Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 246
Filtrar
1.
World J Urol ; 42(1): 96, 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38386126

RESUMO

The introduction of the Ho:YAG laser 3 decades ago revolutionized the endoscopic treatment of urolithiasis. Since then, a variety of innovations have continued to evolve these devices, including the development of high-power lasers capable of high-frequency lithotripsy. The clinical utility of high-frequency lithotripsy, however, has not necessarily lived up to the potential suggested by in vitro studies. A review of the relevant literature, confirming strong similarities between the outcomes associated with high and lower power laser lithotripsy, follows.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Litotripsia , Urolitíase , Humanos , Lasers de Estado Sólido/uso terapêutico , Projetos de Pesquisa , Urolitíase/cirurgia
2.
World J Urol ; 42(1): 62, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-38285266

RESUMO

PURPOSE: To evaluate the cooling effect and other advantages of a novel circulation system for ureteroscopic holmium laser lithotripsy (URSL) in a standardized in vitro model. MATERIALS AND METHODS: The novel circulation system was assembled by connecting a 4Fr ureteral catheter and a filter. Trails were divided into a new URSL group and a conventional URSL group. First, different power settings (18-30 W) of the holmium laser and irrigation flow rates (20-50 mL/min) were used to evaluate the thermal effect on the lithotripsy site of all groups. Then, renal pelvic temperature and pressure were assessed during URSL at a power of 1.5 J/20 Hz and irrigation flow rates of (20-50 mL/min). Finally, the whole process of lithotripsy was performed at 1.5 J/20 Hz (operator duty cycle ODC: 50%) with an irrigation flow rate of 30 mL/min. The time required for lithotripsy, visual field clarity, and stone migration were observed. RESULTS: Temperature of the lithotripsy point was significantly lower in the new URSL group than in the conventional group (P < 0.05) with irrigation rates (20, 30 mL/min). The renal pelvic pressure of the new group was significantly lower than that of the conventional group in which intrarenal hypertension developed at an irrigation rate of 50 ml/min. The new group had better visual clarity and lesser stone upward migration when lithotripsy was performed at 1.5 J/20 Hz and 30 ml/min. CONCLUSION: The novel circulation system is more effective in reducing the thermal effects of URSL, pelvic pressure, stone upward migration, and improving the visual clarity of the operative field.


Assuntos
Hipertensão , Litotripsia a Laser , Litotripsia , Humanos , Ureteroscopia , Hólmio
3.
World J Urol ; 42(1): 145, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38478094

RESUMO

INTRODUCTION AND OBJECTIVES: Medical device companies have introduced new TFL machines, including Soltive (Olympus, Japan), Fiber Dust (Quanta System, Italy), and TFLDrive (Coloplast, France). The primary objective of this study is to compare our initial clinical experiences with TFL using those devices. Through this historical comparison of Thulium Fiber Laser systems for stone lithotripsy, we aim to advance our understanding and approach toward achieving safe and effective TFL parameters. MATERIALS AND METHODS: The data for this comparative analysis were extracted from three distinct prospective series that were previously published, outlining our initial clinical experience with the Soltive (Olympus, Japan), FiberDust laser (Quanta System, Italy), and TFLDrive laser (Coloplast, France). Parameters such as stone size, stone density, laser-on time (LOT), and laser settings were meticulously recorded. Additionally, we assessed critical variables such as ablation speed (expressed in mm3/s) and Joules/mm3 for each lithotripsy procedure. RESULTS: A total of 149 patients were enrolled in this study. Among them, 120 patients were subjected to analysis concerning renal stones. Statistically significant differences were observed in the median (IQR) stone volume: 650 (127-6027) mm3 for TFLDrive, 1800 (682.8-2760) mm3 for Soltive, and 1125 (294-4000) mm3 for FiberDust (p: 0.007); while there were no differences regarding stone density among the groups. Significant variations were identified in median (IQR) pulse energy, frequency, and total power. The Soltive group exhibited lower energy levels (0.3 J vs. 0.6 J, p: 0.002) but significantly higher pulse frequency (100 Hz vs. 17.5 Hz, p: 0.003) and total power (24 W vs. 11W, p: 0.001) compared to the other groups. Laser-on time showed no substantial differences across all three groups. Additionally, a statistically significant difference was observed in median J/mm3, with the TFLDrive group using higher values (24 J/mm3, p: 0.001), while the Soltive group demonstrated a higher median ablation speed of 1.16 mm3/s (p: 0.001). The overall complication rate remained low for all groups, with comparable stone-free rates. CONCLUSION: By reducing pulsed frequency, we improved laser efficiency, but smaller volumes lead to decreased efficiency due to increased retropulsion and fragment movement. Further studies are needed to identify and establish the appropriate laser settings for this new technology.


Assuntos
Cálculos Renais , Lasers de Estado Sólido , Litotripsia a Laser , Litotripsia , Humanos , Túlio/uso terapêutico , Litotripsia a Laser/métodos , Cálculos Renais/cirurgia
4.
World J Urol ; 42(1): 157, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38483596

RESUMO

PURPOSE: To evaluate the thermal profiles of the holmium laser at different laser parameters at different locations in an in vitro anatomic pelvicalyceal collecting system (PCS) model. Laser lithotripsy is the cornerstone of treatment for urolithiasis. With the prevalence of high-powered lasers, stone ablation efficiency has become more pronounced. Patient safety remains paramount during surgery. It is well recognized that the heat generated from laser lithotripsy has the potential to cause thermal tissue damage. METHODS: Utilizing high-fidelity, 3D printed hydrogel models of a PCS with a synthetic BegoStone implanted in the renal pelvis, laser lithotripsy was performed with the Moses 2.0 holmium laser. At a standard power (40 W) and irrigation pressure (100 cm H2O), we evaluated operator duty cycle (ODC) variations with different time-on intervals at four different laser settings. Temperature was measured at two separate locations-at the stone and away from the stone. RESULTS: Temperatures were highest closest to the laser tip with a decrease away from the laser. Fluid temperatures increased with longer laser-on times and higher ODCs. Thermal doses were greater with increased ODCs and the threshold for thermal injury was reached for ODCs of 75% and 100%. CONCLUSION: Temperature generation and thermal dose delivered are greatest closer to the tip of the laser fiber and are not dependent on power alone. Significant temperature differences were noted between four laser settings at a standardized power (40 W). Temperatures can be influenced by a variety of factors, such as laser-on time, operator duty cycle, and location in the PCS.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Litotripsia , Humanos , Hólmio , Lasers de Estado Sólido/uso terapêutico , Modelos Anatômicos
5.
World J Urol ; 42(1): 447, 2024 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-39066919

RESUMO

PURPOSE: It is critical to provide patients with accurate information on potential surgical outcomes during the preoperative phase. Several scoring systems have been developed for this specific purpose. This study aimed to examine the predicted efficacy of scoring systems in patients with isolated lower calyx stones who underwent retrograde intrarenal surgery (RIRS). METHODS: We performed a retrospective analysis of 85 patients who underwent RIRS for lower calyx stones between 2016 and 2023. The study computed each participant's Resorlu-Unsal Stone score (RUSS), R.I.R.S. scoring system score, Modified Seoul National University Renal Stone Complexity (S-ReSC) score, S.T.O.N.E. score, Ito's nomogram, and T.O.HO score. Residual stones less than 4 mm were classified as clinically insignificant residual fragments (CIRFs) and regarded as successful. Following that, we used receiver-operating characteristic (ROC) curves to compare various scoring systems' success predictions. RESULTS: The median scores for RUSS, R.I.R.S. scoring system, Modified S-ReSC, S.T.O.N.E., Ito's nomogram, and T.O.HO score were 1 (1), 7 (2), 2 (0), 11 (1), 18 (4), and 7 (1), respectively. When CIRF cases were included, the stone-free rate increased to 80%. Only Ito's nomogram from scoring systems has a statistically significant cut-off value for success in ROC analysis (p = 0.021). In multivariate analysis, stone volume and preoperative hydronephrosis were associated with success (p = 0.004 and p = 0.035, respectively). CONCLUSION: In the multivariate analysis, none of the scoring systems were significantly associated with success. Hence, a new scoring system must be developed exclusively for patients with isolated lower pole stones undergoing RIRS.


Assuntos
Cálculos Renais , Cálices Renais , Humanos , Cálculos Renais/cirurgia , Estudos Retrospectivos , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Cálices Renais/cirurgia , Resultado do Tratamento , Procedimentos Cirúrgicos Urológicos/métodos , Nomogramas , Idoso
6.
World J Urol ; 42(1): 143, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38478076

RESUMO

PURPOSE: To present the initial prospective clinical assessment of the ILY® robotic ureteroscopy manipulator platform, focusing on its safety and effectiveness. METHODS AND MATERIALS: Data gathered from 31 kidney units which underwent elective robotic flexible ureteroscopy (FURS) for renal stone management utilizing the ILY® robotic system. Patient demographics, stone characteristics, surgical durations, perioperative and post-operative complications, and follow-up parameters were collected. Our primary outcome was evaluating the efficacy and safety of the ILY® robotic ureteroscopy for treating kidney stones. Therefore, we analyzed complication rates, surgical durations, and the stone-free rate during follow-up. RESULTS: Our cohort consisted of 29 patients, presenting with 45 stones with a median volume of 736.22 mm3. The median operation time was 85 min, accompanied by 3 min for robot draping, 3.5 min for robot docking, 48 min of console operation, and lasing time of 36.75 min. Post operative stay for all patients was 1 day, while complications were observed in 9.68% of cases. Notably, all complications were classified as CVD (Clavien-Dindo) class 1 due to pain requiring emergency department visit. The stone-free rate achieved was 93.55%, and none of the patient required reoperation for the treated stone. CONCLUSION: In the first prospective clinical experience of the ILY® robotic FURS, we demonstrated its efficacy and safety. To further investigate its clinical practical value, additional investigations are warranted, including direct comparative analyses with manual flexible ureteroscopy techniques.


Assuntos
Cálculos Renais , Litotripsia a Laser , Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Ureteroscopia/métodos , Estudos Prospectivos , Litotripsia a Laser/métodos , Resultado do Tratamento , Cálculos Renais/terapia , Estudos Retrospectivos
7.
World J Urol ; 42(1): 323, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38748255

RESUMO

PURPOSE: This study aimed to assess the effect of the modified 5-item frailty index on perioperative complications and surgical outcomes in patients who underwent ureteroscopy with laser lithotripsy for upper urinary tract stones. METHODS: Patients who underwent ureteroscopy with laser lithotripsy for upper urinary tract stones between 2019 and 2022 were reviewed retrospectively. Assessment was performed using the modified 5-item frailty index based on medical history (hypertension, diabetes, heart failure, chronic obstructive pulmonary disease) and functional status. Patients were categorized into the high (≥ 2) and low (≤ 1) modified 5-item frailty index groups based on the frailty score. We compared the perioperative complications and surgical outcomes between the two groups. RESULTS: Seventy-one (15.8%) and 393 (84.1%) of the 467 patients were classified into the high and low modified 5-item frailty index groups, respectively. The high modified 5-item frailty index group exhibited a significant association with increased febrile urinary tract infections compared to the low modified 5-item frailty index group [≥ 37.8 °C: 15 (20.3%) vs 13 (3.3%), p < 0.001; ≥ 38 °C: 9 (12.2%) vs 7 (1.8%), p < 0.001]. Surgical outcomes, including operative time and stone-free rate, did not differ significantly between the two groups. CONCLUSION: The modified 5-item frailty index is valuable for predicting postoperative complications, particularly febrile urinary tract infections, after ureteroscopy with laser lithotripsy for upper urinary tract stones. This index allows for practical preoperative risk assessment in patients who underwent ureteroscopy with laser lithotripsy.


Assuntos
Febre , Fragilidade , Cálculos Renais , Litotripsia a Laser , Complicações Pós-Operatórias , Cálculos Ureterais , Ureteroscopia , Infecções Urinárias , Humanos , Feminino , Masculino , Estudos Retrospectivos , Pessoa de Meia-Idade , Litotripsia a Laser/métodos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/diagnóstico , Infecções Urinárias/etiologia , Infecções Urinárias/epidemiologia , Idoso , Fragilidade/diagnóstico , Febre/etiologia , Cálculos Renais/cirurgia , Cálculos Ureterais/cirurgia , Valor Preditivo dos Testes , Adulto
8.
BMC Urol ; 24(1): 54, 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38454412

RESUMO

BACKGROUND: For renal stones > 20 mm, percutaneous nephrolithotomy (PNL) offers the best stone clearance rates with acceptable complication rates. This study aimed to compare the efficiency of high-power holmium YAG laser and ballistic lithotripsy during mini-PNL. METHODS: Data from 880 patients who underwent mini-PNL for renal stones was investigated retrospectively. The study utilized propensity score matching to create two groups: laser lithotripsy (n = 440) and ballistic lithotripsy (n = 440). The groups were matched based on stone size, Guy's stone score, and stone density. The main objectives of the study were to assess the stone-free rate (SFR), duration of surgery, and complication rates. RESULTS: The average age of the population was 51.4 ± 7.1 years, with a mean stone size of 28.6 ± 8.3 mm and a mean stone density of 1205 ± 159 HU. There were no significant differences between the groups. The SFRs of the laser lithotripsy and ballistic lithotripsy were 92.5% and 90.2%, respectively (p = 0.23). The laser lithotripsy group had a notably shorter surgery time (40.1 ± 6.3 min) compared to the ballistic lithotripsy group (55.6 ± 9.9 min) (p = 0.03). Complication rates were similar (p = 0.67). CONCLUSIONS: Our study shows that a high-power holmium YAG laser provides quicker operation time compared to ballistic lithotripsy. However, ballistic lithotripsy is still an effective and safe option for stone fragmentation during mini-PNL. In places where a high-power holmium YAG laser is not available, ballistic lithotripters are still a safe, effective, and affordable option for mini-PNL.


Assuntos
Cálculos Renais , Lasers de Estado Sólido , Litotripsia a Laser , Litotripsia , Nefrolitotomia Percutânea , Humanos , Adulto , Pessoa de Meia-Idade , Nefrolitotomia Percutânea/métodos , Estudos Retrospectivos , Resultado do Tratamento , Cálculos Renais/cirurgia , Litotripsia/métodos , Lasers de Estado Sólido/uso terapêutico
9.
BMC Ophthalmol ; 24(1): 214, 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38760776

RESUMO

BACKGROUND: Endogenous endophthalmitis (EE) is a rare but highly destructive eye emergency secondary to systemic infection. Acute endophthalmitis can lead to irreversible vision impairment or even loss of the whole eye, unless being diagnosed and treated promptly. CASE PRESENTATION: This study reports three typical EE cases of endogenous endophthalmitis secondary to different severe systemic diseases. Patients were recruited from the Department of ophthalmology at Zhongnan hospital of Wuhan University and the Department of ophthalmology at the Second Affiliated Hospital of Fujian Medical University. Patients were followed up for up to 60 days. Among these cases, the eye symptoms is the initial manifestations while secondary to original different special systemic conditions. Patients have been treated under dynamically prompt response undergoing systemic treatment and eye treatment at the same time. Best corrected visual acuity were 20/40, 20/60 and light perception during follow-up evaluation. CONCLUSIONS: Our observation suggest that prompt identification and treatment could save patients' vision from EE.


Assuntos
Endoftalmite , Infecções Oculares Bacterianas , Acuidade Visual , Humanos , Antibacterianos/uso terapêutico , Endoftalmite/diagnóstico , Endoftalmite/microbiologia , Infecções Oculares Bacterianas/microbiologia , Infecções Oculares Bacterianas/diagnóstico , Infecções Oculares Bacterianas/tratamento farmacológico , Acuidade Visual/fisiologia
10.
Lasers Surg Med ; 56(2): 197-205, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38037268

RESUMO

BACKGROUND AND OBJECTIVES: Compared to the conventional Ho: YAG laser, a Ho: YAG laser device has been reported that has a Moses effect to reduce stone retropulsion and increase lithotripsy efficiency. The principle of this equipment is to convert a single laser pulse into two pulses. Most studies on such lasers are limited to lithotripsy efficiency and the prevention of stone retropulsion; studies according to each pulse condition have not been performed. Therefore, the purpose of this study was to quantify the bubble shape, lithotripsy efficiency, and stone retropulsion displacement in a ureteral phantom according to the modulation of the first pulse characteristics of the Moses effect laser under conditions that maintained the total energy and repetition rate. MATERIAL AND METHODS: In this study, a Ho: YAG laser system (Holinwon Pro, Wontech Inc., Korea) with an emission wavelength of 2.10 µm and a Moses effect was used. To verify the Moses effect based on the changes in the pulse, a water tank was fabricated, and the ureteral phantom was manufactured in a structure that could be easily installed in the water tank. Additionally, a spherical artificial stone in the ureteral phantom was prepared by mixing calcined gypsum (Cacinated Gypsum) and water at a ratio of 3:1. In the ureteral phantom, a high-speed camera (FASTCAM NOVA S12, Photron Inc.) and visible light were used to record pulse-dependent image analysis of bubbles and stone retropulsion. RESULT: After mounting the artificial stone in the ureteral phantom, the pulse duration and energy of the first pulse of the Moses effect laser were varied; 30 laser shots for 3 s at a repetition rate of 10 Hz were applied to quantify the lithotripsy efficiency and stone retropulsion displacement, and the experimental values were compared. The fragmentation efficiency was confirmed by measuring the mass before and after the laser pulse application, the original position of the stone retropulsion displacement, and the distance moved. The minimum value of stone retropulsion displacement appeared when the pulse duration of the first pulse was 300 µs, the pulse energy was 100 mJ, and the value was approximately 0.28 mm. The highest fragmentation efficiency was observed under the same conditions, and the mass loss of the artificial stone at that time was approximately 3.7 mg. CONCLUSION: Quantitative indices, such as lithotripsy efficiency and stone retropulsion displacement, were confirmed using ultrahigh-speed cameras to determine the effect of the first pulse energy and duration of the Ho: YAG laser with the Moses effect on stone removal. It was confirmed that the longer the duration of the primary pulse and the lower the energy, the higher the fragmentation efficiency. In this study, the possibility of manufacturing a laser with an optimal stone-removal effect was confirmed according to the first-pulse condition of the laser with the Moses effect.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Litotripsia , Lasers de Estado Sólido/uso terapêutico , Sulfato de Cálcio , Água
11.
Int J Urol ; 31(7): 795-801, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38622823

RESUMO

OBJECTIVES: This study aimed to investigate perioperative complications and the details of postoperative ureteral stricture after ureteroscopy with laser lithotripsy (URS-L) for upper urinary tract stones in Japan. METHODS: Patient data on intra- and postoperative complications after ureteroscopy using URS-L were retrospectively collected from multiple centers in Japan between April 2017 and March 2020 with the cooperation of the Japanese Society of Endourology and Robotics. Data included the number of patients undergoing URS-L, number and type of intra- and postoperative complications, and detailed characteristics of postoperative ureteral stricture. RESULTS: In total, 14 125 patients underwent URS-L over 3 years at 82 institutions. Annual URS-L numbers gradually increased from 4419 in 2017, to 4760 in 2018, and 4946 in 2019. The total complication rate was 10.5%, which was divided into intra-operative complications in 1.40% and postoperative complications in 9.18%. The annual incidences of intra- and postoperative complications were not significantly different from year to year (p = 0.314 and p = 0.112). Ureteral perforation, ureteral avulsion, and the intra-operative conversion rate were 1.35%, 0.03%, and 0.02%, respectively. Fever >38°C, septic shock, blood transfusion, and postoperative mortality were 7.44%, 0.81%, 0.07%, and 0.04%, respectively. Ureteral stricture occurred in 0.8% of cases. The median length of stricture site was 10.0 mm and the success rate of stricture treatment was 54.6%. CONCLUSION: Although URS-L utilization has increased in Japan, the annual complication rate has remained steady. Although URS-L is a useful and less invasive procedure, devastating complications can still occur.


Assuntos
Litotripsia a Laser , Complicações Pós-Operatórias , Ureteroscopia , Humanos , Ureteroscopia/efeitos adversos , Japão/epidemiologia , Masculino , Feminino , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Pessoa de Meia-Idade , Litotripsia a Laser/efeitos adversos , Litotripsia a Laser/métodos , Estudos Retrospectivos , Idoso , Adulto , Complicações Intraoperatórias/epidemiologia , Complicações Intraoperatórias/etiologia , Cálculos Ureterais/cirurgia , Cálculos Ureterais/terapia , Obstrução Ureteral/etiologia , Obstrução Ureteral/epidemiologia , Constrição Patológica/etiologia , Constrição Patológica/epidemiologia , Incidência , Cálculos Renais/cirurgia , População do Leste Asiático
12.
Eur J Contracept Reprod Health Care ; 29(2): 76-78, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38284985

RESUMO

CASE: Intrauterine device (IUD) is used worldwide as an effective contraceptive method, but the migration of IUD is a serious complication. We report the case of IUD migration leading to bladder calculus formation and a minimally invasive transurethral surgical approach was performed for treatment. Holmium laser was used to break up the bladder calculus and cut through the bladder mucosa where the IUD was attached, finally the IUD was removed through the urethra. This minimally invasive procedure is a safe and effective treatment for IUD migration, and similar cases have not been reported in the literature. CONCLUSION: That the secondary bladder calculus were smashed by intense pulse mode of holmium laser, and the bladder tissue around the attached IUD was opened by cutting mode of holmium laser, and finally the IUD was completely removed from urethra, this surgical method is safe and effective, and there is no case report on IUD removal of transurethral cystoscope in the literature.

13.
Medicina (Kaunas) ; 60(2)2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-38399633

RESUMO

Background and Objectives: While studies have demonstrated the efficacy of cholangioscopy-guided Holmium-Yttrium aluminum garnet (Ho:YAG) laser lithotripsy for the treatment of refractory bile duct stones, data regarding the safety of the operating parameters for laser lithotripsy are lacking. The aim of this study was to determine safe, yet effective, energy settings for Ho:YAG laser in the ex-vivo model. Materials and Methods: This ex vivo experimental study utilized the Ho:YAG laser on porcine bile duct epithelium and human gallstones. Ho:YAG laser lithotripsy was applied in different power settings from 8 to 15 Watts (W) to six explanted porcine bile ducts. Settings that appeared safe were then utilized to fragment seventy-three human gallstones. Results: The median bile duct perforation times with the Ho:YAG laser between 8-15 W were: >60 s (8 W); 23 s (9 W); 29 s (10 W); 27 s (12 W); 12 s (14 W); and 8 s (15 W). Statistically significant differences in the median perforation times were noted between 8 W vs. 15 W, 9 W vs. 15 W, 10 W vs. 15 W, and 12 W vs. 15 W (p < 0.05). When using a 365 µm Ho:YAG laser probe at 8-12 W, the fragmentation rates on various size stones were: 100% (<1.5 cm); 80-100% (1.6-2.0 cm) and 0-32% (>2.0 cm). Optimal fragmentation was seen utilizing 12 W with high energy (2.4 J) and low frequency (5 Hz) settings. Using a larger 550 µm probe at these settings resulted in 100% fragmentation of stones larger than 2 cm. Conclusions: The Ho:YAG laser appears to be safe and effective in the treatment of large bile duct stones when used between 8-12 W in 5 s bursts in an ex vivo model utilizing porcine bile ducts and human gallstones.


Assuntos
Cálculos Biliares , Lasers de Estado Sólido , Litotripsia a Laser , Litotripsia , Humanos , Suínos , Animais , Cálculos Biliares/cirurgia , Lasers de Estado Sólido/uso terapêutico , Hólmio , Litotripsia a Laser/métodos
14.
Pak J Med Sci ; 40(3Part-II): 394-398, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38356844

RESUMO

Objectives: To construct a predictive model of nosocomial infection in patients with upper urinary tract (UUT) stones after flexible ureterorenoscopy with laser lithotripsy (FURSLL). Methods: Medical records of 196 patients with UUT stones who underwent FURSLL in Suzhou Hospital of Integrated Traditional Chinese and Western Medicine from December 2019 to December 2022 were retrospectively analyzed. Patients were divided into infected group or uninfected group based on the presence of infection during postoperative hospitalization. Univariate and multivariate logistic regressions were used to identify risk factors of postoperative nosocomial infections. A nomogram prediction model was constructed using R software. The predictive ability of the model was assessed using the receiver operating characteristic (ROC) curve. Results: A total of 54 patients (27.6%) developed nosocomial infections after FURSLL. Logistic regression analysis showed that older age, diabetes, preoperative urinary system infection, ureteral stricture, hydronephrosis, double J-stent retention time, and stone diameter were risk factors of nosocomial infection. The nomogram model was constructed based on these risk factors. The ROC showed that the area under the curve (AUC) of the model was 0.930 (95% CI: 0.890-0.970), and the sensitivity and specificity were 92.6% and 81.7%, respectively, indicating that the prediction model was effective. Conclusions: Risk of nosocomial infection in patients with UUT stones after FURSLL is affected by older age, diabetes, preoperative urinary system infection, ureteral stenosis, hydronephrosis, double J-stent retention time, and stone diameter. The nomogram prediction model, constructed based on the above factors, has good predictive value.

15.
World J Urol ; 41(12): 3853-3865, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38010538

RESUMO

OBJECTIVE: Technological advancements in the field of urology have led to a paradigm shift in the management of urolithiasis towards minimally invasive endourological interventions, namely ureteroscopy and percutaneous nephrolithotomy. However, concerns regarding the potential for thermal injury during laser lithotripsy have arisen, as studies have indicated that the threshold for cellular thermal injury (43 °C) can be exceeded, even with conventional low-power laser settings. This review aims to identify the factors that contribute to temperature increments during laser treatment using current laser systems and evaluate their impact on patient outcomes. MATERIALS AND METHODS: To select studies for inclusion, a search was performed on online databases including PubMed and Google Scholar. Keywords such as 'temperature' or 'heat' were combined with 'lithotripsy', 'nephrolithotomy', 'ureteroscopy', or 'retrograde intrarenal surgery', both individually and in various combinations. RESULTS: Various strategies have been proposed to mitigate temperature rise, such as reducing laser energy or frequency, shortening the duration of laser activation, increasing the irrigation fluid flow rate, and using room temperature or chilled water for irrigation. It is important to note that higher irrigation fluid flow rates should be approached cautiously due to potential increases in intrarenal pressure and associated infectious complications. The utilization of a ureteral access sheath (UAS) may offer benefits by facilitating irrigation fluid outflow, thereby reducing intrapelvic pressure and intrarenal fluid temperature. CONCLUSION: Achieving a balance between laser power, duration of laser activation, and irrigation fluid rate and temperature appears to be crucial for urologists to minimize excessive temperature rise.


Assuntos
Cálculos Renais , Lasers de Estado Sólido , Litotripsia a Laser , Ureter , Humanos , Temperatura Alta , Temperatura , Lasers de Estado Sólido/uso terapêutico , Cálculos Renais/cirurgia , Ureteroscopia/efeitos adversos , Litotripsia a Laser/efeitos adversos
16.
World J Urol ; 41(7): 1913-1919, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37222780

RESUMO

PURPOSE: There is a trend toward miniaturization in endourological stone therapy. Good visibility, intrarenal pressures and temperature control should be ensured by ureteral sheaths. In the context of the present study, 10/12 Charr. sheaths and 12/14 Charr. sheaths for flexible ureterorenoscopy were investigated regarding stone-free rate, complication rate and efficacy for laser lithotripsy. METHODS: From January 2020 to January 2022, 100 patients each with kidney stone up to 1.5 cm in diameter were included in the study. Use of a 12/14 Charr. vs. 10/12 Charr. ureteral sheath for flexible ureterorenoscopy was compared. Perioperative data, stone size, volume and density, laser energy, laser duration, stone-free rates and complications based on Clavien-Dindo classification were retrospectively analyzed. RESULTS: For both groups of ureteral access sheaths, there were no differences in median surgery duration (10/12 Charr: 29 min (7-105 min) vs. 12/14 Charr: 34 min (9-95 min); p = 0.33), overall complication rate (p = 0.61) and hospitalization (p = 0.155). There were no differences in stone-free rates (97.9% vs. 92.7%, p = 0.37). Laser lithotripsy duration usingholmium laser was 1.9 min (0.1-10.8 min) vs. 3.8 min (0.2-20.7 min) (p < 0.01) and applied laser energy was 3.1 J (0.15 J-10.29 J) vs. 6.8 J (1.07 J-26.77 J) (p < 0.01) for 12/14 Charr. sheaths and 10/12 Charr. sheaths, respectively. CONCLUSION: In terms of stone-free rates, there are no differences between the 10/12 and 12/14 Charr. ureteral access sheaths. The laser duration and energy was increased with 10/12 Charr. sheaths without showing increased risk for clinical complications like trauma or inflammation.


Assuntos
Cálculos Renais , Litotripsia a Laser , Ureter , Cálculos Ureterais , Humanos , Estudos Retrospectivos , Ureter/cirurgia , Ureteroscopia/efeitos adversos , Cálculos Renais/cirurgia , Cálculos Renais/etiologia , Cálculos Ureterais/cirurgia , Resultado do Tratamento
17.
World J Urol ; 41(5): 1407-1413, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36930255

RESUMO

PURPOSE: To evaluate the perioperative outcomes of retrograde intra-renal surgery (RIRS) for lower pole stones (LPS) and factors affecting stone-free rate (SFR). METHODS: Data from 20 centers were retrospectively reviewed. Inclusion criteria were adult patients, normal renal anatomy, and LPS. Exclusion criteria were bilateral surgery, concomitant surgery for ureteral stones. SFR was defined as a single residual fragment (RF) ≤ 2 mm and evaluated 3-months after surgery. A multivariable logistic regression analysis was performed to assess factors associated with RF. Statistical significance was set at p value < 0.05. RESULTS: 2946 patients were included. Mean age and stone size were 49.9 years 10.19 mm, with multiple LPS in 61.1% of cases. Total operation and laser time were 63.89 ± 37.65 and 17.34 ± 18.39 min, respectively. Mean hospital stay was 3.55 days. Hematuria requiring blood transfusion and fever/urinary infections requiring prolonged antibiotics occurred in 6.1% and 169 5.7% of cases, while sepsis with intensive-care admission in 1.1% of patients. On multivariate analysis, Multiple stones (OR 1.380), stone size (OR 1.865), and reusable ureteroscopes (OR 1.414) were significantly associated with RF, while Thulium fiber laser (TFL) (OR 0.341) and pre-stenting (OR 0.750) were less likely associated with RF. CONCLUSIONS: RIRS showed safety and efficacy for LPS with a mean diameter of 10 mm. This procedure can achieve a satisfactory SFR in pre-stented patients with a single and smaller stone, particularly with TFL use.


Assuntos
Cálculos Renais , Litotripsia , Cálculos Ureterais , Adulto , Humanos , Cálculos Renais/cirurgia , Estudos Retrospectivos , Lipopolissacarídeos , Litotripsia/métodos , Cálculos Ureterais/cirurgia , Resultado do Tratamento
18.
Scand J Gastroenterol ; 58(10): 1213-1220, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37203215

RESUMO

BACKGROUND: Endoscopic management of large bile duct stones may be challenging and refractory to standard endoscopic retrograde cholangiopancreatography (ERCP) techniques. To this end, per-oral cholangioscopy (POC)-guided electrohydraulic lithotripsy (EHL) or laser lithotripsy (LL) has been increasingly utilized during ERCP. There are limited data, however, comparing EHL and LL in the management of choledocholithiasis. Therefore, the aim was to analyze and compare the efficacy of POC-guided EHL and LL for the treatment of choledocholithiasis. METHODS: A database search on PubMed was performed selecting prospective English-language articles published by September 20th, 2022, in accordance with PRISMA guidelines. Studies selected included bile duct clearance as an outcome. RESULTS: A total of 21 prospective studies (15 using LL, 4 using EHL, and 2 both) including 726 patients were included for analysis. Complete ductal clearance was achieved in 639 (88%) patients with 87 (12%) patients having incomplete ductal clearance. Patients treated with LL had an overall median stone clearance success rate of 91.0% (IQR, 82.7-95.5), whereas EHL achieved a median stone clearance success rate of 75.8% (IQR, 74.0-82.4), [p = .03]. CONCLUSIONS: LL is a highly effective form of POC-guided lithotripsy for the treatment of large bile duct stones, particularly when compared to EHL. However, direct, head-to-head randomized trials are needed to identify the most effective form of lithotripsy for treating refractory choledocholithiasis.


Assuntos
Coledocolitíase , Litotripsia a Laser , Litotripsia , Humanos , Litotripsia a Laser/métodos , Coledocolitíase/terapia , Estudos Prospectivos , Resultado do Tratamento , Litotripsia/métodos , Colangiopancreatografia Retrógrada Endoscópica/métodos
19.
Lasers Surg Med ; 55(5): 503-514, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36994818

RESUMO

OBJECTIVES: During holmium:yttrium-aluminum-garnet (holmium:YAG) laser lithotripsy to break urinary stones, urologists frequently see flashes of light. As infrared laser pulses are invisible, what is the source of light? Here we studied the origin, characteristics, and some effects of flashes of light in laser lithotripsy. METHODS: Ultrahigh-speed video-microscopy was used to record single laser pulses at 0.2-1.0 J energy lasered with 242 µm glass-core-diameter fibers in contact with whole surgically retrieved urinary stones and hydroxyapatite (HA)-coated glass slides in air and water. Acoustic transients were measured with a hydrophone. Visible-light and infrared photodetectors resolved temporal profiles of visible-light emission and infrared-laser pulses. RESULTS: Temporal profiles of laser pulses showed intensity spikes of various duration and amplitude. The pulses were seen to produce dim light and bright sparks with submicrosecond risetime. The spark produced by the intensity spike at the beginning of laser pulse generated a shock wave in the surrounding liquid. The subsequent sparks were in a vapor bubble and generated no shock waves. Sparks enhanced absorption of laser radiation, indicative of plasma formation and optical breakdown. The occurrence and number of sparks varied even with the same urinary stone. Sparks were consistently observed at laser energy >0.5 J with HA-coated glass slides. The slides broke or cracked by cavitation with sparks in 63 ± 15% of pulses (1.0 J, N = 60). No glass-slide breakage occurred without sparks (1.0 J, N = 500). CONCLUSION: Unappreciated in previous studies, plasma formation with free-running long-pulse holmium:YAG lasers can be an additional physical mechanism of action in laser procedures.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Cálculos Urinários , Humanos , Litotripsia a Laser/métodos , Lasers de Estado Sólido/uso terapêutico , Hólmio , Cálculos Urinários/terapia , Ítrio
20.
Can J Urol ; 30(3): 11574-11582, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37344471

RESUMO

In North America, ureteroscopy has become the most popular treatment modality for upper urinary tract urinary calculi. Herein we describe our technique for the treatment of renal stones with flexible ureteroscopy and high-power holmium laser lithotripsy. We discuss preoperative planning, intraoperative strategies, and laser settings for a high-frequency dusting technique with the goal to provide optimal patient outcomes.


Assuntos
Cálculos Renais , Lasers de Estado Sólido , Litotripsia a Laser , Cálculos Ureterais , Ureteroscopia , Cálculos Urinários , Urolitíase , Humanos , Hólmio , Cálculos Renais/cirurgia , Lasers de Estado Sólido/uso terapêutico , Litotripsia a Laser/métodos , Resultado do Tratamento , Cálculos Ureterais/cirurgia , Ureteroscopia/métodos , Cálculos Urinários/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA