Resultados 1 - 20 de 575
Filtrar
1.
Diabetologia ; 67(7): 1235-1244, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38634887

RESUMO

AIMS/HYPOTHESIS: This study compares the efficacy and safety of a tubeless, on-body automated insulin delivery (AID) system with that of a tubeless, on-body sensor-augmented pump (SAP). METHODS: This multicentre, parallel-group, RCT was conducted at 13 tertiary medical centres in South Korea. Adults aged 19-69 years with type 1 diabetes who had HbA1c levels of <85.8 mmol/mol (<10.0%) were eligible. The participants were assigned at a 1:1 ratio to receive a tubeless, on-body AID system (intervention group) or a tubeless, on-body SAP (control group) for 12 weeks. Stratified block randomisation was conducted by an independent statistician. Blinding was not possible due to the nature of the intervention. The primary outcome was the percentage of time in range (TIR), blood glucose between 3.9 and 10.0 mmol/l, as measured by continuous glucose monitoring. ANCOVAs were conducted with baseline values and study centres as covariates. RESULTS: A total of 104 participants underwent randomisation, with 53 in the intervention group and 51 in the control group. The mean (±SD) age of the participants was 40±11 years. The mean (±SD) TIR increased from 62.1±17.1% at baseline to 71.5±10.7% over the 12 week trial period in the intervention group and from 64.7±17.0% to 66.9±15.0% in the control group (difference between the adjusted means: 6.5% [95% CI 3.6%, 9.4%], p<0.001). Time below range, time above range, CV and mean glucose levels were also significantly better in the intervention group compared with the control group. HbA1c decreased from 50.9±9.9 mmol/mol (6.8±0.9%) at baseline to 45.9±7.4 mmol/mol (6.4±0.7%) after 12 weeks in the intervention group and from 48.7±9.1 mmol/mol (6.6±0.8%) to 45.7±7.5 mmol/mol (6.3±0.7%) in the control group (difference between the adjusted means: -0.7 mmol/mol [95% CI -2.0, 0.8 mmol/mol] (-0.1% [95% CI -0.2%, 0.1%]), p=0.366). No diabetic ketoacidosis or severe hypoglycaemia events occurred in either group. CONCLUSIONS/INTERPRETATION: The use of a tubeless, on-body AID system was safe and associated with superior glycaemic profiles, including TIR, time below range, time above range and CV, than the use of a tubeless, on-body SAP. TRIAL REGISTRATION: Clinical Research Information Service (CRIS) KCT0008398 FUNDING: The study was funded by a grant from the Korea Medical Device Development Fund supported by the Ministry of Science and ICT; the Ministry of Trade, Industry and Energy; the Ministry of Health and Welfare; and the Ministry of Food and Drug Safety (grant number: RS-2020-KD000056).


Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Hipoglicemiantes , Sistemas de Infusão de Insulina , Insulina , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/sangue , Masculino , Pessoa de Meia-Idade , Adulto , Feminino , Insulina/administração & dosagem , Insulina/uso terapêutico , Glicemia/efeitos dos fármacos , Glicemia/metabolismo , Glicemia/análise , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/uso terapêutico , Idoso , Hemoglobinas Glicadas/metabolismo , Hemoglobinas Glicadas/análise , República da Coreia , Automonitorização da Glicemia/métodos , Adulto Jovem
2.
Diabetologia ; 67(2): 236-245, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38041737

RESUMO

People living with diabetes have many medical devices available to assist with disease management. A critical aspect that must be considered is how systems for continuous glucose monitoring and insulin pumps communicate with each other and how the data generated by these devices can be downloaded, integrated, presented and used. Not only is interoperability associated with practical challenges, but also devices must adhere to all aspects of regulatory and legal frameworks. Key issues around interoperability in terms of data ownership, privacy and the limitations of interoperability include where the responsibility/liability for device and data interoperability lies and the need for standard data-sharing protocols to allow the seamless integration of data from different sources. There is a need for standardised protocols for the open and transparent handling of data and secure integration of data into electronic health records. Here, we discuss the current status of interoperability in medical devices and data used in diabetes therapy, as well as regulatory and legal issues surrounding both device and data interoperability, focusing on Europe (including the UK) and the USA. We also discuss a potential future landscape in which a clear and transparent framework for interoperability and data handling also fulfils the needs of people living with diabetes and healthcare professionals.


Assuntos
Automonitorização da Glicemia , Diabetes Mellitus , Humanos , Glicemia , Diabetes Mellitus/tratamento farmacológico , Registros Eletrônicos de Saúde , Reino Unido
3.
Diabetologia ; 67(10): 2045-2058, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39145882

RESUMO

Challenges and fears related to managing glucose levels around planned and spontaneous exercise affect outcomes and quality of life in people living with type 1 diabetes. Advances in technology, including continuous glucose monitoring, open-loop insulin pump therapy and hybrid closed-loop (HCL) systems for exercise management in type 1 diabetes, address some of these challenges. In this review, three research or clinical experts, each living with type 1 diabetes, leverage published literature and clinical and personal experiences to translate research findings into simplified, patient-centred strategies. With an understanding of limitations in insulin pharmacokinetics, variable intra-individual responses to aerobic and anaerobic exercise, and the features of the technologies, six steps are proposed to guide clinicians in efficiently communicating simplified actions more effectively to individuals with type 1 diabetes. Fundamentally, the six steps centre on two aspects. First, regardless of insulin therapy type, and especially needed for spontaneous exercise, we provide an estimate of glucose disposal into active muscle meant to be consumed as extra carbohydrates for exercise ('ExCarbs'; a common example is 0.5 g/kg body mass per hour for adults and 1.0 g/kg body mass per hour for youth). Second, for planned exercise using open-loop pump therapy or HCL systems, we additionally recommend pre-emptive basal insulin reduction or using HCL exercise modes initiated 90 min (1-2 h) before the start of exercise until the end of exercise. Modifications for aerobic- and anaerobic-type exercise are discussed. The burden of pre-emptive basal insulin reductions and consumption of ExCarbs are the limitations of HCL systems, which may be overcome by future innovations but are unquestionably required for currently available systems.


Assuntos
Diabetes Mellitus Tipo 1 , Exercício Físico , Sistemas de Infusão de Insulina , Insulina , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/terapia , Exercício Físico/fisiologia , Insulina/uso terapêutico , Glicemia/metabolismo , Hipoglicemiantes/uso terapêutico , Automonitorização da Glicemia/métodos , Qualidade de Vida
4.
Diabetologia ; 67(10): 2143-2153, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38995399

RESUMO

People with cystic fibrosis (CF) are at risk for dysglycaemia caused by progressive beta cell dysfunction and destruction due to pancreatic exocrine disease and fibrosis. CF-related diabetes (CFRD) is a unique form of diabetes that has distinctive features from both type 1 and type 2 diabetes. Recent advances in diabetes technology may be of particular benefit in this population given the complex, multi-system organ involvement and challenging health issues that people with CFRD often face. This review summarises how diabetes technologies, such as continuous glucose monitors (CGMs) and insulin delivery devices: (1) have improved our understanding of CFRD, including how hyperglycaemia affects clinical outcomes in people with CF; (2) may be helpful in the screening and diagnosis of CFRD; and (3) offer promise for improving the management of CFRD and easing the burden that this diagnosis can add to an already medically complicated patient population.


Assuntos
Fibrose Cística , Fibrose Cística/terapia , Humanos , Diabetes Mellitus , Sistemas de Infusão de Insulina , Automonitorização da Glicemia , Glicemia/metabolismo
5.
Diabetologia ; 67(10): 2075-2084, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38995398

RESUMO

Children with type 1 diabetes and their caregivers face numerous challenges navigating the unpredictability of this complex disease. Although the burden of managing diabetes remains significant, new technology has eased some of the load and allowed children with type 1 diabetes to achieve tighter glycaemic management without fear of excess hypoglycaemia. Continuous glucose monitor use alone improves outcomes and is considered standard of care for paediatric type 1 diabetes management. Similarly, automated insulin delivery (AID) systems have proven to be safe and effective for children as young as 2 years of age. AID use improves not only blood glucose levels but also quality of life for children with type 1 diabetes and their caregivers and should be strongly considered for all youth with type 1 diabetes if available and affordable. Here, we review key data on the use of diabetes technology in the paediatric population and discuss management issues unique to children and adolescents.


Assuntos
Automonitorização da Glicemia , Glicemia , Diabetes Mellitus Tipo 1 , Sistemas de Infusão de Insulina , Insulina , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/sangue , Criança , Glicemia/metabolismo , Adolescente , Insulina/uso terapêutico , Insulina/administração & dosagem , Qualidade de Vida , Hipoglicemiantes/uso terapêutico , Pré-Escolar
6.
Diabetologia ; 67(10): 2034-2044, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38740602

RESUMO

The role of automated insulin delivery systems in diabetes is expanding. Hybrid closed-loop systems are being used in routine clinical practice for treating people with type 1 diabetes. Encouragingly, real-world data reflects the performance and usability observed in clinical trials. We review the commercially available hybrid closed-loop systems, their distinctive features and the associated real-world data. We also consider emerging indications for closed-loop systems, including the treatment of type 2 diabetes where variability of day-to-day insulin requirements is high, and other challenging applications for this technology. We discuss issues around access and implementation of closed-loop technology, and consider the limitations of present closed-loop systems, as well as innovative approaches that are being evaluated to improve their performance.


Assuntos
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Sistemas de Infusão de Insulina , Insulina , Humanos , Insulina/administração & dosagem , Insulina/uso terapêutico , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 2/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/uso terapêutico , Glicemia/metabolismo , Glicemia/efeitos dos fármacos , Glicemia/análise
7.
Diabetologia ; 67(10): 2114-2128, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38953925

RESUMO

Suboptimal glycaemic management in hospitals has been associated with adverse clinical outcomes and increased financial costs to healthcare systems. Despite the availability of guidelines for inpatient glycaemic management, implementation remains challenging because of the increasing workload of clinical staff and rising prevalence of diabetes. The development of novel and innovative technologies that support the clinical workflow and address the unmet need for effective and safe inpatient diabetes care delivery is still needed. There is robust evidence that the use of diabetes technology such as continuous glucose monitoring and closed-loop insulin delivery can improve glycaemic management in outpatient settings; however, relatively little is known of its potential benefits and application in inpatient diabetes management. Emerging data from clinical studies show that diabetes technologies such as integrated clinical decision support systems can potentially mediate safer and more efficient inpatient diabetes care, while continuous glucose sensors and closed-loop systems show early promise in improving inpatient glycaemic management. This review aims to provide an overview of current evidence related to diabetes technology use in non-critical care adult inpatient settings. We highlight existing barriers that may hinder or delay implementation, as well as strategies and opportunities to facilitate the clinical readiness of inpatient diabetes technology in the future.


Assuntos
Diabetes Mellitus , Sistemas de Infusão de Insulina , Humanos , Diabetes Mellitus/terapia , Diabetes Mellitus/tratamento farmacológico , Pacientes Internados , Automonitorização da Glicemia , Glicemia/metabolismo , Hospitalização , Adulto , Insulina/uso terapêutico , Insulina/administração & dosagem , Controle Glicêmico/métodos , Hipoglicemiantes/uso terapêutico , Sistemas de Apoio a Decisões Clínicas
8.
Diabetologia ; 67(10): 2154-2159, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39028360

RESUMO

AIMS/HYPOTHESIS: This study aimed to describe the relationship between breastfeeding episodes and maternal glucose levels, and to assess whether this differs with closed-loop vs open-loop (sensor-augmented pump) insulin therapy. METHODS: Infant-feeding diaries were collected at 6 weeks, 12 weeks and 24 weeks postpartum in a trial of postpartum closed-loop use in 18 women with type 1 diabetes. Continuous glucose monitoring (CGM) data were used to identify maternal glucose patterns within the 3 h of breastfeeding episodes. Generalised mixed models adjusted for breastfeeding episodes in the same woman, repeat breastfeeding episodes, carbohydrate intake, infant age at time of feeding and early pregnancy HbA1c. This was a secondary analysis of data collected during a randomised trial (ClinicalTrials.gov registration no. NCT04420728). RESULTS: CGM glucose remained above 3.9 mmol/l in the 3 h post-breastfeeding for 93% (397/427) of breastfeeding episodes. There was an overall decrease in glucose at nighttime within 3 h of breastfeeding (1.1 mmol l-1 h-1 decrease on average; p=0.009). A decrease in nighttime glucose was observed with open-loop therapy (1.2 ± 0.5 mmol/l) but was blunted with closed-loop therapy (0.4 ± 0.3 mmol/l; p<0.01, open-loop vs closed-loop). CONCLUSIONS/INTERPRETATION: There is a small decrease in glucose after nighttime breastfeeding that usually does not result in maternal hypoglycaemia; this appears to be blunted with the use of closed-loop therapy.


Assuntos
Glicemia , Aleitamento Materno , Diabetes Mellitus Tipo 1 , Sistemas de Infusão de Insulina , Insulina , Período Pós-Parto , Humanos , Feminino , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/sangue , Glicemia/metabolismo , Glicemia/efeitos dos fármacos , Glicemia/análise , Adulto , Insulina/administração & dosagem , Insulina/uso terapêutico , Gravidez , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/uso terapêutico , Automonitorização da Glicemia , Controle Glicêmico/métodos , Hemoglobinas Glicadas/metabolismo , Hemoglobinas Glicadas/análise , Recém-Nascido , Lactente
9.
Diabetologia ; 67(10): 2059-2074, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38951212

RESUMO

The increasing incidence of type 2 diabetes, which represents 90% of diabetes cases globally, is a major public health concern. Improved glucose management reduces the risk of vascular complications and mortality; however, only a small proportion of the type 2 diabetes population have blood glucose levels within the recommended treatment targets. In recent years, diabetes technologies have revolutionised the care of people with type 1 diabetes, and it is becoming increasingly evident that people with type 2 diabetes can also benefit from these advances. In this review, we describe the current knowledge regarding the role of technologies for people living with type 2 diabetes and the evidence supporting their use in clinical practice. We conclude that continuous glucose monitoring systems deliver glycaemic benefits for individuals with type 2 diabetes, whether treated with insulin or non-insulin therapy; further data are required to evaluate the role of these systems in those with prediabetes (defined as impaired glucose tolerance and/or impaired fasting glucose and/or HbA1c levels between 39 mmol/mol [5.7%] and 47 mmol/mol [6.4%]). The use of insulin pumps seems to be safe and effective in people with type 2 diabetes, especially in those with an HbA1c significantly above target. Initial results from studies exploring the impact of closed-loop systems in type 2 diabetes are promising. We discuss directions for future research to fully understand the potential benefits of integrating evidence-based technology into care for people living with type 2 diabetes and prediabetes.


Assuntos
Glicemia , Diabetes Mellitus Tipo 2 , Estado Pré-Diabético , Humanos , Diabetes Mellitus Tipo 2/tratamento farmacológico , Estado Pré-Diabético/tratamento farmacológico , Glicemia/metabolismo , Glicemia/efeitos dos fármacos , Automonitorização da Glicemia , Sistemas de Infusão de Insulina , Insulina/uso terapêutico , Hipoglicemiantes/uso terapêutico , Hemoglobinas Glicadas/metabolismo
10.
Diabetologia ; 67(10): 2103-2113, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38967667

RESUMO

This review outlines some of the extraordinary recent advances in diabetes technology, which are transforming the management of type 1 diabetes before, during and after pregnancy. It highlights recent improvements associated with use of continuous glucose monitoring (CGM) but acknowledges that neither CGM nor insulin pump therapy are adequate for achieving the pregnancy glucose targets. Furthermore, even hybrid closed-loop (HCL) systems that are clinically effective outside of pregnancy may not confer additional benefits throughout pregnancy. To date, there is only one HCL system, the CamAPS FX, with a strong evidence base for use during pregnancy, suggesting that the pregnancy benefits are HCL system specific. This is in stark contrast to HCL system use outside of pregnancy, where benefits are HCL category specific. The CamAPS FX HCL system has a rapidly adaptive algorithm and lower glucose targets with benefits across all maternal glucose categories, meaning that it is applicable for all women with type 1 diabetes, before and during pregnancy. For women of reproductive years living with type 2 diabetes, the relative merits of using non-insulin pharmacotherapies vs diabetes technology (dipeptidyl peptidase-4 inhibitors, glucagon-like peptide-1 receptor agonists and sodium-glucose cotransporter 2 inhibitors) are unknown. Despite the urgent unmet need and potential benefits, studies of pharmacotherapy and technology use are extremely limited in pregnant women with type 2 diabetes.


Assuntos
Automonitorização da Glicemia , Diabetes Mellitus Tipo 1 , Sistemas de Infusão de Insulina , Gravidez em Diabéticas , Humanos , Gravidez , Feminino , Diabetes Mellitus Tipo 1/tratamento farmacológico , Automonitorização da Glicemia/métodos , Gravidez em Diabéticas/tratamento farmacológico , Gravidez em Diabéticas/sangue , Gravidez em Diabéticas/terapia , Hipoglicemiantes/uso terapêutico , Glicemia/metabolismo , Glicemia/efeitos dos fármacos , Diabetes Mellitus Tipo 2/tratamento farmacológico , Insulina/uso terapêutico
11.
Diabetes Metab Res Rev ; 40(6): e3842, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39298688

RESUMO

AIMS: To compare the efficacy and safety of different hybrid closed loop (HCL) systems in people with diabetes through a network meta-analysis. METHODS: We searched MEDLINE, EMBASE, CENTRAL and PubMed for randomised clinical trials (RCTs) enrolling children, adolescents and/or adults with type 1 or type 2 diabetes, evaluating Minimed 670G, Minimed 780G, Control-IQ, CamAPS Fx, DBLG-1, DBLHU, and Omnipod 5 HCL systems against other types of insulin therapy, and reporting time in target range (TIR) as outcome. RESULTS: A total of 28 RCTs, all enrolling people with type 1 diabetes, were included. HCL systems significantly increased TIR compared with subcutaneous insulin therapy without continuous glucose monitoring (SIT). Minimed 780G achieved the highest TIR ahead of Control IQ (mean difference (MD) 5.1%, 95% confidence interval (95% CI) [0.68; 9.52], low certainty), Minimed 670G (MD 7.48%, 95% CI [4.27; 10.7], moderate certainty), CamAPS Fx (MD 8.94%, 95% CI [4.35; 13.54], low certainty), and DBLG1 (MD 10.69%, 95% CI [5.73; 15.65], low certainty). All HCL systems decreased time below target range, with DBLG1 (MD -3.69%, 95% CI [-5.2; -2.19], high certainty), Minimed 670G (MD -2.9%, 95% CI [-3.77; -2.04], moderate certainty) and Minimed 780G (MD -2.79%, 95% CI [-3.94; -1.64], high certainty) exhibiting the largest reductions compared to SIT. The risk of severe hypoglycaemia and diabetic ketoacidosis was similar to other types of insulin therapy. CONCLUSIONS: We show a hierarchy of efficacy among the different HCL systems in people with type 1 diabetes, thus providing support to clinical decision-making. TRIAL REGISTRATION: PROSPERO CRD42023453717.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemiantes , Sistemas de Infusão de Insulina , Insulina , Humanos , Glicemia/análise , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/uso terapêutico , Insulina/administração & dosagem , Insulina/uso terapêutico , Metanálise em Rede , Prognóstico , Ensaios Clínicos Controlados Aleatórios como Assunto , Monitoramento Contínuo da Glicose/instrumentação , Monitoramento Contínuo da Glicose/métodos
12.
Diabet Med ; 41(2): e15262, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38017692

RESUMO

AIMS: Bespoke glycaemic control strategies following antenatal corticosteroids for women with diabetes in pregnancy (DIP) may mitigate hyperglycaemia. This study aims to identify predictive factors for the glycaemic response to betamethasone in a large cohort of women with DIP. METHODS: Evaluation of a prospective cohort study of 347 consecutive DIP pregnancies receiving two doses of 11.4 mg betamethasone 24 h apart between 2017 and 2021 and treated with the Pregnancy-IVI intravenous insulin protocol. Regression modelling identified factors associated with maternal glycaemic time-in-range (TIR) and maternal insulin requirements following betamethasone. Factors associated with neonatal hypoglycaemia (glucose <2.6 mmol/L) in infants born within 48 h of betamethasone administration (n = 144) were investigated. RESULTS: The mean maternal age was 31.9 ± 5.8 years, with gestational age at betamethasone of 33.5 ± 3.4 weeks. Gestational diabetes was present in 81% (12% type 1; 7% type 2). Pre-admission subcutaneous insulin was prescribed for 63%. On-infusion maternal glucose TIR (4.0-7.8 mmol/L) was 83% [IQR 77%-90%] and mean on-IVI glucose was 6.6 ± 0.5 mmol/L. Maternal hypoglycaemia (<3.8 mmol/L) was uncommon (0.47 h/100 on-IVI woman hours). Maternal glucose TIR was negatively associated with indicators of insulin resistance (type 2 diabetes, polycystic ovary syndrome), late-pregnancy complications (pre-eclampsia, chorioamnionitis) and the 1-h OGTT result. Intravenous insulin requirements were associated with type of diabetes, pre-eclampsia and intrauterine infection, the 1-h OGTT result and the timing of betamethasone administration. Neonatal hypoglycaemia was associated with pre-existing diabetes but not with measures of glycaemic control. CONCLUSION: An intravenous infusion protocol effectively controls maternal glucose after betamethasone. A risk-factor-based approach may allow individualisation of therapy.


Assuntos
Diabetes Mellitus Tipo 2 , Diabetes Gestacional , Doenças Fetais , Hiperglicemia , Hipoglicemia , Pré-Eclâmpsia , Gravidez em Diabéticas , Recém-Nascido , Gravidez , Feminino , Humanos , Adulto , Lactente , Diabetes Gestacional/tratamento farmacológico , Diabetes Gestacional/epidemiologia , Diabetes Mellitus Tipo 2/tratamento farmacológico , Betametasona/uso terapêutico , Hiperglicemia/prevenção & controle , Estudos Prospectivos , Hipoglicemia/induzido quimicamente , Hipoglicemia/epidemiologia , Hipoglicemia/prevenção & controle , Gravidez em Diabéticas/tratamento farmacológico , Parto , Insulina/efeitos adversos , Glucose
13.
Diabet Med ; 41(11): e15432, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-39239975

RESUMO

AIMS: The present analysis estimated the cost-effectiveness of treatment with the Tandem t: slim X2 insulin pump with Control IQ technology (CIQ) in children with type 1 diabetes in Sweden. METHODS: A four-state Markov model and probabilistic sensitivity analyses (PSA) were used to assess the cost-effectiveness of CIQ use compared with treatment with multiple daily insulin injections (MDI) or continuous subcutaneous insulin infusion (CSII) in conjunction with CGM. Data sources included clinical input data from a recent retrospective, observational study, cost data from local diabetes supply companies and government agencies, and published literature. Outcomes measures were quality adjusted life years (QALYs) at 10, 20 and 30-year time horizons based on cost per QALY and incremental cost-effectiveness ratio (ICER). RESULTS: A total of 84 type 1 diabetes children were included (CIQ, n = 37; MDI, n = 19; CSII, n = 28). For all time horizons, the use of CIQ was a dominant strategy (e.g. more effective and less costly) compared with MDI or CSII use: 10-year ICER, SEK -88,010.37 and SEK -91,723.92; 20-year ICER, SEK -72,095.33 and SEK -87,707.79; and 30-year ICER, SEK -65,573.01 and SEK -85,495.68, respectively. PSA confirmed that CIQ use was less costly compared with MDI and CSII. CONCLUSIONS: Initiation of CIQ use in children with type 1 diabetes is cost-saving, besides previously shown improved glycaemic control, and increased quality of life. Further investigations are needed to more fully elucidate the cost-effectiveness of these technologies in different countries with existing differences in payment models.


Assuntos
Análise Custo-Benefício , Diabetes Mellitus Tipo 1 , Hipoglicemiantes , Sistemas de Infusão de Insulina , Insulina , Anos de Vida Ajustados por Qualidade de Vida , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/economia , Diabetes Mellitus Tipo 1/sangue , Sistemas de Infusão de Insulina/economia , Criança , Adolescente , Suécia , Insulina/administração & dosagem , Insulina/economia , Insulina/uso terapêutico , Feminino , Masculino , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/economia , Hipoglicemiantes/uso terapêutico , Cadeias de Markov , Estudos Retrospectivos , Automonitorização da Glicemia/economia , Pré-Escolar
14.
Diabet Med ; : e15449, 2024 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-39377427

RESUMO

AIM: To understand experiences of using second-generation advanced hybrid closed-loop (AHCL) therapy in adolescents and young adults with chronically elevated glucose levels who were previously using multiple daily injections (MDI) therapy. METHOD: Semi-structured interviews with participants aged 13-25 years, on AHCL therapy for 3 months as part of a single-arm prospective study. Key inclusions: HbA1c ≥69 mmol/mol (8.5%); diabetes duration ≥1 year; and using MDI therapy prior to the study. Qualitative content analysis was used to identify themes and subthemes. RESULTS: Interviews were conducted among 14 participants with mean age 19.4 ± 4.3 years and mean baseline HbA1c 90 ± 25 mmol/mol (10.4 ± 4.5%). Three themes were identified: (1) substantially improved glucose levels improved perceptions of overall health; (2) features of AHCL aid in adoption and ongoing self-management; and (3) burden of care was reduced through automation of insulin delivery. Overall, there were positive impacts on physical, mental and social well-being. Participants were willing to overlook minor frustrations with AHCL because of the vast benefits that they had experienced. Four participants reported transient pseudo-hypoglycaemia: symptoms of hypoglycaemia when objectively measured glucose was in the clinically recommended range (3.9-10 mmol/L, 70-180 mg/dL). CONCLUSION: Transition to AHCL therapy positively impacted diabetes management in adolescents and youth with chronically elevated glucose levels. It appears to create a window of opportunity in which youth may re-engage with diabetes management. Pseudo-hypoglycaemia can occur during the transition to AHCL. This could be a barrier to AHCL uptake and is likely to require individualised support.

15.
Diabet Med ; 41(4): e15264, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38073128

RESUMO

AIMS: First-generation closed-loop automated insulin delivery improves glycaemia and psychosocial outcomes among older adults with type 1 diabetes in clinical trials. However, no study has previously assessed real-world lived experience of older adults using closed-loop therapy outside a trial environment. METHODS: Semi-structured interviews were conducted with older adults who were pre-existing insulin pump users and previously completed the OldeR Adult Closed-Loop (ORACL) randomised trial. Interviews focused on perceptions of diabetes technology use, and factors influencing decisions regarding continuation. RESULTS: Twenty-eight participants, mean age 70 years (SD 5), were interviewed at median 650 days (IQR 608-694) after their final ORACL trial visit. At interview, 23 participants (82%) were still using a commercial closed-loop system (requiring manual input for prandial insulin bolus doses). Themes discussed in interviews relating to closed-loop system use included sustained psychosocial benefits, cost and retirement considerations and usability frustrations relating to sensor accuracy and system alarms. Of the five participants who had discontinued, reasons included cost, continuous glucose monitoring-associated difficulties and usability frustrations. Cost was the largest consideration regarding continued use; most participants considered the increased ease of diabetes management to be worth the associated costs, though cost was prohibitive for some. CONCLUSIONS: Almost 2 years after completing a closed-loop clinical trial, closed-loop automated insulin delivery remains the preferred type 1 diabetes therapy for the majority of older adult participants. Chronological age is not a barrier to real-world successful use of diabetes technology. Identifying age-related barriers, and solutions, to diabetes technology use among older adults is warranted.


Assuntos
Diabetes Mellitus Tipo 1 , Insulina , Humanos , Idoso , Insulina/uso terapêutico , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/psicologia , Hipoglicemiantes/uso terapêutico , Automonitorização da Glicemia , Glicemia , Resultado do Tratamento , Sistemas de Infusão de Insulina , Estudos Cross-Over
16.
Diabet Med ; 41(4): e15246, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37873612

RESUMO

The recent clearance by the United States Food and Drug Administration of Tidepool Loop sets an important precedent within the medical device landscape. For the first time, an automated insulin delivery mobile application-based on an algorithm initially designed and developed by users -has been recognised as safe and effective by a regulatory body. The aim of this paper is twofold: firstly, we map out the regulatory pathways and processes that were navigated by Tidepool, the non-profit behind Tidepool Loop, in order to make this landmark moment possible. Secondly, we set out potential approvals processes in the European Union and United Kingdom with a view to examining the challenges to obtaining regulatory clearance for Tidepool Loop in these jurisdictions. In so doing, we highlight the significant differences, not only between the United States and European systems but also between the European Union and Great Britain systems. We conclude by arguing that the complexity encountered when seeking to introduce an innovative solution in different regulatory systems has the potential to act as a disincentive to open source developers from seeking regulatory approvals for such technologies in the future.


Assuntos
Insulina , Estados Unidos , Humanos , União Europeia , Reino Unido , Insulina/uso terapêutico , United States Food and Drug Administration
17.
Curr Diab Rep ; 24(8): 173-182, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38842632

RESUMO

PURPOSE OF REVIEW: There have been many developments in diabetes technology in recent years, with continuous glucose monitoring (CGM), insulin pump therapy (CSII) and automated insulin delivery (AID) becoming progressively accepted in outpatient diabetes care. However, the use of such advanced diabetes technology in the inpatient setting is still limited for several reasons, including logistical challenges and staff training needs. On the other hand, hospital settings with altered diet and stress-induced hyperglycemia often pose challenges to tight glycemic control using conventional treatment tools. Integrating smarter glucose monitoring and insulin delivery devices into the increasingly technical hospital environment could reduce diabetes-related morbidity and mortality. This narrative review describes the most recent literature on the use of diabetes technology in the hospital and suggests avenues for further research. RECENT FINDINGS: Advanced diabetes technology has the potential to improve glycemic control in hospitalized people with and without diabetes, and could add particular value in certain conditions, such as nutrition therapy or perioperative management. Taken together, CGM allows for more accurate and patient-friendly follow-up and ad hoc titration of therapy. AID may also provide benefits, including improved glycemic control and reduced nursing workload. Before advanced diabetes technology can be used on a large scale in the hospital, further research is needed on efficacy, accuracy and safety, while implementation factors such as cost and staff training must also be overcome.


Assuntos
Automonitorização da Glicemia , Diabetes Mellitus , Sistemas de Infusão de Insulina , Humanos , Diabetes Mellitus/terapia , Insulina/uso terapêutico , Insulina/administração & dosagem , Hospitais , Hipoglicemiantes/uso terapêutico , Glicemia/análise , Glicemia/metabolismo , Controle Glicêmico/métodos
18.
Curr Diab Rep ; 24(4): 61-73, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38294726

RESUMO

PURPOSE OF REVIEW: Maintaining positive health behaviours promotes better health outcomes for people with type 1 diabetes (T1D). However, implementing these behaviours may also lead to additional management burdens and challenges. Diabetes technologies, including continuous glucose monitoring systems, automated insulin delivery systems, and digital platforms, are being rapidly developed and widely used to reduce these burdens. Our aim was to review recent evidence to explore the influence of these technologies on health behaviours and well-being among adults with T1D and discuss future directions. RECENT FINDINGS: Current evidence, albeit limited, suggests that technologies applied in diabetes self-management education and support (DSME/S), nutrition, physical activity (PA), and psychosocial care areas improved glucose outcomes. They may also increase flexibility in insulin adjustment and eating behaviours, reduce carb counting burden, increase confidence in PA, and reduce mental burden. Technologies have the potential to promote health behaviours changes and well-being for people with T1D. More confirmative studies on their effectiveness and safety are needed to ensure optimal integration in standard care practices.


Assuntos
Diabetes Mellitus Tipo 1 , Adulto , Humanos , Diabetes Mellitus Tipo 1/terapia , Diabetes Mellitus Tipo 1/psicologia , Automonitorização da Glicemia , Promoção da Saúde , Glicemia , Insulina , Comportamentos Relacionados com a Saúde , Tecnologia
19.
Diabetes Obes Metab ; 26(2): 622-630, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37921083

RESUMO

AIM: The study aim was to evaluate the feasibility, safety and efficacy of automated insulin delivery (AID) assisted by home health care (HHC) services in people with type 2 diabetes unable to manage multiple daily insulin injections (MDI) at home on their own. PATIENTS AND METHODS: This was an open label, multicentre, randomized, parallel group trial. In total, 30 adults with type 2 diabetes using MDI and requiring nursing support were randomly allocated to AID or kept their usual therapy over a 12-week period. Both treatments were managed with the support of HHC services. The primary outcome was the percentage time in the target glucose range of 70-180 mg/dl (TIR). Secondary outcomes included other continuous glucose monitoring metrics, glycated haemoglobin (HbA1c) levels, daily insulin doses, body weight, and of quality of life scores, fear of hypoglycaemia and satisfaction questionnaires. RESULTS: Age (69.7 vs. 69.3 years) and HbA1c (9.25 vs. 9.0) did not differ in MDI and AID at baseline. Compared with MDI, AID resulted in a significant increase in TIR by 27.4% [95% CI (15.0-39.8); p < .001], a decrease in time above range by 27.7% and an unchanged time below range of <1%. A between-group difference in HbA1c was 1.3% favouring AID. Neither severe hypoglycaemia nor ketoacidosis occurred in either group. Patient and caregiver satisfaction with AID was high. CONCLUSIONS: AID combined with tailored HHC services significantly improved glycaemic control with no safety issues in people with type 2 diabetes previously under an MDI regimen with HHC. AID should be considered a safe option in these people when lacking acceptable glucose control.


Assuntos
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Serviços de Assistência Domiciliar , Hipoglicemia , Adulto , Humanos , Insulina/efeitos adversos , Hipoglicemiantes/uso terapêutico , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 2/tratamento farmacológico , Hemoglobinas Glicadas , Automonitorização da Glicemia , Qualidade de Vida , Glicemia , Resultado do Tratamento , Sistemas de Infusão de Insulina , Hipoglicemia/induzido quimicamente , Hipoglicemia/prevenção & controle , Hipoglicemia/tratamento farmacológico , Insulina Regular Humana/uso terapêutico
20.
Diabetes Obes Metab ; 26(2): 557-566, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37905353

RESUMO

AIM: To investigate glycaemic outcomes in youths and adults with type 1 diabetes with either MiniMed™ 780G or Tandem t:slim X2™ control-IQ automated insulin delivery (AID) systems and to evaluate clinical factors that migrate, mitigate the achievement of therapeutic goals. MATERIALS AND METHODS: This retrospective, real-world, observational study was conducted in a specialized university type 1 diabetes centre with patients observed for 3-12 months post-initiation of an AID system. Primary outcomes were the percentage time in the target glucose range [TIR70-180 mg/dl (3.9-10 mmol/L)] as measured by continuous glucose monitoring, mean glucose management indicator (GMI) and glycated haemoglobin (HbA1c) levels. RESULTS: Our study cohort consisted of 48 adolescents and 183 adults (55% females) aged 10-77 years. The mean (95% confidence interval) TIR70-180 mg/dl after 30 days was higher than baseline and by 14% points after 360 days with 71.33% (69.4-73.2) (n = 123, p < .001). HbA1c levels decreased by 0.7% and GMI by 0.6% after 360 days. The proportion of time spent <70 mg/dl (3.9 mmol/L) was not significantly different from baseline. During follow-up, 780G users had better continuous glucose monitoring results than control-IQ users but similar HbA1c levels, and an increased risk of weight gain. Age at onset influenced TIR70-180 mg/dl in univariate analysis but there was no significant relationship after adjusting on explanatory variables. Baseline body mass index did not influence the performance of AID systems. CONCLUSIONS: This analysis showed the beneficial effects of two AID systems for people with type 1 diabetes across a broad spectrum of participant characteristics. Only half of the participants achieved international recommendations for glucose control with TIR70-180 mg/dl >70%, HbA1c levels or GMI <7%, which outlines the need to maintain strong educational and individual strategies.


Assuntos
Diabetes Mellitus Tipo 1 , Insulina , Adulto , Feminino , Humanos , Adolescente , Masculino , Insulina/uso terapêutico , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Hemoglobinas Glicadas , Automonitorização da Glicemia/métodos , Estudos Retrospectivos , Seguimentos , Glicemia/análise , Insulina Regular Humana/uso terapêutico , Glucose/uso terapêutico , Sistemas de Infusão de Insulina