Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 504
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Am J Respir Crit Care Med ; 209(6): 716-726, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38016085

RESUMO

Rationale: The impact of a household air pollution (HAP) stove intervention on child lung function has been poorly described. Objectives: To assess the effect of a HAP stove intervention for infants prenatally to age 1 on, and exposure-response associations with, lung function at child age 4. Methods: The Ghana Randomized Air Pollution and Health Study randomized pregnant women to liquefied petroleum gas (LPG), improved biomass, or open-fire (control) stove conditions through child age 1. We quantified HAP exposure by repeated maternal and child personal carbon monoxide (CO) exposure measurements. Children performed oscillometry, an effort-independent lung function measurement, at age 4. We examined associations between Ghana Randomized Air Pollution and Health Study stove assignment and prenatal and infant CO measurements and oscillometry using generalized linear regression models. We used reverse distributed lag models to examine time-varying associations between prenatal CO and oscillometry. Measurements and Main Results: The primary oscillometry measure was reactance at 5 Hz, X5, a measure of elastic and inertial lung properties. Secondary measures included total, large airway, and small airway resistance at 5 Hz, 20 Hz, and the difference in resistance at 5 Hz and 20 Hz (R5, R20, and R5-20, respectively); area of reactance (AX); and resonant frequency. Of the 683 children who attended the lung function visit, 567 (83%) performed acceptable oscillometry. A total of 221, 106, and 240 children were from the LPG, improved biomass, and control arms, respectively. Compared with control, the improved biomass stove condition was associated with lower reactance at 5 Hz (X5 z-score: ß = -0.25; 95% confidence interval [CI] = -0.39, -0.11), higher large airway resistance (R20 z-score: ß = 0.34; 95% CI = 0.23, 0.44), and higher AX (AX z-score: ß = 0.16; 95% CI = 0.06, 0.26), which is suggestive of overall worse lung function. The LPG stove condition was associated with higher X5 (X5 score: ß = 0.16; 95% CI = 0.01, 0.31) and lower small airway resistance (R5-20 z-score: ß = -0.15; 95% CI = -0.30, 0.0), which is suggestive of better small airway function. Higher average prenatal CO exposure was associated with higher R5 and R20, and distributed lag models identified sensitive windows of exposure between CO and X5, R5, R20, and R5-20. Conclusions: These data support the importance of prenatal HAP exposure on child lung function. Clinical trial registered with www.clinicaltrials.gov (NCT01335490).


Assuntos
Poluição do Ar , Pré-Escolar , Feminino , Humanos , Lactente , Gravidez , Poluição do Ar/efeitos adversos , Resistência das Vias Respiratórias/fisiologia , Gana/epidemiologia , Pulmão , Gestantes
2.
J Allergy Clin Immunol ; 154(1): 94-100.e13, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38244724

RESUMO

BACKGROUND: Asthmatic symptoms often start during early childhood. Impulse oscillometry (IOS) is feasible in preschool children who may be unable to reliably perform spirometry measurements. OBJECTIVE: We sought to evaluate the use of IOS in a multicenter, multiethnic high-risk asthma cohort titled the Vitamin D Antenatal Asthma Reduction Trial. METHODS: The trial recruited pregnant women whose children were followed from birth to age 8 years. Lung function was assessed with IOS at ages 4, 5, and 6 years and spirometry at ages 5, 6, 7, and 8 years. Asthma status, respiratory symptoms, and medication use were assessed with repeated questionnaires from birth to age 8 years. RESULTS: In total, 220 children were included in this secondary analysis. Recent respiratory symptoms and short-acting ß2-agonist use were associated with increased respiratory resistance at 5 Hz at age 4 years (ß = 2.6; 95% CI, 1.0 to 4.4; P = .002 and ß = 3.4; 95% CI, 0.7 to 6.2; P = .015, respectively). Increased respiratory resistance at 5 Hz at age 4 years was also associated with decreased lung function from ages 5 to 8 years (ß = -0.3; 95% CI, -0.5 to -0.1; P < .001 for FEV1 at 8 years) and active asthma at age 8 years (ß = 2.0; 95% CI, 0.2 to 3.8; P = .029). CONCLUSIONS: Increased respiratory resistance in preschool IOS is associated with frequent respiratory symptoms as well as school-age asthma and lung function impairment. Our findings suggest that IOS may serve as a potential objective measure for early identification of children who are at high risk of respiratory morbidity.


Assuntos
Asma , Oscilometria , Humanos , Asma/fisiopatologia , Asma/diagnóstico , Pré-Escolar , Feminino , Criança , Masculino , Testes de Função Respiratória , Pulmão/fisiopatologia , Lactente , Gravidez , Espirometria , Recém-Nascido
3.
J Allergy Clin Immunol ; 154(2): 316-324.e3, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38574825

RESUMO

BACKGROUND: Allergic sensitization and low lung function in early childhood are risk factors for subsequent wheezing and asthma. However, it is unclear how allergic sensitization affects lung function over time. OBJECTIVE: We sought to test whether allergy influences lung function and whether these factors synergistically increase the risk of continued wheezing in childhood. METHODS: We analyzed longitudinal measurements of lung function (spirometry and impulse oscillometry) and allergic sensitization (aeroallergen skin tests and serum allergen-specific IgE) throughout early childhood in the Urban Environmental and Childhood Asthma study, which included high-risk urban children living in disadvantaged neighborhoods. Intraclass correlation coefficients were calculated to assess lung function stability. Cluster analysis identified low, medium, and high allergy trajectories, which were compared with lung function and wheezing episodes in linear regression models. A variable selection model assessed predictors at age 5 years for continued wheezing through age 12 years. RESULTS: Lung function adjusted for growth was stable (intraclass correlation coefficient, 0.5-0.7) from age 5 to 12 years and unrelated to allergy trajectory. Lung function and allergic sensitization were associated with wheezing episodes in an additive fashion. In children with asthma, measuring lung function at age 5 years added little to the medical history for predicting future wheezing episodes through age 12 years. CONCLUSIONS: In high-risk urban children, age-related trajectories of allergic sensitization were not associated with lung function development; however, both indicators were related to continued wheezing. These results underscore the importance of understanding early-life factors that negatively affect lung development and suggest that treating allergic sensitization may not alter lung function development in early to mid-childhood.


Assuntos
Pulmão , Sons Respiratórios , População Urbana , Humanos , Sons Respiratórios/fisiopatologia , Sons Respiratórios/imunologia , Masculino , Feminino , Pré-Escolar , Criança , Pulmão/fisiopatologia , Pulmão/imunologia , Asma/fisiopatologia , Asma/epidemiologia , Asma/imunologia , Hipersensibilidade/epidemiologia , Hipersensibilidade/imunologia , Hipersensibilidade/fisiopatologia , Imunoglobulina E/sangue , Imunoglobulina E/imunologia , Testes de Função Respiratória , Fatores de Risco , Alérgenos/imunologia , Testes Cutâneos
4.
Am J Physiol Lung Cell Mol Physiol ; 327(2): L203-L217, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38771135

RESUMO

This study investigated the relationship between three respiratory support approaches on lung volume recruitment during the first 2 h of postnatal life in preterm lambs. We estimated changes in lung aeration, measuring respiratory resistance and reactance by oscillometry at 5 Hz. We also measured intratracheal pressure in subsets of lambs. The first main finding is that sustained inflation (SI) applied noninvasively (Mask SI; n = 7) or invasively [endotracheal tube (ETT) SI; n = 6] led to similar rapid lung volume recruitment (∼6 min). In contrast, Mask continuous positive airway pressure (CPAP) without SI (n = 6) resuscitation took longer (∼30-45 min) to reach similar lung volume recruitment. The second main finding is that, in the first 15 min of postnatal life, the Mask CPAP without SI group closed their larynx during custom ventilator-driven expiration, leading to intratracheal positive end-expiratory pressure of ∼17 cmH2O (instead of 8 cmH2O provided by the ventilator). In contrast, the Mask SI group used the larynx to limit inspiratory pressure to ∼26 cmH2O (instead of 30 cmH2O provided by the ventilator). These different responses affected tidal volume, being larger in the Mask CPAP without SI group [8.4 mL/kg; 6.7-9.3 interquartile range (IQR)] compared to the Mask SI (5.0 mL/kg; 4.4-5.2 IQR) and ETT SI groups (3.3 mL/kg; 2.6-3.7 IQR). Distinct physiological responses suggest that spontaneous respiratory activity of the larynx of preterm lambs at birth can uncouple pressure applied by the ventilator to that applied to the lung, leading to unpredictable lung pressure and tidal volume delivery independently from the ventilator settings.NEW & NOTEWORTHY We compared invasive and noninvasive resuscitation on lambs at birth, including or not sustained inflation (SI). Lung volume recruitment was faster in those receiving SI. During noninvasive resuscitation, larynx modulation reduced tracheal pressure from that applied to the mask in lambs receiving SI, while it led to increased auto-positive end-expiratory pressure and very large tidal volumes in lambs not receiving SI. Our results highlight the need for individualizing pressures and monitoring tidal volumes during resuscitation at birth.


Assuntos
Animais Recém-Nascidos , Pulmão , Volume de Ventilação Pulmonar , Traqueia , Animais , Volume de Ventilação Pulmonar/fisiologia , Ovinos , Pulmão/fisiologia , Traqueia/fisiologia , Mecânica Respiratória/fisiologia , Pressão Positiva Contínua nas Vias Aéreas/métodos , Ressuscitação/métodos , Intubação Intratraqueal/métodos , Pressão , Respiração com Pressão Positiva/métodos
5.
Respir Res ; 25(1): 298, 2024 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-39113017

RESUMO

BACKGROUND: Increasing functional residual capacity (FRC) or tidal volume (VT) reduces airway resistance and attenuates the response to bronchoconstrictor stimuli in animals and humans. What is unknown is which one of the above mechanisms is more effective in modulating airway caliber and whether their combination yields additive or synergistic effects. To address this question, we investigated the effects of increased FRC and increased VT in attenuating the bronchoconstriction induced by inhaled methacholine (MCh) in healthy humans. METHODS: Nineteen healthy volunteers were challenged with a single-dose of MCh and forced oscillation was used to measure inspiratory resistance at 5 and 19 Hz (R5 and R19), their difference (R5-19), and reactance at 5 Hz (X5) during spontaneous breathing and during imposed breathing patterns with increased FRC, or VT, or both. Importantly, in our experimental design we held the product of VT and breathing frequency (BF), i.e, minute ventilation (VE) fixed so as to better isolate the effects of changes in VT alone. RESULTS: Tripling VT from baseline FRC significantly attenuated the effects of MCh on R5, R19, R5-19 and X5. Doubling VT while halving BF had insignificant effects. Increasing FRC by either one or two VT significantly attenuated the effects of MCh on R5, R19, R5-19 and X5. Increasing both VT and FRC had additive effects on R5, R19, R5-19 and X5, but the effect of increasing FRC was more consistent than increasing VT thus suggesting larger bronchodilation. When compared at iso-volume, there were no differences among breathing patterns with the exception of when VT was three times larger than during spontaneous breathing. CONCLUSIONS: These data show that increasing FRC and VT can attenuate induced bronchoconstriction in healthy humans by additive effects that are mainly related to an increase of mean operational lung volume. We suggest that static stretching as with increasing FRC is more effective than tidal stretching at constant VE, possibly through a combination of effects on airway geometry and airway smooth muscle dynamics.


Assuntos
Broncoconstrição , Cloreto de Metacolina , Volume de Ventilação Pulmonar , Humanos , Broncoconstrição/efeitos dos fármacos , Broncoconstrição/fisiologia , Volume de Ventilação Pulmonar/fisiologia , Volume de Ventilação Pulmonar/efeitos dos fármacos , Masculino , Feminino , Adulto , Adulto Jovem , Cloreto de Metacolina/administração & dosagem , Broncoconstritores/administração & dosagem , Testes de Provocação Brônquica/métodos , Capacidade Residual Funcional/fisiologia , Capacidade Residual Funcional/efeitos dos fármacos , Voluntários Saudáveis , Resistência das Vias Respiratórias/efeitos dos fármacos , Resistência das Vias Respiratórias/fisiologia , Pulmão/efeitos dos fármacos , Pulmão/fisiologia , Volume Expiratório Forçado/fisiologia , Volume Expiratório Forçado/efeitos dos fármacos
6.
Respir Res ; 25(1): 149, 2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38555433

RESUMO

BACKGROUND: The clinical significance of the impulse oscillometry-defined small airway bronchodilator response (IOS-BDR) is not well-known. Accordingly, this study investigated the clinical characteristics of IOS-BDR and explored the association between lung function decline, acute respiratory exacerbations, and IOS-BDR. METHODS: Participants were recruited from an Early Chronic Obstructive Pulmonary Disease (ECOPD) cohort subset and were followed up for two years with visits at baseline, 12 months, and 24 months. Chronic obstructive pulmonary disease (COPD) was defined as a post-bronchodilator forced expiratory volume in 1 s (FEV1)/forced vital capacity (FVC) ratio < 0.70. IOS-BDR was defined as meeting any one of the following criteria: an absolute change in respiratory system resistance at 5 Hz ≤ - 0.137 kPa/L/s, an absolute change in respiratory system reactance at 5 Hz ≥ 0.055 kPa/L/s, or an absolute change in reactance area ≤ - 0.390 kPa/L. The association between IOS-BDR and a decline in lung function was explored with linear mixed-effects model. The association between IOS-BDR and the risk of acute respiratory exacerbations at the two-year follow-up was analyzed with the logistic regression model. RESULTS: This study involved 466 participants (92 participants with IOS-BDR and 374 participants without IOS-BDR). Participants with IOS-BDR had higher COPD assessment test and modified Medical Research Council dyspnea scale scores, more severe emphysema, air trapping, and rapid decline in FVC than those without IOS-BDR over 2-year follow-up. IOS-BDR was not associated with the risk of acute respiratory exacerbations at the 2-year follow-up. CONCLUSIONS: The participants with IOS-BDR had more respiratory symptoms, radiographic structural changes, and had an increase in decline in lung function than those without IOS-BDR. TRIAL REGISTRATION: Chinese Clinical Trial Registry, ChiCTR1900024643. Registered on 19 July, 2019.


Assuntos
Asma , Doença Pulmonar Obstrutiva Crônica , Humanos , Asma/diagnóstico , Broncodilatadores/uso terapêutico , Volume Expiratório Forçado , Oscilometria , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Testes de Função Respiratória , Espirometria
7.
Respir Res ; 25(1): 286, 2024 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-39048993

RESUMO

BACKGROUND: The use of machine learning(ML) methods would improve the diagnosis of small airway dysfunction(SAD) in subjects with chronic respiratory symptoms and preserved pulmonary function(PPF). This paper evaluated the performance of several ML algorithms associated with the impulse oscillometry(IOS) analysis to aid in the diagnostic of respiratory changes in SAD. We also find out the best configuration for this task. METHODS: IOS and spirometry were measured in 280 subjects, including a healthy control group (n = 78), a group with normal spirometry (n = 158) and a group with abnormal spirometry (n = 44). Various supervised machine learning (ML) algorithms and feature selection strategies were examined, such as Support Vector Machines (SVM), Random Forests (RF), Adaptive Boosting (ADABOOST), Navie Bayesian (BAYES), and K-Nearest Neighbors (KNN). RESULTS: The first experiment of this study demonstrated that the best oscillometric parameter (BOP) was R5, with an AUC value of 0.642, when comparing a healthy control group(CG) with patients in the group without lung volume-defined SAD(PPFN). The AUC value of BOP in the control group was 0.769 compared with patients with spirometry defined SAD(PPFA) in the PPF population. In the second experiment, the ML technique was used. In CGvsPPFN, RF and ADABOOST had the best diagnostic results (AUC = 0.914, 0.915), with significantly higher accuracy compared to BOP (p < 0.01). In CGvsPPFA, RF and ADABOOST had the best diagnostic results (AUC = 0.951, 0.971) and significantly higher diagnostic accuracy (p < 0.01). In the third, fourth and fifth experiments, different feature selection techniques allowed us to find the best IOS parameters (R5, (R5-R20)/R5 and Fres). The results demonstrate that the performance of ADABOOST remained essentially unaltered following the application of the feature selector, whereas the diagnostic accuracy of the remaining four classifiers (RF, SVM, BAYES, and KNN) is marginally enhanced. CONCLUSIONS: IOS combined with ML algorithms provide a new method for diagnosing SAD in subjects with chronic respiratory symptoms and PPF. The present study's findings provide evidence that this combination may help in the early diagnosis of respiratory changes in these patients.


Assuntos
Aprendizado de Máquina , Espirometria , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Espirometria/métodos , Idoso , Oscilometria/métodos , Máquina de Vetores de Suporte , Pulmão/fisiopatologia
8.
Respir Res ; 25(1): 300, 2024 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-39113044

RESUMO

BACKGROUND: In recent years, the incorporation of LAMAs into asthma therapy has been expected to enhance symptom control. However, a significant number of patients with asthma continue to experience poorly managed symptoms. There have been limited investigations on LAMA-induced airway alterations in asthma treatment employing IOS. In this study, we administered a LAMA to patients with poorly controlled asthma, evaluated clinical responses and respiratory function, and investigated airway changes facilitated by LAMA treatments using the IOS. METHODS: Of a total of 1282 consecutive patients with asthma, 118 exhibited uncontrolled symptoms. Among them, 42 switched their treatment to high-dose fluticasone furoate/umeclidinium/vilanterol (FF/UMEC/VI) (ICS/LABA/LAMA). The patients were then assessed using AHQ-33 or LCQ and ACT. Spirometry parameters (such as FEV1 or MMEF) and IOS parameters (such as R20 or AX) were measured and compared before and after exacerbations and the addition of LAMA. RESULTS: Of the 42 patients, 17 who switched to FF/UMEC/VI caused by dyspnea exhibited decreased pulmonary function between period 1 and baseline, followed by an increase in pulmonary function between baseline and period 2. Significant differences were observed in IOS parameters such as R20, R5-R20, Fres, or AX between period 1 and baseline as well as between baseline and period 2. Among the patients who switched to inhaler due to cough, 25 were classified as responders (n = 17) and nonresponders (n = 8) based on treatment outcomes. Among nonresponders, there were no significant differences in spirometry parameters such as FEV1 or PEF and IOS parameters such as R20 or AX between period 1 and baseline. However, among responders, significant differences were observed in all IOS parameters, though not in most spirometry parameters, between period 1 and baseline. Furthermore, significant differences were noted between baseline and period 2 in terms of FEV1, %MMEF, %PEF, and all IOS parameters. CONCLUSION: ICS/LABA/LAMA demonstrates superiority over ICS/LABA in improving symptoms and lung function, which is primarily attributed to the addition of LAMA. Additionally, IOS revealed the effectiveness of LAMA across all airway segments, particularly in the periphery. Hence, LAMA can be effective against various asthma phenotypes characterized by airway inflammation, even in real-world cases.


Assuntos
Asma , Antagonistas Muscarínicos , Oscilometria , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Antagonistas Muscarínicos/administração & dosagem , Asma/tratamento farmacológico , Asma/fisiopatologia , Asma/diagnóstico , Resultado do Tratamento , Oscilometria/métodos , Adulto , Idoso , Combinação de Medicamentos , Quinuclidinas/administração & dosagem , Clorobenzenos/administração & dosagem , Broncodilatadores/administração & dosagem , Antiasmáticos/administração & dosagem , Antiasmáticos/uso terapêutico
9.
J Asthma ; 61(8): 801-807, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38198535

RESUMO

BACKGROUND: We investigated the correlation between urine VOC metabolites and airway function in children exposed to anthropogenic volatile organic compounds (VOCs), notable pollutants impacting respiratory health. METHODS: Out of 157 respondents, 141 completed skin prick tests, spirometry, IOS, and provided urine samples following the International Study of Asthma and Allergies in Childhood (ISAAC)-related questions. Allergic sensitization was assessed through skin prick tests, and airway functions were evaluated using spirometry and impulse oscillometry (IOS). Forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC) was recorded and FEV1/FVC ratio was calculated. Airway mechanics parameters including respiratory resistance at 5 Hz (Rrs5) mean respiratory resistance between 5 Hz and 20 Hz (Rrs5-20), were also recorded. Urine concentrations of metabolites of benzene, ethylbenzene, toluene, xylene, styrene, formaldehyde, carbon-disulfide were analyzed by gas chromatography/tandem mass spectroscopy. RESULTS: The median age at study participation was 7.1 (SD 0.3) years. Muconic acid (benzene metabolites) and o-methyl-hippuric acid (xylene metabolites) above medians were associated with a significant increase in Rrs5 (muconic acid: aß = 0.150, p = .002; o-methyl-hippuric acid: aß = 0.143, p = .023) and a decrease in FEV1/FVC (o-methyl-hippuric acid: aß = 0.054, p = .028) compared to those below median. No associations were observed for Rrs5-20 and FEV1 between the groups categorized as above and below the median (all parameter p values > .05). CONCLUSIONS: Elevated levels of benzene and xylene metabolites were associated with a significant increase in Rrs5 and a decrease in FEV1/FVC, related to increased resistance and restrictive lung conditions compared to individuals with concentrations below the median.


Assuntos
Compostos Orgânicos Voláteis , Humanos , Criança , Compostos Orgânicos Voláteis/urina , Masculino , Feminino , Capacidade Vital , Espirometria , Volume Expiratório Forçado , Testes Cutâneos , Ácido Sórbico/análogos & derivados , Ácido Sórbico/análise , Exposição Ambiental/efeitos adversos , Exposição Ambiental/análise , Testes de Função Respiratória , Xilenos/urina , Benzeno/análise , Resistência das Vias Respiratórias , Derivados de Benzeno/urina , Poluentes Atmosféricos/urina , Poluentes Atmosféricos/análise , Poluentes Atmosféricos/efeitos adversos , Asma/urina , Asma/fisiopatologia , Hipuratos/urina , Oscilometria , Pulmão
10.
J Asthma ; : 1-10, 2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38747533

RESUMO

BACKGROUND: Small airway dysfunction (SAD) is increasingly recognized as an important feature of pediatric asthma yet typically relies on spirometry-derived FEF25-75 to detect its presence. Multiple breath washout (MBW) and oscillometry potentially offer improved sensitivity for SAD detection, but their utility in comparison to FEF25-75, and correlations with clinical outcomes remains unclear for school-age asthma. We investigated SAD occurrence using these techniques, between-test correlation and links to clinical outcomes in 57 asthmatic children aged 8-18 years. METHODS: MBW and spirometry abnormality were defined as z-scores above/below ± 1.96, generating MBW reference equations from contemporaneous controls (n = 69). Abnormal oscillometry was defined as > 97.5th percentile, also from contemporaneous controls (n = 146). Individuals with abnormal FEF25-75, MBW, or oscillometry were considered to have SAD. RESULTS: Using these limits of normal, SAD was present on oscillometry in 63% (resistance at 5-20 Hz; R5-R20; >97.5th percentile), on MBW in 54% (Scond; z-scores> +1.96) and in spirometry FEF25-75 in 44% of participants (z-scores< -1.96). SAD, defined by oscillometry and/or MBW abnormality, occurred in 77%. Among those with abnormal R5-R20, Scond was abnormal in 71%. Correlations indicated both R5-R20 and Scond were linked to asthma medication burden, baseline FEV1 and reversibility. Additionally, Scond correlated with FENO and magnitude of bronchial hyper-responsiveness. SAD, detected by oscillometry and/or MBW, occurred in almost 80% of school-aged asthmatic children, surpassing FEF25-75 detection rates. CONCLUSIONS: Discordant oscillometry and MBW abnormality suggests they reflect different aspects of SAD, serving as complementary tools. Key asthma clinical features, like reversibility, had stronger correlation with MBW-derived Scond than oscillometry-derived R5-R20.

11.
J Asthma ; 61(9): 1076-1082, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38426671

RESUMO

INTRODUCTION: Reactance inversion (RI) has been associated with impaired peripheral airway function in persistent asthma. However, there is little to no data about the difference between asthmatic children with and without RI. This study aimed to detect clinical and lung function differences in moderate-severe asthmatic children with and without RI. METHODS: This study was conducted between 2021 and 2022 in asthmatic school-age children. Impulse oscillometry (IOS) and spirometry were performed according to ATS/ERS standards. RESULTS: A total of 62 patients, with a mean age of 8.4 years, 54.8% were males and were divided into three groups: group 1 (32.3%) with no RI, group 2 (27.4%) with RI but disappearing after bronchodilator test and group 3 (40.3%) with persistent RI after bronchodilator test. Children in groups 2 and 3 had significantly lower birth weights than in group 1. Group 2 had lower gestational age compared to group 1. FEV1 and FEF25-75 of forced vital capacity were significantly lower in groups 2 and 3. In group 3, R5, AX, R5-20, and R5-R20/R5 ratios were significantly higher. Bronchodilator responses (BDR) in X5c, AX, and R5-R20 were significantly different between groups and lower in group 3. CONCLUSION: RI is frequently found in children with moderate-severe persistent asthma, particularly in those with a history of prematurity or low birth weight. In some patients, RI disappears after the bronchodilator test; however, it, persists in those with the worst pulmonary function. RI could be a small airway dysfunction marker.


Assuntos
Asma , Broncodilatadores , Recém-Nascido de Baixo Peso , Humanos , Asma/fisiopatologia , Asma/tratamento farmacológico , Masculino , Feminino , Criança , Broncodilatadores/uso terapêutico , Broncodilatadores/administração & dosagem , Espirometria , Índice de Gravidade de Doença , Testes de Função Respiratória , Oscilometria , Recém-Nascido
12.
Acta Anaesthesiol Scand ; 68(3): 311-320, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37923301

RESUMO

BACKGROUND: Lung volume loss is a major risk factor for postoperative respiratory complications after general anaesthesia and mechanical ventilation. We hypothesise that spontaneous breathing without pressure support may enhance the risk for atelectasis development. Therefore, we aimed at characterising whether pressure support prevents changes in lung function in patients breathing spontaneously through laryngeal mask airway. METHODS: In this randomised controlled trial, adult female patients scheduled for elective gynaecological surgery in lithotomy position were randomly assigned to the continuous spontaneous breathing group (CSB, n = 20) or to the pressure support ventilation group (PSV, n = 20) in a tertiary university hospital. Lung function measurements were carried out before anaesthesia and 1 h postoperatively by a researcher blinded to the group allocation. Lung clearance index calculated from end-expiratory lung volume turnovers as primary outcome variable was assessed by the multiple-breath nitrogen washout technique (MBW). Respiratory mechanics were measured by forced oscillations to assess parameters reflecting the small airway function and respiratory tissue stiffness. RESULTS: MBW was successfully completed in 18 patients in both CSB and PSV groups. The decrease in end-expiratory lung volume was more pronounced in the CSB than that in the PSV group (16.6 ± 6.6 [95% CI] % vs. 7.6 ± 11.1%, p = .0259), with no significant difference in the relative changes of the lung clearance index (-0.035 ± 7.1% vs. -0.18 ± 6.6%, p = .963). The postoperative changes in small airway function and respiratory tissue stiffness were significantly lower in the PSV than in the CSB group (p < .05 for both). CONCLUSIONS: These results suggest that pressure support ventilation protects against postoperative lung-volume loss without affecting ventilation inhomogeneity in spontaneously breathing patients with increased risk for atelectasis development. TRIAL REGISTRATION: NCT02986269.


Assuntos
Atelectasia Pulmonar , Respiração , Adulto , Humanos , Feminino , Respiração Artificial , Respiração com Pressão Positiva/métodos , Anestesia Geral
13.
J Investig Allergol Clin Immunol ; 34(2): 106-117, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-36645713

RESUMO

BACKGROUND AND OBJECTIVES: Background: Static lung hyperinflation (SLH) measured using body plethysmography in patients with asthma is associated with poor outcomes. The severity of SLH may be associated with small airway dysfunction (SAD), which can be measured using impulse oscillometry (IOS). Objective: This study aims to determine the correlation between SLH and SAD in patients with severe asthma and assess the improvement in SLH and SAD with treatment. METHODS: We analyzed data from patients who were enrolled in the Taiwan Severe Asthma Registry, which comprises a prospective observational cohort. Plethysmography and IOS were performed regularly. The relationship between spirometry and IOS parameters was determined. Changes in the clinical outcomes in response to treatment were analyzed. RESULTS: Of 107 patients with severe asthma, 83 (77.6%) had SLH based on an increased residual volume to total lung capacity ratio (RV/ TLC). Most patients were older women with worse pulmonary function and SAD than those without SLH. SAD, defined as increased airway resistance/reactance, was significantly correlated with SLH. Airway reactance at 5 Hz (X5) ≤-0.21 kPa/(L/s) detected SLH with an area under the receiver operating characteristic curve of 0.84 (P<.0001; sensitivity, 85.2%; and specificity, 83.3%). After 12 months, patients who received add-on biologics (vs those who did not) had significantly reduced exacerbations, fractional exhaled nitric oxide level, and blood eosinophil counts, as well as improved forced expiratory volume in the first second, X5, and a trend toward reduced RV/TLC ratio. CONCLUSIONS: In severe asthma, airway reactance (X5) could be a novel parameter for assessing SLH.

14.
BMC Pulm Med ; 24(1): 10, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38167026

RESUMO

BACKGROUND: Idiopathic pulmonary fibrosis (IPF) is a progressive disease with a poor prognosis. Pulmonary function tests (PFTs) aid in evaluating the disease status of IPF. The clinical significance of oscillometry measurements in interstitial lung diseases has recently been reported. Our previous study showed that respiratory reactance (Xrs) measured by oscillometry reflected disease severity and predicted subsequent lung capacity decline in patients with IPF. However, the direct impact of Xrs on survival needs to be determined, and there are currently no reference values in oscillometry to predict prognosis. Therefore, this study aimed to investigate the association between oscillometry measurements, particularly Xrs, and survival in patients with IPF and to determine the cutoff values of Xrs that predict 3-year survival. METHODS: We analyzed the relationship between the measured values of PFT and oscillometry derived from 178 patients with IPF. Univariate and multivariate Cox proportional hazards analyses were performed to investigate the relationships between clinical indices at the time of the first oscillometry and survival. We performed the time-dependent receiver operating characteristic (ROC) curve analysis to set the optimized cutoff values of Xrs for 3-year survival prediction. We examined the discriminating power of cutoff values of Xrs on survival using the Kaplan-Meier method and the log-rank test. RESULTS: Xrs components, especially in the inspiratory phase (In), significantly correlated with the PFT values. In the multivariate analyses, Xrs (all of reactance at 5 Hz [X5], resonant frequency [Fres], and low-frequency reactance area [ALX] in the inspiratory phase) had a significant impact on survival (X5, p = 0.003; Fres, p = 0.016; ALX, p = 0.003) independent of age, sex, and other prognostic factors derived from the univariate analysis. The area under the ROC curve was 0.765, 0.759, and 0.766 for X5 In, Fres In, and ALX In, with cutoff values determined at - 0.98, 10.67, and 5.32, respectively. We found significant differences in survival after dividing patients using each of the cutoff values of Xrs. CONCLUSIONS: In patients with IPF, Xrs measured by oscillometry significantly impacted survival. We also determined the cutoff values of Xrs to discriminate patients with poor prognoses.


Assuntos
Resistência das Vias Respiratórias , Fibrose Pulmonar Idiopática , Humanos , Oscilometria/métodos , Pulmão , Testes de Função Respiratória/métodos , Fibrose Pulmonar Idiopática/diagnóstico
15.
BMC Anesthesiol ; 24(1): 221, 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38961365

RESUMO

BACKGROUND: This study aimed to evaluate the accuracy of ankle blood pressure measurements in relation to invasive blood pressure in the lateral position. METHODS: This prospective observational study included adult patients scheduled for elective non-cardiac surgery under general anesthesia in the lateral position. Paired radial artery invasive and ankle noninvasive blood pressure readings were recorded in the lateral position using GE Carescape B650 monitor. The primary outcome was the ability of ankle mean arterial pressure (MAP) to detect hypotension (MAP < 70 mmHg) using area under the receiver operating characteristic curve (AUC) analysis. The secondary outcomes were the ability of ankle systolic blood pressure (SBP) to detect hypertension (SBP > 140 mmHg) as well as bias (invasive measurement - noninvasive measurement), and agreement between the two methods using the Bland-Altman analysis. RESULTS: We analyzed 415 paired readings from 30 patients. The AUC (95% confidence interval [CI]) of ankle MAP for detecting hypotension was 0.88 (0.83-0.93). An ankle MAP of ≤ 86 mmHg had negative and positive predictive values (95% CI) of 99 (97-100)% and 21 (15-29)%, respectively, for detecting hypotension. The AUC (95% CI) of ankle SBP to detect hypertension was 0.83 (0.79-0.86) with negative and positive predictive values (95% CI) of 95 (92-97)% and 36 (26-46)%, respectively, at a cutoff value of > 144 mmHg. The mean bias between the two methods was - 12 ± 17, 3 ± 12, and - 1 ± 11 mmHg for the SBP, diastolic blood pressure, and MAP, respectively. CONCLUSION: In patients under general anesthesia in the lateral position, ankle blood pressure measurements are not interchangeable with the corresponding invasive measurements. However, an ankle MAP > 86 mmHg can exclude hypotension with 99% accuracy, and an ankle SBP < 144 mmHg can exclude hypertension with 95% accuracy.


Assuntos
Anestesia Geral , Tornozelo , Determinação da Pressão Arterial , Humanos , Feminino , Anestesia Geral/métodos , Masculino , Estudos Prospectivos , Pessoa de Meia-Idade , Determinação da Pressão Arterial/métodos , Tornozelo/irrigação sanguínea , Idoso , Oscilometria/métodos , Pressão Sanguínea/fisiologia , Hipertensão/fisiopatologia , Hipertensão/diagnóstico , Hipotensão/diagnóstico , Hipotensão/fisiopatologia , Adulto , Posicionamento do Paciente/métodos
16.
BMC Pediatr ; 24(1): 296, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38702638

RESUMO

BACKGROUND: Cough variant asthma (CVA) is one of the most common causes of chronic cough in children worldwide. The diagnosis of CVA in children remains challenging. This study aimed to assess the diagnostic utility of impulse oscillometry (IOS) pulmonary function in children with CVA. METHODS: This study included children aged 4 to 12 years diagnosed with CVA who underwent IOS pulmonary function and bronchodilation (BD) tests. A control group of healthy children was matched. Pre- and post-BD IOS parameters were recorded and presented as mean ± standard deviation or median. Receiver operating characteristic (ROC) curves were plotted, and the area under the curve (AUC) was calculated to evaluate the discriminatory potential of the IOS parameters for diagnosing CVA. RESULTS: A total of 180 patients with CVA and 65 control subjects were included. The baseline IOS parameters in the CVA group, except X5%pred, were significantly greater compared to the control group. After inhalation of salbutamol sulfate, all IOS parameters improved significantly in the CVA group. However, Z5%pred, R5%pred, and R20%pred remained greater in the CVA group compared to the control group. The improvement rates of IOS parameters in the CVA group significantly surpassed those in the control group. The ROC curve results for pre-BD IOS parameters and the improvement rate during the BD test showed that the combinations of pre-Z5%pred+△Z5% and pre-R5%pred+△R5% achieved the highest AUC value of 0.920 and 0.898, respectively. The AUC values of these combined parameters surpassed those of individual ones. CONCLUSIONS: This study highlights that children with CVA exhibit greater IOS parameters compared to healthy children. The changes in IOS parameters during the BD test provided valuable diagnostic information for CVA, and the combination of various parameters can help pediatricians accurately identify CVA in children.


Assuntos
Variante Tussígena da Asma , Oscilometria , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Albuterol , Broncodilatadores , Estudos de Casos e Controles , Tosse/etiologia , Tosse/diagnóstico , Variante Tussígena da Asma/diagnóstico , Variante Tussígena da Asma/fisiopatologia , Oscilometria/métodos , Testes de Função Respiratória/métodos , Curva ROC
17.
Blood Press ; 33(1): 2338208, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38591393

RESUMO

OBJECTIVE: Some brachial cuffs for oscillometric blood pressure (BP) measurement are claimed to cover a wide range of upper-arm circumferences; however, their validation is rarely conducted. Our aim was to compare oscillometric BP measurements obtained with a universal cuff with those obtained with an appropriately sized cuff. METHODS: We utilised the Microlife B6 Connect monitor, conducting oscillometric BP measurements in a random sequence with both a universal cuff (recommended for arm circumferences from 22 to 42 cm) and an appropriately sized cuff (medium for circumference 22-32 cm and large for 32-42 cm). We included 91 individuals with an arm circumference of 22-32 cm and 64 individuals with an arm circumference of 32-42 cm. RESULTS: For arm circumferences > 32 cm, systolic and diastolic BP measured with the universal cuff was higher than that measured with the large cuff (systolic 6.4 mmHg, 95% confidence interval [CI]). 3.9-8.8, diastolic 2.4 mmHg, 95%CI, 1.2-3.7, p < 0.001 for both). Overestimation of BP with the universal cuff was statistically significant after correcting for the sequence of measurements. No statistical difference was found between the universal cuff and medium cuff for circumferences in the 22-32 cm range. The bladder size in the universal cuff matched the dimensions of the medium-sized cuff; however, the cuff was larger. CONCLUSION: Overestimation of BP measured with a universal cuff in persons with large arm circumferences is clinically important. It poses the risk of unnecessary initiation or intensification of antihypertensive medication in persons using the universal cuff.


What is the context?Clinical guidelines recommend individualisation of the size of the cuff used for blood pressure measurement according to the circumference of the upper arm.Many blood pressure monitors are sold with a single "universal" cuff claimed to cover a wide range of upper arm sizes.We compared blood pressure obtained with the Microlife B6 Connect monitor and a "universal" cuff with the results obtained with individual sized cuffs (medium size for arm circumference between 22 and 32 cm and large size for arm circumference between 32 and 42 cm).What is new?In persons with large upper arm circumference is the systolic blood pressure 6.4 mmHg higher and the diastolic blood pressure 2.4 mmHg higher with the universal cuff than with the individual-sized large cuff.What is the impact?The universal cuff overestimates blood pressure in persons with large arm circumference.


Assuntos
Determinação da Pressão Arterial , Extremidade Superior , Humanos , Pressão Sanguínea/fisiologia , Determinação da Pressão Arterial/métodos , Oscilometria/métodos , Diástole , Monitores de Pressão Arterial
18.
J Formos Med Assoc ; 123(3): 366-373, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37689546

RESUMO

BACKGROUND: Little research has been conducted to evaluate the correlation between impulse oscillometry (IOS), Childhood Asthma Control Test (C-ACT), and Test for Respiratory and Asthma Control in Kids (TRACK). METHODS: This study was conducted at China Medical University Hospital between September 1, 2019, and March 31, 2021. Children aged 2-6 years who had been diagnosed with asthma with acute exacerbation were enrolled and followed-up until the end of the study. Correlations between the parameters of IOS, C-ACT and TRACK were assessed. The validity and reliability of TRACK were verified. RESULTS: A total of 114 children with asthma and acute exacerbations were recruited. Their mean age was 4.1 ± 1.1 years, and 60.5% were males. After a year of treatment, the change of R5-R20 from baseline 0.64 ± 0.38 kPa/L/s to 12th month 0.48 ± 0.2 kPa/L/s (p = 0.022). TRACK and C-ACT scores were significantly correlated during the observation period. R5-R20 in IOS at baseline and at the 12th month of follow-up as well as the change in IOS parameters were significantly associated with C-ACT (p = 0.003, 0.015, and 0.001, respectively). R5% and R5-R20 changes in IOS were associated with TRACK (p = 0.04 and 0.025, respectively). Sensitivity and specificity of TRACK were 80.8% (67.5-90.4) and 100% (94.1-100), respectively, with cut-off points >95 and AUC 93.8%. CONCLUSION: TRACK score appears to have a stronger association with the IOS parameter than C-ACT score. Our findings indicate that TRACK is a valid tool for assessing asthma control in preschool children.


Assuntos
Asma , Masculino , Pré-Escolar , Humanos , Criança , Feminino , Oscilometria , Reprodutibilidade dos Testes , Asma/diagnóstico , Testes de Função Respiratória , Sensibilidade e Especificidade , Volume Expiratório Forçado
19.
J Allergy Clin Immunol ; 151(2): 556-564, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36400177

RESUMO

BACKGROUND: Prior studies suggest that vitamin D may modify the effects of environmental exposures; however, none have investigated gestational vitamin D and cumulative tobacco smoke exposure (TSE) throughout pregnancy and early life. OBJECTIVES: This study investigated the effects of early life TSE on child lung function and the modulatory effects of gestational vitamin D on this association. METHODS: The VDAART (Vitamin D Antenatal Asthma Reduction Trial) recruited nonsmoking pregnant women and followed the mother-child pairs to age 6 years. TSE was assessed with questionnaires and plasma cotinine measurements in the mothers (10-18 and 32-38 gestational weeks) and children (1, 3, and 6 years). Cumulative TSE was calculated from the repeated cotinine measurements. 25-hydroxyvitamin D (25[OH]D) levels were measured at 10-18 and 32-38 gestational weeks. Lung function was assessed at 6 years with spirometry and impulse oscillometry. RESULTS: Of the 476 mother-child pairs, 205 (43%) had increased cotinine levels at ≥1 time point. Cumulative TSE was associated with decreased FEV1 (ß = -0.043 L, P = .018) and increased respiratory resistance at 5 Hz (R5; ß = 0.060 kPa/L/s, P = .002). This association persisted in subjects with insufficient (<30 ng/mL) 25(OH)D levels throughout pregnancy (ß = 0.077 kPa/L/s, P = .016 for R5) but not among those with sufficient levels throughout pregnancy. CONCLUSIONS: Cumulative TSE from pregnancy to childhood is associated with dose- and duration-dependent decreases in child lung function at 6 years even in the absence of reported maternal smoking. Gestational vitamin D may modulate this effect and have therapeutic potential for minimizing the adverse effect of TSE on lung throughout early life. RANDOMIZED TRIAL: Maternal Vitamin D Supplementation to Prevent Childhood Asthma (VDAART); clinicaltrials.gov identifier: NCT00920621.


Assuntos
Asma , Nicotiana , Feminino , Humanos , Gravidez , Criança , Cotinina , Vitamina D , Vitaminas , Asma/prevenção & controle , Pulmão
20.
Medicina (Kaunas) ; 60(3)2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38541172

RESUMO

Background and Objectives: Data on characteristics of asthma in children with sickle cell disease (SCD) is conflicting. Recently, the L-arginine pathway has gained attention in the pathogenesis of asthma and SCD. This study aimed to determine the distinctive clinical and laboratory features and the role of arginine metabolism in asthmatic children with SCD. Materials and Methods: A total of 52 children and adolescents with SCD, including 24 with asthma (SCD-A) and 28 without asthma (SCD-NA), and 40 healthy controls were included. A questionnaire, atopy tests, fractional exhaled nitric oxide (FeNO), and lung function tests were employed. Serum metabolites of the arginine pathway were measured. The results of the three groups were compared. Results: The demographic characteristics and atopy markers of the three groups were similar. FEV1%, FEV1/FVC, MMEF%, and total lung capacity (TLC%) values of SCD-A patients were not significantly different from the SCD-NA group, but they were significantly lower than the values measured in the controls. FeNO values greater than 35 ppb were present only in the SCD-A group. In impulse oscillometry, median resistance values at 5 Hz (R5)% were higher in both SCD subgroups than in healthy controls (p = 0.001). The (R5-20/R5)% values were higher in the SCD-A group (p = 0.028). Serum arginine levels and arginine bioavailability indices were significantly lower in the SCD-A group than in the SCD-NA group and healthy controls (p = 0.003 and p < 0.001). Conclusions: Asthma in children with SCD was not associated with atopy or low FEV1/FVC levels. However, lower arginine bioavailability and higher FeNO levels differentiated asthma in patients with SCD. High R5% and (R5-20/R5)% values indicated increased airway resistance in SCD, with a predominance of small airway disease in asthmatics.


Assuntos
Anemia Falciforme , Asma , Criança , Adolescente , Humanos , Adulto Jovem , Resistência das Vias Respiratórias , Teste da Fração de Óxido Nítrico Exalado , Disponibilidade Biológica , Oscilometria/métodos , Espirometria , Óxido Nítrico/metabolismo , Testes de Função Respiratória , Anemia Falciforme/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA