Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Clin Chem Lab Med ; 62(6): 1080-1091, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38205643

RESUMO

OBJECTIVES: Current liquid chromatography-tandem mass spectrometry (LC-MS/MS) applications for circulating androgen measurements are technically diverse. Previously, variable results have been reported for testosterone. Data are scarce for androstenedione and absent for dehydroepiandrosterone sulfate (DHEAS). We assessed the agreement of androstenedione, DHEAS and testosterone LC-MS/MS measurements among nine European centers and explored benefits of calibration system unification. METHODS: Androgens were measured twice by laboratory-specific procedures in 78 patient samples and in EQA materials. Results were obtained by in-house and external calibration. Intra- and inter-laboratory performances were valued. RESULTS: Intra-laboratory CVs ranged between 4.2-13.2 % for androstenedione, 1.6-10.8 % for DHEAS, and 4.3-8.7 % and 2.6-7.1 % for female and male testosterone, respectively. Bias and trueness in EQA materials were within ±20 %. Median inter-laboratory CV with in-house vs. external calibration were 12.0 vs. 9.6 % for androstenedione (p<0.001), 7.2 vs. 4.9 % for DHEAS (p<0.001), 6.4 vs. 7.6 % for female testosterone (p<0.001) and 6.8 and 7.4 % for male testosterone (p=0.111). Median bias vs. all laboratory median with in-house and external calibration were -13.3 to 20.5 % and -4.9 to 18.7 % for androstenedione, -10.9 to 4.8 % and -3.4 to 3.5 % for DHEAS, -2.7 to 6.5 % and -11.3 to 6.6 % for testosterone in females, and -7.0 to 8.5 % and -7.5 to 11.8 % for testosterone in males, respectively. CONCLUSIONS: Methods showed high intra-laboratory precision but variable bias and trueness. Inter-laboratory agreement was remarkably good. Calibration system unification improved agreement in androstenedione and DHEAS, but not in testosterone measurements. Multiple components, such as commutability of calibrators and EQA materials and internal standard choices, likely contribute to inter-laboratory variability.


Assuntos
Androstenodiona , Sulfato de Desidroepiandrosterona , Testosterona , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Androstenodiona/sangue , Androstenodiona/análise , Calibragem , Sulfato de Desidroepiandrosterona/sangue , Sulfato de Desidroepiandrosterona/análise , Sulfato de Desidroepiandrosterona/normas , Espectrometria de Massa com Cromatografia Líquida/métodos , Espectrometria de Massa com Cromatografia Líquida/normas , Espectrometria de Massas em Tandem/normas , Espectrometria de Massas em Tandem/métodos , Testosterona/sangue , Testosterona/análise , Testosterona/normas
2.
Support Care Cancer ; 32(9): 579, 2024 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-39115709

RESUMO

PURPOSE: Haematology patients with high-risk neutropenia are prone to mucosal-barrier injury-associated laboratory-confirmed bloodstream infections (MBI-LCBI). We assessed risk factors for MBI-LCBI including candidaemia in neutropenic haematology patients with fever. METHODS: This prospective observational study was performed in six dedicated haematology units in the Netherlands. Eligible haematology patients had neutropenia < 500/mL for ≥ 7 days and had fever. MBI-LCBIs were classified according to Centers for Disease Control (CDC) definitions and were followed until the end of neutropenia > 500/mL or discharge. RESULTS: We included 416 patients from December 2014 until August 2019. We observed 63 MBI-LCBIs. Neither clinical mucositis scores nor the blood level of citrulline at fever onset was associated with MBI-LCBI. In the multivariable analysis, MASCC-score (odds ratio [OR] 1.16, 95% confidence interval [CI] 1.05 to 1.29 per point decrease), intensive chemotherapy (OR 3·81, 95% CI 2.10 to 6.90) and Pichia kudriavzevii (formerly Candida krusei) colonisation (OR 5.40, 95% CI 1.75 to 16.7) were retained as risk factors for MBI-LCBI, while quinolone use seemed protective (OR 0.42, 95% CI 0.20 to 0.92). Citrulline level (OR 1.57, 95% CI 1.07 to 2.31 per µmol/L decrease), active chronic obstructive pulmonary disease (OR 15.4, 95% CI 1.61 to 14.7) and colonisation with fluconazole-resistant Candida (OR 8.54, 95% CI 1.51 to 48.4) were associated with candidaemia. CONCLUSION: In haematology patients with fever during neutropenia, hypocitrullinaemia at fever onset was associated with candidaemia, but not with bacterial MBI-LCBI. Patients with intensive chemotherapy with a low MASCC-score and colonisation with Pichia kudriavzevii had the highest risk of MBI-LCBI. TRIAL REGISTRATION: ClinicalTrials.gov (NCT02149329) at 19-NOV-2014.


Assuntos
Febre , Mucosite , Neutropenia , Humanos , Masculino , Feminino , Estudos Prospectivos , Pessoa de Meia-Idade , Fatores de Risco , Mucosite/etiologia , Neutropenia/etiologia , Neutropenia/complicações , Idoso , Febre/etiologia , Adulto , Países Baixos , Índice de Gravidade de Doença , Candidemia/etiologia , Candidemia/epidemiologia , Neoplasias Hematológicas/complicações
3.
Clin Chem Lab Med ; 61(1): 67-77, 2023 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-36288389

RESUMO

OBJECTIVES: Liquid chromatography-tandem mass spectrometry (LC-MS/MS) panels that include glucocorticoid-related steroids are increasingly used to characterize and diagnose adrenal cortical diseases. Limited information is currently available about reproducibility of these measurements among laboratories. The aim of the study was to compare LC-MS/MS measurements of corticosterone, 11-deoxycortisol and cortisone at eight European centers and assess the performance after unification of calibration. METHODS: Seventy-eight patient samples and commercial calibrators were measured twice by laboratory-specific procedures. Results were obtained according to in-house and external calibration. We evaluated intra-laboratory and inter-laboratory imprecision, regression and agreement against performance specifications derived from 11-deoxycortisol biological variation. RESULTS: Intra-laboratory CVs ranged between 3.3 and 7.7%, 3.3 and 11.8% and 2.7 and 12.8% for corticosterone, 11-deoxycortisol and cortisone, with 1, 4 and 3 laboratories often exceeding the maximum allowable imprecision (MAI), respectively. Median inter-laboratory CVs were 10.0, 10.7 and 6.2%, with 38.5, 50.7 and 2.6% cases exceeding the MAI for corticosterone, 11-deoxycortisol and cortisone, respectively. Median laboratory bias vs. all laboratory-medians ranged from -5.6 to 12.3% for corticosterone, -14.6 to 12.4% for 11-deoxycortisol and -4.0 to 6.5% for cortisone, with few cases exceeding the total allowable error. Modest deviations were found in regression equations among most laboratories. External calibration did not improve 11-deoxycortisol and worsened corticosterone and cortisone inter-laboratory comparability. CONCLUSIONS: Method imprecision was variable. Inter-laboratory performance was reasonably good. However, cases with imprecision and total error above the acceptable limits were apparent for corticosterone and 11-deoxycortisol. Variability did not depend on calibration but apparently on imprecision, accuracy and specificity of individual methods. Tools for improving selectivity and accuracy are required to improve harmonization.


Assuntos
Cortisona , Humanos , Cromatografia Líquida/métodos , Cortodoxona , Corticosterona , Espectrometria de Massas em Tandem/métodos , Reprodutibilidade dos Testes
4.
Clin Chem Lab Med ; 60(5): 726-739, 2022 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-35172417

RESUMO

OBJECTIVES: Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is recommended for measuring circulating steroids. However, assays display technical heterogeneity. So far, reproducibility of corticosteroid LC-MS/MS measurements has received scant attention. The aim of the study was to compare LC-MS/MS measurements of cortisol, 17OH-progesterone and aldosterone from nine European centers and assess performance according to external quality assessment (EQA) materials and calibration. METHODS: Seventy-eight patient samples, EQA materials and two commercial calibration sets were measured twice by laboratory-specific procedures. Results were obtained by in-house (CAL1) and external calibrations (CAL2 and CAL3). We evaluated intra and inter-laboratory imprecision, correlation and agreement in patient samples, and trueness, bias and commutability in EQA materials. RESULTS: Using CAL1, intra-laboratory CVs ranged between 2.8-7.4%, 4.4-18.0% and 5.2-22.2%, for cortisol, 17OH-progesterone and aldosterone, respectively. Trueness and bias in EQA materials were mostly acceptable, however, inappropriate commutability and target value assignment were highlighted in some cases. CAL2 showed suboptimal accuracy. Median inter-laboratory CVs for cortisol, 17OH-progesterone and aldosterone were 4.9, 11.8 and 13.8% with CAL1 and 3.6, 10.3 and 8.6% with CAL3 (all p<0.001), respectively. Using CAL1, median bias vs. all laboratory-medians ranged from -6.6 to 6.9%, -17.2 to 7.8% and -12.0 to 16.8% for cortisol, 17OH-progesterone and aldosterone, respectively. Regression lines significantly deviated from the best fit for most laboratories. Using CAL3 improved cortisol and 17OH-progesterone between-method bias and correlation. CONCLUSIONS: Intra-laboratory imprecision and performance with EQA materials were variable. Inter-laboratory performance was mostly within specifications. Although residual variability persists, adopting common traceable calibrators and RMP-determined EQA materials is beneficial for standardization of LC-MS/MS steroid measurements.


Assuntos
Hidrocortisona , Progesterona , Aldosterona , Calibragem , Cromatografia Líquida/métodos , Humanos , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/métodos
5.
Anal Bioanal Chem ; 414(1): 333-349, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34432104

RESUMO

An interlaboratory comparison study was conducted by the Vitamin D Standardization Program (VDSP) to assess the performance of liquid chromatography - tandem mass spectrometry (LC-MS/MS) assays used for the determination of serum total 25-hydroxyvitamin D (25(OH)D), which is the sum of 25-hydroxyvitamin D2 (25(OH)D2) and 25-hydroxyvitamin D3 (25(OH)D3). A set of 50 single-donor samples was assigned target values for concentrations of 25(OH)D2, 25(OH)D3, 3-epi-25-hydroxyvitamin D3 (3-epi-25(OH)D3), and 24R,25-dihydroxyvitamin D3 (24R,25(OH)2D3) using isotope dilution liquid chromatography - tandem mass spectrometry (ID LC-MS/MS). VDSP Intercomparison Study 2 Part 1 includes results from 14 laboratories using 14 custom LC-MS/MS assays. Assay performance was evaluated using mean % bias compared to the assigned target values and using linear regression analysis of the test assay mean results and the target values. Only 53% of the LC-MS/MS assays met the VDSP criterion of mean % bias ≤ |±5%|. For the LC-MS/MS assays not meeting the ≤ |±5%| criterion, four assays had mean % bias of between 12 and 21%. Based on multivariable regression analysis using the concentrations of the four individual vitamin D metabolites in the 50 single-donor samples, the performance of several LC-MS/MS assays was found to be influenced by the presence of 3-epi-25(OH)D3. The results of this interlaboratory study represent the most comprehensive comparison of LC-MS/MS assay performance for serum total 25(OH)D and document the significant impact of the lack of separation of 3-epi-25(OH)D3 and 25(OH)D3 on assay performance, particularly with regard to mean % bias.


Assuntos
Espectrometria de Massas em Tandem , Vitamina D , 25-Hidroxivitamina D 2 , Cromatografia Líquida/métodos , Padrões de Referência , Espectrometria de Massas em Tandem/métodos , Vitamina D/análogos & derivados
6.
Anal Bioanal Chem ; 414(2): 1015-1028, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34750644

RESUMO

The Vitamin D External Quality Assessment Scheme (DEQAS) distributes human serum samples four times per year to over 1000 participants worldwide for the determination of total serum 25-hydroxyvitamin D [25(OH)D)]. These samples are stored at -40 °C prior to distribution and the participants are instructed to store the samples frozen at -20 °C or lower after receipt; however, the samples are shipped to participants at ambient conditions (i.e., no temperature control). To address the question of whether shipment at ambient conditions is sufficient for reliable performance of various 25(OH)D assays, the equivalence of DEQAS human serum samples shipped under frozen and ambient conditions was assessed. As part of a Vitamin D Standardization Program (VDSP) commutability study, two sets of the same nine DEQAS samples were shipped to participants at ambient temperature and frozen on dry ice. Twenty-eight laboratories participated in this study and provided 34 sets of results for the measurement of 25(OH)D using 20 ligand binding assays and 14 liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods. Equivalence of the assay response for the frozen versus ambient DEQAS samples for each assay was evaluated using multi-level modeling, paired t-tests including a false discovery rate (FDR) approach, and ordinary least squares linear regression analysis of frozen versus ambient results. Using the paired t-test and confirmed by FDR testing, differences in the results for the ambient and frozen samples were found to be statistically significant at p < 0.05 for four assays (DiaSorin, DIAsource, Siemens, and SNIBE prototype). For all 14 LC-MS/MS assays, the differences in the results for the ambient- and frozen-shipped samples were not found to be significant at p < 0.05 indicating that these analytes were stable during shipment at ambient conditions. Even though assay results have been shown to vary considerably among different 25(OH)D assays in other studies, the results of this study also indicate that sample handling/transport conditions may influence 25(OH)D assay response for several assays.


Assuntos
Congelamento , Vitamina D/análogos & derivados , Vitamina D/sangue , Cromatografia Líquida/métodos , Humanos , Espectrometria de Massas em Tandem/métodos
7.
Clin Infect Dis ; 73(11): e4039-e4046, 2021 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-32852539

RESUMO

BACKGROUND: Respiratory failure and thromboembolism are frequent in severe acute respiratory syndrome coronavirus 2-infected patients. Vitamin K activates both hepatic coagulation factors and extrahepatic endothelial anticoagulant protein S, required for thrombosis prevention. In times of vitamin K insufficiency, hepatic procoagulant factors are preferentially activated over extrahepatic proteins. Vitamin K also activates matrix Gla protein (MGP), which protects against pulmonary and vascular elastic fiber damage. We hypothesized that vitamin K may be implicated in coronavirus disease 2019 (COVID-19), linking pulmonary and thromboembolic disease. METHODS: A total of 135 hospitalized COVID-19 patients were compared with 184 historic controls. Inactive vitamin K-dependent MGP (desphospho-uncarboxylated [dp-uc] MGP) and prothrombin (PIVKA-II) were measured inversely related to extrahepatic and hepatic vitamin K status, respectively. Desmosine was measured to quantify the rate of elastic fiber degradation. Arterial calcification severity was assessed using computed tomography. RESULTS: dp-ucMGP was elevated in COVID-19 patients compared with controls (P < .001), with even higher dp-ucMGP in patients with poor outcomes (P < .001). PIVKA-II was normal in 82.1% of patients. dp-ucMGP was correlated with desmosine (P < .001) and with coronary artery (P = .002) and thoracic aortic (P < .001) calcification scores. CONCLUSIONS: dp-ucMGP was severely increased in COVID-19 patients, indicating extrahepatic vitamin K insufficiency, which was related to poor outcome; hepatic procoagulant factor II remained unaffected. These data suggest pneumonia-induced extrahepatic vitamin K depletion leading to accelerated elastic fiber damage and thrombosis in severe COVID-19 due to impaired activation of MGP and endothelial protein S, respectively.


Assuntos
COVID-19 , Biomarcadores , Humanos , Fatores de Risco , SARS-CoV-2 , Vitamina K 1/análogos & derivados
8.
Anal Bioanal Chem ; 413(20): 5067-5084, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34184102

RESUMO

An interlaboratory study was conducted through the Vitamin D Standardization Program (VDSP) to assess commutability of Standard Reference Materials® (SRMs) and proficiency testing/external quality assessment (PT/EQA) samples for determination of serum total 25-hydroxyvitamin D [25(OH)D] using ligand binding assays and liquid chromatography-tandem mass spectrometry (LC-MS/MS). A set of 50 single-donor serum samples were assigned target values for 25-hydroxyvitamin D2 [25(OH)D2] and 25-hydroxyvitamin D3 [25(OH)D3] using reference measurement procedures (RMPs). SRM and PT/EQA samples evaluated included SRM 972a (four levels), SRM 2973, six College of American Pathologists (CAP) Accuracy-Based Vitamin D (ABVD) samples, and nine Vitamin D External Quality Assessment Scheme (DEQAS) samples. Results were received from 28 different laboratories using 20 ligand binding assays and 14 LC-MS/MS methods. Using the test assay results for total serum 25(OH)D (i.e., the sum of 25(OH)D2 and 25(OH)D3) determined for the single-donor samples and the RMP target values, the linear regression and 95% prediction intervals (PIs) were calculated. Using a subset of 42 samples that had concentrations of 25(OH)D2 below 30 nmol/L, one or more of the SRM and PT/EQA samples with high concentrations of 25(OH)D2 were deemed non-commutable using 5 of 11 unique ligand binding assays. SRM 972a (level 4), which has high exogenous concentration of 3-epi-25(OH)D3, was deemed non-commutable for 50% of the LC-MS/MS assays.


Assuntos
Sociedades Médicas/normas , Vitamina D/análogos & derivados , Vitamina D/química , Humanos , Padrões de Referência , Manejo de Espécimes , Vitamina D/sangue
9.
Acta Neurol Scand ; 141(1): 77-80, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31657006

RESUMO

OBJECTIVES: Low circulating vitamin D levels are associated with an increased risk of active MRI lesions and relapses in several cohorts with relapsing remitting multiple sclerosis (RRMS). Randomized controlled supplementation trials are, however, negative on their primary endpoints, while secondary MRI endpoints suggest anti-inflammatory effects. Circulating levels of neurofilament light chain (NfL) are a biomarker of disease activity in RRMS. We explored whether 48-week high-dose vitamin D3 supplements were associated with lower circulating NfL levels. MATERIALS & METHODS: Of N = 40 Dutch interferon beta-treated participants with RRMS of the SOLAR trial, plasma samples at baseline and 48-week follow-up were available. Of these participants, N = 24 were supplemented with 14 000 IU/d vitamin D3 and N = 16 with placebo. Twenty-five hydroxyvitamin D3 (25(OH)D3 ) levels were measured with LC-MS/MS, and NfL levels were measured in duplicate with Simoa. RESULTS: Serum 25(OH)D3 levels at 48 weeks were increased in the vitamin D3 when compared to placebo group (median level 281 [IQR 205-330] vs 72 [39-88] nmol/L; P < .01). NfL levels at 48 weeks did not differ between the treatment groups (median level 25.4 [IQR 19.6-32.2] vs 25.3 [17.9-30.1] pg/mL; P = .74). Higher week 48 NfL level showed a trend toward association with a higher risk of combined unique active lesions on the week 48 MRI scan (OR 2.39 [95% CI 0.93-6.12] for each 10 pg/mL increase; P = .07). CONCLUSIONS: Supplementation of high-dose vitamin D3 for 48 weeks was not associated with lower NfL levels. This study does not support an effect of vitamin D3 on this biomarker of neuro-axonal injury.


Assuntos
Colecalciferol/uso terapêutico , Suplementos Nutricionais , Esclerose Múltipla Recidivante-Remitente/sangue , Proteínas de Neurofilamentos/sangue , Vitamina D/sangue , Adjuvantes Imunológicos/uso terapêutico , Adulto , Biomarcadores/sangue , Método Duplo-Cego , Feminino , Humanos , Interferon beta-1a/uso terapêutico , Masculino , Esclerose Múltipla Recidivante-Remitente/tratamento farmacológico
10.
Int J Cancer ; 142(6): 1189-1201, 2018 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-29114875

RESUMO

Evidence from in vivo, in vitro and ecological studies are suggestive of a protective effect of vitamin D against pancreatic cancer (PC). However, this has not been confirmed by analytical epidemiological studies. We aimed to examine the association between pre-diagnostic circulating vitamin D concentrations and PC incidence in European populations. We conducted a pooled nested case-control study within the European Prospective Investigation into Cancer and Nutrition (EPIC) and the Nord-Trøndelag Health Study's second survey (HUNT2) cohorts. In total, 738 primary incident PC cases (EPIC n = 626; HUNT2 n = 112; median follow-up = 6.9 years) were matched to 738 controls. Vitamin D [25(OH)D2 and 25(OH)D3 combined] concentrations were determined using isotope-dilution liquid chromatography-tandem mass spectrometry. Conditional logistic regression models with adjustments for body mass index and smoking habits were used to estimate incidence rate ratios (IRRs) and 95% confidence intervals (95%CI). Compared with a reference category of >50 to 75 nmol/L vitamin D, the IRRs (95% CIs) were 0.71 (0.42-1.20); 0.94 (0.72-1.22); 1.12 (0.82-1.53) and 1.26 (0.79-2.01) for clinically pre-defined categories of ≤25; >25 to 50; >75 to 100; and >100 nmol/L vitamin D, respectively (p for trend = 0.09). Corresponding analyses by quintiles of season-standardized vitamin D concentrations also did not reveal associations with PC risk (p for trend = 0.23). Although these findings among participants from the largest combination of European cohort studies to date show increasing effect estimates of PC risk with increasing pre-diagnostic concentrations of vitamin D, they are not statistically significant.


Assuntos
25-Hidroxivitamina D 2/sangue , Calcifediol/sangue , Neoplasias Pancreáticas/epidemiologia , Idoso , Estudos de Casos e Controles , Europa (Continente) , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Neoplasias Pancreáticas/sangue , Estudos Prospectivos , Medição de Risco , Estações do Ano
11.
Respir Res ; 19(1): 45, 2018 03 20.
Artigo em Inglês | MEDLINE | ID: mdl-29558926

RESUMO

Although chronic obstructive pulmonary disease (COPD) and idiopathic pulmonary fibrosis (IPF) seem to be opposite entities from a clinical perspective, common initial pathogenic steps have been suggested in both lung diseases. Emphysema is caused by an elastase/anti-elastase imbalance leading to accelerated elastin degradation. Elastinolysis is however, also accelerated in the IPF patients' lungs. The amino acids desmosine and isodesmosine (DES) are unique to elastin. During the degradation process, elastases liberate DES from elastin fibers. Blood DES levels consequently reflect the rate of systemic elastinolysis and are increased in COPD. This is the first report describing elevated DES levels in IPF patients. We also demonstrated that the age-related increment of DES concentrations is enhanced in IPF. Our current study suggests that elastinolysis is a shared pathogenic step in both COPD and IPF. Further investigation is required to establish the relevance of accelerated elastin degradation in IPF and to determine whether decelerating this process leads to slower progression of lung fibrosis and better survival for patients with IPF.


Assuntos
Envelhecimento/sangue , Envelhecimento/patologia , Desmosina/sangue , Elastina/metabolismo , Fibrose Pulmonar Idiopática/sangue , Fibrose Pulmonar Idiopática/diagnóstico , Idoso , Biomarcadores/sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doença Pulmonar Obstrutiva Crônica/sangue , Doença Pulmonar Obstrutiva Crônica/diagnóstico
14.
J Clin Med ; 13(12)2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38930004

RESUMO

Background: In observational studies, high levels of desphospho-uncarboxylated matrix gla protein (dp-ucMGP) that result from vitamin K deficiency were consistently associated with poor clinical outcomes during COVID-19. Vitamin K-activated matrix gla protein (MGP) is required to protect against elastic fibre degradation, and a deficiency may contribute to pathology. However, intervention trials assessing the effects of vitamin K supplementation in COVID-19 are lacking. Methods: This is a single-centre, phase 2, double-blind, randomised, placebo-controlled trial investigating the effects of vitamin K2 supplementation in 40 hospitalised COVID-19 patients requiring supplemental oxygen. Individuals were randomly assigned in a 1:1 ratio to receive 999 mcg of vitamin K2-menaquinone-7 (MK-7)-or a placebo daily until discharge or for a maximum of 14 days. Dp-ucMGP, the rate of elastic fibre degradation quantified by desmosine, and hepatic vitamin K status quantified by PIVKA-II were measured. Grade 3 and 4 adverse events were collected daily. As an exploratory objective, circulating vitamin K2 levels were measured. Results: Vitamin K2 was well tolerated and did not increase the number of adverse events. A linear mixed model analysis showed that dp-ucMGP and PIVKA-II decreased significantly in subjects that received supplementation compared to the controls (p = 0.008 and p = 0.0017, respectively), reflecting improved vitamin K status. The decrease in dp-ucMGP correlated with higher plasma MK-7 levels (p = 0.015). No significant effect on desmosine was found (p = 0.545). Conclusions: These results demonstrate that vitamin K2 supplementation during COVID-19 is safe and decreases dp-ucMGP. However, the current dose of vitamin K2 failed to show a protective effect against elastic fibre degradation.

15.
Front Nutr ; 9: 868324, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35356738

RESUMO

[This corrects the article DOI: 10.3389/fnut.2021.761191.].

16.
PLoS One ; 16(12): e0261097, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34855907

RESUMO

INTRODUCTION: A poor 25-hydroxyvitamin D (25(OH)D) status is a much replicated risk factor for developing multiple sclerosis (MS), and several vitamin D-associated single nucleotide polymorphisms (SNPs) have been associated with a higher risk of MS. However, studies on the benefit of vitamin D supplementation in MS show inconclusive results. Here, we explore whether vitamin D-associated SNPs and MS risk alleles confound serological response to vitamin D supplementation. METHODS: 34 participants from the SOLARIUM study consented to genotyping, of which 26 had vitamin D data available. The SOLARIUM study randomised relapsing-remitting MS patients to placebo or 14,000 IU vitamin D3 for 48 weeks. Participants were categorised as either 'carriers' or 'non-carriers' of the risk allele for 4 SNPs: two related to D binding protein (DBP) and associated with lower 25(OH)D levels (rs4588 and rs7041), and two related to vitamin D metabolism enzymes CYP27B1 and CYP24A1 and associated with a higher risk of MS (rs12368653; rs2248359, respectively). 25(OH)D levels were determined at baseline and after 48 weeks. RESULTS: The DBP-related SNPs showed no difference in 25(OH)D status at baseline, but carriers of the rs7041 risk allele showed lower 25(OH)D-levels compared to non-carriers after 48 weeks of supplementation (median 224.2 vs. 332.0 nmol/L, p = 0.013). For CYP related SNPs, neither showed a difference at baseline, but carriers of the rs12368653 risk allele showed higher 25(OH)D-levels compared to non-carriers after 48 weeks of supplementation (median 304.1 vs. 152.0 nmol/L, p = 0.014). DISCUSSION: Vitamin D-related SNPs affect the serological response to high-dose vitamin D supplementation. The effects on more common doses of vitamin D, as well as the clinical consequence of this altered response, need to be investigated further.


Assuntos
25-Hidroxivitamina D3 1-alfa-Hidroxilase/genética , Proteínas de Ligação a DNA/genética , Suplementos Nutricionais , Esclerose Múltipla Recidivante-Remitente/patologia , Fatores de Transcrição/genética , Vitamina D3 24-Hidroxilase/genética , Vitamina D/análogos & derivados , Adulto , Feminino , Genótipo , Humanos , Masculino , Pessoa de Meia-Idade , Esclerose Múltipla Recidivante-Remitente/sangue , Esclerose Múltipla Recidivante-Remitente/tratamento farmacológico , Polimorfismo de Nucleotídeo Único , Prognóstico , Vitamina D/administração & dosagem , Vitamina D/sangue
17.
Front Nutr ; 8: 761191, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35111793

RESUMO

BACKGROUND: Pathology during COVID-19 infection arises partly from an excessive inflammatory response with a key role for interleukin (IL)-6. Both vitamin D and K have been proposed as potential modulators of this process. METHODS: We assessed vitamin D and K status by measuring circulating 25-hydroxyvitamin D (25(OH)D) and desphospho-uncarboxylated Matrix Gla-Protein (dp-ucMGP), respectively in 135 hospitalized COVID-19 patients in relation to inflammatory response, elastic fiber degradation and clinical outcomes. RESULTS: Comparing good and poor disease outcomes of COVID-19 patients, vitamin 25(OH)D levels were not significantly different. IL-6 levels, however, were significantly higher in patients with poor outcome, compared to patients with good outcome (30.3 vs. 153.0 pg/mL; p < 0.0001). Dp-ucMGP levels as biomarker of extrahepatic vitamin K status was associated with IL-6 levels (r = 0.35; p < 0.0001). In contrast, 25(OH)D levels were only borderline statistically significant correlated with IL-6 (r = -0.14; p <0.050). A significant association was also found between IL-6 and elastic fiber degradation. Contrary to vitamin K status, 25(OH)D did not correlate with elastic fiber degradation. CONCLUSIONS: Dp-ucMGP associates with IL-6 as a central component of the destructive inflammatory processes in COVID-19. An intervention trial may provide insight whether vitamin K administration, either or not in combination with vitamin D, improves clinical outcome of COVID-19.

18.
Cancer Epidemiol Biomarkers Prev ; 30(4): 765-773, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33531437

RESUMO

BACKGROUND: Whether changes in 25 hydroxy vitamin D3 (25(OH)D3) levels after colorectal cancer diagnosis influence clinical outcomes is unclear. We investigated the association of trajectories of 25(OH)D3 levels with recurrence and all-cause mortality. METHODS: In total, 679 patients were included in our data analyses. Trajectories of 25(OH)D3 levels were defined on the basis of vitamin D status at diagnosis, at 6 months, and 2 years after diagnosis. Observed trajectories of 25(OH)D3 levels were consistent deficient levels (20%), consistent sufficient levels (39%), increasing levels (20%), and a temporary drop in levels (13%). Associations of trajectories of 25(OH)D3 with recurrence and all-cause mortality were assessed using multivariable Cox proportional hazards regression models. RESULTS: During a follow-up time of 2.2 years for recurrence and 3.5 years for all-cause mortality, 31 and 65 events occurred, respectively. No statistically significant associations were observed for vitamin D trajectories and the risk of recurrence. Patients who were consistently sufficient compared with patients who were consistently deficient had a lower risk of all-cause mortality [HR 0.39; 95% confidence interval (CI), 0.21-0.73]. The risk of all-cause mortality seems lower in patients with increasing levels or a temporary drop in levels (HR 0.54; 95% CI, 0.27-1.10 and HR 0.40 95% CI, 0.17-0.93) relative to patients with consistent deficient levels. CONCLUSIONS: Patients with colorectal cancer following a trajectory characterized by sufficient levels of 25(OH)D3 2 years after diagnosis all appeared to have a lower risk of all-cause mortality compared with patients having consistent deficient levels. IMPACT: Further studies should investigate how trajectories of 25(OH)D3 levels are associated with colorectal cancer recurrence.


Assuntos
Biomarcadores Tumorais/sangue , Neoplasias Colorretais/mortalidade , Vitamina D/análogos & derivados , Idoso , Causas de Morte , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Estudos Prospectivos , Risco , Vitamina D/sangue
19.
J Clin Med ; 9(9)2020 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-32859086

RESUMO

Pseudoxanthoma elasticum (PXE) results in extensive fragmentation and calcification of elastin fibers in the peripheral arteries, which results in peripheral arterial disease (PAD). Current research focuses on the role of calcifications in the pathogenesis of PXE. Elastin degradation and calcification are shown to interact and may amplify each other. This study aims to compare plasma desmosines, a measure of elastin degradation, between PXE patients and controls and to investigate the association between desmosines and (1) arterial calcification, (2) PAD, and (3) PAD independent of arterial calcification in PXE. Plasma desmosines were quantified with liquid chromatography-tandem mass spectrometry in 93 PXE patients and 72 controls. In PXE patients, arterial calcification mass was quantified on CT scans. The ankle brachial index (ABI) after treadmill test was used to analyze PAD, defined as ABI < 0.9, and the Fontaine classification was used to distinguish symptomatic and asymptomatic PAD. Regression models were built to test the association between desmosines and arterial calcification and arterial functioning in PXE. PXE patients had higher desmosines than controls (350 (290-410) ng/L vs. 320 (280-360) ng/L, p = 0.02). After adjustment for age, sex, body mass index, smoking, type 2 diabetes mellitus, and pulmonary abnormalities, desmosines were associated with worse ABI (ß (95%CI): -68 (-132; -3) ng/L), more PAD (ß (95%CI): 40 (7; 73) ng/L), and higher Fontaine classification (ß (95%CI): 30 (6; 53) ng/L), but not with arterial calcification mass. Lower ABI was associated with higher desmosines, independent from arterial calcification mass (ß (95%CI): -0.71(-1.39; -0.01)). Elastin degradation is accelerated in PXE patients compared to controls. The association between desmosines and ABI emphasizes the role of elastin degradation in PAD in PXE. Our results suggest that both elastin degradation and arterial calcification independently contribute to PAD in PXE.

20.
ERJ Open Res ; 6(4)2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33043047

RESUMO

BACKGROUND: Vitamin D supplementation lowers exacerbation frequency in severe vitamin D-deficient patients with COPD. Data regarding the effect of vitamin D on elastin degradation are lacking. Based on the vitamin's anti-inflammatory properties, we hypothesised that vitamin D supplementation reduces elastin degradation, particularly in vitamin D-deficient COPD patients. We assessed the effect of vitamin D status and supplementation on elastin degradation by measuring plasma desmosine, a biomarker of elastin degradation. METHODS: Desmosine was measured every 4 months in plasma of 142 vitamin D-naïve COPD patients from the Leuven vitamin D intervention trial (100 000 IU vitamin D3 supplementation every 4 weeks for 1 year). RESULTS: No significant association was found between baseline 25-hydroxyvitamin D (25(OH)D) and desmosine levels. No significant difference in desmosine change over time was found between the placebo and intervention group during the course of the trial. In the intervention arm, an unexpected inverse association was found between desmosine change and baseline 25(OH)D levels (p=0.005). CONCLUSIONS: Vitamin D supplementation did not have a significant overall effect on elastin degradation compared to placebo. Contrary to our hypothesis, the intervention decelerated elastin degradation in vitamin D-sufficient COPD patients and not in vitamin D-deficient subjects.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA