Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
1.
J Biol Regul Homeost Agents ; 33(4): 1013-1018, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31304689

RESUMO

The aim of this study is to develop a decision-making path for the management of non-carious cervical lesions (NCCLs) associated with or without dentin hypersensitivity (DH) This will allow to limit or delay invasive approaches identifying the causes that produced them. The need for this review is because there are no clear guidelines in the current literature for the treatment of NCCLs. Usually, the selection of the best therapy option is postponed to clinical judgment which can be influenced by a patient's demands (aesthetic, symptomatologic reasons or worsening of pre-existing NCCL). To establish a therapeutic plan the young dentist should be able to distinguish the NCCLs that need to be monitored over time from those in need of early treatment. Indeed, the experience of the dentist and the compliance of the patient play a decisive role for the success of the therapy.


Assuntos
Tomada de Decisão Clínica , Sensibilidade da Dentina/terapia , Manejo da Dor , Colo do Dente/patologia , Humanos , Dor
2.
J Biol Regul Homeost Agents ; 32(4): 1001-1005, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30043585

RESUMO

Precision of impression is one of the keys for the success of implant-prosthetic rehabilitation. The choice of correct techniques, performance materials, and operator skills, can improve the accuracy of impression. The proposed technique describes a modified pick-up impression technique, both for single and multiple implants, aiming to combine the advantages of direct technique (open-tray or pick-up impression) with those of indirect technique (closed-tray or transfer type impression technique) in order to improve the accuracy of implant impression.


Assuntos
Implantes Dentários , Técnica de Moldagem Odontológica , Humanos
3.
J Tissue Viability ; 25(2): 83-90, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26818777

RESUMO

A D-optimal design was used to identify and model variables that affect the transit time of wound exudate through an illustrative dressing used for negative pressure wound therapy. Many authors have addressed the clinical benefits of negative pressure wound therapy, but limited information is available on how to assess performances of dressings. In this paper, the transit time of wound exudate through a dressing was chosen as a model parameter to show how experimental design (DOE) can be used for this purpose. Results demonstrated that rate of exudate production, temperature and dressing thickness were the variables with the largest impact on transit time. The DOE approach could be used to model other dressing properties, like for example capability of absorbing excess exudate or breathability.


Assuntos
Bandagens , Exsudatos e Transudatos/fisiologia , Tratamento de Ferimentos com Pressão Negativa/instrumentação , Modelos Teóricos , Tratamento de Ferimentos com Pressão Negativa/métodos
4.
Pediatr Transplant ; 19(4): 358-65, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25879299

RESUMO

Biliary complications remain a major challenge for long-term success after LT, as it is, as a rule, the most common technical - early and late - complication that occurs, and because these complications contribute to a significant number of late graft losses and retransplantations. In the pediatric age group, both biliary atresia, as the patient's condition, and the use of a left liver graft, obtained by a liver division technique, make it necessary for the use of a Roux-en-Y jejunal loop for the biliary reconstruction in the majority of cases. A slight modification of the technique is presented, consisting of a straight positioning along the cut surface (rather than the conventional position that results in a harpoon shape). A favorable outcome in terms of a technical complication and graft survival was observed. This way of doing this is an interesting variation and adds to the surgical armamentarium.


Assuntos
Anastomose em-Y de Roux/métodos , Jejunostomia/métodos , Transplante de Fígado/métodos , Anastomose Cirúrgica , Ductos Biliares/cirurgia , Procedimentos Cirúrgicos do Sistema Biliar/métodos , Criança , Pré-Escolar , Feminino , Sobrevivência de Enxerto , Humanos , Lactente , Fígado/cirurgia , Imageamento por Ressonância Magnética , Masculino , Estudos Retrospectivos
5.
Pediatr Transplant ; 19(5): 517-26, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26059061

RESUMO

UNLABELLED: Controversy remains about the best line of division for liver splitting, through Segment IV or through the umbilical fissure. Both techniques are currently used, with the choice varying between surgical teams in the absence of an evidence-based choice. We conducted a single-center retrospective analysis of 47 left split liver grafts that were procured with two different division techniques: "classical" (N = 28, Group A) or through the umbilical fissure and plate (N = 19, Group B). The allocation of recipients to each group was at random; a single transplant team performed all transplantations. Demographics, characteristics, technical aspects, and outcomes were similar in both groups. The grafts in Group A, prepared with the classical technique, were procured more often with a single BD orifice compared with the grafts in Group B; however, this was not associated with a higher incidence of biliary problems in this series of transplants (96% actual graft survival rate [median ± s.d. FOLLOW-UP: 26 ± 20 months]). Both techniques provide good quality split grafts and an excellent outcome; surgical expertise with a given technique is more relevant than the technique itself. The classical technique, however, seems to be more flexible in various ways, and surgeons may find it to be preferable.


Assuntos
Hepatectomia/métodos , Transplante de Fígado/métodos , Fígado/cirurgia , Procedimentos Cirúrgicos Operatórios , Adulto , Criança , Pré-Escolar , Bases de Dados Factuais , Sobrevivência de Enxerto , Humanos , Lactente , Doadores Vivos , Pessoa de Meia-Idade , Estudos Retrospectivos , Obtenção de Tecidos e Órgãos , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Umbigo/cirurgia
7.
Talanta ; 282: 127014, 2024 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-39406088

RESUMO

A Laser-Induced Graphene-based (LIG) electrode covalently functionalized with an aptamer (P12-55) was used to develop an aptasensor detecting Escherichia coli in urine samples. Recent strides in material science have spotlighted LIG for exceptional attributes like robust mechanical resistance, superior conductivity, extensive surface area, and facile synthesis/patterning on various polymeric substrates. Variations in the aptasensor charge transfer resistance upon interaction with bacterial cells were evaluated by electrochemical impedance spectroscopy. Tests in phosphate buffer saline solution showed the aptasensor linear response for E. coli between 100 and 103 CFU/mL. The sensor proved to be selective for E. coli as a negligible response was observed in the presence of Staphylococcus aureus or Pseudomonas aeruginosa. Finally, the sensor was calibrated in urine samples spiked with a known concentration of E. coli cells. Its characteristics make the aptasensor viable for low-cost and portable devices identifying pathogenic microorganisms at the point-of-need. Due to the short response time (about 30 min), we believe that these sensing devices may significantly improve control and management of urinary tract infections.

8.
J Breath Res ; 17(4)2023 08 29.
Artigo em Inglês | MEDLINE | ID: mdl-37567168

RESUMO

Solid-phase sorption is widely used for the analysis of gaseous specimens as it allows at the same time to preconcentrate target analytes and store samples for relatively long periods. The addition of internal standards (ISs) in the analytical workflow can greatly reduce the variability of the analyses and improve the reliability of the protocols. In this work, we describe the development and testing of a portable system for the reliable production of gaseous mixture of8D-Toluene in a 1L Silonite canister as well as its reproducible loading into solid-phase sorbing tools as ISs. The portable system was tested using needle trap microextraction, solid-phase extraction, and thin-film microextraction techniques commonly employed for the analysis of gaseous samples. Even though our specific interest is in breath analysis, the system can also be used for the collection of any kind of gaseous specimen. A microcontroller allows the fine control of the sampling flow by a digital mass flow controller. Flow rate and sample volume could be set either through a rotary encoder mounted onto the control board or through a dedicated android app. The variability of the airflow is in the range 5-200 ml min-1and it is lower than 1%, whereas the variability of the IS (8D-Toluene) concentration dispensed over time by the loader measured by selected-ion flow-tube mass spectrometry (MS) is <3%. This combination resulted in intra- and inter-day precision of the amount loaded in the sorbent tools lower than 15%. No carry-over was detected in the loader after the delivery of the8D-Toluene measured by gas chromatography-MS. The8D-Toluene concentration in the canister was stable for up to three weeks at room temperature.


Assuntos
Testes Respiratórios , Microextração em Fase Sólida , Humanos , Microextração em Fase Sólida/métodos , Reprodutibilidade dos Testes , Cromatografia Gasosa-Espectrometria de Massas/métodos , Tolueno/análise , Gases
9.
APL Bioeng ; 6(3): 036104, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36147196

RESUMO

The scientific community has shown increasing interest in laser scribing for the direct fabrication of conductive graphene-based tracks on different substrates. This can enable novel routes for the noninvasive analysis of biofluids (such as sweat or other noninvasive matrices), whose results can provide the rapid evaluation of a person's health status. Here, we present a wearable sensing platform based on laser induced graphene (LIG) porous electrodes scribed on a flexible polyimide sheet, which samples sweat through a paper sampler. The device is fully laser manufactured and features a two layer design with LIG-based vertical interconnect accesses. A detailed characterization of the LIG electrodes including pore size, surface groups, surface area in comparison to electroactive surface area, and the reduction behavior of different LIG types was performed. The bare LIG electrodes can detect the electrochemical oxidation of both uric acid and tyrosine. Further modification of the surface of the LIG working electrode with an indoaniline derivative [4-((4-aminophenyl)imino)-2,6-dimethoxycyclohexa-2,5-dien-1-one] enables the voltammetric measurement of pH with an almost ideal sensitivity and without interference from other analytes. Finally, electrochemical impedance spectroscopy was used to measure the concentrations of ions through the analysis of the sweat impedance. The device was successfully tested in a real case scenario, worn on the skin during a sports session. In vitro tests proved the non-cytotoxic effect of the device on the A549 cell line.

10.
J Breath Res ; 15(2)2021 01 22.
Artigo em Inglês | MEDLINE | ID: mdl-33302258

RESUMO

Exhaled breath contains hundreds of volatile organic compounds (VOCs) which offer the potential for diagnosing and monitoring a wide range of diseases. As the breath research field has grown, sampling and analytical practices have become highly varied between groups. Standardisation would allow meta-analyses of data from multiple studies and greater confidence in published results. Washout of VOCs from ingestion into the blood and subsequently breath could provide data for an initial assessment of inter-group performance. The Peppermint Initiative has been formed to address this task of standardisation. In the current study we aimed to generate initial benchmark values for thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS) analysis of breath samples containing peppermint-derived VOCs using data from three independent European research groups. Initially, headspace analysis of peppermint oil capsules was performed to determine compounds of interest. Ten healthy participants were recruited by each three groups across Europe. The standard Peppermint protocol was followed. In brief, each participant provided a baseline breath sample prior to taking a peppermint capsule, with further samples collected at 60, 90, 165, 285 and 360 min following ingestion. Sampling and analytical protocols were different for each group, in line with their usual practice. Samples were analysed by TD-GC-MS and benchmarking values determined for the time taken for detected peppermint VOCs to return to baseline values. Sixteen compounds were identified in the capsule headspace, and all were confirmed in breath following ingestion of the peppermint capsules. Additionally, 2,3-dehydro-1,8-cineole was uniquely found in the breath samples, with a washout profile that suggested it was a product of metabolism of peppermint compounds. Five compounds (α-pinene, ß-pinene, eucalyptol, menthol and menthone) were quantified by all three groups. Differences were observed between the groups, particularly for the recovery of menthone and menthol. The average time taken for VOCs to return to baseline was selected as the benchmark and were 377, 423, 533, 418 and 336 min for α-pinene, ß-pinene, eucalyptol, menthone and menthol respectively. We have presented an initial set of easy-to-measure benchmarking values for assessing the performance of TD-GC-MS systems for the analysis of VOCs in breath. These values will be updated when more groups provide additional data.


Assuntos
Mentha piperita , Compostos Orgânicos Voláteis , Benchmarking , Testes Respiratórios/métodos , Expiração , Cromatografia Gasosa-Espectrometria de Massas/métodos , Humanos , Mentha piperita/química , Compostos Orgânicos Voláteis/análise
11.
Gut ; 57(3): 352-64, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17989109

RESUMO

BACKGROUND: Endogenous opioids modulate the growth of nervous and non-nervous cells. Hepatic stellate cells (HSCs) are the main cell phenotype involved in liver fibrogenesis, display molecular markers of neuronal cells and respond to neurotransmitters. AIM: To evaluate the role of endogenous opioids on liver fibrogenesis. METHODS: Activated rat HSCs (passage 1-3) were used to evaluate cell proliferation and intracellular signalling pathway activation. Liver fibrosis was induced in rats by dimethylnitrosamine (DMN) administration. RESULTS: Opioid receptors showed a different pattern of expression when measured in quiescent and activated (in vitro and in vivo) HSCs. The activation of opioid receptors increased HSC proliferation and collagen accumulation. Opioid receptor stimulation induced a calcium-dependent protein kinase C alpha (PKC alpha)/extracellular regulated kinase (ERK)/phosphatidylinositol 3-kinase (PI3K) pathway activation that mediated the effect of endogenous opioids on HSC proliferation and collagen synthesis. In DMN-treated rats, the opioid antagonist naloxone reduced alpha-smooth muscle actin expression (as a marker of HSC activation) and collagen deposition, both measured by morphometry after 5 weeks of treatment. In both DMN-treated rats and human liver biopsies from chronic liver diseases, opioid receptors were observed in HSCs in area of active fibrogenesis. The endogenous opioid met-enkephalin increased its expression in zone 3 hepatocytes close to the area of necrosis after DMN administration and in the cellular target of chronic liver injury in human biopsies, and stimulated HSC proliferation and collagen synthesis. CONCLUSIONS: Endogenous opioids released during chronic liver injury participate in the process of liver fibrogenesis by stimulating HSC proliferation and collagen production in a paracrine manner.


Assuntos
Hepatócitos/fisiologia , Cirrose Hepática Experimental/patologia , Peptídeos Opioides/fisiologia , Animais , Proliferação de Células , Células Cultivadas , Doença Crônica , Colágeno Tipo I/metabolismo , Dimetilnitrosamina , Progressão da Doença , Encefalina Metionina/metabolismo , Encefalina Metionina/farmacologia , Hepatócitos/efeitos dos fármacos , Hepatócitos/metabolismo , Humanos , Fígado/metabolismo , Cirrose Hepática Experimental/induzido quimicamente , Cirrose Hepática Experimental/metabolismo , Hepatopatias/metabolismo , Masculino , Comunicação Parácrina , Ratos , Receptores Opioides/metabolismo , Transdução de Sinais/fisiologia
12.
Annu Int Conf IEEE Eng Med Biol Soc ; 2019: 1159-1162, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31946099

RESUMO

Acetylcholine is a neurotransmitter and a neuromodulator found in the autonomic, peripheral and central nervous systems. Diazinon is a pesticide with toxic effects on humans, such as the inhibition of acetylcholine. In this paper, a biosensor is proposed for the detection of acetylcholine (range 70 - 1000 µM) and diazinon (range 0.3 - 20000 ppb). This biosensor combines a pH-sensitive layer of reduced graphene oxide functionalized with 4-aminobenzoic acid and acetylcholinesterase. This enzyme was immobilized on reduced graphene oxide and it catalyzed the conversion of acetylcholine into choline and acetic acid, locally decreasing the pH value and triggering the sensor response. The limit of detection for the acetylcholine and diazinon were 70 µM and 0.3 ppb, respectively.


Assuntos
Acetilcolina , Técnicas Biossensoriais , Diazinon , Acetilcolina/análise , Diazinon/análise , Eletrodos , Enzimas Imobilizadas , Humanos
13.
Annu Int Conf IEEE Eng Med Biol Soc ; 2019: 2226-2229, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31946343

RESUMO

Exhaled air and breath condensate contain a large number of health biomarkers, such as volatile and semi-volatile organic compounds, proteins and lipids. Nowadays, the collection of breath samples is carried out by commercial or lab-made sampling systems that collect only one type of sample (e.g. gaseous or condensate phase), thus limiting the diagnostic capability of breath tests. This work presents a portable prototype optimized for the simultaneous collection of gaseous exhaled breath and exhaled breath condensate within five minutes. The system is fully portable and has a total weight of about 1 Kg. An illustrative determination of ethanol, isoprene, acetone, isopropyl alcohol, 1-propanol, 2-butanone, 2-pentanone, toluene and xylenes in breath, and cortisol and 8-iso-prostaglandin F2α in breath condensate is discussed.


Assuntos
Testes Respiratórios , Compostos Orgânicos Voláteis , Biomarcadores , Testes Respiratórios/instrumentação , Expiração , Manejo de Espécimes
14.
Surg Endosc ; 22(2): 298-310, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17943372

RESUMO

BACKGROUND: Video-assisted thoracic surgery (VATS) in the diagnosis and treatment of pulmonary diseases has been used since the early 1990s, yet its impact on intraoperative and postoperative morbidity has not yet been fully evaluated. This report aims to provide a retrospective analysis of the literature and the authors' clinical experience with VATS in pulmonary surgery, with the goal of ascertaining rational criteria that explain operative complications and thus improve outcomes. METHODS: Over a period of 15 years 1,615 VATS procedures were performed in our department, 743 of which involved only the lung. The accesses employed were based on the use of three ports through which a thoracoscope, endoscopic instruments, and an endostapler were inserted; for major pulmonary resections, a utility thoracotomy without rib spreader was added. Resections less than segmentectomy were performed using the endostapler directly on the parenchyma, whereas in the anatomic resections all the hilar structures were isolated and separately sectioned. RESULTS: The procedures performed were as follows: surgical biopsy, 98; wedge resection, 412; segmentectomy, 15; lobectomy, 217; pneumonectomy, 1. Besides the cases in which there were intraoperative complications that could be resolved thoracoscopically, it was necessary to convert to open surgery in 80 patients (10.8%): in 24 (3.3%), for general reasons linked to the technique of VATS itself; in 56 (7.5%), for specific causes correlated to the type of exeresis. The overall postoperative morbidity rate was 8.3% with no deaths. CONCLUSIONS: The analysis of the literature and our experience show that VATS is a reliable approach to the diagnosis and treatment of pulmonary diseases with low complication rate. To further reduce intraoperative and postoperative morbidity, however, it is necessary to select the patients carefully, to adhere strictly to oncological surgical principles, and to adopt a meticulous technique. Although conversion to open surgery represents failure of VATS, it is mandatory when the procedure is not completely safe.


Assuntos
Pneumopatias/cirurgia , Pneumonectomia/efeitos adversos , Pneumonectomia/métodos , Cirurgia Torácica Vídeoassistida/efeitos adversos , Humanos , Complicações Intraoperatórias/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Fatores de Tempo
15.
Transplant Proc ; 40(6): 1941-3, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18675095

RESUMO

The incidence and clinical consequences of hepatic injuries (parenchymal, vascular, and biliary) due to surgical handling during multiorgan procurement are still underestimated. Surgical damage to liver grafts may lead to an increased mortality and graft dysfunction rate; therefore, multiorgan procurements require a high level of expertise and training. We report our experience in two cases of accidental venous outflow damage during liver procurement focusing on our repair strategies. In one case, a short suprahepatic inferior vena cava (IVC) was extended by a venous cuff obtained from a long infrahepatic IVC from the same liver graft. In the second case, we observed a complete transection of the middle hepatic vein during in situ splitting procedure. The damage was reconstructed by cadaveric iliac vein interposition. In both cases, liver transplantation was successfully performed without venous complication. An adequate surgical technique in liver procurement and venous reconstruction during living donor and domino liver transplantation are formidable tools to achieve successful liver transplantation with a damaged graft.


Assuntos
Transplante de Fígado/métodos , Transplante de Fígado/patologia , Fígado/patologia , Obtenção de Tecidos e Órgãos/métodos , Veia Cava Inferior/lesões , Veia Cava Inferior/cirurgia , Cadáver , Humanos , Doadores de Tecidos , Resultado do Tratamento
16.
Transplant Proc ; 40(6): 1976-8, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18675105

RESUMO

AIM: The shortage of organs for orthotopic liver transplantation (OLT) has forced transplantation centers to expand the donor pool by using donors traditionally labeled as "extended criteria donors." One such example is OLT using a donor with advanced age. MATERIALS AND METHODS: We retrospectively evaluated 10 patients who received a liver graft from cadaveric donors older than 80 years. We analyzed pretransplantation donor and recipient characteristics, as well as the evolution of the recipients. RESULTS: All 10 donors were older than 80 years (median age, 83.5; range, 80-93). No steatosis (>30%) was accepted in the older donor group. Medium follow-up was 19.5 months. The most frequent cause for OLT was hepatitis C virus (HCV) cirrhosis (8/10 patients). We had 1 case of primary nonfunction, 1 patient died immediately after surgery because of extrahepatic complications (cardiac arrest), and 2 other patients had a severe HCV recurrence and died after 1 and 2 years from OLT, respectively. Five patients had HCV recurrence and biliary complications were present in 60% of the patients. No cases of acute or chronic rejection were described. Overall survival rates after 1 and 3 years were 80% and 40%, respectively. CONCLUSIONS: Old donor age is not an absolute contraindication to OLT. Liver grafts from donors older than 80 years can be used knowing that there is a high risk of postoperative complications. Furthermore, the increased risk of developing severe HCV recurrence, related to older donor age, suggests that such livers should be used in HCV-negative recipients.


Assuntos
Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/cirurgia , Neoplasias Hepáticas/cirurgia , Transplante de Fígado/mortalidade , Transplante de Fígado/estatística & dados numéricos , Doadores Vivos/estatística & dados numéricos , Adulto , Idoso , Carcinoma Hepatocelular/virologia , Feminino , Sobrevivência de Enxerto , Hepatite B/cirurgia , Hepatite C/cirurgia , Hepatite D/cirurgia , Humanos , Neoplasias Hepáticas/virologia , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Estudos Retrospectivos , Análise de Sobrevida , Fatores de Tempo
17.
J Breath Res ; 12(4): 046004, 2018 07 30.
Artigo em Inglês | MEDLINE | ID: mdl-29984708

RESUMO

A reliable method for the determination of carbonyl compounds in exhaled breath based on on-sorbent derivatization coupled with thermal desorption and gas chromatography-tandem mass spectrometry is described. The analytical performances were optimized for a mixture of C2-C9 aldehydes and C3-C9 ketones, particularly interesting for clinical applications, by using an internal standard and applying a 23 full factorial design. A volume of sample (250 ml) was loaded at 50 ml min-1 into a Tenax GR sorbent tube containing 130 nmol of O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine hydrochloride. All compounds showed a limit of detection lower than 200 pptv. The yield of the derivatization procedure was normalized by adding to the sample a known amount of 6D-acetone as an internal standard. This allowed halving the relative standard deviation to 10% and 15% for the mono-and di-carbonyl compounds, respectively, thus improving reliability. The optimized method was applied to the determination of carbonyl compounds in 12 breath samples collected from four patients suffering from heart failure during hospitalization.


Assuntos
Testes Respiratórios/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Espectrometria de Massas em Tandem/métodos , Temperatura , Calibragem , Insuficiência Cardíaca/diagnóstico , Humanos , Limite de Detecção , Modelos Lineares , Peso Molecular , Reprodutibilidade dos Testes
18.
Biosens Bioelectron ; 22(11): 2624-8, 2007 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-17169548

RESUMO

An impedentiometric electronic tongue based on the combination of a composite sensor array and chemometric techniques aimed at the discrimination of soluble compounds able to elicit different gustative perceptions is presented. A composite array consisting of chemo-sensitive layers based on carbon nanotubes or carbon black dispersed in polymeric matrices and doped polythiophenes was used. The electrical impedance of the sensor array was measured at a frequency of 150 Hz by means of an impedance meter. The experimental set-up was designed in order to allow the automatic selection of a test solution and dipping of the sensor array following a dedicated measurement protocol. Measurements were carried out on 15 different solutions eliciting 5 different tastes (sodium chloride, citric acid, glucose, glutamic acid and sodium dehydrocholate for salty, sour, sweet, umami and bitter, respectively) at 3 concentration levels comprising the human perceptive range. In order to avoid over-fitting, more than 100 repetitions for each sample were carried in a 4-month period. Principal component analysis (PCA) was used to detect and remove outliers. Classification was performed by linear discriminant analysis (LDA). A fairly good degree of discrimination was obtained.


Assuntos
Materiais Biomiméticos , Técnicas Biossensoriais/instrumentação , Eletroquímica/instrumentação , Análise de Alimentos/instrumentação , Reconhecimento Automatizado de Padrão/métodos , Paladar , Língua , Inteligência Artificial , Análise Discriminante , Impedância Elétrica , Eletroquímica/métodos , Eletrônica , Desenho de Equipamento , Análise de Falha de Equipamento , Análise de Alimentos/métodos , Integração de Sistemas , Transdutores
19.
Biosens Bioelectron ; 22(11): 2618-23, 2007 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-17161944

RESUMO

A study aimed at the characterization of five compounds with different chemical characteristics and gustative perceptions by measuring the variations of the electrical impedance of a composite sensor array is presented. The array was composed of five sensors of three different types based on carbon nanotubes or carbon black dispersed in polymeric matrices and doped polythiophenes. Measurements were carried out by evaluating the electrical impedance of the sensor array at a frequency of 150 Hz, and the data acquisition process was automated; a mechanical arm and a rotating platform controlled by a data acquisition card and a dedicated software allowed the sequential dipping of sensors in the test solutions. Fifty different solutions eliciting the 5 basic tastes (sodium chloride, citric acid, glucose, glutamic acid and sodium dehydrocholate for salty, sour, sweet, umami and bitter, respectively) at 10 concentration levels comprising the human perceptive range were analysed. More than 100 measurements were carried for each sample in a 4-month period to evaluate the system repeatability and robustness. The impedentiometric composite sensor array is shown to be sensitive, selective and stable for use in an electronic tongue.


Assuntos
Materiais Biomiméticos , Técnicas Biossensoriais/instrumentação , Eletroquímica/instrumentação , Análise de Alimentos/instrumentação , Paladar , Língua , Impedância Elétrica , Eletroquímica/métodos , Eletrônica , Desenho de Equipamento , Análise de Falha de Equipamento , Análise de Alimentos/métodos , Integração de Sistemas , Transdutores
20.
J Breath Res ; 11(4): 047110, 2017 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-29052557

RESUMO

The analytical performances of needle trap micro-extraction (NTME) coupled with gas chromatography-tandem mass spectrometry were evaluated by analyzing a mixture of twenty-two representative breath volatile organic compounds (VOCs) belonging to different chemical classes (i.e. hydrocarbons, ketones, aldehydes, aromatics and sulfurs). NTME is an emerging technique that guarantees detection limits in the pptv range by pre-concentrating low volumes of sample, and it is particularly suitable for breath analysis. For most VOCs, detection limits between 20 and 500 pptv were obtained by pre-concentrating 25 ml of a humidified standard gas mixture at a flow rate of 15 ml min-1. For all compounds, inter- and intra-day precisions were always below 15%, confirming the reliability of the method. The procedure was successfully applied to the analysis of exhaled breath samples collected from forty heart failure (HF) patients during their stay in the University Hospital of Pisa. The majority of patients (about 80%) showed a significant decrease of breath acetone levels (a factor of 3 or higher) at discharge compared to admission (acute phase) in correspondence to the improved clinical conditions during hospitalization, thus making this compound eligible as a biomarker of HF exacerbation.


Assuntos
Testes Respiratórios/instrumentação , Testes Respiratórios/métodos , Expiração , Cromatografia Gasosa-Espectrometria de Massas/métodos , Insuficiência Cardíaca/diagnóstico , Agulhas , Compostos Orgânicos Voláteis/análise , Adulto , Idoso , Idoso de 80 Anos ou mais , Dióxido de Carbono/análise , Feminino , Humanos , Limite de Detecção , Masculino , Pessoa de Meia-Idade , Análise de Componente Principal , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA