RESUMO
Neonatal jaundice (hyperbilirubinaemia) is common in neonates and, often, intensive blue-light phototherapy is required to prevent long-term effects. A photonic textile can overcome three major incubator-related concerns: Insulation of the neonate, human contact, and usage restraints. This paper describes the development of a homogeneous luminous textile from polymer optical fibres to use as a wearable, long-term phototherapy device. The bend out-coupling of light from the POFs was related to the weave production, e.g. weave pattern and yarn densities. Comfort, determined by friction against a skin model and breathability, was investigated additionally. Our textile is the first example of phototherapeutic clothing that is produced sans post-processing allowing for faster commercial production.
RESUMO
A miniature, directional fibre-optic acoustic source is presented that employs geometrical focussing to generate a nearly-collimated acoustic pencil beam. When paired with a fibre-optic acoustic detector, an all-optical ultrasound probe with an outer diameter of 2.5 mm is obtained that acquires a pulse-echo image line at each probe position without the need for image reconstruction. B-mode images can be acquired by translating the probe and concatenating the image lines, and artefacts resulting from probe positioning uncertainty are shown to be significantly lower than those observed for conventional synthetic aperture scanning of a non-directional acoustic source. The high image quality obtained for excised vascular tissue suggests that the all-optical ultrasound probe is ideally suited for in vivo, interventional applications.
RESUMO
An all-optical ultrasound probe for vascular tissue imaging was developed. Ultrasound was generated by pulsed laser illumination of a functionalized carbon nanotube composite coating on the end face of an optical fiber. Ultrasound was detected with a Fabry-Pérot (FP) cavity on the end face of an adjacent optical fiber. The probe diameter was < 0.84 mm and had an ultrasound bandwidth of ~20 MHz. The probe was translated across the tissue sample to create a virtual linear array of ultrasound transmit/receive elements. At a depth of 3.5 mm, the axial resolution was 64 µm and the lateral resolution was 88 µm, as measured with a carbon fiber target. Vascular tissues from swine were imaged ex vivo and good correspondence to histology was observed.
RESUMO
With a Gaussian-like broadband light source from high brightness Ce(3+):YAG single-clad crystal fiber, a full-field optical coherence tomography using a home-designed Mirau objective realized high quality images of in vivo and excised skin tissues. With a 40 × silicone-oil-immersion Mirau objective, the achieved spatial resolutions in axial and lateral directions were 0.9 and 0.51 µm, respectively. Such a high spatial resolution enables the separation of lamellar structure of the full epidermis in both the cross-sectional and en face planes. The number of layers of stratum corneum and its thickness were quantitatively measured. This label free and non-invasive optical probe could be useful for evaluating the water barrier of skin tissue in clinics. As a preliminary in vivo experiment, the blood vessel in dermis was also observed, and the flowing of the red blood cells and location of the melanocyte were traced.
RESUMO
A novel approach is presented for computing optode placements that are adapted to specific geometries and tissue characteristics, e.g., in optical tomography and photodynamic cancer therapy. The method is based on optimal control techniques together with a sparsity-promoting penalty that favors pointwise solutions, yielding both locations and magnitudes of light sources. In contrast to current discrete approaches, the need for specifying an initial set of candidate configurations as well as the exponential increase in complexity with the number of optodes are avoided. This is demonstrated with computational examples from photodynamic therapy.