Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 76
Filtrar
1.
Transfusion ; 63(3): 552-563, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36550639

RESUMO

BACKGROUND: Previous studies have demonstrated low first-time donor return rates (DRR) following catastrophic events. Little is known, however, about the influence of demographic factors on the DRR of first-time donors during the COVID-19 pandemic, including the unique motivation of COVID-19 convalescent plasma (CCP) donors as compared to non-CCP donors. STUDY DESIGN AND METHODS: Thirteen blood collection organizations submitted deidentified data from first-time CCP and non-CCP donors returning for regular (non-CCP) donations during the pandemic. DRR was calculated as frequencies. Demographic factors associated with returning donors: race/ethnicity, gender, and generation (Gen Z: 19-24, Millennial: 25-40, Gen X: 41-56, and Boomer: ≥57 years old), within the CCP and non-CCP first-time cohorts were compared using chi-square test at p < .05 statistical significance. RESULTS: From March 2020 through December 2021, there were a total of 44,274 first-time CCP and 980,201 first-time non-CCP donors. DRR were 14.6% (range 11.9%-43.3%) and 46.6% (range 10.0%-76.9%) for CCP and non-CCP cohorts, respectively. Age over 40 years (Gen X and Boomers), female gender, and White race were each associated with higher return in both donor cohorts (p < .001). For the non-CCP return donor cohort, the Millennial and Boomers were comparable. CONCLUSION: The findings demonstrate differences in returning donor trends between the two donor cohorts. The motivation of a first-time CCP donor may be different than that of a non-CCP donor. Further study to improve first-time donor engagement would be worthwhile to expand the donor base with a focus on blood donor diversity emphasizing engagement of underrepresented minorities and younger donors.


Assuntos
Doadores de Sangue , COVID-19 , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Pandemias , COVID-19/epidemiologia , COVID-19/terapia , Soroterapia para COVID-19 , Etnicidade
2.
Transfusion ; 63(4): 817-825, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36815517

RESUMO

BACKGROUND: The clinical significance of serologic reactivity of unidentified specificity (SRUS) in pregnancy is not clear based on available literature. The aim of this study is to determine if SRUS is associated with hemolytic disease of the fetus and newborn (HDFN). STUDY DESIGN AND METHODS: Retrospective data were collected from eight institutions over an 11-year study period (2010-2020), when available (5/8 sites). The outcome of the pregnancies with SRUS-no, mild, moderate, or severe HDFN-was determined. RESULTS: SRUS was demonstrated in 589 pregnancies. After excluding those with incomplete data, a total of 284 pregnancies were included in the primary HDFN outcome analysis. SRUS was detected in 124 (44%) pregnancies in isolation, and none were affected by HDFN. Of 41 pregnancies with SRUS and ABO incompatibility, 37 (90%) were unaffected, and 4 (10%) were associated with mild HDFN. Of 98 pregnancies with SRUS and concurrent identifiable antibody reactivity(s), 80 (81%) were unaffected, and 19 (19%) were associated with mild to severe HDFN. There was 1 case of mild HDFN and 1 case of severe HDFN in the 21 pregnancies with SRUS, ABO incompatibility, and concurrent identifiable antibody reactivity(s), and 19 (90%) were unaffected by HDFN. Among all patients with repeat testing, newly identified alloantibodies or other antibodies were identified in 63 of 212 (30%) patients. Although most were not clinically significant, on occasion SRUS preceded clinically significant antibody(s) associated with HDFN (3%, 5/188). CONCLUSION: The antenatal serologic finding of SRUS in isolation is not associated with HDFN but may precede clinically significant antibodies.


Assuntos
Antígenos de Grupos Sanguíneos , Eritroblastose Fetal , Recém-Nascido , Humanos , Feminino , Gravidez , Estudos Retrospectivos , Eritroblastose Fetal/diagnóstico , Isoanticorpos , Feto
3.
Transfusion ; 63 Suppl 3: S46-S53, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36971017

RESUMO

BACKGROUND: Questions persist about the safety of switching non-group O recipients of group O uncrossmatched red blood cells (RBC) or low titer group O whole blood (LTOWB) to ABO-identical RBCs during their resuscitation. METHODS: The database of an earlier nine-center study of transfusing incompatible plasma to trauma patients was reanalyzed. The patients were divided into three groups based on 24-h RBC transfusion: (1) group O patients who received group O RBC/LTOWB units (control group, n = 1203), (2) non-group O recipients who received only group O units (n = 646), (3) non-group O recipients who received at least one unit of group O and non-group O units (n = 562). Fixed marginal effect of receipt of non-O RBC units on 6- and 24-h and 30-day mortality was calculated. RESULTS: The non-O patients who received only group O RBCs received fewer RBC/LTOWB units and had slightly but significantly lower injury severity score compared to control group; non-group O patients who received both group O and non-O units received significantly more RBC/LTOWB units and had a slightly but significantly higher injury severity score compared to control group. In the multivariate analysis, the non-O patients who received only group O RBCs had significantly higher mortality at 6-h compared to the controls; the non-group O recipients of O and non-O RBCs did not demonstrate higher mortality. At 24-h and 30-days, there were no differences in survival between the groups. CONCLUSION: Providing non-group O RBCs to non-group O trauma patients who also received group O RBC units is not associated with higher mortality.


Assuntos
Transfusão de Sangue , Ferimentos e Lesões , Humanos , Transfusão de Eritrócitos/efeitos adversos , Ressuscitação , Eritrócitos , Sistema ABO de Grupos Sanguíneos , Ferimentos e Lesões/terapia
4.
Transfusion ; 62(2): 279-285, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34778986

RESUMO

BACKGROUND: The COVID-19 pandemic has brought tremendous challenges to the United States blood supply. Decreased collections have caused blood product shortages. The number of hospital-based donor centers (HBDCs) has decreased in the past decades, but they provide important support to their hospital systems. MATERIALS/METHODS: We identified 79 active HBDCs through an information request to the FDA. These centers were invited to participate in a survey about their activities, blood product collections, and perceived value. RESULTS: Thirty-six centers responded (46% response rate). The centers represented a wide range of states and geographic settings. Whole blood collection was most common, but some respondents also prepared specialized products such as COVID-19 convalescent plasma and pathogen-reduced platelets. Positive impacts of HBDCs included inventory availability, cost-effectiveness/savings, community outreach, supporting special patient populations, and collecting specialty products. All respondents anticipate at least stable operations, if not growth, in the future. CONCLUSION: HBDCs continue to be valuable assets in addressing emerging patient transfusion needs. Their unique offerings are tailored to the populations their hospitals support, and demonstrate the value in having the collection infrastructure in place to rapidly respond to critical shortages. This survey provides benchmark data about a broad group of HBDCs including products prepared, inventory self-sufficiency levels, and reasons for positive impact.


Assuntos
Bancos de Sangue/estatística & dados numéricos , Doadores de Sangue , Hospitais , Doadores de Sangue/provisão & distribuição , COVID-19 , Humanos , Pandemias , Estados Unidos
5.
Transfusion ; 62(2): 346-354, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34859437

RESUMO

BACKGROUND: Blood donors are a crucial element of the blood supply chain. Optimal recruitment strategies built upon the robust understanding of local donor behavior and demographics-specifically, the donor characteristics of our university-affiliated hospital-based donor center-improve outreach and retention of donors. STUDY DESIGN AND METHODS: This retrospective study analyzed blood donors' genders, ethnicities, and donation frequencies at a university-affiliated hospital-based donor center from 2014-2019, stratified into seven age cohorts. Donor ethnicity demographics were compared to the reported student, employee, and LA County population. RESULTS: Female donors outnumbered male donors in all age cohorts. The majority of donors self-identified (SI) as White (36.7%), Hispanic/Latino (21.6%), or Asian (19.1%). Older donors (age > 25) donated more frequently (4.1 vs. 2.3 donations per donor) than younger donors (age ≤ 25). Repeat donors who donated in multiple years during the study period were more likely to donate multiple times each year than those donors who only donated during 1 year. DISCUSSION: Our donor demographics more closely reflect the university student and employee demographics than LA County demographics, demonstrating the broad local efforts of recruitment by student groups and donor center recruitment staff. However, non-White populations continue to be underrepresented. The majority of donors only donated once during the study period. Recruitment strategies to increase donor engagement among underrepresented populations and increase the proportion of repeat donors are likely to prove most beneficial.


Assuntos
Doadores de Sangue , Etnicidade , Feminino , Hospitais Universitários , Humanos , Masculino , Estudos Retrospectivos , Universidades
6.
Transfusion ; 62(9): 1772-1778, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35904145

RESUMO

BACKGROUND: Institutional data on initiating and maintaining a low-titer O positive whole blood (LTOWB) inventory for the civilian trauma sector may help other institutions start a LTOWB program. This study from a level 1 trauma center with a hospital-based donor center highlights challenges faced during the collection, maintenance, and utilization of LTOWB. STUDY DESIGN AND METHODS: Male O positive donors with low (≤1:100) anti-A and anti-B antibody titers were recruited for LTOWB collection. The daily inventory goal of 4 LTOWB units was kept in the emergency department refrigerator and transfused to adult male trauma patients. Unused units older than 10 days were reprocessed into packed red blood cells. RESULTS: Of 900 donors screened, 61% qualified and 52% of eligible donors provided a collective total of 505 LTOWB units over 2.5 years. The number of collected units directly correlated with the availability of inventory; 42% of the units were transfused, 54% were reprocessed, and 4% were discarded. The inventory goal was maintained for 56% of the year 2018 and 83% of the year 2019. Over these 2 years, 52% of patients had their transfusion needs fully met, 41% had their needs partially met, and 6.5% did not have their needs met. DISCUSSION: Initial challenges to LTOWB implementation were inventory shortages, low utilization rates, and failure to meet clinical demand. Proposed solutions include allowing for a higher yet safe titer, extending shelf life, expanding the donor pool, identifying barriers to utilization, and permitting use in female trauma patients beyond childbearing age.


Assuntos
Centros de Traumatologia , Ferimentos e Lesões , Sistema ABO de Grupos Sanguíneos , Adulto , Preservação de Sangue , Transfusão de Sangue , Feminino , Humanos , Masculino , Ressuscitação , Ferimentos e Lesões/terapia
7.
Transfusion ; 62(3): 570-583, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35128658

RESUMO

BACKGROUND: COVID-19 convalescent plasma (CCP), from donors recovered from severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) infection, is one of the limited therapeutic options currently available for the treatment of critically ill patients with COVID-19. There is growing evidence that CCP may reduce viral loads and disease severity; and reduce mortality. However, concerns about the risk of transfusion-transmitted infections (TTI) and other complications associated with transfusion of plasma, remain. Amotosalen/UVA pathogen reduction treatment (A/UVA-PRT) of plasma offers a mitigation of TTI risk, and when combined with pooling has the potential to increase the diversity of the polyclonal SARS-CoV-2 neutralizing antibodies. STUDY DESIGN AND METHODS: This study assessed the impact of A/UVA-PRT on SARS-CoV-2 antibodies in 42 CCP using multiple complimentary assays including antigen binding, neutralizing, and epitope microarrays. Other mediators of CCP efficacy were also assessed. RESULTS: A/UVA-PRT did not negatively impact antibodies to SARS-CoV-2 and other viral epitopes, had no impact on neutralizing activity or other potential mediators of CCP efficacy. Finally, immune cross-reactivity with other coronavirus antigens was observed raising the potential for neutralizing activity against other emergent coronaviruses. CONCLUSION: The findings of this study support the selection of effective CCP combined with the use of A/UVA-PRT in the production of CCP for patients with COVID-19.


Assuntos
COVID-19 , Anticorpos Neutralizantes , Anticorpos Antivirais , COVID-19/terapia , Furocumarinas , Humanos , Imunização Passiva , SARS-CoV-2 , Soroterapia para COVID-19
8.
Transfusion ; 62 Suppl 1: S185-S192, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35748692

RESUMO

BACKGROUND: Evidence indicates the life-saving benefits of early blood product transfusion in severe trauma resuscitation. Many of these products will be RhD-positive, so understanding the D-alloimmunization rate is important. METHODS: This was a multicenter, retrospective study whereby injured RhD-negative patients between 18-50 years of age who received at least one unit of RhD-positive red blood cells (RBC) or low titer group O whole blood (LTOWB) during their resuscitation between 1 January, 2010 through 31 December, 2019 were identified. If an antibody detection test was performed ≥14 days after the index RhD-positive transfusion then basic demographic information was collected, including whether the patient became D-alloimmunized. The overall D-alloimmunization rate, and the rate stratified by the number of units transfused, were calculated. RESULTS: Data were collected from nine institutions. Five institutions reported fewer than 10 eligible patients each and were excluded. From the remaining four institutions, all from the USA, there were 235 eligible patients; 77 (random effects estimate: 32.7%; 95% CI: 19.1-50.1%) became D-alloimmunized. Three of the institutions reported D-alloimmunization rates ≥38.6%, while the remaining institution's rate was 12.2%. In both random and fixed-effects models, the rate of D-alloimmunization was not significantly different between those who received one RhD-positive unit and those who received multiple RhD-positive units. CONCLUSION: In this large, multicenter study of injured patients, the overall rate of D-alloimmunization fell within the range previously reported. The rate of D-alloimmunization did not increase as the number of transfused RhD-positive units increased. These data can help to inform RhD type selection decisions.


Assuntos
Anemia Hemolítica Autoimune , Sistema do Grupo Sanguíneo Rh-Hr , Sistema ABO de Grupos Sanguíneos , Eritrócitos , Humanos , Isoanticorpos , Estudos Retrospectivos
9.
Transfusion ; 62(8): 1559-1570, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35808950

RESUMO

BACKGROUND: At the start of the coronavirus disease 2019 (COVID-19) pandemic, widespread blood shortages were anticipated. We sought to determine how hospital blood supply and blood utilization were affected by the first wave of COVID-19. STUDY DESIGN AND METHODS: Weekly red blood cell (RBC) and platelet (PLT) inventory, transfusion, and outdate data were collected from 13 institutions in the United States, Brazil, Canada, and Denmark from March 1st to December 31st of 2020 and 2019. Data from the sites were aligned based on each site's local first peak of COVID-19 cases, and data from 2020 (pandemic year) were compared with data from the corresponding period in 2019 (pre-pandemic baseline). RESULTS: RBC inventories were 3% lower in 2020 than in 2019 (680 vs. 704, p < .001) and 5% fewer RBCs were transfused per week compared to 2019 (477 vs. 501, p < .001). However, during the first COVID-19 peak, RBC and PLT inventories were higher than normal, as reflected by deviation from par, days on hand, and percent outdated. At this time, 16% fewer inpatient beds were occupied, and 43% fewer surgeries were performed compared to 2019 (p < .001). In contrast to 2019 when there was no correlation, there was, in 2020, significant negative correlations between RBC and PLT days on hand and both percentage occupancy of inpatient beds and percentage of surgeries performed. CONCLUSION: During the COVID-19 pandemic in 2020, RBC and PLT inventories remained adequate. During the first wave of cases, significant decreases in patient care activities were associated with excess RBC and PLT supplies and increased product outdating.


Assuntos
COVID-19 , Pandemias , COVID-19/epidemiologia , Transfusão de Eritrócitos , Eritrócitos , Hospitais , Humanos , Estados Unidos
10.
Transfusion ; 62(5): 933-941, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35352362

RESUMO

Convalescent plasma, collected from donors who have recovered from a pathogen of interest, has been used to treat infectious diseases, particularly in times of outbreak, when alternative therapies were unavailable. The COVID-19 pandemic revived interest in the use of convalescent plasma. Large observational studies and clinical trials that were executed during the pandemic provided insight into how to use convalescent plasma, whereby high levels of antibodies against the pathogen of interest and administration early within the time course of the disease are critical for optimal therapeutic effect. Several studies have shown outpatient administration of COVID-19 convalescent plasma (CCP) to be both safe and effective, preventing clinical progression in patients when administered within the first week of COVID-19. The United States Food and Drug Administration expanded its emergency use authorization (EUA) to allow for the administration of CCP in an outpatient setting in December 2021, at least for immunocompromised patients or those on immunosuppressive therapy. Outpatient transfusion of CCP and infusion of monoclonal antibody therapies for a highly transmissible infectious disease introduces nuanced challenges related to infection prevention. Drawing on our experiences with the clinical and research use of CCP, we describe the logistical considerations and workflow spanning procurement of qualified products, infrastructure, staffing, transfusion, and associated management of adverse events. The purpose of this description is to facilitate the efforts of others intent on establishing outpatient transfusion programs for CCP and other antibody-based therapies.


Assuntos
COVID-19 , COVID-19/terapia , Humanos , Imunização Passiva , Pacientes Ambulatoriais , Pandemias , SARS-CoV-2 , Estados Unidos , Soroterapia para COVID-19
11.
Vox Sang ; 117(7): 929-936, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35405021

RESUMO

BACKGROUND AND OBJECTIVES: Donor eligibility questions and criteria for medical conditions vary between blood centres, suggesting that they are based more on local regulations or experience, rather than on published data, which are limited. As the donor population ages, medical conditions become more common. We assessed donor health assessment criteria at blood centre members of the Biomedical Excellence for Safer Transfusion (BEST) Collaborative. Our aim was to compare eligibility criteria and determine their underlying basis. MATERIALS AND METHODS: A REDCap survey was sent to blood centre participants, based on medical conditions of greatest interest suggested by the Donor Studies Team of the BEST Collaborative. Participants were asked about current donor health assessment questions, deferral criteria and the basis for their deferral policy (donor risk, recipient risk or both) for 20 medical conditions. RESULTS: Complete responses were received from 26 blood donor centres (24 separate responses) representing a combination of hospital-based centres, large regional centres and community/national blood centres in 14 different countries. Most centres specifically ask about heart and lung conditions, whereas fewer than half inquire about kidney, gastrointestinal or neurological conditions. North American blood centres tended to be less restrictive, while regulatory restrictions are more prevalent in Europe. Most participants felt that the criteria were based on regulatory requirements or experience, rather than on published data. CONCLUSION: There is considerable variability in criteria by region. Ideally, criteria would be more evidence-based rather than based on regulatory requirements or experience. Deferral criteria must balance donor and recipient safety and maintain an adequate blood supply.


Assuntos
Doadores de Sangue , Seleção do Doador , Transfusão de Sangue , Europa (Continente) , Humanos , Inquéritos e Questionários
12.
Transfusion ; 61(4): 1014-1022, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33720397

RESUMO

Despite the significantly reduced infectious disease risk through robust and sensitive laboratory assays, comprehensive donor screening and good manufacturing practices, new and emerging infectious agents and bacterial contamination continue to pose a threat to the blood supply. Pathogen Reduction (PR) technology is an option to mitigate the risk of platelet transfusion transmitted infections. Here we describe our structure and strategies to implement PR technology. Pre-implementation and phased approach implementation processes from our hospital-based donor center, components processing laboratory, transfusion service, clinicians, nursing, and patient perspectives are described. Communication and reassessment of collection settings occurred between the donor center and components processing laboratory (CPL). During Phase 1, CPL consistently processed approximately 56% of monthly apheresis platelets (AP) collections by PR and the remaining 44% as conventional platelets (CP). Phase 2 increased the amount of AP undergoing PR from 56% to approximately 78%. A phased implementation and maintenance of a dual inventory may provide flexibility to blood collection, blood manufacturing, and transfusion service processes. Our dual inventory of PR and CP allows our transfusion service a readily available platelet inventory. A collaborative hospital-based donor center, component processing laboratory, and transfusion service are essential to the productivity and maintenance of the dual platelet inventory.


Assuntos
Plaquetas/microbiologia , Transfusão de Plaquetas/efeitos adversos , Reação Transfusional/prevenção & controle , Remoção de Componentes Sanguíneos/estatística & dados numéricos , Seleção do Doador/normas , Humanos , Transfusão de Plaquetas/normas , Transfusão de Plaquetas/estatística & dados numéricos , Tecnologia , Medicina Transfusional/ética , Medicina Transfusional/legislação & jurisprudência
13.
Transfusion ; 61(10): 2869-2876, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34448199

RESUMO

BACKGROUND: Pathogen-reduced platelets (PR PLT) are the emerging standard for proactive transfusion-transmitted infection (TTI) mitigation. There is, however, continued hesitation to transfuse PR PLT in children due to limited published data. We report demographics, rates of transfusion, and transfusion reactions (TR) associated with FDA-approved PR PLT in pediatric and neonatal patients at an academic medical center. METHODS: Retrospective review was performed for patients <18 years receiving at least one platelet over a 300-day period at a large, tertiary care hospital. Patients were transfused PR or conventional (CONV) PLT, based on inventory availability. Statistical analysis was performed using Fisher Exact Test. RESULTS: During the study period, 191 patients received 1010 platelet transfusions (892 units). Sixty-eight patients received PR PLT only (1.3 units/patient, 95% confidence interval [CI] 1.1-1.5; 1.8 transfusions/patient, 95% CI 1.4-2.2), and 56 patients received CONV PLT only (1.4 units/patient, 95% CI 1.1-1.7; 1.6 transfusions/patient, 95% CI 1.3-1.9). Patients with hematologic malignancies undergoing chemotherapy/radiation and allogeneic hematopoietic stem cell transplant received the most platelet transfusions and more commonly received both platelet types. Of 506 PR PLT units, 5 TRs occurred; 386 CONV PLT resulted in two TRs (p = .7052). Of 51 neonates, 37 received PR PLT without adverse events, including 13 receiving phototherapy. No TTIs were identified in any group. CONCLUSION: There was no significant difference in rates of transfusion or TRs between PR and CONV PLT. Our study provides additional evidence that PR PLT can be transfused to pediatric and neonatal patients without increasing the risk of acute adverse events.


Assuntos
Segurança do Sangue , Transfusão de Plaquetas/efeitos adversos , Adolescente , Plaquetas/citologia , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Estudos Retrospectivos , Fatores de Risco
14.
Transfusion ; 61(9): 2668-2676, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34227689

RESUMO

BACKGROUND: Although the safety and therapeutic efficacy of COVID-19 convalescent plasma (CCP) has been extensively evaluated, the safety of CCP donation has not been explored in a multi-institutional context. STUDY DESIGN AND METHODS: Nine blood collection organizations (BCOs) participated in a multi-institutional donor hemovigilance effort to assess the safety of CCP donation. Donor adverse events (DAEs) were defined according to the Standard for Surveillance of Complications Related to Blood Donation, and severity was assessed using the severity grading tool. Multivariate analysis was performed to determine attributes associated with DAE severity. RESULTS: The overall DAE rate was 37.7 per 1000 donations. Repeat apheresis and apheresis-naïve donors experienced adverse event rates of 19.9 and 49.8 per 1000 donations, respectively. Female donors contributed 51.9% of CCP donations with a DAE rate of 49.4 per 1000 donations. The DAE rate for male donors was 27.4 per 1000 donations. Vasovagal reactions accounted for over half of all reported DAEs (51.1%). After adjustment, volume of CCP donated was associated with vasovagal reaction severity (odds ratio [OR] 6.5, 95% confidence interval [CI] 2.5-17.1). Donor age and donation history were also associated with DAE severity. Considerable differences in DAE types and rates were observed across the participating BCOs despite the use of standardized hemovigilance definitions. CONCLUSION: The safety of CCP donation appears comparable to that of conventional apheresis plasma donation with similar associated risk factors for DAE types and severity.


Assuntos
Doadores de Sangue , Segurança do Sangue , COVID-19/sangue , COVID-19/imunologia , SARS-CoV-2/imunologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , COVID-19/diagnóstico , COVID-19/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Vigilância em Saúde Pública , Estudos Retrospectivos , Índice de Gravidade de Doença , Estados Unidos/epidemiologia , Adulto Jovem
15.
Transfusion ; 60(4): 675-681, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32027394

RESUMO

The United States Food and Drug Administration Final Guidance for Industry titled, "Bacterial Risk Control Strategies for Blood Collection Establishments and Transfusion Services to Enhance the Safety and Availability of Platelets for Transfusion" provides nine strategies for platelet bacterial risk mitigation. Even if it is assumed all strategies are comparable in terms of safety and efficacy, the decision of which to implement remains challenging. Some additional factors that warrant evaluation before selecting a strategy include the financial impact, process for implementation, logistics upon implementation, institutional acceptance by blood bank staff, administration and clinicians, and effect on platelet availability. To assist with this difficult choice, a panel of transfusion service physicians who have expertise on the topic and have already selected strategies for their transfusion services were recruited to provide varied perspectives. In addition, the use of a decision-making tool that objectively evaluates defined criteria for assessment of the nine strategies is described.


Assuntos
Plaquetas/microbiologia , Tomada de Decisões , Hospitais , Transfusão de Plaquetas/normas , Algoritmos , Bactérias/crescimento & desenvolvimento , Armazenamento de Sangue/métodos , Hospitais/normas , Humanos , Transfusão de Plaquetas/efeitos adversos , Risco , Estados Unidos
16.
Transfusion ; 60(11): 2517-2528, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32901965

RESUMO

BACKGROUND: This study investigated the effect on mortality of transfusing ABO-incompatible plasma from all sources during trauma resuscitation. METHODS: Demographic, transfusion, and survival data were retrospectively extracted on civilian trauma patients. Patients were divided by receipt of any quantity of ABO-incompatible plasma from any blood product (incompatible group) or receipt of solely ABO-compatible plasma (compatible group). The primary outcome was 30-day mortality, while other outcomes included 6- and 24-hour mortality. Mixed-effects logistic regression was used to model the effect of various predictor variables, including receipt of incompatible plasma, on mortality outcomes. RESULTS: Nine hospitals contributed data on a total of 2618 trauma patients. There were 1282 patients in the incompatible group and 1336 patients in the compatible group. In both the unadjusted and adjusted models, the 6-hour, 24-hour, and 30-day mortality rates were not significantly different between these groups. The patients in the incompatible group were then divided into high volume (>342 mL) and low volume (≤342 mL) incompatible plasma recipients. In the adjusted model, the high-volume group had higher 24-hour mortality when the Trauma Injury Severity Score survival prediction was >50%. Mortality at 6 hours and 30 days was not higher in this model. The low-volume group did not have increased mortality at any of the time points in this adjusted model. CONCLUSION: The transfusion of incompatible plasma in civilian trauma resuscitation does not lead to higher 30-day mortality. The finding of higher mortality in a select group of recipients in the secondary analysis warrants further study.


Assuntos
Sistema ABO de Grupos Sanguíneos/sangue , Transfusão de Componentes Sanguíneos , Incompatibilidade de Grupos Sanguíneos , Modelos Biológicos , Ressuscitação , Ferimentos e Lesões , Adulto , Idoso , Idoso de 80 Anos ou mais , Intervalo Livre de Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taxa de Sobrevida , Índices de Gravidade do Trauma , Ferimentos e Lesões/sangue , Ferimentos e Lesões/mortalidade , Ferimentos e Lesões/terapia
17.
Anesthesiology ; 132(3): 525-534, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31789634

RESUMO

BACKGROUND: Group O erythrocytes and/or whole blood are used for urgent transfusions in patients of unknown blood type. This study investigated the impact of transfusing increasing numbers of uncrossmatched type O products on the recipient's first in-hospital ABO type. METHODS: This was a retrospective cohort study. Results of the first ABO type obtained in adult, non-type O recipients (i.e., types A, B, AB) after receiving at least one unit of uncrossmatched type O erythrocyte-containing product(s) for any bleeding etiology were analyzed along with the number of uncrossmatched type O erythrocyte-containing products administered in the prehospital and/or in hospital setting before the first type and screen sample was drawn. RESULTS: There were 10 institutions that contributed a total of 695 patient records. Among patients who received up to 10 uncrossmatched type O erythrocyte-containing products, the median A antigen agglutination strength in A and AB individuals on forward typing (i.e., testing the recipient's erythrocytes for A and/or B antigens) was the maximum (4+), whereas the median B antigen agglutination strength among B and AB recipients of up to 10 units was 3 to 4+. The median agglutination strength on the reverse type (i.e., testing the recipient's plasma for corresponding anti-A and -B antibodies) was very strong, between 3 and 4+, for recipients of up to 10 units of uncrossmatched erythrocyte-containing products. Overall, the ABO type of 665 of 695 (95.7%; 95% CI, 93.9 to 97.0%) of these patients could be accurately determined on the first type and screen sample obtained after transfusion of uncrossmatched type O erythrocyte-containing products. CONCLUSIONS: The transfusion of smaller quantities of uncrossmatched type O erythrocyte-containing products, in particular up to 10 units, does not usually interfere with determining the recipient's ABO type. The early collection of a type and screen sample is important.


Assuntos
Sistema ABO de Grupos Sanguíneos , Tipagem e Reações Cruzadas Sanguíneas/métodos , Transfusão de Sangue/métodos , Transfusão de Eritrócitos/métodos , Adulto , Aglutinação , Estudos de Coortes , Serviços Médicos de Emergência , Hemorragia/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Ferimentos e Lesões/terapia
18.
Vox Sang ; 115(6): 515-524, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32249930

RESUMO

BACKGROUND: Warm autoantibodies (WAA) are antibodies that react with an antigen on a patient's own red-blood-cells and can complicate compatibility testing whether or not they cause clinical haemolysis. The goal of this study was to understand the overall prevalence of WAA, the risk of RBC alloimmunization and determine whether RBC selection practices have an impact on alloimmunization. MATERIALS AND METHODS: Records of patients (>1 year of age) with an indirect antibody detection test (IAT) and serologic evidence of WAA over a 10-year-period were included. Eight centres from 5 countries collectively reviewed 1 122 245 patients who had an IAT. RESULTS: Of patients having IAT, 1214 had WAA (0·17%). Transfusion information for 1002 of the patients was available; 631 were transfused after identification of the WAA (63%); of the transfused patients, 390 received prophylactic antigen-matched (PAM) RBCs and 241 did not. Of the 372 patients with WAA who were transfused and had serologic testing 30+ days following transfusion (30-2765 days), 56 developed new RBC alloimmunization (15·1%). Patients who were transfused using a PAM strategy were not protected from new RBC alloimmunization [14·6% (31 of 212 patients) having PAM transfusion approach compared with those not receiving PAM approach (15·6%, 25 of 160 patients, P = 0·8837)]. CONCLUSIONS: The prevalence of WAA in patients having an IAT is low (<1%). A significant portion of patients with WAA form new RBC alloimmunization (15·1%); however, the use of PAM approach for RBC selection was not found to be protective against new alloimmunization.


Assuntos
Anemia Hemolítica Autoimune/epidemiologia , Autoanticorpos/imunologia , Transfusão de Sangue Autóloga/métodos , Adulto , Anemia Hemolítica Autoimune/etiologia , Transfusão de Sangue Autóloga/efeitos adversos , Eritrócitos/imunologia , Feminino , Humanos , Masculino
19.
Transfusion ; 59(S2): 1512-1517, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30980760

RESUMO

BACKGROUND: Many transfusion services determine the titer of potentially incompatible plasma-containing products by performing a one-dilution titer at their selected titer threshold. This study compared the results of immediate spin (IS) one-dilution titers determined by three methods with a reference standard method. METHODS: Plasma-containing products from group A and O donors were titered using the participant's routine IS one-dilution titer method. No time or temperature incubations were performed, and antihuman globulin reagent was not used. The samples were then tested using a reference method, which was a saline tube test with a 1-hour room temperature incubation; antihuman globulin was not used in the reference method. The results of the one-dilution titer were then compared to that obtained in the reference method. RESULTS: Nine centers participated in this study. There were 698 antibodies from 374 units tested by the manual IS tube one-dilution titer method; sensitivity was 0.88 (95% confidence interval [CI], 0.83-0.92), and specificity was 1.00 (95% CI, 0.98-1.00). There were 412 antibodies from 206 units tested by the manual and automated IS buffered gel card one-dilution titer method; sensitivity was 0.95 (95% CI, 0.91-0.98), and specificity was 0.87 (95% CI, 0.81-0.91). There were 98 antibodies from 49 units tested by an automated microplate IS one-dilution titer method; sensitivity was 0.76 (95% CI, 0.71-0.93), and specificity was 0.96 (95% CI, 0.92-0.99). All three methods had an accuracy rate of 90% or greater. CONCLUSION: The manual and automated one-dilution titer methods are suitable for screening plasma-containing units, although more evaluation of the automated microplate method might be required.


Assuntos
Sistema ABO de Grupos Sanguíneos/sangue , Incompatibilidade de Grupos Sanguíneos/sangue , Isoanticorpos/sangue , Manejo de Espécimes/métodos , Feminino , Humanos , Técnicas de Diluição do Indicador , Masculino
20.
Transfusion ; 59(2): 762-767, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30548267

RESUMO

BACKGROUND: ABO-incompatible platelet transfusions are common, and transfusions with ABO-incompatible plasma are increasing with the use of group A plasma and group O whole blood (WB) in emergencies. Many centers screen blood products for anti-A and/or anti-B titers to help prevent hemolysis from ABO-incompatible transfusions, yet titer methods and definition of high titers are not standardized. STUDY DESIGN AND METHODS: This international multicenter study collected data on anti-A and anti-B titer practices for plasma, apheresis platelet (AP), and WB units from January 2015 through December 2017 to determine the prevalence of high-titer units using local definitions. RESULTS: A total of 87,701 plasma, AP and WB units were screened for high-titer anti-A and/or anti-B. High-titer detection rates for group A plasma ranged 0%-13.6%; group A AP 2.7%-9.3%; group O AP 2.3%-65.7%; and group O WB 6.4%-20.7%. At the one center that collected group B AP, the high-titer rate was 10.9%. High-titer rates varied from month to month, as well as between years for a given month. There was no clear pattern of when high-titer units were donated. CONCLUSION: The prevalence of high-titer plasma, AP, and WB units varies by titer method and local definition of high titer. Even at the lowest titer threshold of 50, a significant proportion of units had a high-titer antibody, although the clinical relevance of this finding needs further investigation.


Assuntos
Sistema ABO de Grupos Sanguíneos/sangue , Isoanticorpos/sangue , Estações do Ano , Incompatibilidade de Grupos Sanguíneos/sangue , Incompatibilidade de Grupos Sanguíneos/epidemiologia , Feminino , Humanos , Masculino , Transfusão de Plaquetas/efeitos adversos , Plaquetoferese , Reação Transfusional/sangue , Reação Transfusional/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA