1.
Artif Organs ; 48(7): 753-762, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38404240

RESUMO

BACKGROUND: New versions of the polyester polymer alloy (PEPA) membrane have appeared over the years, with increases in both the pore size and the amount of polyvinylpyrrolidone (PVP) to optimize hydrophilicity performance. This study aimed to assess the efficacy of the most recently developed PEPA dialyzer, the FDY series, in hemodialysis (HD) modality in terms of uremic toxin removal and albumin loss and to compare it with that of several high-flux dialyzers currently used in HD and post-dilution hemodiafiltration (HDF) treatments. METHODS: A prospective study was carried out in 21 patients. All patients underwent six dialysis sessions with the same routine dialysis parameters; only the dialyzer and/or the dialysis modality varied: FX80 in HD, FDY 180 in HD, Clearum HS17 in HDF, Elisio 19H in HDF, Vitapes 180 in HDF, and FX80 in post-dilution HDF. The reduction ratios (RR) of urea, creatinine, ß2-microglobulin, myoglobin, κFLC, prolactin, α1-microglobulin, α1-acid glycoprotein, λFLC, and albumin were compared intraindividually. Dialysate albumin loss was also measured. RESULTS: Both membranes FDY and FX80 are high-flux dialyzers and are applied here in high-flux HD. The average RR of ß2-microglobulin was slightly lower in the two HD treatments than in the HDF treatments. Comparison of dialysis treatments revealed that the PEPA FDY dialyzer in the HD modality was more effective than the FX80 dialyzer in high-flux HD and was as effective as post-dilution HDF, especially in terms of myoglobin, κFLC, prolactin, α1-microglobulin, and λFLC RRs. The FDY treatments obtained similar albumin RR in blood and slightly higher dialysate albumin loss, although the values were clinically acceptable. CONCLUSIONS: The most recently developed PEPA dialyzers in the HD modality were as effective as all treatments in the HDF modality and were clearly superior to high-flux helixone HD treatment. These results confirm that this dialyzer should be categorized within the medium cut-off (MCO) membrane classification.


Assuntos
Membranas Artificiais , Poliésteres , Diálise Renal , Humanos , Masculino , Diálise Renal/instrumentação , Diálise Renal/métodos , Pessoa de Meia-Idade , Feminino , Idoso , Estudos Prospectivos , Poliésteres/química , Ligas/química , Idoso de 80 Anos ou mais , Hemodiafiltração/instrumentação , Hemodiafiltração/métodos , Adulto , Polímeros/química
2.
Artif Organs ; 48(4): 365-374, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37962073

RESUMO

BACKGROUND: Clearum™ is a high flux steam sterilized dialyzer for patients with hemodialysis or hemodiafiltration. This study evaluated the safety and performance of the Clearum high flux steam sterilized hemodialyzer in the removal of small and middle-sized toxins. METHODS: A prospective, interventional, nonrandomized study enrolled twenty end-stage renal disease patients undergoing hemodialysis. The Clearum high flux steam sterilized dialyzer was compared to Fresenius FX dialyzers for baseline comparison. The duration of the trial was 2 weeks for the FX dialyzer and 6 weeks with the Clearum high flux steam sterilized dialyzer. In vitro studies with dextrans of varying sizes were performed to compare the membrane characteristics and sieving coefficient curves for the two dialyzers. RESULTS: The primary objective of a mean urea reduction ratio >65% was met, with no significant difference in mean urea reduction ratio between the Clearum high flux steam sterilized and Fresenius FX-series of dialyzers (p = 0.86). No dialyzer-related adverse events were reported in the study. ß-2-microglobulin reduction with the Clearum high flux steam sterilized dialyzer was statistically higher than the FX-series dialyzer (66.5% vs. 53.6%; p < 0.0001). Predialysis interleukin-6 and C-reactive protein concentrations, blood-rest scores (residual blood after blood restitution), and thrombin-anti-thrombin values were comparable. Albumin remained stable during the 6 weeks of Clearum high flux steam sterilized dialyzer use, with no appreciable differences compared to the Fresenius FX-series. CONCLUSION: The Clearum high flux steam sterilized dialyzer showed good mid-term effectivity for small and middle molecule removal with no reported dialyzer-related adverse events.


Assuntos
Rins Artificiais , Humanos , Estudos Prospectivos , Vapor , Diálise Renal/efeitos adversos , Membranas Artificiais , Ureia
3.
Blood Purif ; 53(3): 219-228, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38142670

RESUMO

INTRODUCTION: Medium cut-off (MCO) membranes may be able to remove middle-large uremic toxins that are retained in the body, which has been linked to various risk factors including malnutrition-inflammation score (MIS). The effect of MCO dialyzers on MIS has been studied. METHODS: This single-center exploratory prospective observational study enrolled maintenance hemodialysis patients who underwent dialysis using either MCO (Theranova 400) or high-flux (FX80) membranes as part of their regular care. Measurements of MIS, body weight, height, body mass index, and various biochemical markers were taken at the beginning and conclusion of the study. RESULTS: This study included 50 patients who were treated with either the Theranova 400 (n = 25) or the FX80 (n = 25) for a period of 6 months. The two groups were similar in terms of demographics, duration of hemodialysis treatment, and baseline biochemical test results. Theranova 400 had no significant impact on the median MIS (6 [6-10] vs. 7 [5-10], p 0.575) and serum albumin levels (4.07 [3.92-4.22] vs. 4.04 [3.85-4.30], p 0.689), while the FX80 resulted in a significant increase in MIS (6 [5-8] vs. 8 [6-10], p 0.033) and a significant decrease in serum albumin levels (4.23 [4.03-4.36] vs. 3.98 [3.77-4.12], p 0.027) at the end of the study. DISCUSSION/CONCLUSION: After 6 months of treatment, the MCO dialyzer did not demonstrate a statistically significant difference in the MIS when compared to the high-flux dialyzer. However, MIS worsening was significantly less in the MCO group, indicating the potential benefits of MCO membranes in maintaining nutritional status. Further research is required to validate these results.


Assuntos
Cefalosporinas , Desnutrição , Diálise Renal , Humanos , Diálise Renal/efeitos adversos , Diálise Renal/métodos , Inflamação/etiologia , Desnutrição/etiologia , Desnutrição/terapia , Albumina Sérica
4.
BMC Nephrol ; 25(1): 220, 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38987671

RESUMO

BACKGROUND: Hemodialyzers should efficiently eliminate small and middle molecular uremic toxins and possess exceptional hemocompatibility to improve well-being of patients with end-stage kidney disease. However, performance and hemocompatibility get compromised during treatment due to adsorption of plasma proteins to the dialyzer membrane. Increased membrane hydrophilicity reduces protein adsorption to the membrane and was implemented in the novel FX CorAL dialyzer. The present randomized controlled trial compares performance and hemocompatibility profiles of the FX CorAL dialyzer to other commonly used dialyzers applied in hemodiafiltration treatments. METHODS: This prospective, open, controlled, multicentric, interventional, crossover study randomized stable patients on post-dilution online hemodiafiltration (HDF) to FX CorAL 600, FX CorDiax 600 (both Fresenius Medical Care) and xevonta Hi 15 (B. Braun) each for 4 weeks. Primary outcome was ß2-microglobulin removal rate (ß2-m RR). Non-inferiority and superiority of FX CorAL versus comparators were tested. Secondary endpoints were RR and/or clearance of small and middle molecules, and intra- and interdialytic profiles of hemocompatibility markers, with regards to complement activation, cell activation/inflammation, platelet activation and oxidative stress. Further endpoints were patient reported outcomes (PROs) and clinical safety. RESULTS: 82 patients were included and 76 analyzed as intention-to-treat (ITT) population. FX CorAL showed the highest ß2-m RR (76.28%), followed by FX CorDiax (75.69%) and xevonta (74.48%). Non-inferiority to both comparators and superiority to xevonta were statistically significant. Secondary endpoints related to middle molecules corroborated these results; performance for small molecules was comparable between dialyzers. Regarding intradialytic hemocompatibility, FX CorAL showed lower complement, white blood cell, and platelet activation. There were no differences in interdialytic hemocompatibility, PROs, or clinical safety. CONCLUSIONS: The novel FX CorAL with increased membrane hydrophilicity showed strong performance and a favorable hemocompatibility profile as compared to other commonly used dialyzers in clinical practice. Further long-term investigations should examine whether the benefits of FX CorAL will translate into improved cardiovascular and mortality endpoints. TRIAL REGISTRATION: eMPORA III registration on 19/01/2021 at ClinicalTrials.gov (NCT04714281).


Assuntos
Estudos Cross-Over , Hemodiafiltração , Interações Hidrofóbicas e Hidrofílicas , Membranas Artificiais , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Hemodiafiltração/instrumentação , Hemodiafiltração/métodos , Estudos Prospectivos , Microglobulina beta-2/sangue , Falência Renal Crônica/terapia
5.
Artif Organs ; 47(9): 1514-1521, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37186470

RESUMO

BACKGROUND: The introduction of high flux (HF) hemodialyzers and their application in single dialyzer hemodiafiltration (sdHDF) for patients on extracorporeal dialysis (ECD) therapy has improved the extraction of uremic toxins, including the low molecular weight protein (LMWP) beta 2 microglobulin (ß2M, 11.6 kDa). Similar increases in the extraction of protein-bound uremic toxins (PBUT) and larger LMWP (15-50 kDa) remain elusive. High concomitant losses of albumin prohibit the use of medium cutoff (MCO) or protein-losing hemodialyzers for sdHDF to increase the extraction of these molecules by convective transfer. METHODS: A new extracorporeal dialysis treatment modality, dual dialyzer hemodiafiltration (ddHDF), has been designed together with a mathematical model to compare its predicted performance to that of sdHDF in the extraction of solute. The extra process that distinguishes ddHDF from sdHDF is the secondary ultrafiltration and partial reinfusion of the effluent hemodiafiltrate from the primary hemodialyzer. This allows MCO and protein-losing hemodialyzers to be used to increase the extraction of both LMWP and PBUT without excessive concomitant loss of albumin. RESULTS: Data from the mathematical model show that ddHDF could increase the extraction of smaller and larger LMWP by an extra 102% and 220%, respectively, compared to standard HF sdHDF, while restricting the loss of albumin to 0.83 g per hour of treatment. In using albumin as a recyclable carrier molecule for the extraction of PBUT from plasma ddHDF has the potential to increase PBUT reduction ratios (RR's) to 49% by convection alone. Even higher RR's are possible if the dialysate volume flow rate can be increased beyond 600 mL/min. CONCLUSION: ddHDF provides an opportunity for a step change increase in the level of extraction of both larger LMWP and PBUT in patients with end-stage kidney disease.


Assuntos
Hemodiafiltração , Falência Renal Crônica , Humanos , Toxinas Urêmicas , Diálise Renal , Falência Renal Crônica/terapia , Albuminas
6.
Blood Purif ; 52(1): 68-74, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35551384

RESUMO

INTRODUCTION: The medium cut-off Elisio HX dialyzer by Nipro became commercially available in Europe in 2021, but there are still no reports of in vivo data. This study aimed to evaluate the safety and efficacy of it compared with previously evaluated hemodialysis (HD), expanded HD (HDx), and postdilution hemodiafiltration (HDF) treatments. METHODS: A prospective study was carried out on 18 patients who underwent 5 dialysis sessions: FX80 Cordiax in HD, Elisio H19 in HD, Elisio HX19 in HDx, Theranova 400 in HDx, and FX80 Cordiax in HDF. The reduction ratios of urea, creatinine, ß2-microglobulin, myoglobin, kappa FLC, prolactin, α1-microglobulin, α1-acid glycoprotein, lambda FLC, and albumin were compared. Dialysate albumin loss was measured. RESULTS: The comparison between the different dialysis modalities revealed no difference for small molecules, but HDx and HDF were significantly more efficient than HD for medium and large molecule removal. The efficacy of Elisio HX19 dialyzer in HDx was similar to the Theranova 400, superior to both dialyzers in HD, and slightly lower than HDF. Albumin losses in dialysate with HD dialyzers were less than 1 g, but between 1.5 and 2.5 g in HDx and HDF. The global removal score (GRS) values with HDx treatments were statistically significantly higher than those with HD. The highest GRS was obtained with the helixone dialyzer in HDF. CONCLUSIONS: The new MCO dialyzer, Elisio HX, performs with excellent behavior and tolerance. It represents an upgrade compared to their predecessor and is very close to the removal capacity of HDF treatment.


Assuntos
Hemodiafiltração , Diálise Renal , Humanos , Estudos Prospectivos , Hemodiafiltração/efeitos adversos , Albuminas , Soluções para Diálise
7.
Blood Purif ; 52(3): 233-241, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36502799

RESUMO

Uremic toxins contribute to clinical manifestations of kidney dysfunction. These toxins include organic and inorganic elements or compounds. While the kidney typically clears uremic toxins, gut dysbiosis, and tissue inflammation could lead to increased production of substances that can further the clinical manifestations of uremia. The uremic toxins are quantitatively measurable in biological fluids and have an established relationship with azotemia signs and symptoms. Their elimination is associated with mitigated uremic manifestations, while their administration to the uremic levels leads to uremic signs in animal or human models or in vitro studies. Besides, the uremic toxins have an established and plausible pathophysiologic relationship with uremic manifestations. The previous classification of uremic toxins was mainly focused on the physicochemical characteristics of these substances to divide them into three categories, (1) free water-soluble low-molecular-weight (<500 Da) solutes, (2) protein-bound, water-soluble, low molecular weight (<500 Da), (3) middle molecular weight (>500 Da and <12,000 Da), and (4) high molecular weight (>12,000 Da). Unfortunately, the classification named above was not centered around patient outcomes and quality of life among those with severe kidney failure. Therefore, a panel of experts convened virtually to provide additional insights into the current state and propose a new uremic toxin classification. This article describes the group's consensus recommendations regarding the new classification of uremic toxins into more clinically oriented categories.


Assuntos
Injúria Renal Aguda , Toxinas Biológicas , Uremia , Animais , Humanos , Toxinas Urêmicas , Qualidade de Vida , Uremia/terapia , Diálise Renal , Água
8.
Int J Mol Sci ; 24(13)2023 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-37445782

RESUMO

The mechanisms behind reported decreases in plasma insulin and glucagon during hemodialysis (HD) are not clear. Here, we investigated these mechanisms during HD treatment and the characteristics of insulin and glucagon removal when using two super high-flux membranes. In an experimental study, clearance, adsorption rates, and reduction rates of insulin and glucagon were investigated when using cellulose triacetate (CTA) and polysulfone (PS) membranes in a closed circuit using bovine blood. In a clinical study, 20 diabetes patients with end-stage kidney disease who were stable on HD were randomly selected for two HD sessions with two different membranes. At 1 h after the initiation of HD, insulin and glucagon clearance were measured, and the reduction rates were also investigated. In the experimental study, the PS membrane showed significantly higher clearance, adsorption rates, and reduction rates of insulin and glucagon compared with the CTA membrane. Although glucagon was detected in the ultrafiltration fluids in both membranes, insulin was absent in the PS membrane. In the clinical study, both membranes showed significant reductions in plasma insulin and glucagon at each time point. The PS membrane showed significantly higher insulin clearance and reduction rates compared with the CTA membrane. The two membranes showed no significant difference in glucagon clearance, but the glucagon reduction rate was significantly higher with the PS membrane. Our findings show that HD with the two super high-flux membranes used removes significant amounts of glucoregulatory peptide hormones from plasma in patients with diabetes and end-stage kidney disease, potentially affecting their glucose metabolism.


Assuntos
Diabetes Mellitus , Falência Renal Crônica , Humanos , Animais , Bovinos , Diálise Renal , Glucagon , Cinética , Falência Renal Crônica/terapia , Insulina , Insulina Regular Humana , Membranas Artificiais
9.
J Food Sci Technol ; 60(6): 1711-1722, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37187986

RESUMO

Chondroitin sulfate (ChS) from marine sources is gaining attention. The purpose of this study was to extract ChS from jumbo squid cartilage (Dosidicus gigas) using ultrasound-assisted enzymatic extraction (UAEE). An ultrasound with protease assistance, including either alcalase, papain or Protin NY100 was used to extract ChS. The results showed that alcalase had the best extraction efficiency. The response surface methodology was employed to evaluate the relationship between extraction conditions and extraction yield of ChS. The ridge max analysis revealed a maximum extraction yield of 11.9 mg ml- 1 with an extraction temperature of 59.40 °C, an extraction time of 24.01 min, a pH of 8.25, and an alcalase concentration of 3.60%. Compared to ethanol precipitation, purification using a hollow fiber dialyzer (HFD) had a higher extraction yield of 62.72% and purity of 85.96%. The structure characteristics of ChS were identified using FTIR, 1 H-NMR, and 13 C-NMR to confirm that the purified ChS structure was present in the form of chondroitin-4-sulfate and chondroitin-6-sulfate. The results of this study provide a green and efficient process for extraction and purification of ChS and are essential for the use of ChS for the development and production of nutrient food products or pharmaceuticals. Supplementary Information: The online version contains supplementary material available at 10.1007/s13197-023-05701-7.

10.
BMC Infect Dis ; 22(1): 79, 2022 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-35065604

RESUMO

BACKGROUND: Individuals with end-stage renal disease have a higher risk of hepatitis C virus (HCV) acquisition during long-term hemodialysis (HD). Our report was designed to investigate HCV prevalence and genotype, in addition to the clinical use of HCV core antigen (HCVcAg), within multiple HD facilities in Thailand. METHODS: This cross-sectional report was investigated between January and June 2019. HCV infection was assessed by anti-HCV and confirmed active infection by measuring HCV RNA and HCVcAg. HCV genotype was determined by phylogenetic analysis using nucleotide sequences of NS5B region. RESULTS: Overall, 140 of 3,305 (4.2%) patients in 15 dialysis centers had anti-HCV positive. Among them, HCV RNA was further assessed in 93 patients and was detectable in 59 (63.4%) persons. Considering HCV viremia, HCVcAg measurement exhibited high accuracy (96.8%), sensitivity (94.9%) and specificity (100%) in comparison with HCV RNA testing. Moreover, individuals infected with HCV received a longer duration of dialysis vintage when compared to anti-HCV negative controls. The major sub-genotypes were 1a, 1b, 3a, 3b, 6f and 6n. Regarding phylogenetic analysis, there were 7 clusters of isolates with high sequence homology affecting 17 individuals, indicating possible HCV transmission within the same HD centers. CONCLUSIONS: HCV frequency and common sub-genotypes in HD centers were different from those found in the Thai general population. HCVcAg might be an alternate testing for viremia within resource-limited countries. Enhanced preventive practices, dialyzer reuse policy and better access to antiviral therapy are crucial for HCV micro-elimination within HD facilities.


Assuntos
Hepacivirus , Hepatite C , Estudos Transversais , Genótipo , Hepacivirus/genética , Hepatite C/epidemiologia , Humanos , Filogenia , Prevalência , RNA Viral/genética , Diálise Renal , Tailândia , Viremia/epidemiologia
11.
Artif Organs ; 46(5): 775-785, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35028951

RESUMO

BACKGROUND: Hemodialysis (HD) using super high-flux dialyzer (HD + SHF) comparably removed uremic toxins to high-volume postdilution online hemodiafiltration (olHDF). Integration of hemoperfusion (HP) to HD + SHF (HD + SHF + HP) might provide superior uremic toxin removing capability to high-volume postdilution olHDF. METHOD: The present study was conducted in thrice-a-week HD patients to compare the efficacy in removing indoxyl sulfate (IS), beta-2 microglobulin (ß2 M), and urea between high-volume postdilution ol-HDF and HD + SHF + HP, comprising HD + SHF as the main treatment plus HD + SHF + HP 1/week in the first 4 weeks and 1/2 weeks in the second 4 weeks. RESULTS: Ten prevalent HD patients with blood flow rate (BFR) above 400 ml/min were randomized into two sequences of 8-week treatment periods of HD + SHF + HP and later high-volume postdilution olHDF or vice versa. When compared with high-volume postdilution olHDF (convective volume of 26.02 ± 1.8 L/session), HD + SHF + HP provided comparable values of percentage reduction ratio of IS (52.0 ± 11.7 vs. 56.3 ± 7.5%, p = 0.14) and ß2 M (83.7 ± 4.9 vs. 84.0 ± 4.3%, p = 0.37) and slightly lower urea reduction ratio. Despite greater dialysate albumin loss (p = 0.008), there was no significant change in serum albumin level in HD + SHF + HP group. CONCLUSIONS: HD + SHF + HP could not provide superior efficacy in removing uremic toxins to high-volume postdilution olHDF. The use of low BFR of 200 ml/min during the first 2 h of HD + SHF + HP session, according to the instruction of manufacturer, might impair the efficacy of the HD + SHF part in removing uremic toxins.


Assuntos
Hemodiafiltração , Hemoperfusão , Falência Renal Crônica , Hemodiafiltração/efeitos adversos , Humanos , Falência Renal Crônica/terapia , Diálise Renal/efeitos adversos , Ureia , Toxinas Urêmicas
12.
Artif Organs ; 46(7): 1318-1327, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35192209

RESUMO

BACKGROUND: Toxin removal capacity (i.e., performance) of a dialyzer is not constant but diminishes during treatment, as the adsorption of proteins to the membrane provides an additional barrier to uremic solutes. We investigated time-resolving molecular weight retention changes among synthetic high-flux dialyzers and compared the results with recent data from a randomized controlled trial. METHODS: In plasma recirculation experiments over 240 min, sieving coefficients (SC) for ß2-microglobulin, myoglobin, and albumin were determined for the FX CorAL (Fresenius Medical Care), ELISIO (Nipro), and xevonta (B. Braun). Molecular weight retention (MWR) curves were generated and the shifts over 120 min were characterized. Effective pore radius was determined, and the predicted albumin loss was compared with clinical data. RESULTS: SC decreased over time for all dialyzers (mean relative decrease across all dialyzers: ß2-microglobulin: 8.0% (120 min); myoglobin: 56.6% (240 min); albumin: 94.1% (240 min)). FX CorAL (7.3%, 52.6% and 91.1%) and ELISIO (7.7%, 51.0%, and 93.8%) showed a lower decrease than xevonta (9.0%, 66.2%, and 97.4%). For all dialyzers, MWR curves shifted toward lower molecular weight, with the lowest shift for FX CorAL (by 0.23 nm at SC50%, 120 min) and highest for xevonta (0.50 nm). FX CorAL had the highest slope over time and the smallest decrease in the effective pore radius (2 min: 2.31 nm, 120 min: 2.08 nm). Predicted albumin loss over 4 h was highest for xevonta (609.3 mg) and comparable between ELISIO (283.6 mg) and FX CorAL (313.3 mg). CONCLUSIONS: Substantial differences in the temporal performance profile of dialyzers exist. The present approach allows the characterization of dialyzer permeability changes over time using standard, clinically relevant protein markers.


Assuntos
Diálise Renal , Microglobulina beta-2 , Albuminas , Membranas Artificiais , Peso Molecular , Mioglobina , Diálise Renal/métodos
13.
Blood Purif ; 51(9): 772-779, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34814149

RESUMO

INTRODUCTION: There is insufficient data on the role of the medium cutoff (MCO) membranes in the clearance of pro-inflammatory cytokines and oxidant radicals in patients with sepsis requiring hemodialysis. METHODS: The study consisted of 38 septic patients who developed acute kidney injury (AKI) and who were scheduled to undergo 2 sessions of hemodialysis. Nineteen patients underwent their first dialysis session with the MCO membrane and 19 patients with the high-flux (HF) membrane. In the second session, the membranes were switched. Pro-inflammatory cytokine and oxidative marker levels were measured in blood samples obtained before and after both dialysis sessions. Reduction ratios were compared for the 2 types of hemodialysis membranes. RESULTS: After the first session, there was a greater reduction in tumor necrosis factor (TNF)-α with the MCO membrane (28.2 ± 21.1 vs. 8.0 ± 6.6, p = 0.001). After the second session, there was a greater reduction in interleukin (IL)-6 (27.8 ± 26.5 vs. 5.9 ± 13.3, p = 0.003) and IL-1ß (20.5 ± 21.1 vs. 4.0 ± 6.5, p = 0.004) with the MCO membrane. When the first and second sessions of all 38 patients were compared, the reductions in TNF-α, IL-6, and IL-1ß were consistently greater for MCO than HF (p = 0.001, p = 0.006, p < 0.001, respectively). The reductions in total antioxidant status, total oxidant status, and myeloperoxidase were not statistically different for the 2 types of dialysis membranes. CONCLUSIONS: MCO membrane was superior to HF membrane in the removal of cytokines in septic patients with AKI. However, a similar effect was not observed for oxidative stress markers.


Assuntos
Injúria Renal Aguda , Sepse , Injúria Renal Aguda/etiologia , Injúria Renal Aguda/terapia , Biomarcadores , Citocinas/metabolismo , Humanos , Interleucina-6 , Membranas Artificiais , Oxidantes , Estresse Oxidativo , Diálise Renal/efeitos adversos , Sepse/complicações , Fator de Necrose Tumoral alfa
14.
Blood Purif ; 51(11): 923-931, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35279655

RESUMO

INTRODUCTION: Expanded hemodialysis (HD using a medium cut-off dialyzer [HD + MCO]) provides comparable or better removal of various uremic toxins, particularly large middle-molecule uremic toxins, than post-dilution online hemodiafiltration (olHDF). Uremic toxin-removing effectiveness between HD + MCO and mixed-dilution olHDF, one of the currently most efficient olHDF modalities, has not been assessed. METHOD: This randomized controlled trial was conducted in 14 prevalent thrice-a-week HD patients with blood flow rate above 400 mL/min. The patients were randomized into two sequences of 2-week treatment periods of HD + MCO and later mixed-dilution olHDF or vice versa. The reduction ratio (RR) values of small-molecule as well as middle-molecule uremic toxins and protein-bound uremic toxins were measured at baseline and at the end of the treatment. RESULTS: When compared with mixed-dilution olHDF, HD + MCO provided slightly lower ß2M RR, but the value was still higher than 75%; showed similar κFLC RR, IS RR, and URR; and yielded significantly higher RR values of α1M (p < 0.001) and λFLC (p < 0.001). Despite higher albumin loss in HD + MCO, the serum albumin levels at the end of the study were comparable between both groups. CONCLUSION: Expanded HD (HD + MCO) provided similar effectiveness in removing various uremic toxins and could exhibit greater removal of large middle-molecule uremic toxins, such as α1M and λFLC. Expanded HD can be used as an effective alternative option for mixed-dilution olHDF.


Assuntos
Hemodiafiltração , Humanos , Diálise Renal/efeitos adversos , Toxinas Urêmicas , Estudos Prospectivos
15.
Am J Kidney Dis ; 77(5): 796-809, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33771393

RESUMO

Since maintenance hemodialysis (HD) first became available in the United States in 1962, there has been tremendous growth in the population of patients with kidney failure. HD has become a routine treatment carried out in outpatient clinics, hospitals, nursing facilities, and in patients' homes. Although it is a complex procedure, HD is quite safe. Serious complications are uncommon due to the use of modern HD machines and water treatment systems as well as the development of strict protocols to monitor various aspects of the HD treatment. The practicing nephrologist must be knowledgeable about life-threatening complications that can occur during HD and be able to recognize, manage, and prevent them. This installment in the AJKD Core Curriculum in Nephrology reviews the pathogenesis, management, and prevention of 9 HD emergencies. The HD emergencies covered include dialyzer reactions, dialysis disequilibrium syndrome, uremic/dialysis-associated pericarditis, air embolism, venous needle dislodgement, vascular access hemorrhage, hemolysis, dialysis water contamination, and arrhythmia episodes.


Assuntos
Emergências , Falência Renal Crônica/terapia , Diálise Renal/efeitos adversos , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/terapia , Edema Encefálico , Descontaminação , Soluções para Diálise/normas , Embolia Aérea/etiologia , Embolia Aérea/fisiopatologia , Embolia Aérea/terapia , Deslocamentos de Líquidos Corporais , Hemólise , Hemorragia/etiologia , Hemorragia/fisiopatologia , Hemorragia/terapia , Humanos , Hipersensibilidade/etiologia , Hipersensibilidade/fisiopatologia , Hipersensibilidade/terapia , Rins Artificiais/efeitos adversos , Agulhas , Nefrologia , Pericardite/etiologia , Pericardite/fisiopatologia , Pericardite/terapia , Falha de Prótese , Esterilização , Uremia/complicações , Purificação da Água/normas
16.
Artif Organs ; 45(9): E317-E323, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33908062

RESUMO

Toray has created a new generation of dialyzers, the polysulphone (TS) UL series, and polymethylmethacrylate (PMMA) NF-U series, which offer enhanced efficacy over the previous TS-S series and NF-H series. The aim of this study was to evaluate the safety and efficacy of these dialyzer series versus contrasted expanded hemodialysis (HDx) and postdilution hemodiafiltration (HDF). We conducted a prospective study in 12 patients. Each patient underwent six dialysis sessions: FX80 Cordiax in HD, Toraysulfone TS-1.8 UL in HD, Theranova 400 in HDx, polymethylmethacrylate (PMMA) NF-2.1 U in HDF, Toraysulfone TS-2.1 UL in HDF, and FX80 Cordiax in HDF. The removal ratios (RRs) of urea, creatinine, ß2 -microglobulin, myoglobin, prolactin, α1 -microglobulin, α1 -acid glycoprotein, and albumin were compared intraindividually. Dialysate albumin loss was also measured. The RRs for ß2 -microglobulin, myoglobin, prolactin, α1 -microglobulin, and α1 -acid glycoprotein were higher with the TS-2.1 UL and FX80 Cordiax dialyzers in HDF than those obtained with HD treatments and NF-2.1 U in HDF. The ß2 -microglobulin, myoglobin, and prolactin RRs were also higher with HDx than those obtained with HD treatments. The myoglobin and prolactin RRs were higher with TS-1.8 UL in HD than those obtained with helixone dialyzers in HD. Dialysate albumin loss was less than 3 g in all situations except in TS-2.1 UL in HDF. The highest global removal score values were obtained with the TS-2.1 UL and helixone dialyzers in HDF. Significant differences were found between all study situations. In conclusion, the new generation dialyzers, Toraysulfone TS Series UL and PMMA NF-U series, show excellent behaviour and tolerance in HD and HDF, representing an upgrade versus their predecessor series. The higher permeability of the TS UL series has been proven with higher efficiency in HD and maximum performance in HDF. The new PMMA NF-U series allows the use of HDF with good efficiency and complete safety.


Assuntos
Hemodiafiltração/instrumentação , Nefropatias/terapia , Membranas Artificiais , Polímeros/química , Polimetil Metacrilato/química , Sulfonas/química , Idoso , Biomarcadores/sangue , Feminino , Humanos , Nefropatias/sangue , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
17.
Artif Organs ; 45(10): 1195-1201, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33978975

RESUMO

The Clearum dialyzer, built by Medtronic, became commercially available in several European countries in 2020, but there are still no reports of in vivo data. The aim of this study was to evaluate the efficacy and risk of hypoalbuminemia of this dialyzer compared with previously evaluated hemodialysis (HD), expanded hemodialysis (HDx), and postdilution hemodiafiltration (HDF) treatments. A prospective study was carried out in 15 patients. Each patient underwent seven dialysis sessions: FX80 Cordiax in HD, Clearum HS17 in HD, Phylther 17-SD in HDx, Theranova 400 in HDx, Phylther 17-G in postdilution HDF, Clearum HS17 in postdilution HDF, and FX80 Cordiax in postdilution HDF. The reduction ratios of urea, creatinine, ß2 -microglobulin, myoglobin, prolactin, α1 -microglobulin, α1 -acid glycoprotein, and albumin were compared intraindividually. Dialysate albumin loss was also measured. Comparison of dialysis techniques revealed no differences between small molecules, but HDx and HDF were significantly higher than HD with medium and large molecular weights. The Clearum dialyzer in HDF obtained similar results to FX80 Cordiax in HDF, was slightly superior to Phylther 17-G in HDF, and was statistically superior to both dialyzers in HDx. Albumin losses with the Clearum dialyzer were among the lowest, both in HD and HDF treatments. The highest global removal score (GRS) values were obtained with the helixone and Clearum dialyzers in HDF, with similar results both in HD and HDF. In addition, the GRS values with HDx treatments were statistically significantly higher than those with HD. The new Clearum dialyzer has excellent behavior and tolerance in HD and HDF. Its adequate permeability has been proven with its maximal performance in HDF, which could represent an upgrade versus its predecessor polyphenylene dialyzers.


Assuntos
Hemodiafiltração/instrumentação , Falência Renal Crônica/terapia , Diálise Renal/instrumentação , Idoso , Idoso de 80 Anos ou mais , alfa-Globulinas/análise , Creatinina/sangue , Feminino , Hemodiafiltração/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Mioglobina/sangue , Orosomucoide/análise , Segurança do Paciente , Prolactina/sangue , Estudos Prospectivos , Diálise Renal/métodos , Resultado do Tratamento , Ureia/sangue , Microglobulina beta-2/sangue
18.
Blood Purif ; 50(6): 959-967, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33789265

RESUMO

BACKGROUND: By inhibiting the adsorption of protein and platelets, surface-modifying macromolecules (SMMs) may improve the hemocompatibility of hemodialyzers. This trial aims to assess the performance and safety of a novel dialyzer with a fluorinated polyurethane SMM, Endexo™. METHODS: This prospective, sequential, multicenter, open-label study (NCT03536663) was designed to meet regulatory requirements for clinical testing of new hemodialyzers, including assessment of the in vivo ultrafiltration coefficient (Kuf). Adults prescribed thrice-weekly hemodialysis were eligible for enrollment. After completing 12 hemodialysis sessions with an Optiflux® F160NR dialyzer, patients received 38 sessions with the dialyzer with Endexo. Evaluated parameters included the in vivo Kuf of the dialyzer with Endexo extent of removal of urea, albumin, and ß2-microglobulin (ß2M), as well as complement activation. RESULTS: Twenty-three patients received 268 hemodialysis treatments during the Optiflux period, and 18 patients received 664 hemodialysis treatments during the Endexo period. Three serious adverse events were reported, and none of them were considered device related. No overt complement activation was observed with either dialyzer. Both dialyzers were associated with comparable mean increases in serum albumin levels from pre- to posthemodialysis (Optiflux: 7.9%; Endexo: 8.0%). These increases can be viewed in the context of a mean increase in hemoglobin of approximately 5% and a mean ultrafiltration volume removed of approximately 2.2 L. The corrected mean ß2M removal rate was 47% higher during the Endexo period (67.73%). Mean treatment times (208 vs. 205 min), blood flow rates (447.7 vs. 447.5 mL/min), dialysate flow rates (698.5 vs. 698.0 mL/min), urea reduction ratio (82 vs. 81%), and spKt/V (2.1 vs. 1.9) were comparable for the Endexo and Optiflux periods, respectively. The mean (SD) Kuf was 15.85 (10.33) mL/h/mm Hg during the first use of the dialyzer with Endexo (primary endpoint) and 16.36 (9.92) mL/h/mm Hg across the Endexo period. CONCLUSIONS: The safety of the novel dialyzer with Endexo was generally comparable to the Optiflux dialyzer, while exhibiting a higher ß2M removal rate.


Assuntos
Materiais Biocompatíveis/química , Falência Renal Crônica/terapia , Poliuretanos/química , Diálise Renal/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Materiais Biocompatíveis/efeitos adversos , Feminino , Halogenação , Humanos , Falência Renal Crônica/sangue , Masculino , Membranas Artificiais , Pessoa de Meia-Idade , Poliuretanos/efeitos adversos , Estudos Prospectivos , Diálise Renal/efeitos adversos , Albumina Sérica/análise , Albumina Sérica/isolamento & purificação , Ureia/sangue , Ureia/isolamento & purificação , Microglobulina beta-2/sangue , Microglobulina beta-2/isolamento & purificação
19.
Crit Care ; 24(1): 644, 2020 11 11.
Artigo em Inglês | MEDLINE | ID: mdl-33176824

RESUMO

BACKGROUND: Myoglobin clearance in acute kidney injury requiring renal replacement therapy is important because myoglobin has direct renal toxic effects. Clinical data comparing different modalities of renal replacement therapy addressing myoglobin clearance are limited. This study aimed to compare two renal replacement modalities regarding myoglobin clearance. METHODS: In this prospective, randomized, single-blinded, single-center trial, 70 critically ill patients requiring renal replacement therapy were randomized 1:1 into an intervention arm using continuous veno-venous hemodialysis with high cutoff dialyzer and a control arm using continuous veno-venous hemodiafiltration postdilution with high-flux dialyzer. Regional citrate anticoagulation was used in both groups to maintain the extracorporeal circuit. The concentrations of myoglobin, urea, creatinine, ß2-microglobulin, interleukin-6 and albumin were measured before and after the dialyzer at 1 h, 6 h, 12 h, 24 h and 48 h after initiating continuous renal replacement therapy. RESULTS: Thirty-three patients were allocated to the control arm (CVVHDF with high-flux dialyzer) and 35 patients to the intervention arm (CVVHD with high cutoff dialyzer). Myoglobin clearance, as a primary endpoint, was significantly better in the intervention arm than in the control arm throughout the whole study period. The clearance values for urea and creatinine were higher in the control arm. There was no measurable albumin clearance in both arms. The clearance data for ß2-microglobulin and interleukin-6 were non-inferior in the intervention arm compared to those for the control arm. Dialyzer lifespan was 57.0 [38.0, 72.0] hours in the control arm and 70.0 [56.75, 72.0] hours in the intervention arm (p = 0.029). CONCLUSIONS: Myoglobin clearance using continuous veno-venous hemodialysis with high cutoff dialyzer and regional citrate anticoagulation is better than that with continuous veno-venous hemodiafiltration with regional citrate anticoagulation. TRIAL REGISTRATION: German Clinical Trials Registry (DRKS00012407); date of registration 23/05/2017. https://www.drks.de/drks_web/navigate.do?navigationId=trial.HTML&TRIAL_ID=DRKS00012407 .


Assuntos
Taxa de Depuração Metabólica/fisiologia , Mioglobina/metabolismo , Diálise Renal/métodos , Idoso , Creatinina/análise , Creatinina/sangue , Estado Terminal , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Mioglobina/sangue , Mioglobina/fisiologia , Estudos Prospectivos , Diálise Renal/estatística & dados numéricos , Ureia/análise , Ureia/sangue
20.
Artif Organs ; 44(7): 753-763, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31944338

RESUMO

Convection-based renal replacement therapies (RRTs) have the potential to improve patient outcomes when compared to diffusion-based RRT such as hemodialysis (HD), but have limited clearance rates. We propose and characterize multipoint dilution hemofiltration (MPD-HF), a purely convective blood purification technology which removes the fundamental filtration limit associated with convective RRT resulting in clearance rates on par with HD. In MPD-HF, filtration of liquid and solutes occurs along the length of the hollow fibers that convey the blood, and substitution fluid is pushed into the fibers at multiple points along their length. Since multiple filtration and dilution steps are contained within one pass of the blood through the hollow fiber, the fraction of fluid that can be filtered may be increased to allow a high clearance rate that removes a wide range of toxins. In vitro tests yielded an average steady-state filtrate fraction of 68%, exceeding commercial HDF cartridge filtrate fractions by a factor of approximately 3. The molecular weights of molecules cleared spans up to the cutoff of 66 kDa for albumin.


Assuntos
Soluções para Diálise/análise , Hemofiltração/métodos , Falência Renal Crônica/terapia , Modelos Cardiovasculares , Soluções para Diálise/química , Desenho de Equipamento , Análise de Elementos Finitos , Hemofiltração/instrumentação , Humanos , Falência Renal Crônica/sangue , Peso Molecular , Toxinas Biológicas/análise , Toxinas Biológicas/sangue , Toxinas Biológicas/química , Toxinas Biológicas/farmacocinética