Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 269
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Antimicrob Agents Chemother ; 68(7): e0038124, 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38864612

RESUMO

Candida auris is an evolving and concerning global threat. Of particular concern are bloodstream infections related to central venous catheters. We evaluated the activity of taurolidine, a broad-spectrum antimicrobial in catheter lock solutions, against 106 C. auris isolates. Taurolidine was highly active with a MIC50/MIC90 of 512/512 mg/L, over 20-fold lower than lock solution concentrations of ≥13,500 mg/L. Our data demonstrate a theoretical basis for taurolidine-based lock solutions for prevention of C. auris catheter-associated infections.


Assuntos
Antifúngicos , Candida auris , Infecções Relacionadas a Cateter , Testes de Sensibilidade Microbiana , Taurina , Tiadiazinas , Tiadiazinas/farmacologia , Taurina/análogos & derivados , Taurina/farmacologia , Infecções Relacionadas a Cateter/microbiologia , Infecções Relacionadas a Cateter/tratamento farmacológico , Infecções Relacionadas a Cateter/prevenção & controle , Humanos , Antifúngicos/farmacologia , Candida auris/efeitos dos fármacos , Cateteres Venosos Centrais/microbiologia , Cateteres Venosos Centrais/efeitos adversos , Candidíase/microbiologia , Candidíase/tratamento farmacológico , Candidemia/microbiologia , Candidemia/tratamento farmacológico
2.
J Infect Chemother ; 30(9): 942-945, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38369124

RESUMO

The fungus Wickerhamiella pararugosa (Candida pararugosa) has been detected in various human organs but has rarely caused bloodstream infections. This report presents a case of central venous catheter-related bloodstream infection (CRBSI) of W. pararugosa in an adult. A female patient in her 80s was admitted to our facility for intestinal obstruction caused by colorectal cancer. The patient's ability to consume food was hindered, necessitating the insertion of a central venous catheter (CVC) into the internal jugular vein. On day 3 after admission, the patient developed a fever, prompting blood and CVC tip cultures to be performed. On day 5, yeast-like fungi were discovered in the blood cultures, and fosfluconazole (fluconazole [FLCZ] pro-drug) treatment was initiated. On day 8, yeast-like fungi were identified in both the blood and CVC tip cultures, leading to a diagnosis of CRBSI. The fungus was identified as W. pararugosa through biochemical and genetic characterization. This finding justified the use of micafungin (MCFG) for combination therapy. On day 17, the minimum inhibitory concentrations (MIC) for FLCZ and MCFG were 4-8 and 0.06 µg/mL, respectively. Accordingly, the treatment was changed to monotherapy with MCFG. After a 21-day treatment regimen, the patient was discharged on day 31. We present a case of CRBSI caused by W. pararugosa in an adult with intestinal obstruction. The notable increase in the MIC of FLCZ necessitated monotherapy with MCFG, which resulted in successful recovery of the patient.


Assuntos
Antifúngicos , Obstrução Intestinal , Humanos , Feminino , Obstrução Intestinal/microbiologia , Obstrução Intestinal/etiologia , Antifúngicos/uso terapêutico , Idoso de 80 Anos ou mais , Infecções Relacionadas a Cateter/microbiologia , Infecções Relacionadas a Cateter/tratamento farmacológico , Infecções Relacionadas a Cateter/diagnóstico , Testes de Sensibilidade Microbiana , Fluconazol/uso terapêutico , Candida/isolamento & purificação , Candida/efeitos dos fármacos , Cateteres Venosos Centrais/efeitos adversos , Cateteres Venosos Centrais/microbiologia , Micafungina/uso terapêutico , Neoplasias Colorretais/complicações , Neoplasias Colorretais/microbiologia , Candidemia/tratamento farmacológico , Candidemia/diagnóstico , Candidemia/microbiologia , Candidemia/complicações
3.
J Infect Chemother ; 30(7): 664-667, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38184108

RESUMO

Catheter-related bloodstream infections (CRBSIs) caused by Lactobacillus spp. and Lacticaseibacillus spp. are rare, and their clinical course and optimal treatment remain uncertain. In this report, we present a 46-year-old male patient who experienced clinically diagnosed Lacticaseibacillus paracasei CRBSI on four separate occasions, despite receiving systemic administration of antibiotics and antimicrobial lock therapy. The patient did not develop L. paracasei bacteremia after catheter removal. This case report furthers our knowledge of CRBSI caused by Lactobacillus and related genera and highlights the need for further research.


Assuntos
Antibacterianos , Bacteriemia , Infecções Relacionadas a Cateter , Lacticaseibacillus paracasei , Humanos , Masculino , Pessoa de Meia-Idade , Infecções Relacionadas a Cateter/microbiologia , Infecções Relacionadas a Cateter/tratamento farmacológico , Infecções Relacionadas a Cateter/diagnóstico , Bacteriemia/microbiologia , Bacteriemia/tratamento farmacológico , Bacteriemia/diagnóstico , Antibacterianos/uso terapêutico , Lacticaseibacillus paracasei/isolamento & purificação
4.
BMC Nephrol ; 25(1): 331, 2024 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-39358687

RESUMO

BACKGROUND: Despite efforts to improve the management of catheter-related bloodstream infections (CRBSI) in literature, temporary CVCs continue to be used for maintenance hemodialysis outside of acute care settings, particularly in the Philippines. METHODS: We conducted a retrospective cohort study to investigate the incidence, outcomes, risk factors, and microbiological patterns of CRBSI among adult kidney disease patients undergoing hemodialysis at the Philippine General Hospital, the country's largest tertiary referral center. We included all adult patients who received a CVC for hemodialysis from January 1, 2018, to August 31, 2019, and followed them for six months to observe the occurrence of CRBSI and its outcomes. RESULTS: Our study documented a CRBSI incidence rate of 6.72 episodes per 1000 catheter days, with a relapse rate of 5.08%, a reinfection rate of 15.74%, and a mortality rate of 6.09%. On multivariable regression analysis, we identified autoimmune disease, dialysis frequency of > 3 × per week, use of CVC for either blood transfusion or IV medications, renal hypoperfusion, drug-induced nephropathy, and hypertensive kidney disease as significant risk factors for CRBSI. Gram-negative bacteria, including B. cepacia complex, Enterobacter, and Acinetobacter spp, were the most common organisms causing CRBSI. Multidrug-resistant organisms (MDROs) comprised almost half of the isolates (n = 89, 44.5%), with Coagulase-negative Staphylococcus species having the highest proportion among gram-positive organisms and Acinetobacter spp. among gram-negative isolates. CONCLUSION: Our findings emphasize the need for more stringent measures and interventions to prevent the propagation of identified pathogens, such as a review of sterile technique and adequate hygiene practices, continued surveillance, and expedited placement and utilization of long-term access for patients on maintenance hemodialysis. Furthermore, CVC use outside of hemodialysis should be discouraged, and common antibiotic regimens such as piperacillin-tazobactam and fluoroquinolones should be reviewed for their low sensitivity patterns among gram-negative isolates. Addressing these issues can improve hemodialysis patients' outcomes and reduce the CRBSI burden in our institution.


Assuntos
Infecções Relacionadas a Cateter , Diálise Renal , Humanos , Filipinas/epidemiologia , Diálise Renal/efeitos adversos , Infecções Relacionadas a Cateter/epidemiologia , Infecções Relacionadas a Cateter/microbiologia , Estudos Retrospectivos , Masculino , Feminino , Pessoa de Meia-Idade , Fatores de Risco , Incidência , Cateteres Venosos Centrais/efeitos adversos , Cateteres Venosos Centrais/microbiologia , Idoso , Bacteriemia/epidemiologia , Bacteriemia/etiologia , Adulto , Estudos de Coortes , Antibacterianos/uso terapêutico
5.
J Ultrasound Med ; 43(2): 323-333, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37916425

RESUMO

BACKGROUND: Catheter removal is essential for treating catheter-related bloodstream infection (CRBSI); however, clinicians are sometimes hesitant to remove catheters in pediatric patients due to the difficulty of securing vascular access. Confirming the diagnosis of CRBSI is important to justify catheter removal. The purpose of this study was to describe the sonographic findings of CRBSI. MATERIALS AND METHODS: We included patients with a central venous catheter (CVC) or peripherally inserted central catheter (PICC) who had a positive blood culture and underwent ultrasound. The patients were classified as with or without CRBSI. Sonographic findings, such as the presence/absence of thrombus, venous wall thickening, hyperechogenicity, and fluid collection around the vein were compared using Fisher's exact test. RESULTS: Of the 58 patients, 38 (66%) were diagnosed with CRBSI. The presence of thrombus (19/38 vs 3/20, P = .011); and hyperechogenicity around the vein (14/38 vs 2/20, P = .035) differed significantly, but There was no significant difference in the presence of venous wall thickening (10/38 vs 1/20, P = .077), and fluid collection around the vein (5/38 vs 0/20, P = .153), did not differ significantly in patients with and without CRBSI, respectively. One-third of patients with CRBSI, including 11 (42.3%) patients with CVC, and 2 (16.7%) patients with PICC, did not have abnormal sonographic findings. CONCLUSION: Ultrasound findings are useful for diagnosing CRBSI. However, the sensitivity of sonographic findings is low and abnormal sonographic findings are sometimes absent in children with CRBSI; therefore, physicians should not rule out CRBSI based on normal sonographic findings, especially in patients a CVC and a positive blood culture.


Assuntos
Bacteriemia , Infecções Relacionadas a Cateter , Cateterismo Venoso Central , Cateteres Venosos Centrais , Trombose , Humanos , Criança , Cateterismo Venoso Central/efeitos adversos , Bacteriemia/diagnóstico por imagem , Infecções Relacionadas a Cateter/diagnóstico por imagem , Cateteres Venosos Centrais/efeitos adversos
6.
Pediatr Surg Int ; 40(1): 226, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-39145817

RESUMO

PURPOSE: Patients with intestinal failure (IF) require long-term parenteral nutrition using central venous catheters (CVCs), which often require replacement. We adopted a less fallible guidewire replacement (GWR) method and verified its effectiveness and validity. METHODS: We enrolled 108 cases that underwent a CVC replacement with "GWR" method with IF at our department between 2013 and 2023. We retrospectively reviewed patients' clinical details with tunneled CVC (Hickman/Broviac catheter). For the analysis, we compared for the same time period the catheter exchange method "Primary placement"; newly inserted catheter by venipuncture. RESULTS: The success rate of catheter replacement using GWR was 94.4%. There were six unsuccessful cases. A log-rank test showed no significant difference in catheter survival between primary placement and the GWR, and the time to first infection was significantly longer in the GWR (p = 0.001). Furthermore, no significant differences were observed between the two methods until the first infection, when the exchange indication was limited to infections. In the same way, when the indication was restricted to catheter-related bloodstream infection, there was no significant difference in catheter survival between the two approaches. CONCLUSION: Our GWR procedure was easy to perform and stable, with a high success rate and almost no complications. Moreover, using a guidewire did not increase the frequency of catheter replacement and the infection rate.


Assuntos
Cateterismo Venoso Central , Cateteres Venosos Centrais , Insuficiência Intestinal , Humanos , Estudos Retrospectivos , Masculino , Feminino , Cateterismo Venoso Central/métodos , Insuficiência Intestinal/terapia , Lactente , Pré-Escolar , Criança , Infecções Relacionadas a Cateter , Nutrição Parenteral/métodos , Resultado do Tratamento , Remoção de Dispositivo/métodos , Adolescente
7.
Antimicrob Agents Chemother ; 67(1): e0126422, 2023 01 24.
Artigo em Inglês | MEDLINE | ID: mdl-36602372

RESUMO

Tunneled central venous catheter (TCVC) related infection remains a challenge in the care of hemodialysis patients. We aimed to determine the best antimicrobial lock therapy (ALT) to eradicate coagulase-negative staphylococci (CoNS) biofilms. We studied the colonization status of the catheter every 30 days by quantitative blood cultures (QBC) drawn through all catheter lumens. Those patients with a significant culture (i.e.,100 to 1,000 CFU/mL) of a CoNS were classified as patients with a high risk of developing catheter-related bloodstream infections (CRBSI). They were assigned to receive daptomycin, vancomycin, teicoplanin lock solution, or the standard of care (SoC) (i.e., heparin lock). The primary endpoint was to compare eradication ability (i.e., negative QBC for 30 days after ending ALT) rates between different locks and the SoC. A second objective was to analyze the correlation between ALT exposure and isolation of CoNS with antimicrobial resistance. Daptomycin lock was associated with a significant higher eradication success than with the SoC: 85% versus 30% (relative risk [RR] = 14, 95% confidence interval [CI] = 2.4 - 82.7); followed by teicoplanin locks with a 83.3% success (RR = 11.7; 95% CI = 2 - 70.2). We observed CoNs isolates with a higher teicoplanin MIC in patients with repeated teicoplanin locks exposure (coefficient = 0.3; 95% CI = 0.11 - 0.47). However, teicoplanin MICs decreased in patients treated with vancomycin locks (coefficient = -0.56; 95% CI = -0.85 - -0.02). Methicillin-resistance decreased with accumulative ALT (RR = 0.82; 95% CI = 0.69 - 0.98). In this study, daptomycin locks achieve the highest eradication rate of CoNS from hemodialysis catheters in vivo.


Assuntos
Anti-Infecciosos , Infecções Relacionadas a Cateter , Cateteres Venosos Centrais , Daptomicina , Humanos , Daptomicina/farmacologia , Daptomicina/uso terapêutico , Vancomicina/farmacologia , Vancomicina/uso terapêutico , Antibacterianos/farmacologia , Antibacterianos/uso terapêutico , Teicoplanina/farmacologia , Teicoplanina/uso terapêutico , Coagulase , Infecções Relacionadas a Cateter/tratamento farmacológico , Infecções Relacionadas a Cateter/prevenção & controle , Staphylococcus , Cateteres Venosos Centrais/efeitos adversos , Biofilmes
8.
Eur J Haematol ; 111(6): 914-921, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37705250

RESUMO

OBJECTIVES: Chlorhexidine gluconate (CHG)-coated gel pad dressings for central venous catheter (CVC) may prevent CVC-related bloodstream infections (CRBSI). However, real-world data showing beneficial effects in patients with hematologic malignancies are scarce. METHODS: In a matched-pair analysis with data from a multicenter CVC registry, non-tunneled jugular and subclavian vein CVC in adults with hematologic malignancies or germ cell tumors (including patients receiving autologous hematopoietic stem cell transplantation [ASCT]) with CHG were compared with non-CHG dressings. The primary endpoint was definite CRBSI rate within 14 days (dCRBSI14) of CVC insertion; secondary endpoints were combined rate of definite or probable CRBSI within 14 days (dpCRBSI14), overall (dpCRBSI), and CRBSI incidences of all estimates. RESULTS: In total, 2070 CVCs were assessed. There was no statistically significant difference in dCRBSI14 (2.3% vs. 3.5%) between patients with and without CHG gel dressings. Likewise, with regards to dpCRBSI14 (6.2% vs. 6.3%) and the overall dpCRBSI rate (9.2% vs. 10.5%), no significant difference was detected. Furthermore, dCRBSI14 incidence (2.0 vs. 3.2/1000 CVC days), dpCRBSI14 incidence (5.4 vs. 5.6/1000 CVC days), and overall CRBSI incidence (5.5 vs. 6.0/1000 CVC days) showed no significant differences. CONCLUSIONS: CRBSI rates were not reduced by the use of CHG gel dressings in patients with hematologic malignancies and/or ASCT.


Assuntos
Infecções Relacionadas a Cateter , Cateterismo Venoso Central , Cateteres Venosos Centrais , Neoplasias Hematológicas , Transplante de Células-Tronco Hematopoéticas , Sepse , Adulto , Humanos , Cateteres Venosos Centrais/efeitos adversos , Transplante de Células-Tronco Hematopoéticas/efeitos adversos , Análise por Pareamento , Infecções Relacionadas a Cateter/diagnóstico , Infecções Relacionadas a Cateter/epidemiologia , Infecções Relacionadas a Cateter/etiologia , Transplante Autólogo , Neoplasias Hematológicas/complicações , Neoplasias Hematológicas/terapia , Bandagens , Cateterismo Venoso Central/efeitos adversos
9.
Pediatr Blood Cancer ; 70(1): e30029, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36331108

RESUMO

BACKGROUND: Central venous access devices (CVAD) are vital for cancer therapeutics in pediatric oncology. Tunneled vascular access devices (TVAD) are preferred in children for prolonged and frequent vascular access. Data on insertion, care, and complications of CVAD in children from low middle-income countries (LMIC) are scarce, heterogeneous, and retrospective. PROCEDURE: This prospective observational study on eligible children <12 years with pediatric malignancies requiring chemotherapy for minimum 6 months from diagnosis excluded children with mucosal bleeding, coagulopathy, and infections. TVAD insertion was ultrasound (USG) guided. Number of catheter-days, surgical and nonsurgical complications, and risk factors for catheter-related bloodstream infections (CRBSI) were noted TVAD removal due to complications, therapy completion, tumor progression, or death. RESULTS: Data from 61 of 86 eligible children with median age 42 months (range 1-144) were analyzed. Hematological malignancy and severe thrombocytopenia were seen in 37/61 (61%) and 18/61 (30%) children, respectively. First-attempt success rate was 74%. Surgical complications were seen in four of 61 (7%). Nonsurgical complications were seen in 33/61 (54%) children; CRBSI was commonest 24/61 (39%), causing removal of TVAD in 14/61 (23%). Incidence per 1000 catheter-days for CRBSI was 3.24. Antibiotic lock therapy could salvage nine of 24 TVAD with CRBSI. Thrombus and accidental removal was seen in six of 61 (10%) and four of 61 (7%). None of the studied risk factors were significantly associated with CRBSI. The mean insertion duration of TVAD was 121 ± 90 days. CONCLUSION: USG-guided TVAD insertion is safe and reliable way for chemotherapy administration with acceptable complications in children with malignancies in LMIC, including children with severe thrombocytopenia.


Assuntos
Infecções Relacionadas a Cateter , Cateterismo Venoso Central , Cateteres Venosos Centrais , Neoplasias , Trombocitopenia , Humanos , Lactente , Pré-Escolar , Criança , Cateteres Venosos Centrais/efeitos adversos , Estudos Prospectivos , Cateterismo Venoso Central/efeitos adversos , Infecções Relacionadas a Cateter/epidemiologia , Infecções Relacionadas a Cateter/etiologia , Estudos Retrospectivos , Neoplasias/terapia , Neoplasias/etiologia , Ultrassonografia de Intervenção , Trombocitopenia/etiologia
10.
Ann Clin Microbiol Antimicrob ; 22(1): 97, 2023 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-37940983

RESUMO

BACKGROUND: Tsukamurella spp. are obligate aerobic, gram-positive, non-motile, and slightly acid-fast bacilli belonging to the Actinomycetes family. They share many characteristics with Nocardia, Rhodococcus, Gordonia, and the rapidly growing Mycobacterium species. Therefore, standard testing may misidentify Tsukamurella spp. as another species. Accurate and rapid diagnosis is critical for proper infection management, but identification of this bacterium is difficult in the standard laboratory setting. CASE PRESENTATION: A bloodstream infection caused by a gram-positive bacterium and related to a central venous catheter was identified in an immunocompromised 2-year-old girl. Tsukamurella tyrosinosolvens was identified by modified secA1 sequencing. Antibiotic treatment and removal of the central venous catheter resolved the infection. Inappropriate management of the catheter during an overnight stay outside of the hospital was considered as a possible source of infection. CONCLUSIONS: SecA1 sequencing may be a useful diagnostic tool in the identification of T. tyrosinosolvens. Providing proper central venous catheter care instructions to patients, their families, and medical staff is important for infection prevention.


Assuntos
Actinobacteria , Actinomycetales , Infecções Relacionadas a Cateter , Cateteres Venosos Centrais , Sepse , Pré-Escolar , Feminino , Humanos , Actinobacteria/genética , Actinomycetales/genética , Bactérias Aeróbias , Infecções Relacionadas a Cateter/diagnóstico , Infecções Relacionadas a Cateter/tratamento farmacológico , Infecções Relacionadas a Cateter/microbiologia , Sepse/microbiologia
11.
Int J Med Sci ; 20(5): 566-571, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37082737

RESUMO

In Japan, China, and Singapore, several studies have reported increased incidences of peripheral venous catheter-related bloodstream infection by Bacillus cereus during the summer. Therefore, we hypothesized that bed bathing with a B. cereus-contaminated "clean" towels increases B. cereus contact with the catheter and increases the odds of contaminating the peripheral parenteral nutrition (PPN). We found that 1) professionally laundered "clean" towels used in hospitals have B. cereus (3.3×104 colony forming units (CFUs) / 25cm2), 2) B. cereus is transferable onto the forearms of volunteers by wiping with the towels (n=9), and 3) B. cereus remain detectable (80∼660 CFUs /50cm2) on the forearms of volunteers even with subsequent efforts of disinfection using alcohol wipes. We further confirmed that B. cereus grow robustly (102 CFUs /mL to more than 106 CFUs /mL) within 24hours at 30°C in PPN. Altogether we find that bed bathing with a towel contaminated with B. cereus leads to spore attachments to the skin, and that B. cereus can proliferate at an accelerated rate at 30°C compared to 20°C in PPN. We therefore highly recommend ensuring the use of sterile bed bath towels prior to PPN administration with catheter in patients requiring bed bathing.


Assuntos
Infecção Hospitalar , Sepse , Humanos , Bacillus cereus , Soluções de Nutrição Parenteral , Infecção Hospitalar/epidemiologia , Infecção Hospitalar/etiologia , Infecção Hospitalar/prevenção & controle , Hospitais , Nutrição Parenteral/efeitos adversos , Fatores de Risco , Catéteres
12.
Nephrology (Carlton) ; 28(4): 249-253, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36715242

RESUMO

Catheter-related bloodstream infection (CRBI) is an important complication of catheter use for haemodialysis, but it remains unclear whether clinical outcomes following CRBI are influenced by organism type. This study aims to compare clinical outcomes following CRBI from Gram-positive and non-Gram-positive organisms. This was a retrospective cohort study of patients with kidney failure receiving haemodialysis (HD) via vascular catheters who had a documented episode of CRBI in Western Australia between 2005 and 2018. The associations between organism type, likelihood of hospitalization, catheter removal and death from CRBI were examined using adjusted logistic regression models. There were 111 episodes of CRBI in 99 patients (6.1 episodes per 1000-catheter-days at risk). Of the study cohort, 53 (48%) were male and 38 (34%) identified as Aboriginal or Torres Strait Islander. Gram-positive organisms were identified in 73 (66%) CRBI episodes, most commonly Staphylococcus aureus. Of those with non-Gram-positive CRBI, 9 (24%) were attributed to Pseudomonas aeruginosa. One-hundred and two (92%) episodes of CRBI required hospitalization and 15 (13%) patients died from CRBI. Compared with non-Gram-positive CRBI, Gram-positive CRBI was associated with an increased risk of hospitalization and catheter removal, with adjusted odds ratio of 9.34 (95% CI 1.28-68.03) and 3.47 (95% CI 1.25-9.67), respectively. There was no association between organism type and death from CRBI. Staphylococcus aureus remains the most common organism causing CRBI in HD patients. CRBI is associated with substantial morbidity, particularly CRBI attributed to Gram-positive organisms.


Assuntos
Infecções Relacionadas a Cateter , Diálise Renal , Dispositivos de Acesso Vascular , Feminino , Humanos , Masculino , Infecções Relacionadas a Cateter/diagnóstico , Infecções Relacionadas a Cateter/epidemiologia , Infecções Relacionadas a Cateter/terapia , Diálise Renal/efeitos adversos , Estudos Retrospectivos , Infecções Estafilocócicas , Dispositivos de Acesso Vascular/efeitos adversos , Austrália Ocidental/epidemiologia
13.
BMC Nephrol ; 24(1): 294, 2023 10 06.
Artigo em Inglês | MEDLINE | ID: mdl-37803308

RESUMO

BACKGROUND: We herein described the coexistence of hemophagocytic lymphohistiocytosis (HLH) and histiocytic necrotizing lymphadenitis, alternatively known as the Kikuchi disease (KD), secondary to hemodialysis catheter-related bloodstream infection (BSI) caused by Corynebacterium striatum. CASE PRESENTATION: A patient on maintenance hemodialysis had developed persistent fever and Corynebacterium striatum was subsequently identified from the culture of both catheter tip and peripheral blood. During mitigation of the BSI, however, his fever was unabated and ensuing workup further found thrombocytopenia, hyperferritinemia, hypertriglyceridemia, low NK cell activity and a surge in serum CD25 levels. Moreover, biopsy of the bone marrow and lymph node detected histopathological evidence of hemophagocytosis and KD, respectively. Upon these abnormalities, the title-bound diagnosis was considered and the patient was eventually recovered from the treatment of dexamethasone instead of antibiotics. Consistently, aberrations in his serum CD25 levels and NK cell activity had subsided two months after discharge. CONCLUSIONS: Arguably, this encounter offered a unique chance to unravel the principal pathogenic cascade in immunobiology that made the three entities one disease continuum. As such, our work may add new understandings of HLH and/or KD secondary to severe infections in general and excessive release of cytokines in particular among patients with kidney diseases. The resultant early diagnosis is crucial to initiate appropriate treatment and improve the survival of patients with these challenging and potentially life-threatening disorders.


Assuntos
Linfadenite Histiocítica Necrosante , Linfo-Histiocitose Hemofagocítica , Sepse , Humanos , Linfadenite Histiocítica Necrosante/complicações , Linfadenite Histiocítica Necrosante/diagnóstico , Linfo-Histiocitose Hemofagocítica/etiologia , Linfo-Histiocitose Hemofagocítica/complicações , Diálise Renal/efeitos adversos , Sepse/complicações
14.
Niger J Clin Pract ; 26(8): 1097-1100, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37635602

RESUMO

Backgrounds: Among various vascular access devices, midline catheters (MCs) are commonly used in emergency departments, but rarely in operating rooms. Aims: To evaluate the feasibility and safety of MCs in the operating room. Materials and Methods: This was a retrospective study. The medical records of patients who underwent MC placement in the operating room from October 2020 to July 2022 were reviewed. The rates of successful catheter insertion as well as major and minor complications were assessed. Results: Successful catheter insertions were achieved in 149 of 161 patients (92.5%). The median dwell time of midlines was eight days (IQR: 6-10 days). A major or minor complication occurred in 6.7% of the midlines. The rates of major complications of occlusion, upper extremity deep vein thrombosis (DVT), and catheter-related bloodstream infection were 1.3%, 0.7%, and 0%, respectively. Conclusions: Placement of MCs in the operating room was feasible and safe. Also, the procedure provides an acceptable alternative for replacing central line catheters and peripherally inserted central catheters.


Assuntos
Catéteres , Salas Cirúrgicas , Humanos , Estudos Retrospectivos , Serviço Hospitalar de Emergência , Prontuários Médicos
15.
J Anaesthesiol Clin Pharmacol ; 39(3): 349-354, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38025573

RESUMO

Background and Aims: There is a huge load of central line-associated bloodstream infection (CLABSI) being reported in developing countries, with increased mortality and healthcare costs. Effective surveillance is a must to reduce the incidence of CLABSI. The current criteria (Centre for Disease Control and Prevention/National Healthcare Safety Network [CDC/NHSN]) for CLABSI surveillance have their own shortcomings. For diagnosing CLABSI, current CDC/NHSN CLABSI surveillance criteria are laborious and time consuming with low predictive power. Hence, modified criteria have been postulated, which are simple and implementable at resource-constrained setups. The primary objective was to compare modified criteria with CDC criteria. The secondary objective was to determine the prevalence of CRBSI. Material and Methods: A total of 98 patients with central line in situ or having the central venous line removed ≤24 hrs prior to the date of the event were enrolled. Paired blood cultures were obtained and results were analyzed using differential time to positivity. Results: The incidence of CLBSI was 8.16% and the device utilization rate was 11.6%. The negative predictive value of both the surveillance criteria was found to be excellent and comparable (96.2% for modified criteria and 97.1% for CDC criteria), therefore both can be used for screening purposes. AUC for current CDC/NHSN criteria was better than modified criteria (0.76 versus 0.66, P < 0.0001), suggesting it to be a better criterion for surveillance of CLABSI. Conclusion: Modified criteria were not superior to CDC/NHSN criteria for surveillance. Thus, there is a scope of improving the modified criteria for the purpose of surveillance. CLBSI load was higher; CLABSI bundle for prevention is thus highly recommended.

16.
Ann Hematol ; 101(10): 2317-2324, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35978182

RESUMO

Although not generally recommended, scheduled central venous catheter (CVC) removal is sometimes carried out in order to reduce the CVC-related bloodstream infection (CRBSI) incidence. We conducted a simulation for scheduled CVC removal within the multicenter CRBSI registry (SECRECY). Non-tunneled jugular and subclavian CVC in patients with hematological disease or with germ cell tumors (including patients receiving autologous stem cell transplantation [SCT]) were included. Cases were randomized in a 1:1:1:1 ratio to either a simulated, scheduled CVC removal after 7, 14, and 21 days, or to non-simulated, unscheduled CVC removal (control group). The primary endpoint was definitive CRBSI incidence for a scheduled CVC removal after 14 days (dCRBSI-D14rmv). Among other, secondary endpoints were definite CRBSI incidence for a scheduled removal after 7 days (dCRBSI-D7rmv) and 21 days (dCRBSI-D21rmv). Data on 2984 CVC were included. Patients' median age was 59 (range 16-95) years, 58.8% being male. The vast majority (98.4%) were patients with hematological malignancies. Jugular veins were the main insertion site (93.2%). dCRBSI-D14rmv was 3.10/1000 CVC days as compared to 4.15/1000 CVC days in the control group (p = 0.23). There was a significant difference between dCRBSI-D7rmv (0.86/1000 CVC days) and controls (p < 0.001), but not between dCRBSI-D21rmv (4.10/1000 CVC days) and controls (p = 0.96). Our data suggest that in patients with hematological diseases or autologous SCT recipients scheduled CVC removal after 14 days does not result in a lower CRBSI incidence compared to unscheduled removal.Trial registration: DRKS00006551, 2014/09/29, retrospectively registered.


Assuntos
Infecções Relacionadas a Cateter , Cateterismo Venoso Central , Cateteres Venosos Centrais , Neoplasias Hematológicas , Transplante de Células-Tronco Hematopoéticas , Sepse , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Infecções Relacionadas a Cateter/epidemiologia , Infecções Relacionadas a Cateter/prevenção & controle , Cateterismo Venoso Central/efeitos adversos , Cateteres Venosos Centrais/efeitos adversos , Feminino , Neoplasias Hematológicas/terapia , Transplante de Células-Tronco Hematopoéticas/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Transplante Autólogo , Adulto Jovem
17.
BMC Infect Dis ; 22(1): 335, 2022 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-35382751

RESUMO

BACKGROUND: Aureobasidium melanigenum is a ubiquitous dematiaceous fungus that rarely causes invasive human infections. Here, we present a case of Aureobasidium melanigenum bloodstream infection in a 20-year-old man with long-term catheter use. CASE PRESENTATION: A 20-year-old man receiving home care with severe disabilities due to cerebral palsy and short bowel syndrome, resulting in long-term central venous catheter use, was referred to our hospital with a fever. After the detection of yeast-like cells in blood cultures on day 3, antifungal therapy was initiated. Two identification tests performed at a clinical microbiological laboratory showed different identification results: Aureobasidium pullulans from matrix-assisted laser desorption/ionization time-of-flight mass spectrometry, and Cryptococcus albidus from a VITEK2 system. Therefore, we changed the antifungal drug to liposomal amphotericin B. The fungus was identified as A. melanigenum by DNA sequence-based analysis. The patient recovered with antifungal therapy and long-term catheter removal. CONCLUSION: It is difficult to correctly identify A. melanigenum by routine microbiological testing. Clinicians must pay attention to the process of identification of yeast-like cells and retain A. melanigenum in cases of refractory fungal infection.


Assuntos
Cateteres Venosos Centrais , Micoses , Sepse , Adulto , Antifúngicos/uso terapêutico , Aureobasidium , Humanos , Masculino , Micoses/tratamento farmacológico , Sepse/tratamento farmacológico , Adulto Jovem
18.
BMC Infect Dis ; 22(1): 622, 2022 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-35843933

RESUMO

BACKGROUND: Catheter-related bloodstream infection (CRBSI) is associated with increased morbidity, mortality, and cost of treatment in critically ill patients. A differential time to positivity (DTP) of 120 min or more between blood cultures obtained through the catheter vs. peripheral vein is an indicator of CRBSI with high sensitivity and specificity. However, it is no clear whether pooled sampling would be as efficient as individual sampling in order to reduce costs, contamination, or anemia. METHODS: This was a prospective diagnostic study conducted at the medical ICU and semi-ICU of Khon Kaen University's Srinagarind Hospital in Thailand from May 2020 to November 2021. Fifty patients with triple-lumen central venous catheters (CVCs) who were clinically suspected of CRBSI were enrolled. 15 mL of blood was drawn through each catheter lumen, 10 mL of which was inoculated into three blood culture bottles, and the remaining 5 mL was pooled into a single bottle. Sensitivity, specificity, accuracy, and time to positivity of the pooled blood cultures were calculated using individual blood cultures as a reference. RESULTS: Of the 50 patients enrolled, 14 (28%) were diagnosed with CRBSI, 57.9% of whom were infected with gram-negative bacteria as the causative pathogen (57.9%). Extensively drug-resistant (XDR) Klebsiella pneumoniae was the most common organism. Sensitivity and specificity of the pooled blood sampling method were 69.23% (95% CI [0.44-0.94]) and 97.3% (95% CI [0.92-1.02]), respectively. The area under the ROC curve (AUC) was 0.83 (95% CI [0.68-0.99]). A paired T-Test to compare time to positivity of the pooled blood bottle and the first positive culture from the individual bottles indicated statistical significance (14.9 and 12.4 h, respectively). The mean difference was 2.5 [0.9-4.1] h, with a 95% CI and a p-value of 0.006. CONCLUSION: Pooled blood sampling results in a lower sensitivity and longer time to positivity for CRBSI diagnosis in patients with triple-lumen CVCs than individual lumen sampling. Trial registration Retrospectively registered at Thai Clinical Trials Registry. The study was reviewed and approved on 08/03/2022. TCTR identification number is TCTR20220308002.


Assuntos
Bacteriemia , Infecções Relacionadas a Cateter , Cateterismo Venoso Central , Bacteriemia/diagnóstico , Bacteriemia/microbiologia , Hemocultura , Infecções Relacionadas a Cateter/diagnóstico , Infecções Relacionadas a Cateter/microbiologia , Catéteres , Humanos , Estudos Prospectivos , Tailândia , Fatores de Tempo
19.
Artif Organs ; 46(9): 1937-1941, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35866981

RESUMO

When sodium citrate is used as an anticoagulant catheter lock the best concentration is 7%, since this provides a density approximately the same as blood. Our laboratory found that the addition of methylene blue and parabens greatly augmented antibacterial properties. Ash Access sponsored a randomized clinical trial in 400 dialysis patients with tunneled CVC, and this showed a significant decrease in incidence of catheter-related bloodstream infection (CRBSI) defined by stringent criteria. The FDA decided that the study missed its primary endpoint, and that the product was mis-classified, so they did not give approval to market. The licensee decided not to appeal to the decision to the physician panel and ended support of the project. Rights to market the catheter lock eventually returned to Ash Access.


Assuntos
Anti-Infecciosos Locais , Infecções Relacionadas a Cateter , Cateterismo Venoso Central , Cateteres Venosos Centrais , Anti-Infecciosos Locais/uso terapêutico , Anticoagulantes , Infecções Relacionadas a Cateter/etiologia , Infecções Relacionadas a Cateter/prevenção & controle , Cateterismo Venoso Central/efeitos adversos , Cateteres Venosos Centrais/efeitos adversos , Humanos , Diálise Renal/efeitos adversos
20.
J Infect Chemother ; 28(9): 1332-1335, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35637129

RESUMO

In the treatment of head and neck cancer, radiation therapy is an effective modality and is often used in routine clinical practice. Although rare, pyogenic spondylitis has been reported as a complication of radiation therapy. Here, we report a case of nasopharyngeal carcinoma resulting in pyogenic spondylitis from a catheter-related bloodstream infection after chemoradiotherapy. The initial symptoms were fever and posterior cervical pain. Streptococcus dysgalactiae subspecies equisimilis was detected in blood cultures. Magnetic resonance imaging showed abnormal enhancement of the C6 and C7 vertebrae and an anterior epidural abscess. The infection was successfully treated with antibacterial therapy.


Assuntos
Neoplasias Nasofaríngeas , Espondilite , Infecções Estreptocócicas , Humanos , Carcinoma Nasofaríngeo/complicações , Neoplasias Nasofaríngeas/complicações , Espondilite/diagnóstico por imagem , Infecções Estreptocócicas/microbiologia , Streptococcus
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA