Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.574
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Respir Res ; 25(1): 247, 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38890648

RESUMO

INTRODUCTION: Sleep-disordered breathing (SDB) is a major comorbidity in idiopathic pulmonary fibrosis (IPF) and is associated with a poor outcome. There is a lack of knowledge regarding the impact of SDB treatment on IPF. We assessed at one year: (1) the effect of CPAP and/or nocturnal oxygen therapy on IPF regarding lung function, blood mediators, and quality of life; (2) adherence to SDB treatment and SDB changes. METHODOLOGY: This is a prospective study of consecutive newly diagnosed IPF patients initiating anti-fibrotic treatment. Lung function, polysomnography, blood tests and quality of life questionnaires were performed at inclusion and after one year. Patients were classified as obstructive sleep apnoea (OSA), central sleep apnoea (CSA), and sleep-sustained hypoxemia (SSH). SDB therapy (CPAP and/or nocturnal oxygen therapy) was initiated if needed. RESULTS: Fifty patients were enrolled (36% had OSA, 22% CSA, and 12% SSH). CPAP was started in 54% of patients and nocturnal oxygen therapy in 16%. At one-year, polysomnography found improved parameters, though 17% of patients had to add nocturnal oxygen therapy or CPAP, while 33% presented SDB onset at this second polysomnography. CPAP compliance at one year was 6.74 h/night (SD 0.74). After one year, matrix metalloproteinase-1 decreased in OSA and CSA (p = 0.029; p = 0.027), C-reactive protein in OSA (p = 0.045), and surfactant protein D in CSA group (p = 0.074). There was no significant change in lung function. CONCLUSIONS: Treatment of SBD with CPAP and NOT can be well tolerated with a high compliance. IPF patients may exhibit SDB progression and require periodic re-assessment. Further studies to evaluate the impact of SDB treatment on lung function and serological mediators are needed.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Fibrose Pulmonar Idiopática , Oxigenoterapia , Síndromes da Apneia do Sono , Humanos , Pressão Positiva Contínua nas Vias Aéreas/métodos , Feminino , Masculino , Fibrose Pulmonar Idiopática/terapia , Fibrose Pulmonar Idiopática/complicações , Fibrose Pulmonar Idiopática/diagnóstico , Fibrose Pulmonar Idiopática/fisiopatologia , Projetos Piloto , Idoso , Estudos Prospectivos , Síndromes da Apneia do Sono/terapia , Síndromes da Apneia do Sono/diagnóstico , Síndromes da Apneia do Sono/fisiopatologia , Síndromes da Apneia do Sono/complicações , Oxigenoterapia/métodos , Pessoa de Meia-Idade , Resultado do Tratamento , Polissonografia/métodos , Qualidade de Vida
2.
Aging Male ; 27(1): 2317165, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38389408

RESUMO

BACKGROUND: Obstructive sleep apnea (OSA) is linked to various health complications, including erectile dysfunction (ED), which is more prevalent in individuals with OSA. This study explored ED in Korean OSA patients and assessed the impact of continuous positive airway pressure (CPAP) therapy on ED. METHODS: A total of 87 male patients with OSA from four different sleep centers underwent physical measurements and completed sleep and mental health (MH) questionnaires, including the Korean version of the International index of erectile function (IIEF), before and three months after initiating CPAP therapy. RESULTS: After three months of CPAP therapy, the patients demonstrated a significant improvement in ED as measured on the IIEF. However, the study found no significant correlation between the duration of CPAP use and the improvement in IIEF score. It did identify the SF36 quality of life assessment as a significant factor influencing ED improvement after CPAP. CONCLUSIONS: ED is a prevalent issue that escalates with age and is associated with OSA. CPAP therapy has shown potential in alleviating ED symptoms, particularly in those with underlying psychological conditions, although further research is required to confirm these findings and understand the underlying mechanisms.


Assuntos
Disfunção Erétil , Apneia Obstrutiva do Sono , Masculino , Humanos , Disfunção Erétil/etiologia , Pressão Positiva Contínua nas Vias Aéreas/efeitos adversos , Qualidade de Vida/psicologia , Polissonografia/efeitos adversos , Apneia Obstrutiva do Sono/complicações , Apneia Obstrutiva do Sono/terapia , Apneia Obstrutiva do Sono/diagnóstico
3.
Paediatr Respir Rev ; 49: 2-4, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36702717

RESUMO

Positive end-expiratory pressure (PEEP) consists of the delivery of a constant positive pressure in the airways by means of a noninvasive interface aiming to maintain airway patency throughout the entire respiratory cycle. PEEP is increasingly used in the chronic care of children with anatomical or functional abnormalities of the upper airways to correct severe persistent obstructive sleep apnea despite optimal management which commonly includes adenotonsillectomy in young children. PEEP may be used at any age, due to improvements in equipment and interfaces. Criteria for CPAP/NIV initiation, optimal setting, follow-up and monitoring, as well as weaning criteria have been established by international experts, but validated criteria are lacking. As chronic PEEP is a highly specialised treatment, patients should be managed by an expert pediatric multidisciplinary team.


Assuntos
Apneia Obstrutiva do Sono , Tonsilectomia , Criança , Humanos , Pré-Escolar , Respiração com Pressão Positiva , Apneia Obstrutiva do Sono/terapia , Adenoidectomia , Pressão Positiva Contínua nas Vias Aéreas
4.
Int J Geriatr Psychiatry ; 39(1): e6055, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38213266

RESUMO

OBJECTIVES: Obstructive sleep apnea (OSA) is linked to cognitive impairment. We aimed to investigate subjective cognitive complaints (SCCs) and objective cognitive scores and their relation to polysomnography (PSG) parameters in patients suspected of having OSA. METHODS: A prospective cohort cross-sectional study was conducted at Siriraj Hospital. Patients suspected of OSA who were scheduled for PSG were recruited. Cognition was assessed using the Montreal Cognitive Assessment (MoCA) and Color Trails Test (CTT). The Memory Index Score (MIS) was calculated from the MoCA. Subjective cognitive complaint presence was assessed through direct questioning of patients and by employing the Cognitive Change Index rated by self or informants (CCI-I). Patients with severe dementia were excluded. RESULTS: Among 258 patients (mean age 61.46 ± 7.05 years, 51.2% female), the mean MoCA score was 23.89 ± 3.89. Based on PSG results, patients were categorized into groups as follows: those without OSA or with mild OSA (combined total of 20.1%), moderate OSA (28.3%), or severe OSA (51.6%). Cognitive Change Index rated by self and CCI-I scores correlated significantly (r = 0.238, p = 0.019) but not with the MoCA score or CTT time. Objective cognitive scores were associated with PSG parameters: total sleep time (TST), sleep onset latency, wake after sleep onset, sleep stages, mean O2 saturation, and time spent with SaO2 below 90% (all p < 0.05). Subjective cognitive scores were not associated with PSG parameters, except CCI-I with TST. Participants with objective cognitive impairment had lower education, higher body mass index, more comorbidities, and lower SCC percentage (all p < 0.05). Patients with moderate to severe OSA had a higher proportion of objective cognitive impairment (64.1%) but a lower incidence of SCC (38.3%) than patients with no OSA or mild OSA. Thirty patients with severe OSA and cognitive impairment received continuous positive airway pressure (CPAP) treatment for a mean of 12.2 months. These patients showed MoCA and MIS improvement, but no significant changes were observed in their CTT and Cognitive Change Index scores. CONCLUSIONS: Most patients with OSA had objective cognitive impairment, but SCC was less frequent in patients with more severe OSA. Several PSG parameters correlated with cognitive scores but not with subjective cognitive scores. Patients with severe OSA may benefit cognitively from CPAP treatment.


Assuntos
Disfunção Cognitiva , Apneia Obstrutiva do Sono , Humanos , Feminino , Idoso , Masculino , Polissonografia , Estudos Prospectivos , Estudos Transversais , Disfunção Cognitiva/complicações , Apneia Obstrutiva do Sono/diagnóstico , Apneia Obstrutiva do Sono/complicações , Cognição
5.
Eur J Pediatr ; 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38829378

RESUMO

Surfactant replacement for respiratory distress syndrome (RDS) is currently guided by oxygen (FiO2) requirement in preterm neonates. Lung ultrasound (LUS) has emerged as an important predictive tool; however, there is a paucity of evidence from developing countries. The objective of this study was to determine the diagnostic accuracy of the LUS score in comparison to standard criteria based on FiO2 requirement for prediction of surfactant requirement. In this prospective study, preterm neonates of < 34 weeks' gestation with RDS were included within 2 h of life. Surfactant was administered if the FiO2 requirement exceeded 30%. Baseline characteristics, respiratory parameters, and LUS clips were recorded soon after birth and compared between the surfactant and non-surfactant groups. LUS scoring was later performed by masked assessors which was not used in the management of neonates. Among 82 neonates (mean gestation 30.6 weeks and weight 1375 g) included in the study, 33 (40.2%) received surfactant. The surfactant group had a higher Silverman score, required higher FiO2 and mean airway pressure, and needed invasive ventilation more frequently. The mean (± SD) LUS score was significantly higher in the surfactant (9.4 ± 3.2) compared to the non-surfactant group (5.1 ± 2.1). The diagnostic accuracy of LUS scoring was determined by ROC curve analysis (AUC (95% CI): 0.83 (0.74-0.92), p < 0.01). A cutoff score of ≥ 8 for LUS was considered optimal for the prediction of surfactant requirement (sensitivity and specificity (95% CI) of 70% (51-84) and 80% (66-90), respectively).    Conclusion: Lung ultrasound is a valid diagnostic tool for the prediction of surfactant requirements in resource-limited settings. What is Known: • Lung ultrasound has a good diagnostic accuracy in predicting the need for surfactant administration in preterm neonates in developed countries, but its role in developing countries is unclear. What is New: • Lung ultrasound proved to be a valid diagnostic tool in predicting surfactant replacement therapy in resource-limited settings. • The diagnostic performance of lung ultrasound was better in neonates on non-invasive ventilation, compared to invasive ventilation.

6.
Am J Respir Crit Care Med ; 207(6): 757-767, 2023 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-36342964

RESUMO

Rationale: Obstructive sleep apnea (OSA) is associated with impaired glycemic control and a higher risk of vascular complications, such as diabetic kidney disease (DKD). However, the effect of apnea-hypopnea suppression on DKD progression is unclear. Objectives: To assess the effect of continuous positive airway pressure (CPAP) on the urinary albumin-to-creatinine ratio (UACR) in patients with DKD and OSA. Methods: In a 52-week, multicentric, open-label, parallel, and randomized clinical trial, 185 patients with OSA and DKD were randomized to CPAP and usual care (n = 93) or usual care alone (n = 92). Measurements and Main Results: UACR, estimated glomerular filtration rate, serum concentrations of creatinine and glycated hemoglobin, insulin resistance, lipid concentrations, sleepiness, and quality of life. A 52-week change in UACR from baseline did not differ significantly between the CPAP group and the usual-care group. However, in per-protocol analyses that included 125 participants who met prespecified criteria for adherence, CPAP treatment was associated with a great reduction in UACR (mean difference, -10.56% [95% confidence interval, -19.06 to -2.06]; P = 0.015). CPAP effect on UACR was higher in nonsleepy patients with more severe OSA, worse renal function, and a more recent diagnosis of DKD. CPAP treatment also improved glycemic control and insulin resistance, as well as sleepiness and health-related quality of life. Conclusions: In patients with OSA and DKD, the prescription of CPAP did not result in a statistically significant reduction in albuminuria. However, good adherence to CPAP treatment in addition to usual care may result in long-term albuminuria reduction compared with usual care alone. Clinical trial registered with www.clinicaltrials.gov (NCT02816762).


Assuntos
Albuminúria , Nefropatias Diabéticas , Resistência à Insulina , Apneia Obstrutiva do Sono , Humanos , Albuminúria/etiologia , Pressão Positiva Contínua nas Vias Aéreas/métodos , Creatinina , Diabetes Mellitus , Nefropatias Diabéticas/complicações , Nefropatias Diabéticas/terapia , Qualidade de Vida , Apneia Obstrutiva do Sono/complicações , Apneia Obstrutiva do Sono/terapia , Sonolência
7.
Sleep Breath ; 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38642201

RESUMO

INTRODUCTION: Obstructive sleep apnea (OSA) is a chronic disease with a high populational prevalence that is characterized as airway closure during sleep. Treatment is multidisciplinary and varies according to each case. Continuous positive airway pressure (CPAP), oral appliances, and surgery are the primary therapeutic options. Non-invasive conservative treatments such as sleep hygiene, positional therapy, physical exercises, and weight loss aim to reduce the worsening of the disease while being complementary to the invasive primary treatment. OBJECTIVE: To analyze the impact of non-invasive conservative therapies on the clinical manifestations of OSA syndrome (OSA), compared with other interventions. METHOD: This was a systematic review with meta-analysis. The searches were performed without filters for the time period, type of publication, or language. Randomized clinical trials on subjects over 18 years of age diagnosed with untreated OSA were included. Responses to non-invasive conservative treatment were compared with responses to the primary intervention. Primary outcomes were assessed using the Epworth Sleepiness Scale and/or Functional Outcomes of Sleep Questionnaire (FOSQ). RESULTS: A total of eight studies were included in the review. The heterogeneity of the effect was estimated at 89.77%. Six studies compared conservative treatment with CPAP, one with oral appliances, and one with oropharyngeal exercises. Using the Epworth Sleepiness Scale measurements, the standardized difference in the estimated means, based on the random-effects model, was 0.457 (95% CI (1.082 to 0.169)) and the mean result did not differ significantly from zero (z = 1.43; p = 0.153). The conservative therapies assessed in this study improved the subjective quality of sleep, although the post-treatment ESE scores did not show significant results. The reduction in AHI and better outcomes in the evaluated domains, as well as in cognition and mood, were superior in the groups that received CPAP and IOD. CONCLUSION: The most commonly used treatments of choice for OSA are invasive, including the use of CPAP, oral appliances, and surgeries, being the most utilized options. This study demonstrated that non-invasive conservative treatments, such as sleep hygiene, yield results as effective as invasive treatments. Further studies are needed to confirm this result and to predict whether invasive treatment can be used as the primary treatment or only as a supplement.

8.
Sleep Breath ; 28(3): 1165-1172, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38225442

RESUMO

PURPOSE: Sleep apnoea (SA) is associated with accelerated cognitive decline in patients with mild cognitive impairment (MCI). Treatment of SA by continuous positive airway pressure (CPAP) may slow this decline if patients comply with the treatment. The aim of this study was to assess the rate of CPAP compliance in this population. METHODS: In this single-centre retrospective study conducted in a tertiary care institution, patients with a diagnosis of MCI and SA initiating CPAP between January 2015 and August 2021 were included. Data from the initial sleep recording, the 3-month follow-up and compliance with at least 12 months of CPAP were analysed. Compliance was defined as an average CPAP use of at least 4 h per night. RESULTS: 55 patients were included (49% women, age 70.7 ± 8.9 years, body mass index 28.9 ± 6.5 kg/m2). Aetiology of MCI was vascular (45.5%), psychiatric (12.7%) and related to Alzheimer's disease (7.3%), with 47.3% of amnesic disorders and 45.5% of dysexecutive disorders. The MiniMentalState score was 26.7 ± 3.1. SA was mostly obstructive (81.8%) with a mean apnoea-hypopnoea index of 41.1 ± 16.4/h. At 3 months, 38 patients were compliant (69%) with a CPAP median use of 5.9 h per night and 83% of nights. Self-reported tolerance was better in compliant patients (75.7% vs 38.5% p = 0.017). Thirty-four patients remained compliant at 12 months (62%). CONCLUSION: Our results suggest a high rate of CPAP compliance in patients suffering from MCI. Compliance was related to the device tolerance, emphasizing the need to closely monitor and improve this factor.


Assuntos
Disfunção Cognitiva , Pressão Positiva Contínua nas Vias Aéreas , Cooperação do Paciente , Humanos , Disfunção Cognitiva/terapia , Feminino , Masculino , Idoso , Estudos Retrospectivos , Pessoa de Meia-Idade , Apneia Obstrutiva do Sono/terapia , Síndromes da Apneia do Sono/terapia
9.
Sleep Breath ; 2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38683249

RESUMO

INTRODUCTION: Intermittent hypoxemia has an important role in the physiopathogenesis of obstructive sleep apnea (OSA) complications. Increased apoptosis due to intermittent hypoxemia may be an important clinical entity in OSA. In this study, we aimed to evaluate caspase-3 enzyme level, which is an indirect marker of increased apoptosis in patients with OSA and to evaluate the effect of OSA treatment with continuous positive airway pressure on caspase-3 enzyme level. MATERIALS AND METHODS: This study included 141 consecutive patients admitted to the sleep-disordered breathing laboratory within 6 months. Caspase-3 was measured in routine blood samples obtained on the morning of polysomnography (PSG) performed at night. The compliance of the patients to CPAP treatment was evaluated and caspase-3 levels were checked again after treatment. RESULTS: A total of 141 patients, 39 females (27,7%) and 102 males (72,3%) were included in the study. The mean age of the patients was 49 ± 12 years (min-17, max-77). According to PSG results, OSA was detected in 95.7% (135/141) of the cases. Mild OSA was 35 (24.8%), moderate OSA 39 (27.7%) and severe OSA 61 (43.3%) cases. Median caspase-3 enzyme levels were similar in men and women in the study group. There was no statistically significant difference in hemogram parameters and caspase-3 enzyme levels between the groups divided according to the presence and severity of OSA. It was determined that caspase-3 enzyme level did not change significantly after 3 months of CPAP treatment in OSA compared to pretreatment. Caspase-3 was found to have a negative correlation with both the percentage of daily use of CPAP therapy and the percentage of CPAP device use for more than 1 h per night. It was found that the control caspase-3 level decreased statistically significantly as the percentage of daily use of CPAP therapy increased (r = -0.397, p = 0.030). It was found that the control caspase-3 level decreased statistically significantly as the percentage of CPAP therapy use for more than 1 h per night increased (r = -0.411, p = 0.024). CONCLUSION: The results of this study did not reveal a relationship between the severity of OSA and caspase-3 levels. However, blood caspase-3 levels decreased as treatment compliance increased, suggesting that CPAP treatment may correct increased apoptosis in OSA. There is a need for more comprehensive studies on this issue.

10.
Sleep Breath ; 28(3): 1245-1250, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38308750

RESUMO

PURPOSE: To investigate the prevalence of treatment-emergent central sleep apnea (TECSA) in individuals with obstructive sleep apnea syndrome (OSAS) during continuous positive airway pressure (CPAP) titration and assess their polysomnographic characteristics. METHODS: A total of 116 patients with OSAS who underwent full-night CPAP titration at the Sleep Laboratory of Adana City Research and Education Hospital from September 2017 to January 2018 were recruited for the study. The patients' polysomnographic data related to respiratory events and sleep stages were reviewed in a retrospective manner. RESULTS: While on CPAP titration, 20 of the 116 patients developed central sleep apnea (CSA). The prevalence of TECSA in the patients with OSAS was 17.2%, being separately determined as 16.3% and 2.2% for the male and female patients, respectively. In the baseline PSG, the groups did not statistically significantly differ in relation to the apnea hypopnea index (AHI), central apnea index (CAI), arousal index (AI), or oxygen desaturation index (ODI). However, the TECSA group had a significantly higher mean oxygen saturation value compared to the non-TECSA group (p = 0.01). The total AHI, CAI, and AI values of the TECSA group were significantly higher during the whole CPAP titration compared to the non-TECSA group. No significant difference was observed in the comparison of the two groups in relation to the titration pressure and ODI. CONCLUSION: TECSA is a phenomenon that can occur with obstructive sleep apnea treatment and mostly regress spontaneously following appropriate CPAP treatment. TECSA is observed at different rates of prevalence. In this study, the prevalence of TECSA was higher than previously reported.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Polissonografia , Apneia do Sono Tipo Central , Apneia Obstrutiva do Sono , Humanos , Masculino , Feminino , Apneia Obstrutiva do Sono/terapia , Apneia Obstrutiva do Sono/epidemiologia , Apneia Obstrutiva do Sono/diagnóstico , Pessoa de Meia-Idade , Apneia do Sono Tipo Central/epidemiologia , Apneia do Sono Tipo Central/terapia , Apneia do Sono Tipo Central/diagnóstico , Adulto , Estudos Retrospectivos , Prevalência , Idoso
11.
Sleep Breath ; 28(3): 1231-1243, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38308751

RESUMO

BACKGROUND: Obstructive sleep apnea (OSA) can be considered a chronic inflammatory disease that impacts all bodily systems, including the immune system. This study aims to assess the Th17/Treg pattern in patients with OSA and the effect of continuous positive airway pressure (CPAP) treatment. METHODS: OSA patients and healthy controls were recruited. OSA patients recommended for CPAP treatment were followed up for three months. Flow cytometry was employed to determine the proportion of Th17 and Treg cells. Real-time quantitative polymerase chain reaction (PCR) and western blotting were utilized to detect the mRNA and protein levels of receptor-related orphan receptor γt (RORγt) and forkhead/winged helix transcription factor (Foxp3), respectively, in peripheral blood mononuclear cells (PBMCs). Enzyme-linked immunosorbent assay (ELISA) was performed to measure the serum levels of interleukin-17 (IL-17), IL-6, transforming growth factor-ß1 (TGF-ß1), and hypoxia-induced factor-1α (HIF-1α). RESULTS: A total of 56 OSA patients and 40 healthy controls were recruited. The proportion of Th17 cells, Th17/Treg ratio, mRNA and protein levels of RORγt, and serum IL-17, IL-6, and HIF-1α levels were higher in OSA patients. Conversely, the proportion of Treg cells, mRNA and protein levels of Foxp3, and serum TGF-ß1 levels were decreased in OSA patients. The proportion of Th17 and Treg cells in OSA can be predicted by the apnea hypopnea index (AHI), IL-6, TGF-ß1 and, HIF-1α. 30 moderate-to-severe OSA patients were adherent to three-month CPAP treatment, with improved Th17/Treg imbalance, IL-17, IL-6, TGF-ß1, and HIF-1α levels compared to pre-treatment values. CONCLUSION: There was a Th17/Treg imbalance in OSA patients. The prediction of Th17 and Treg cell proportions in OSA can be facilitated by AHI, as well as serum IL-6, TGF-ß1, and HIF-1α levels. Furthermore, CPAP treatment can potentially improve the Th17/Treg imbalance and reduce proinflammatory cytokines in OSA patients.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Membro 3 do Grupo F da Subfamília 1 de Receptores Nucleares , Apneia Obstrutiva do Sono , Linfócitos T Reguladores , Células Th17 , Humanos , Apneia Obstrutiva do Sono/terapia , Apneia Obstrutiva do Sono/imunologia , Apneia Obstrutiva do Sono/sangue , Células Th17/imunologia , Masculino , Linfócitos T Reguladores/imunologia , Feminino , Pessoa de Meia-Idade , Adulto , Membro 3 do Grupo F da Subfamília 1 de Receptores Nucleares/genética , Membro 3 do Grupo F da Subfamília 1 de Receptores Nucleares/sangue , Interleucina-17/sangue , Subunidade alfa do Fator 1 Induzível por Hipóxia/sangue , Subunidade alfa do Fator 1 Induzível por Hipóxia/genética , Fatores de Transcrição Forkhead/sangue , Fatores de Transcrição Forkhead/genética , Fator de Crescimento Transformador beta1/sangue , Fator de Crescimento Transformador beta1/genética , Interleucina-6/sangue
12.
Eur Arch Otorhinolaryngol ; 281(6): 3131-3141, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38206392

RESUMO

PURPOSE: This study aimed to obtain a comprehensive view of the risk of developing cancer in patients with obstructive sleep apnea (OSA) and to compare this risk between patients receiving continuous positive airway pressure (CPAP) therapy versus upper airway surgery (UAS). METHODS: We used both local data and a global-scale federated data research network, TriNetX, to access electronic medical records, including those of patients diagnosed with OSA from health-care organizations (HCOs) worldwide. We used propensity score matching and the score-matched analyses of data for 5 years of follow-up, RESULTS: We found that patients who had undergone UAS had a similar risk of developing cancer than those who used CPAP [hazard ratio of 0.767 (95% CI 0.559-1.053; P = 0.100)]. CONCLUSION: Analysis of the large data sets collected from HCOs in Europe and globally lead us to conclude that in patients with OSA, neither CPAP nor UAS were associated with the development of cancer better than in non-treated patients.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Neoplasias , Apneia Obstrutiva do Sono , Humanos , Masculino , Apneia Obstrutiva do Sono/terapia , Apneia Obstrutiva do Sono/epidemiologia , Apneia Obstrutiva do Sono/complicações , Feminino , Pessoa de Meia-Idade , Seguimentos , Neoplasias/complicações , Neoplasias/cirurgia , Pontuação de Propensão , Adulto , Fatores de Risco , Idoso
13.
Eur Arch Otorhinolaryngol ; 281(7): 3797-3804, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38578504

RESUMO

PURPOSE: Drug-induced sleep endoscopy (DISE) is commonly performed in patients suffering obstructive sleep apnea (OSA) with continuous positive airway pressure (CPAP) intolerance. We aimed to evaluate the effects of adding CPAP to DISE to provide understanding of the reason of its failure and better guidance in future therapeutic decisions. METHODS: A retrospective observational descriptive study was conducted on CPAP-intolerant patients with moderate-severe OSA. DISE was used to evaluate upper airway collapsibility, and CPAP was tested to better describe anatomical sites of obstruction and to measure the opening pharyngeal pressure. RESULTS: Sample size consisted of 38 patients with a mean age of 49 ± 9 years. Mean BMI was 28.4 ± 2.4 kg/m2, mean apnea-hypopnea index (AHI) was 35.4 events per hour ± 20.1, and mean saturation under 90% (TSat90) was 14.5%. In DISE we found a collapse at Velum in 92% of patients, at Oropharyngeal level in 89%, at tongue in 42%, and at epiglottis in 36%. In the subgroup of patients with clinical failure with CPAP, we observed 100% of epiglottic collapse and 50% of tongue obstruction. In this specific population, we recommended personalized surgery and myofunctional therapy. CONCLUSION: DISE-CPAP is a useful tool to select the treatment that better fits to each patient taking care all information available. It improves our ability to prescribe a multilevel treatment with an exhaustive topographic evaluation of upper airway collapsibility that complements CPAP classic titration, and it can be helpful to distinguish better candidates for surgery, myofunctional therapy or CPAP.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Endoscopia , Apneia Obstrutiva do Sono , Humanos , Pressão Positiva Contínua nas Vias Aéreas/métodos , Apneia Obstrutiva do Sono/terapia , Apneia Obstrutiva do Sono/fisiopatologia , Pessoa de Meia-Idade , Estudos Retrospectivos , Masculino , Feminino , Endoscopia/métodos , Adulto , Obstrução das Vias Respiratórias/terapia , Obstrução das Vias Respiratórias/fisiopatologia , Polissonografia
14.
Int J Mol Sci ; 25(10)2024 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-38791288

RESUMO

Sleep-disordered breathing (SDB), including obstructive and central sleep apnea, significantly exacerbates heart failure (HF) through adverse cardiovascular mechanisms. This review aims to synthesize existing literature to clarify the relationship between SDB and HF, focusing on the pathophysiological mechanisms, diagnostic challenges, and the effectiveness of treatment modalities like continuous positive airway pressure (CPAP) and adaptive servo-ventilation ASV. We analyzed peer-reviewed articles from 2003 to 2024 sourced from PubMed, EMBASE, Scopus, and Web of Science databases. The prevalence of SDB in HF patients is high, often underdiagnosed, and underappreciated. Management strategies, including CPAP and ASV, have been shown to mitigate symptoms and improve cardiac function. However, despite the availability of effective treatments, significant challenges in screening and diagnosis persist, affecting patient management and outcomes. DB significantly impacts HF prognosis. Enhanced screening strategies and broader utilization of therapeutic interventions like CPAP and ASV are essential to improve the management and outcomes of HF patients with concomitant SDB. Future research should focus on refining diagnostic and treatment protocols to optimize care for HF patients with SDB.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Insuficiência Cardíaca , Síndromes da Apneia do Sono , Humanos , Insuficiência Cardíaca/terapia , Síndromes da Apneia do Sono/terapia , Síndromes da Apneia do Sono/complicações , Síndromes da Apneia do Sono/diagnóstico , Prognóstico
15.
Arch Orthop Trauma Surg ; 144(6): 2775-2781, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38758237

RESUMO

INTRODUCTION: Patients with sleep apnea, affecting up to 1 in 4 older men in the United States, may be at increased risk of postoperative complications after total knee arthroplasty (TKA), including increased thromboembolic and cerebrovascular events, as well as respiratory, cardiac, and digestive complications. However, the extent to which the use of CPAP in patients with sleep apnea has been studied in TKA is limited. METHODS: A national, all-payer database was queried to identify all patients who underwent a primary TKA between 2010 and 2021. Patients who had any history of sleep apnea were identified and then stratified based on the use of CPAP. A propensity score match analysis was conducted to limit the influence of confounders. Medical complications, such as cardiac arrest, stroke, pulmonary embolism, transfusion, venous thromboembolism, and wound complications, were collected at 90-days, 1-year, and 2-years. RESULTS: The bivariate analysis showed inferior outcomes for sleep apnea with CPAP use compared to sleep apnea with no CPAP use, in terms of length of stay (5.9 vs. 5.2, p < 0.001), PJI (1.31% vs. 1.14%, p < 0.001), stroke (0.97% vs. 0.82%, p < 0.001), VTE (1.04% vs. 0.82, p < 0.001), and all other complications at 90-days (p < 0.001) except cardiac arrest (0.14% vs. 0.11%, p = 0.052), and aseptic revision (0.40% vs. 0.39%, p = 0.832), PJI (1.81% vs. 1.55%, p < 0.001) and aseptic revision (1.25% vs. 1.06%, p < 0.001) at 1-year, and PJI (2.07 vs. 1.77, p < 0.001) and aseptic revision (1.98 vs. 1.17, p < 0.001) at 2-years. CONCLUSION: Patients with sleep apnea have increased postoperative complications after undergoing TKA in comparison to patients without sleep apnea. More severe sleep apnea, represented by CPAP usage in this study led to worse postoperative outcomes but further analysis is required signify the role of CPAP in this patient population. Patients with sleep apnea should be treated as a high-risk group.


Assuntos
Artroplastia do Joelho , Pressão Positiva Contínua nas Vias Aéreas , Complicações Pós-Operatórias , Pontuação de Propensão , Apneia Obstrutiva do Sono , Humanos , Artroplastia do Joelho/efeitos adversos , Masculino , Apneia Obstrutiva do Sono/terapia , Idoso , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Feminino , Pessoa de Meia-Idade , Cuidados Pré-Operatórios/métodos , Estudos Retrospectivos
16.
Neonatal Netw ; 43(3): 165-175, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38816221

RESUMO

In a sixty-eight-bed level-IV NICU, an increased incidence of hospital-acquired pressure injuries (HAPIs) from noninvasive ventilation (NIV) devices was identified. The aim of this quality improvement project was to decrease HAPIs from NIV by 10%. A literature review and the Plan-Do-Study-Act were implemented. The intervention included a customized silicone foam dressing under NIV, an NIV skincare bundle, and multidisciplinary support. Hospital-acquired pressure injury rates were tracked over 3 years postinterventions. The incidence of HAPIs declined by 20% from 0.2 per 1,000 patient days to 0.05 per 1,000 patient days. Relative risk was 4.6 times greater prior to intervention (p = .04). Continuous positive airway pressure (CPAP) failure was not noted and measured by the percentage of patients on ventilators pre- and postintervention. Customized silicone foam dressings under NIV, NIV skincare bundle, and multidisciplinary team support may decrease HAPIs in neonates without CPAP failure.


Assuntos
Bandagens , Ventilação não Invasiva , Úlcera por Pressão , Humanos , Recém-Nascido , Úlcera por Pressão/prevenção & controle , Ventilação não Invasiva/métodos , Ventilação não Invasiva/enfermagem , Ventilação não Invasiva/instrumentação , Feminino , Melhoria de Qualidade , Unidades de Terapia Intensiva Neonatal , Masculino , Silicones , Pacotes de Assistência ao Paciente/métodos , Higiene da Pele/métodos , Higiene da Pele/enfermagem , Doença Iatrogênica/prevenção & controle
17.
Nurs Crit Care ; 29(1): 49-57, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37487593

RESUMO

BACKGROUND: During the pandemic outbreak, helmet continuous positive airway pressure (CPAP) was widely used as respiratory support for COVID-19 patients, inside and outside of intensive care units. The available literature suggests specific interventions to improve the comfort of patients treated with helmet-CPAP. Few reports are available on the experiences of patients undergoing this treatment. AIM: This qualitative study aimed to explore the views and recollections of COVID-19 patients undergoing helmet-CPAP. STUDY DESIGN: We conducted semi-structured interviews with thematic analysis. Participants were recruited from the follow-up programme for COVID-19 patients discharged from an Italian general intensive care unit. Participants were interviewed by telephone. Data analysis followed the principles of thematic synthesis approach. FINDINGS: We conducted 29 phone calls in patients eligible for the study. Five participants declared that they did not remember the time spent in hospital on helmet-CPAP. Twenty-four patients were then included. Two themes and six subthemes were generated from their interview data: (1) The helmet-CPAP as a life-saving treatment (subthemes: recognition of the usefulness of treatment and resilience); (2) the negative feelings related to helmet-CPAP application (subthemes: communication problems, entrapment, mental confusion, fear of dying). Each patient's experience was unique, but some discomfort elements such as noise, gas flow turbulence, choking sensation and thirst were found to be very common. CONCLUSIONS: The application of helmet-CPAP treatment generated positive and negative memories and feelings in COVID-19 patients during the pandemic. The patients' experience has provided an overview of the main factors of discomfort. This can be a starting point for taking corrective measures to promote greater helmet tolerance and subsequent treatment success. RELEVANCE TO CLINICAL PRACTICE: This study has provided an insight into the patient's recollections about helmet-CPAP treatment during a worldwide pandemic. The findings suggested strict applications of interventions aimed to reduce some issues that participants reported, to improve their compliance to treatment. Results from this study could help nurses in understanding the needs of patients treated with helmet-CPAP and may foster a care focused on patient-centred outcomes.


Assuntos
COVID-19 , Insuficiência Respiratória , Humanos , Insuficiência Respiratória/terapia , Pandemias , Pressão Positiva Contínua nas Vias Aéreas , Dispositivos de Proteção da Cabeça , COVID-19/terapia
18.
Nurs Crit Care ; 29(2): 357-365, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-37537508

RESUMO

BACKGROUND: Agitation and incompliance with the treatment may be observed in patients undergoing continuous positive airway pressure (CPAP), which may cause inadequate oxygenation, sedation, termination of CPAP or intubation of the patient. AIM: This study was conducted to determine the effect of listening to music during CPAP on the agitation levels of intensive care patients who underwent CPAP as a result of COVID-19 and their compliance with the treatment. STUDY DESIGN: This study was a prospective, randomized, controlled clinical trial. Seventy-six intensive care patients with COVID-19 were included in this study and assigned to the music and control groups via the block randomization method. The study was completed with 70 patients. The patients and outcome assessors were not blinded in this study. The Richmond Agitation and Sedation Scale (RASS) level, respiratory rate, oxygen saturation (SpO2 ) and mask air leakage amount were the outcome measures. RESULTS: The mean RASS score of the patients in the intervention group was 2.14 ± 0.69 before CPAP, 1.63 ± 064 at the 1st minute, 0.89 ± 0.58 at the 15th minute and 0.74 ± 0.61 at the 30th minute. The mean RASS score of the patients in the control group was 2.06 ± 0.53 before CPAP, 1.80 ± 0.58 at the 1st minute, 1.43 ± 0.60 at the 15th minute and 1.46 ± 0.61 at the 30th minute of CPAP. There was a statistically significant difference between the groups at the 15th and 30th minutes (t = -3.81, p < .001; t = -4.89, p < .001 respectively). The mean respiratory rate, SpO2 and mask air leakage amount were compared between the groups. There was a statistically significant difference in favour of the intervention group at the 15th minute (t = -2.47, p < .001; t = 2.57, p < .001; t = 2.93, p < .001 respectively) and 30th minute (t = -3.17, p < .001; t = 3.46, p < .001; t = -3.93, p < .001 respectively). CONCLUSIONS: The study results show that listening to music during CPAP reduces the agitation levels of patients and helps them comply with the treatment. RELEVANCE TO CLINICAL PRACTICE: Music may be a beneficial application for patients who are agitated and unable to comply with CPAP therapy. This is an easy and applicable method, which can protect patients from the adverse effects of failed CPAP.


Assuntos
COVID-19 , Música , Humanos , COVID-19/terapia , Pressão Positiva Contínua nas Vias Aéreas , Estudos Prospectivos , Cuidados Críticos/métodos
19.
Medicina (Kaunas) ; 60(4)2024 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-38674228

RESUMO

Background and Objectives: The COVID-19 disease has significantly burdened the healthcare system, including all units of severe patient treatment. Non-intensive care units were established to rationalize the capacity within the Intensive Care Unit (ICU) and to create a unit where patients with Acute Respiratory Distress Syndrome (ARDS) could be treated with non-invasive Continuous Positive Air Pressure (CPAP) outside the ICU. This unicentric retrospective study aimed to assess the efficacy of NIV Treatment in Patients of the fourth pandemic wave and how its application affects the frequency and mortality of ICU-treated patients at University Hospital Rijeka compared to earlier waves of the COVID-19 pandemic. Furthermore, the study showcases the effect of the Patient/Nurse ratio (P/N ratio) on overall mortality in the ICU. Materials and Methods: The study was conducted on two groups of patients with respiratory insufficiency in the second and third pandemic waves, treated in the COVID Respiratory Centre (CRC) (153 patients). We also reviewed a cohort of patients from the fourth pandemic wave who were initially hospitalized in a COVID-6 non-intensive unit from 1 October 2021 to 1 November 2022 (102 patients), and some of them escalated to CRC. Results: The introduction of the CPAP non-invasive ventilation method as a means of hypoxic respiratory failure treatment in non-intensive care units has decreased the strain, overall number of admissions, and CRC patient mortality. The overall fourth wave mortality was 29.4%, compared to the 58.2% overall mortality of the second and third waves. Conclusions: As a result, this has decreased CRC patient admissions and, by itself, overall mortality.


Assuntos
COVID-19 , Pressão Positiva Contínua nas Vias Aéreas , Humanos , COVID-19/terapia , COVID-19/mortalidade , Pressão Positiva Contínua nas Vias Aéreas/métodos , Estudos Retrospectivos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Unidades de Terapia Intensiva/estatística & dados numéricos , SARS-CoV-2 , Resultado do Tratamento , Insuficiência Respiratória/terapia , Insuficiência Respiratória/mortalidade , Mortalidade Hospitalar , Pandemias , Síndrome do Desconforto Respiratório/terapia , Síndrome do Desconforto Respiratório/mortalidade
20.
EMBO J ; 38(2)2019 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-30530478

RESUMO

Centrosome amplification is a hallmark of human cancers that can trigger cancer cell invasion. To survive, cancer cells cluster amplified extra centrosomes and achieve pseudobipolar division. Here, we set out to prevent clustering of extra centrosomes. Tubulin, by interacting with the centrosomal protein CPAP, negatively regulates CPAP-dependent peri-centriolar material recruitment, and concurrently microtubule nucleation. Screening for compounds that perturb CPAP-tubulin interaction led to the identification of CCB02, which selectively binds at the CPAP binding site of tubulin. Genetic and chemical perturbation of CPAP-tubulin interaction activates extra centrosomes to nucleate enhanced numbers of microtubules prior to mitosis. This causes cells to undergo centrosome de-clustering, prolonged multipolar mitosis, and cell death. 3D-organotypic invasion assays reveal that CCB02 has broad anti-invasive activity in various cancer models, including tyrosine kinase inhibitor (TKI)-resistant EGFR-mutant non-small-cell lung cancers. Thus, we have identified a vulnerability of cancer cells to activation of extra centrosomes, which may serve as a global approach to target various tumors, including drug-resistant cancers exhibiting high incidence of centrosome amplification.


Assuntos
Centrossomo/metabolismo , Proteínas Associadas aos Microtúbulos/metabolismo , Neoplasias/tratamento farmacológico , Bibliotecas de Moléculas Pequenas/administração & dosagem , Tubulina (Proteína)/metabolismo , Animais , Linhagem Celular Tumoral , Proliferação de Células/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Centrossomo/efeitos dos fármacos , Ensaios de Seleção de Medicamentos Antitumorais , Feminino , Células HeLa , Humanos , Camundongos , Neoplasias/metabolismo , Ligação Proteica/efeitos dos fármacos , Bibliotecas de Moléculas Pequenas/farmacologia , Ensaios Antitumorais Modelo de Xenoenxerto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA