the lymph node region, a relatively large number of corrections was found (3.7 corr/cm2), indicating that it was difficult to delineate lymph nodes. For the tumor-atelectasis region, a relative small number of corrections was found (1.0 corr/cm2), indicating that including or excluding atelectasis into the GTV was a clinical decision. Inappropriate use of L/W settings was frequently found (e.g. 46% of all delineated points in the tumor-lung region were delineated in mediastinum L/W settings). Despite a large observer variation in cranial and caudal direction of 0.72 cm (1 SD), the coronal and sagittal side windows were not used in 45 and 60% of the cases, respectively. For the more difficult cases, observer variation was smaller when the coronal and sagittal side windows were used. CONCLUSIONS: With the 'Big Brother' tool a method was developed to trace the delineation process. The differences between observers concerning the delineation style were large. This study led to recommendations on how to improve delineation accuracy by adapting the delineation protocol (guidelines for L/W use) and delineation software (double window with lung and mediastinum L/W settings at the same time, enforced use of coronal and sagittal views) and including FDG-PET information (lymph nodes and atelectasis).


Assuntos
Carcinoma Pulmonar de Células não Pequenas/radioterapia , Neoplasias Pulmonares/radioterapia , Planejamento da Radioterapia Assistida por Computador/instrumentação , Idoso , Idoso de 80 Anos ou mais , Carcinoma Pulmonar de Células não Pequenas/patologia , Estudos de Coortes , Relação Dose-Resposta à Radiação , Desenho de Equipamento , Segurança de Equipamentos , Estudos de Avaliação como Assunto , Feminino , Humanos , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Variações Dependentes do Observador , Padrões de Prática Médica , Radioterapia (Especialidade)/normas , Radioterapia (Especialidade)/tendências , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Medição de Risco , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X , Resultado do Tratamento
7.
Med Phys ; 32(4): 1176-86, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15895601

RESUMO

A cone beam computed tomography (CBCT) scanner integrated with a linear accelerator is a powerful tool for image guided radiotherapy. Respiratory motion, however, induces artifacts in CBCT, while the respiratory correlated procedures, developed to reduce motion artifacts in axial and helical CT are not suitable for such CBCT scanners. We have developed an alternative respiratory correlated procedure for CBCT and evaluated its performance. This respiratory correlated CBCT procedure consists of retrospective sorting in projection space, yielding subsets of projections that each corresponds to a certain breathing phase. Subsequently, these subsets are reconstructed into a four-dimensional (4D) CBCT dataset. The breathing signal, required for respiratory correlation, was directly extracted from the 2D projection data, removing the need for an additional respiratory monitor system. Due to the reduced number of projections per phase, the contrast-to-noise ratio in a 4D scan reduced by a factor 2.6-3.7 compared to a 3D scan based on all projections. Projection data of a spherical phantom moving with a 3 and 5 s period with and without simulated breathing irregularities were acquired and reconstructed into 3D and 4D CBCT datasets. The positional deviations of the phantoms center of gravity between 4D CBCT and fluoroscopy were small: 0.13 +/- 0.09 mm for the regular motion and 0.39 +/- 0.24 mm for the irregular motion. Motion artifacts, clearly present in the 3D CBCT datasets, were substantially reduced in the 4D datasets, even in the presence of breathing irregularities, such that the shape of the moving structures could be identified more accurately. Moreover, the 4D CBCT dataset provided information on the 3D trajectory of the moving structures, absent in the 3D data. Considerable breathing irregularities, however, substantially reduces the image quality. Data presented for three different lung cancer patients were in line with the results obtained from the phantom study. In conclusion, we have successfully implemented a respiratory correlated CBCT procedure yielding a 4D dataset. With respiratory correlated CBCT on a linear accelerator, the mean position, trajectory, and shape of a moving tumor can be verified just prior to treatment. Such verification reduces respiration induced geometrical uncertainties, enabling safe delivery of 4D radiotherapy such as gated radiotherapy with small margins.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Radioterapia/métodos , Respiração , Tomografia Computadorizada Espiral/métodos , Algoritmos , Fluoroscopia , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional/métodos , Modelos Teóricos , Movimento (Física) , Movimento , Aceleradores de Partículas , Imagens de Fantasmas , Intensificação de Imagem Radiográfica , Interpretação de Imagem Radiográfica Assistida por Computador , Radiometria , Planejamento da Radioterapia Assistida por Computador , Tomografia Computadorizada por Raios X
8.
Med Phys ; 32(7): 2262-70, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16121581

RESUMO

To study dose-effect relations of prostate implants with I-125 seeds, accurate knowledge of the dose distribution in the prostate is essential. Commonly, a post-implant computed tomography (CT) scan is used to determine the geometry of the implant and to delineate the contours of the prostate. However, the delineation of the prostate on CT slices is very cumbersome due to poor contrast between the prostate capsule and surrounding tissues. Transrectal Ultrasound (TRUS) on the other hand offers good visualization of the prostate but poor visualization of the implanted seeds. The purpose of this study was to investigate the applicability of combining CT with 3D TRUS by means of image fusion. The advantage of fused TRUS-CT imaging is that both prostate contours and implanted seeds will be well visible. In our clinic, post-implant imaging was realized by simultaneously acquiring a TRUS scan and a CT scan. The TRUS transducer was inserted while the patient was on the CT couch and the CT scan was made directly after the TRUS scan, with the probe still in situ. With the TRUS transducer being visible on both TRUS and CT images, the geometrical relationship between both image sets could be defined by registration on the transducer. Having proven the applicability of simultaneous imaging, the accuracy of this registration method was investigated by additional registration on visible seeds, after preregistration on the transducer. In 4 out of 23 investigated cases an automatic grey value registration on seeds failed for each of the investigated cost functions, and in 2 cases for both cost functions, due to poor visibility of the seeds on the TRUS scan. The average deviations of the seed registration with respect to the transducer registration were negligible. However, in a few individual cases the deviations were significant and probably due to movement of the patient between TRUS and CT scan. In case of a registration on the transducer it is important to avoid patient movement in-between the TRUS and CT scan and to keep the time in-between the scans as short as possible. It can be concluded that fusion of a CT scan and a simultaneously made TRUS scan by means of a three-dimensional (3D) transducer is feasible and accurate when performing a registration on the transducer, if necessary, fine-tuned by a registration on seeds. These fused images are likely to be of great value for post-implant dose distribution evaluations.


Assuntos
Braquiterapia/métodos , Interpretação de Imagem Assistida por Computador/métodos , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/radioterapia , Radioterapia Assistida por Computador/métodos , Técnica de Subtração , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia/métodos , Algoritmos , Braquiterapia/instrumentação , Estudos de Viabilidade , Humanos , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Masculino , Planejamento da Radioterapia Assistida por Computador/métodos , Reto/diagnóstico por imagem , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
Radiother Oncol ; 62(2): 163-71, 2002 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11937243

RESUMO

PURPOSE: The main purpose of this work is to reduce the cardiac and lung dose by applying conformal tangential beam irradiation of the intact left breast with and without intensity modulation, instead of rectangular tangential treatment fields. The extension of the applicability of the maximum heart distance (MHD) to conformal tangential fields as a simple patient selection criterion, identifying patients for which rectangular and conformal tangential fields without intensity modulation will result in unacceptable normal tissue complication probability (NTCP) values for late cardiac mortality (e.g. >2%), was also investigated. MATERIALS AND METHODS: Three-dimensional treatment planning was performed for 17 left-sided breast cancer patients. Three different tangential beam techniques were compared: (1) optimized wedges without blocks, (2) optimized wedges with conformal blocks and (3) intensity modulation. Plans were evaluated using dose-volume histograms (DVHs) for the planning target volume (PTV), the heart and the lungs. NTCPs for radiation pneumonitis and late cardiac mortality were calculated using the DVH data. The MHD was measured for all rectangular (MHD(rectangular)) and conformal (MHD(conformal)) treatment plans. RESULTS: For all patients, on average, part of the PTV receiving a dose between 95 and 107% of the prescribed dose of 50Gy in 25 fractions of 2Gy was 90.8% (standard deviation (SD): 5.0%), 92.8% (SD: 3.5%) and 92.8% (SD: 3.6%) for the intensity modulation radiation therapy (IMRT), conformal and rectangular field treatment techniques, respectively. The NTCP for radiation pneumonitis was 0.3% (SD: 0.1%), 0.4% (SD: 0.4%) and 0.5% (SD: 0.6%) for the IMRT, conformal and rectangular field techniques, respectively. The NTCP for late cardiac mortality was 5.9% (SD: 2.2%) for the rectangular field technique. This value was reduced to 4.0% (SD: 2.3%) with the conformal technique. A further reduction to 2.0% (SD: 1.1%) could be accomplished with the IMRT technique. The NTCP for late cardiac mortality could be described as a second order polynomial function of the MHD. This function could be described with a high accuracy and was independent of the technique for which the MHD was determined (r(2)=0.88). In order to achieve a NTCP value for late cardiac mortality below 1, 2 or 3%, the MHD should be equal to or smaller than 11, 17 or 23 mm, respectively. If such a maximum complication probability cannot be accomplished, a treatment using the IMRT technique should be considered. CONCLUSIONS: The use of conformal tangential fields decreases the NTCP for late cardiac toxicity on average by 30% compared to using rectangular fields, while the tangential IMRT technique can further reduce this value by an additional 50%. The MHD can be used to estimate the NTCP for late cardiac mortality if rectangular or conformal tangential treatment fields are used.


Assuntos
Neoplasias da Mama/radioterapia , Cardiopatias/prevenção & controle , Pneumopatias/prevenção & controle , Lesões por Radiação/prevenção & controle , Radioterapia Conformacional/efeitos adversos , Feminino , Cardiopatias/etiologia , Humanos , Pneumopatias/etiologia , Lesões por Radiação/etiologia , Dosagem Radioterapêutica , Radioterapia Adjuvante/efeitos adversos , Radioterapia Adjuvante/métodos , Sobrevivência de Tecidos
10.
Radiother Oncol ; 62(2): 127-36, 2002 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11937239

RESUMO

BACKGROUND AND PURPOSE: To compare and evaluate intensity modulated (IMRT) and non-intensity modulated radiotherapy techniques in the treatment of the left breast and upper internal mammary lymph node chain. MATERIALS AND METHODS: The breast, upper internal mammary chain (IMC), heart and lungs were delineated on a computed tomography (CT)-scan for 12 patients. Three different treatment plans were created: (1) tangential photon fields with oblique IMC electron-photon fields with manually optimized beam weights and wedges, (2) wide split tangential photon fields with a heart block and computer optimized wedge angles, and (3) IMRT tangential photon fields. For the IMRT technique, an inverse planning program (KonRad) generated the intensity profiles and a clinical three-dimensional treatment planning system (U-MPlan) optimized the segment weights. U-MPlan calculated the dose distribution for all three techniques. The normal tissue complication probabilities (NTCPs) for the organs at risk (ORs) were calculated for comparison. RESULTS: The average root mean square deviation of the differential dose-volume histogram of the breast planning target volume was 4.6, 3.9 and 3.5% and the average mean dose to the IMC was 97.2, 108.0 and 99.6% for the oblique electron, wide split tangent and IMRT techniques, respectively. The average NTCP for the ORs (i.e. heart and lungs) were comparable between the oblique electron and IMRT techniques (or=2%) for the ORs. CONCLUSIONS: The lowest NTCP values were found with the oblique electron and the IMRT techniques. The IMRT technique had the best breast and IMC target coverage.


Assuntos
Neoplasias da Mama/radioterapia , Radioterapia de Alta Energia/métodos , Neoplasias da Mama/patologia , Feminino , Coração/efeitos da radiação , Humanos , Pulmão/efeitos da radiação , Metástase Linfática , Lesões por Radiação/etiologia , Dosagem Radioterapêutica , Radioterapia Conformacional/métodos , Sobrevivência de Tecidos/efeitos da radiação
11.
Med Phys ; 31(6): 1415-23, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15259644

RESUMO

The purpose of this study is to develop a model that quantifies in three dimensions changes in bladder shape due to changes in bladder and/or rectal volume. The new technique enables us to predict changes in bladder shape over a short period of time, based on known urinary inflow. Shortly prior to the treatment, the patient will be scanned using a cone beam CT scanner (x-ray volume imager) that is integrated with the linear accelerator. After (automated) delineation of the bladder, the model will be used to predict the short-term shape changes of the bladder for the time interval between image acquisition and dose delivery. The model was developed using multiple daily CT scans of the pelvic area of 19 patients. For each patient, the rigid bony structure in follow-up scans was matched to that of the planning CT scan, and the outer bladder and rectal wall were delineated. Each bladder wall was subdivided in 2500 domains. A fixed reference point inside the bladder was used to calculate for each bladder structure a "Mercator-like" 2D scalar map (similar to a height map of the globe), containing the distances from this reference point to each domain on the bladder wall. Subsequently, for all bladder shapes of a patient and for all domains on the wall individually, the distance to the reference point was fitted by a linear function of both bladder and rectal volume. The model uses an existing bladder structure to create a new structure via expansion (or contraction), until the expressed volume is reached. To evaluate the predictive power of the model, the jack-knife method was used. The errors in the fitting procedure depended on the part of the bladder and range from 0 to 0.5 cm (0.2 cm on average). It was found that a volume increase of 150 cc can lead to a displacement up to about 2.5 cm of the cranial part of the bladder. With the model, the uncertainty in the position of the bladder wall can be reduced down to a maximum value of about 0.5 cm in case the bladder volume increase is known. Furthermore, it was found that a change in rectal filling causes a shift of the bladder, while its shape is hardly influenced. In conclusion, we developed a model that describes the bladder shape and position as a function of the bladder volume and the rectal filling. The model accurately describes the complex shape of the bladder as it works on each domain of the bladder separately.


Assuntos
Modelos Anatômicos , Bexiga Urinária/anatomia & histologia , Fenômenos Biofísicos , Biofísica , Simulação por Computador , Humanos , Movimento , Planejamento da Radioterapia Assistida por Computador , Reto/anatomia & histologia , Tomografia Computadorizada por Raios X , Bexiga Urinária/diagnóstico por imagem , Neoplasias da Bexiga Urinária/patologia , Neoplasias da Bexiga Urinária/radioterapia
12.
Int J Radiat Oncol Biol Phys ; 82(3): e399-407, 2012 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-22284036

RESUMO

PURPOSE: To quantify the variability of diaphragm motion during free-breathing radiotherapy of lung patients and its effect on treatment margins to account for geometric uncertainties. METHODS AND MATERIALS: Thirty-three lung cancer patients were analyzed. Each patient had 5-19 cone-beam scans acquired during different treatment fractions. The craniocaudal position of the diaphragm dome on the same side as the tumor was tracked over 2 min in the projection images, because it is both easily visible and a suitable surrogate to study the variability of the tumor motion and its impact on treatment margins. Intra-acquisition, inter-acquisition, and inter-patient variability of the respiratory cycles were quantified separately, as were the probability density functions (PDFs) of the diaphragm position over each cycle, each acquisition, and each patient. Asymmetric margins were simulated using each patient PDF and compared to symmetric margins computed from a margin recipe. RESULTS: The peak-to-peak amplitude variability (1 SD) was 3.3 mm, 2.4 mm, and 6.1 mm for the intra-acquisition, inter-acquisition, and inter-patient variability, respectively. The average PDF of each cycle was similar to the sin(4) function but the PDF of each acquisition was closer to a skew-normal distribution because of the motion variability. Despite large interfraction baseline variability, the PDF of each patient was generally asymmetric with a longer end-inhale tail because the end-exhale position was more stable than the end-inhale position. The asymmetry of the PDF required asymmetric margins around the time-averaged position to account for the position uncertainty but the average difference was 1.0 mm (range, 0.0-4.4 mm) for a sharp penumbra and an idealized online setup correction protocol. CONCLUSION: The respiratory motion is more irregular during the fractions than between the fractions. The PDF of the respiratory motion is asymmetrically distributed. Both the intra-acquisition variability and the PDF asymmetry have a limited impact on dose distributions and inferred margins. The use of a margin recipe to account for respiratory motion with an estimate of the average motion amplitude was adequate in almost all patients.


Assuntos
Diafragma/diagnóstico por imagem , Expiração/fisiologia , Inalação/fisiologia , Neoplasias Pulmonares/radioterapia , Movimento , Algoritmos , Tomografia Computadorizada de Feixe Cônico , Humanos , Neoplasias Pulmonares/diagnóstico por imagem
13.
Case Rep Anesthesiol ; 2011: 878910, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22606397

RESUMO

Awake fibreoptic intubation is accepted as the gold standard for intubation of patients with an anticipated difficult airway. Radiation fibrosis may cause difficulties during the intubation procedure. We present an unusual severe case of radiation induced changes to the larynx, with limited clinical symptoms, that caused failure of the fibreoptic intubation technique. A review of the known literature on radiation fibrosis and airway management is presented.

14.
Radiother Oncol ; 97(3): 567-71, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20864198

RESUMO

This report introduces a framework for comparing radiotherapy treatment planning in multicentric in silico clinical trials. Quality assurance, data incompatibility, transfer and storage issues, and uniform analysis of results are discussed. The solutions that are given provide a useful guide for the set-up of future multicentric planning studies or public repositories of high quality data.


Assuntos
Ensaios Clínicos como Assunto , Estudos Multicêntricos como Assunto , Planejamento da Radioterapia Assistida por Computador/normas , Humanos , Garantia da Qualidade dos Cuidados de Saúde , Planejamento da Radioterapia Assistida por Computador/métodos
15.
Med Phys ; 32(7Part1): 2262-2270, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28493573

RESUMO

To study dose-effect relations of prostate implants with I-125 seeds, accurate knowledge of the dose distribution in the prostate is essential. Commonly, a post-implant computed tomography (CT) scan is used to determine the geometry of the implant and to delineate the contours of the prostate. However, the delineation of the prostate on CT slices is very cumbersome due to poor contrast between the prostate capsule and surrounding tissues. Transrectal Ultrasound (TRUS) on the other hand offers good visualization of the prostate but poor visualization of the implanted seeds. The purpose of this study was to investigate the applicability of combining CT with 3D TRUS by means of image fusion. The advantage of fused TRUS-CT imaging is that both prostate contours and implanted seeds will be well visible. In our clinic, post-implant imaging was realized by simultaneously acquiring a TRUS scan and a CT scan. The TRUS transducer was inserted while the patient was on the CT couch and the CT scan was made directly after the TRUS scan, with the probe still in situ. With the TRUS transducer being visible on both TRUS and CT images, the geometrical relationship between both image sets could be defined by registration on the transducer. Having proven the applicability of simultaneous imaging, the accuracy of this registration method was investigated by additional registration on visible seeds, after preregistration on the transducer. In 4 out of 23 investigated cases an automatic grey value registration on seeds failed for each of the investigated cost functions, and in 2 cases for both cost functions, due to poor visibility of the seeds on the TRUS scan. The average deviations of the seed registration with respect to the transducer registration were negligible. However, in a few individual cases the deviations were significant and probably due to movement of the patient between TRUS and CT scan. In case of a registration on the transducer it is important to avoid patient movement in-between the TRUS and CT scan and to keep the time in-between the scans as short as possible. It can be concluded that fusion of a CT scan and a simultaneously made TRUS scan by means of a three-dimensional (3D) transducer is feasible and accurate when performing a registration on the transducer, if necessary, fine-tuned by a registration on seeds. These fused images are likely to be of great value for post-implant dose distribution evaluations.

16.
Cancer ; 101(8): 1809-17, 2004 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-15386309

RESUMO

BACKGROUND: Concurrent chemoradiation is being used increasingly to treat patients with advanced-stage head and neck carcinoma. In the current study, a clinical nomogram was developed to predict local control and overall survival rates for individual patients who will undergo chemoradiation. METHODS: Ninety-two consecutive patients with UICC TNM Stage III/IV squamous cell carcinoma of the oral cavity, oropharynx, hypopharynx, and supraglottic larynx were treated with selective-targeted chemoradiation (acronym: RADPLAT). All living patients had a minimum follow-up of 2 years. In addition to general factors, the following parameters were analyzed in a multivariable analysis: primary tumor volume, lymph node tumor volume, total tumor volume, lowest involved neck level, comorbidity, pretreatment hemoglobin level, pretreatment weight loss, and unilateral/bilateral intraarterial infusion. Relevant factors for local control and survival were analyzed using the Cox proportional hazards model. RESULTS: At 5 years, the local control and overall survival rates for the whole group were 60% and 38%, respectively. Primary tumor volume (hazard ratio [HR], 1.03; P = 0.01) and unilateral infusion (HR, 5.05; P = 0.004) were found to influence local control significantly. Using tumor volume as a continuous variable, an adjusted risk ratio of 1.026 was found, indicating that each 1-cm(3) increase in volume was associated with a 2.6% decrease in probability of local control. Primary tumor volume (HR, 1.01; P = 0.003), comorbidity (American Society of Anesthesiologists [ASA] physical status 1 vs. > 1; HR, 2.47; P = 0.01), lowest involved neck level (HR, 3.45; P = 0.007), and pretreatment weight loss > 10% (HR, 2.04; P = 0.02) were found to be significant predictors of worse overall survival. Variables from the multivariable analysis were used to develop a nomogram capable of predicting local control and overall survival. CONCLUSIONS: Tumor volume was found to play a significant role in predicting local control and overall survival in patients with advanced-stage head and neck carcinoma who were treated with targeted chemoradiation. The nomograms may be useful for pretreatment selection of patients with advanced-stage head and neck carcinoma.


Assuntos
Carcinoma de Células Escamosas/tratamento farmacológico , Carcinoma de Células Escamosas/radioterapia , Neoplasias de Cabeça e Pescoço/tratamento farmacológico , Neoplasias de Cabeça e Pescoço/radioterapia , Adulto , Idoso , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Carcinoma de Células Escamosas/patologia , Terapia Combinada , Feminino , Seguimentos , Neoplasias de Cabeça e Pescoço/patologia , Humanos , Infusões Intra-Arteriais , Linfonodos/patologia , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Recidiva Local de Neoplasia/tratamento farmacológico , Recidiva Local de Neoplasia/patologia , Recidiva Local de Neoplasia/radioterapia , Estadiamento de Neoplasias , Probabilidade , Fatores de Risco , Taxa de Sobrevida , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA