RESUMO
BACKGROUND: The purpose of this study was to compare the clinical outcome of surgery using robot-assisted posterior interbody fusion with that using freehand posterior interbody fusion in patients with degenerative spinal disease. METHODS: 78 participants with degenerative spinal disease were randomly allocated (1:1) to the minimally invasive (MIS), posterior lumbar interbody fusion (Robot-PLIF) or conventional, freehand, open-approach, posterior lumbar interbody fusion (Freehand-PLIF). RESULTS: The baseline-adjusted scores on the Oswestry Disability Index (ODI) in both groups at 1 year after surgery were not different (P = 0.688). However, the decrease in disc height at the proximal adjacent segment was significantly less in the Robot-PLIF group than in the Freehand-PLIF group (P = 0.039). CONCLUSION: One-year surgical outcomes including Visual Analog Scale, ODI and Short Form-36 did not differ between the two groups. The disc height in the proximal adjacent segment was significantly less decreased in the Robot-PLIF group than in the Freehand-PLIF group.
Assuntos
Vértebras Lombares/cirurgia , Parafusos Pediculares , Procedimentos Cirúrgicos Robóticos/métodos , Fusão Vertebral/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Procedimentos Cirúrgicos Robóticos/instrumentação , Fusão Vertebral/instrumentação , Estenose Espinal/diagnóstico por imagem , Estenose Espinal/cirurgia , Resultado do TratamentoRESUMO
PURPOSE: We prospectively assessed the early radiographic and clinical outcomes (minimum follow-up of 2 years) of robot-assisted pedicle screw fixation (Robot-PSF) and conventional freehand pedicle screw fixation (Conv-PSF). MATERIALS AND METHODS: Patients were randomly assigned to Robot-PSF (37 patients) or Conv-PSF (41 patients) for posterior interbody fusion surgery. The Robot-PSF group underwent minimally invasive pedicle screw fixation using a pre-planned robot-guided screw trajectory. The Conv-PSF underwent screw fixation using the freehand technique. Radiographic adjacent segment degeneration (ASD) was measured on plain radiographs, and clinical outcomes were measured using visual analogue scale (VAS) and Oswestry disability index (ODI) scores regularly after surgery. RESULTS: The two groups had similar values for radiographic ASD, including University California at Los Angeles grade, vertebral translation, angular motion, and loss of disc height (p=0.320). At final follow-up, both groups had experienced significant improvements in back VAS, leg VAS, and ODI scores after surgery (p<0.001), although inter-group differences were not significant for back VAS (p=0.876), leg VAS (p=0.429), and ODI scores (p=0.952). In the Conv-PSF group, revision surgery was required for two of the 25 patients (8%), compared to no patients in the Robot-PSF group. CONCLUSION: There were no significant differences in radiographic ASD and clinical outcomes between Robot-PSF and Conv-PSF. Thus, the advantages of robot-assisted surgery (accurate pedicle screw insertion and minimal facet joint violation) do not appear to be clinically significant.
Assuntos
Vértebras Lombares/cirurgia , Parafusos Pediculares , Radiografia , Robótica , Fusão Vertebral/métodos , Adulto , Idoso , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Medição da Dor , Estudos Prospectivos , Amplitude de Movimento Articular , Fusão Vertebral/instrumentação , Resultado do Tratamento , Escala Visual Analógica , Articulação ZigapofisáriaRESUMO
BACKGROUND CONTEXT: There have been conflicting results on the surgical outcome of lumbar fusion surgery using two different techniques: robot-assisted pedicle screw fixation and conventional freehand technique. In addition, there have been no studies about the biomechanical issues between both techniques. PURPOSE: This study aimed to investigate the biomechanical properties in terms of stress at adjacent segments using robot-assisted pedicle screw insertion technique (robot-assisted, minimally invasive posterior lumbar interbody fusion, Rom-PLIF) and freehand technique (conventional, freehand, open approach, posterior lumbar interbody fusion, Cop-PLIF) for instrumented lumbar fusion surgery. STUDY DESIGN: This is an additional post-hoc analysis for patient-specific finite element (FE) model. PATIENT SAMPLE: The sample is composed of patients with degenerative lumbar disease. OUTCOME MEASURES: Intradiscal pressure and facet contact force are the outcome measures. METHODS: Patients were randomly assigned to undergo an instrumented PLIF procedure using a Rom-PLIF (37 patients) or a Cop-PLIF (41), respectively. Five patients in each group were selected using a simple random sampling method after operation, and 10 preoperative and postoperative lumbar spines were modeled from preoperative high-resolution computed tomography of 10 patients using the same method for a validated lumbar spine model. Under four pure moments of 7.5 Nm, the changes in intradiscal pressure and facet joint contact force at the proximal adjacent segment following fusion surgery were analyzed and compared with preoperative states. RESULTS: The representativeness of random samples was verified. Both groups showed significant increases in postoperative intradiscal pressure at the proximal adjacent segment under four moments, compared with the preoperative state. The Cop-PLIF models demonstrated significantly higher percent increments of intradiscal pressure at proximal adjacent segments under extension, lateral bending, and torsion moments than the Rom-PLIF models (p=.032, p=.008, and p=.016, respectively). Furthermore, the percent increment of facet contact force was significantly higher in the Cop-PLIF models under extension and torsion moments than in the Rom-PLIF models (p=.016 under both extension and torsion moments). CONCLUSIONS: The present study showed the clinical application of subject-specific FE analysis in the spine. Even though there was biomechanical superiority of the robot-assisted insertions in terms of alleviation of stress increments at adjacent segments after fusion, cautious interpretation is needed because of the small sample size.
Assuntos
Parafusos Pediculares/efeitos adversos , Robótica/métodos , Fusão Vertebral/métodos , Adulto , Fenômenos Biomecânicos , Feminino , Análise de Elementos Finitos , Humanos , Vértebras Lombares/cirurgia , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Fusão Vertebral/efeitos adversos , Fusão Vertebral/instrumentaçãoRESUMO
BACKGROUND: The purpose of this study was to compare the accuracy and safety of an instrumented posterior lumbar interbody fusion (PLIF) using a robot-assisted minimally invasive (Robot-PLIF) or a conventional open approach (Freehand-PLIF). METHODS: Patients undergoing an instrumented PLIF were randomly assigned to be treated using a Robot-PLIF (37 patients) and a Freehand-PLIF (41 patients). RESULTS: For intrapedicular accuracy, there was no significant difference between the groups (P = 0.534). For proximal facet joint accuracy, none of the 74 screws in the Robot-PLIF group violated the proximal facet joint, while 13 of 82 in the Freehand-PLIF group violated the proximal facet joint (P < 0.001). The average distance of the screws from the facets was 5.2 ± 2.1 mm and 2.7 ± 1.6 mm in the Robot-PLIF and Freehand-PLIF groups, respectively (P < 0.001). CONCLUSION: Robotic-assisted pedicle screw placement was associated with fewer proximal facet joint violations and better convergence orientations.