Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 903
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
RNA ; 30(3): 308-324, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38190635

RESUMO

m6A has different stoichiometry at different positions in different mRNAs. However, the exact stoichiometry of m6A is difficult to measure. Here, we describe SCARPET (site-specific cleavage and radioactive-labeling followed by purification, exonuclease digestion, and thin-layer chromatography), a simple and streamlined biochemical assay for quantifying m6A at any specific site in any mRNA. SCARPET involves a site-specific cleavage of mRNA immediately 5' of an adenosine site in an mRNA. This site is radiolabeled with 32P, and after a series of steps to purify the RNA and to remove nonspecific signals, the nucleotide is resolved by TLC to visualize A and m6A at this site. Quantification of these spots reveals the m6A stoichiometry at the site of interest. SCARPET can be applied to poly(A)-enriched RNA, or preferably purified mRNA, which produces more accurate m6A stoichiometry measurements. We show that sample processing steps of SCARPET can be performed in a single day, and results in a specific and accurate measurement of m6A stoichiometry at specific sites in mRNA. Using SCARPET, we measure exact m6A stoichiometries in specific mRNAs and show that Zika genomic RNA lacks m6A at previously mapped sites. SCARPET will be useful for testing specific sites for their m6A stoichiometry and to assess how m6A stoichiometry changes in different conditions and cellular contexts.


Assuntos
Infecção por Zika virus , Zika virus , Humanos , Adenosina/genética , RNA , RNA Mensageiro/metabolismo , Nucleotídeos , Processamento Pós-Transcricional do RNA , Zika virus/genética
2.
J Biol Chem ; 299(3): 102923, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36681125

RESUMO

Pancreatic ductal adenocarcinoma (PDAC) is one of the most common causes of cancer-related deaths worldwide, accounting for 90% of primary pancreatic tumors with an average 5-year survival rate of less than 10%. PDAC exhibits aggressive biology, which, together with late detection, results in most PDAC patients presenting with unresectable, locally advanced, or metastatic disease. In-depth lipid profiling and screening of potential biomarkers currently appear to be a promising approach for early detection of PDAC or other cancers. Here, we isolated and characterized complex glycosphingolipids (GSL) from normal and tumor pancreatic tissues of patients with PDAC using a combination of TLC, chemical staining, carbohydrate-recognized ligand-binding assay, and LC/ESI-MS2. The major neutral GSL identified were GSL with the terminal blood groups A, B, H, Lea, Leb, Lex, Ley, P1, and PX2 determinants together with globo- (Gb3 and Gb4) and neolacto-series GSL (nLc4 and nLc6). We also revealed that the neutral GSL profiles and their relative amounts differ between normal and tumor tissues. Additionally, the normal and tumor pancreatic tissues differ in type 1/2 core chains. Sulfatides and GM3 gangliosides were the predominant acidic GSL along with the minor sialyl-nLc4/nLc6 and sialyl-Lea/Lex. The comprehensive analysis of GSL in human PDAC tissues extends the GSL coverage and provides an important platform for further studies of GSL alterations; therefore, it could contribute to the development of new biomarkers and therapeutic approaches.


Assuntos
Glicoesfingolipídeos , Neoplasias Pancreáticas , Humanos , Cromatografia Líquida , Cromatografia em Camada Fina , Gangliosídeos/química , Glicoesfingolipídeos/análise , Glicoesfingolipídeos/química , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/fisiopatologia , Sulfoglicoesfingolipídeos/química , Carcinoma Ductal Pancreático/diagnóstico , Carcinoma Ductal Pancreático/fisiopatologia , Espectrometria de Massas em Tandem , Biomarcadores Tumorais/metabolismo
3.
Annu Rev Biomed Eng ; 25: 281-309, 2023 06 08.
Artigo em Inglês | MEDLINE | ID: mdl-37068764

RESUMO

Lipids are essential cellular components forming membranes, serving as energy reserves, and acting as chemical messengers. Dysfunction in lipid metabolism and signaling is associated with a wide range of diseases including cancer and autoimmunity. Heterogeneity in cell behavior including lipid signaling is increasingly recognized as a driver of disease and drug resistance. This diversity in cellular responses as well as the roles of lipids in health and disease drive the need to quantify lipids within single cells. Single-cell lipid assays are challenging due to the small size of cells (∼1 pL) and the large numbers of lipid species present at concentrations spanning orders of magnitude. A growing number of methodologies enable assay of large numbers of lipid analytes, perform high-resolution spatial measurements, or permit highly sensitive lipid assays in single cells. Covered in this review are mass spectrometry, Raman imaging, and fluorescence-based assays including microscopy and microseparations.


Assuntos
Lipídeos , Transdução de Sinais , Humanos , Lipídeos/análise , Lipídeos/química , Espectrometria de Massas/métodos , Metabolismo dos Lipídeos
4.
Anal Bioanal Chem ; 416(3): 715-731, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36988684

RESUMO

Current strategies for non-target food screening focus mainly on known hazardous chemicals (adulterants, residues, contaminants, packaging migrants, etc.) instead of bioactive constituents in general and exclude the biological effect detection. To widen the perspective, a more proactive non-target effect-directed strategy is introduced to complement food safety in order to detect not only known but also unknown bioactive compounds. The developed 10-dimensional hyphenation included on-surface digestion (1D), planar chromatographic separation (2D), visualization using white light (3D), UV light (4D), fluorescence light (5D), effect-directed assay analysis (6D), heart-cut zone elution to an orthogonal reversed phase column chromatography including online desalting (7D) with subsequent diode array detection (8D), high-resolution mass spectrometry (9D), and fragmentation (10D). Metabolism, i.e., intestinal digestion of each sample, was simulated and integrated on the same adsorbent surface to study any changes in the compound profiles. As proof of principle, nine convenience tomato products and a freshly prepared tomato soup were screened via five different planar assays in a non-targeted mode. Non-digested and digested samples were compared side by side. In their effect-directed profiles, 14 bioactive compounds from classes of lipids, plant hormones, spices, and pesticides were identified. In particular, bioactive compounds coming from the lipid class were increased by gastrointestinal digestion, while spices and pesticides remained unaffected. With regard to food safety, the determination of the two dinitrophenol herbicides dinoterb and dinoseb in highly processed tomato products should be given special attention. The hyphenation covered a broad analyte spectrum and showed robust and reliable results.


Assuntos
Praguicidas , Solanum lycopersicum , Cromatografia em Camada Fina/métodos , Espectrometria de Massas , Digestão , Cromatografia Líquida de Alta Pressão/métodos
5.
J Sep Sci ; 47(12): e2400099, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38937914

RESUMO

The chromatographic behavior of the selected compounds was studied under conditions of hydrophilic interaction liquid chromatography (HILIC). The effect of mobile phase composition on the retention in different chromatographic systems was systematically examined using high-performance thin-layer chromatography. The sorbents of different polarity and adsorption characteristics were selected and mixtures of water and organic solvents of various compositions, from pure water to pure organic solvent were used as mobile phases. Increasing the amount of water in the mobile phase leads to a conversion of the separation mechanism, and the retention curves have a characteristic "U" shape. The conversion between the adsorption and partition mechanisms is most likely continuous and depends on the chemical nature of separated substances, the stationary phase as well as on organic component of the mobile phase. Silica gel can be considered the most suitable stationary phase for the systematic investigation of the chromatographic behavior of the test compounds, whereas acetonitrile was the most suitable solvent. The obtained results contribute to the understanding of the dominant separation mechanism, the type, and the intensity of the interactions between separated substances with both stationary and mobile phases. Besides, the lipophilicity parameters obtained under HILIC conditions were evaluated and correlated with the calculated values.


Assuntos
Interações Hidrofóbicas e Hidrofílicas , Cromatografia em Camada Fina , Solventes/química , Adsorção , Cromatografia Líquida
6.
Biomed Chromatogr ; 38(7): e5867, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38558037

RESUMO

Fourteen donepezil-like acetylcholinesterase (AChE) inhibitors from our library were analyzed using reversed-phase thin-layer chromatography to assess their lipophilicity and blood-brain barrier permeability. Compounds possessed N-benzylpiperidine and N,N-diarylpiperazine moieties connected via a short carboxamide or amine linker. Retention parameters RM 0, b, and C0 were considered as the measures of lipophilicity. Besides, logD of the investigated compounds was determined chromatographically using standard compounds with known logPow and logD values at pH 11. Experimentally obtained lipophilicity parameters correlated well with in silico generated results, and the effect of the nature of the linker between two pharmacophores and substituents on the arylpiperazine part of the molecule was observed. As a result of drug-likeness analysis, both Lipinski's rule of five and Veber's rule parameters were determined, suggesting that examined compounds could be potential candidates for further drug development. Principal component analysis was performed to obtain an insight into a grouping of compounds based on calculated structural descriptors, experimentally obtained values of lipophilicity, and AChE inhibitory activity.


Assuntos
Inibidores da Colinesterase , Cromatografia de Fase Reversa , Donepezila , Interações Hidrofóbicas e Hidrofílicas , Piperidinas , Cromatografia em Camada Fina/métodos , Inibidores da Colinesterase/química , Inibidores da Colinesterase/farmacologia , Cromatografia de Fase Reversa/métodos , Donepezila/química , Donepezila/farmacologia , Piperidinas/química , Indanos/química , Barreira Hematoencefálica/metabolismo , Análise de Componente Principal
7.
Phytochem Anal ; 2024 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-39193915

RESUMO

INTRODUCTION: Kratom (leaves from Mitragyna speciosa Korth.; Rubiaceae) is a herbal medicine known for its analgesic properties and psychoactive effects. Kratom in Thailand is currently legal; however, it is prohibited in some countries and considered a narcotic plant. OBJECTIVE: Our aim was to establish a reliable, simple, and rapid method for quantifying mitragynine in Kratom leaves and related products through a combination of high-performance thin-layer chromatography (HPTLC) and densitometry. METHODOLOGY: A densitometric HPTLC method was developed and validated in terms of specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), accuracy, precision, and robustness. The fingerprints of kratom leaves, Mitragyna spp., and related products were constructed. RESULTS: For HPTLC, samples were applied to silica gel 60 F254 plates, and the mobile phase comprised n-hexane, ethyl acetate, and triethylamine (1:1:0.15, v/v/v). Densitometric detection was carried out under ultraviolet light at a wavelength of 226 nm. The validated method exhibited a range of 14.31-143.10 µg/mL, yielding a correlation coefficient of 0.9993. Spiked recovery rates were within a range of 98.3%-100.9%, and the LOD and LOQ were 3.80 and 11.53 µg/mL, respectively. Kratom samples were analyzed with the developed method, and the correlation coefficient was 0.9641, compared to the high-performance liquid chromatography-diode-array detection (HPLC-DAD) method. The HPTLC fingerprints displayed a distinctive pattern, facilitating discrimination among different plant parts and Mitragyna spp. CONCLUSION: The established method offers the advantages of simplicity, ease of use, and speed of analysis, serving as a practical alternative for mitragynine quantification in kratom leaf and its related products.

8.
Molecules ; 29(8)2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38675702

RESUMO

The goal of this study was to apply the principles of analytical quality by design (AQbD) to the analytical method for determining the radiochemical purity (PQR) of the radiopharmaceutical sodium iodide 131I oral solution, utilizing thin-layer chromatography (TLC) with a radio-TLC scanner, which also enables the evaluation of product quality. For AQbD, the analytical target profile (ATP), critical quality attributes (CQA), risk management, and the method operable design region (MODR) were defined through response surface methodology to optimize the method using MINITAB® 19 software. This study encompassed the establishment of a control strategy and the validation of the method, including the assessment of selectivity, linearity, precision, robustness, detection limit, quantification limit, range, and the stability of the sample solution. Under the experimental conditions, the method parameters of the TLC scanner were experimentally demonstrated and optimized with an injection volume of 3 µL, a radioactive concentration of 10 mCi/mL, and a carrier volume of 40 µL. Statistical analysis confirmed the method's selectivity for the 131I iodide band Rf of 0.8, a radiochemical impurity IO3- Rf of 0.6, a linearity from 6.0 to 22.0 mCi/mL, and an intermediate precision with a global relative standard deviation (RSD) of 0.624%. The method also exhibited robustness, with a global RSD of 0.101%, a detection limit of 0.09 mCi/mL, and a quantification limit of 0.53 Ci/mL, meeting the prescribed range and displaying stability over time (at 0, 2, and 20 h) with a global RSD of 0.362%, resulting in consistent outcomes. The development of a method based on AQbD facilitated the creation of a design space and an operational space, with comprehensive knowledge of the method's characteristics and limitations. Additionally, throughout all operations, compliance with the acceptance criteria was verified. The method's validity was confirmed under the established conditions, making it suitable for use in the manufacturing process of sodium iodide 131I and application in nuclear medicine services.


Assuntos
Radioisótopos do Iodo , Compostos Radiofarmacêuticos , Iodeto de Sódio , Cromatografia em Camada Fina/métodos , Compostos Radiofarmacêuticos/química , Compostos Radiofarmacêuticos/análise , Radioisótopos do Iodo/análise , Iodeto de Sódio/química , Administração Oral , Reprodutibilidade dos Testes
9.
NMR Biomed ; 36(8): e4932, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36940044

RESUMO

Nonalcoholic fatty liver disease (NAFLD) is the leading cause of chronic liver disease worldwide. Liver biopsy remains the gold standard for diagnosis and staging of disease. There is a clinical need for noninvasive diagnostic tools for risk stratification, follow-up, and monitoring treatment response that are currently lacking, as well as preclinical models that recapitulate the etiology of the human condition. We have characterized the progression of NAFLD in eNOS-/- mice fed a high fat diet (HFD) using noninvasive Dixon-based magnetic resonance imaging and single voxel STEAM spectroscopy-based protocols to measure liver fat fraction at 3 T. After 8 weeks of diet intervention, eNOS-/- mice exhibited significant accumulation of intra-abdominal and liver fat compared with control mice. Liver fat fraction measured by 1 H-MRS in vivo showed a good correlation with the NAFLD activity score measured by histology. Treatment of HFD-fed NOS3-/- mice with metformin showed significantly reduced liver fat fraction and altered hepatic lipidomic profile compared with untreated mice. Our results show the potential of in vivo liver MRI and 1 H-MRS to noninvasively diagnose and stage the progression of NAFLD and to monitor treatment response in an eNOS-/- murine model that represents the classic NAFLD phenotype associated with metabolic syndrome.


Assuntos
Metformina , Hepatopatia Gordurosa não Alcoólica , Humanos , Animais , Camundongos , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/tratamento farmacológico , Hepatopatia Gordurosa não Alcoólica/metabolismo , Ácidos Graxos/metabolismo , Metformina/farmacologia , Metformina/uso terapêutico , Modelos Animais de Doenças , Fígado/metabolismo , Espectroscopia de Ressonância Magnética/métodos , Camundongos Endogâmicos C57BL
10.
Chemistry ; 29(39): e202300829, 2023 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-37132089

RESUMO

Thin layer chromatography (TLC) is widely used to confirm the formation of the target compound in chemical synthesis. The key issue in TLC is spot identification as it primarily relies on retention factors. Coupling of TLC with surface-enhanced Raman spectroscopy (SERS), which gives direct molecular information, is an appropriate choice, to overcome this challenge. However, interference from the stationary phase and impurities on the nanoparticles added for SERS measurements significantly degrades TLC-SERS efficiency. It was found that freezing effectively eliminates such interferences and dramatically improves the performance of TLC-SERS. In this study, TLC-freeze SERS is applied to the monitoring of four chemically important reactions. The proposed method can identify the product and side-products of similar structures, detect compounds with high sensitivity, and provide information of quantities that allows the reliable determination of the reaction time based on kinetic analysis.

11.
Prostaglandins Other Lipid Mediat ; 168: 106751, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37295489

RESUMO

Sphingolipidoses are a group of metabolic diseases in which lysosomal hydrolases dysfunction disrupt normal sphingolipids' metabolism, leading to excess accumulation in cellular compartments and excretion in urine. These pathologies represent a significant burden among Moroccan population, for which an easy access to enzymatic assays and genetic tests is not guaranteed. Parallel analytical methods thus have to be developed for preliminary screening. In this study, 107 patients were addressed to the metabolic platform of the Marrakesh Faculty of Medicine for diagnosis confirmation. Thin-Layer Chromatography was used as a first step to perform chemical profiling of the patients' urinary lipids, allowing 36% of the patients to be efficiently oriented towards the adequate enzymatic assay. UPLC-MS/MS analyses of urinary sulfatides excreted in urines patient had been used to control the reliability of TLC analysis and to obtain more accurate information related to the sulfatides isoforms. This analytical process combining TLC with UPLC-MS/MS has enabled rapid and appropriate patient management in a reduced time and with reduced resources.


Assuntos
Esfingolipidoses , Sulfoglicoesfingolipídeos , Humanos , Cromatografia Líquida/métodos , Marrocos , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/métodos , Esfingolipidoses/diagnóstico
12.
Anal Bioanal Chem ; 415(21): 5193-5204, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37458782

RESUMO

The Arxula yeast bisphenol screen (A-YBS) utilizes the bioluminescent Arxula adeninivorans yeast-based reporter cells for tailored analysis of bisphenols, one of the major endocrine-disrupting compound groups. For the first time, this bioreporter has been applied on the high-performance thin-layer chromatography (HPTLC) adsorbent surface to develop a respective planar bioluminescence bioassay (pA-YBS). The goal was to combine the advantages of HPTLC with a more selective bioassay detection for bisphenols. The performance of this pA-YBS bioluminescence bioassay was demonstrated by calculating the half-maximal effective concentration (EC50) of bisphenols compared to references. The EC50 ranged from 267 pg/band for bisphenol Z and 322 pg/band for bisphenol A (BPA) to > 1 ng/band for other bisphenols (BPC, BPE, BPF, and BPS) and references (17ß-estradiol and 17α-ethinylestradiol). The EC50 value of BPA was three times more sensitive in signal detection than that of 17ß-estradiol. The visual or videodensitometric limit of detection of BPA was about 200 pg/zone. The higher signal intensity and sensitivity for BPA confirmed the tailored bioassay selectivity compared to the existing estrogen screen bioassay. It worked on different types of HPTLC silica gel plates. This HPTLC-UV/Vis/FLD-pA-YBS bioluminescence bioassay method was used to analyze complex mixtures such as six tin can migrates, five thermal papers, and eleven botanicals. The detected estrogenic compound zones in the tin can migrates were successfully verified via the duplex planar yeast antagonist estrogen screen (pYAES) bioassay. The two bisphenols A and S were identified in one out of five thermal papers and confirmed with high-resolution mass spectrometry. No bisphenols were detected in the botanicals investigated via the pA-YBS bioluminescence bioassay. However, the botanicals proved to contain phytoestrogens as detected via the pYAES bioassay, which confirmed the tailored bioassay selectivity. This HPTLC-UV/Vis/FLD-pA-YBS bioluminescence bioassay is suited for cost-efficient analysis of BPA in complex samples, with no need for sterile conditions due to the fast workflow.


Assuntos
Saccharomyces cerevisiae , Estanho , Saccharomyces cerevisiae/química , Estrogênios/análise , Estradiol/análise , Compostos Benzidrílicos/análise , Bioensaio
13.
J Sep Sci ; 46(6): e2200991, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36641601

RESUMO

A simple and rapid high-performance thin-layer chromatographic method for quantification of gallic acid and ellagic acid in dried fruits of Terminalia chebula, Phyllanthus emblica, and Quercus infectoria has been developed. The chromatographic development was carried out on precoated silica gel 60 F254 plates in a mixture of toluene:ethyl acetate:chloroform:formic acid (4:8:1:3 v/v/v/v). The plate was scanned densitometrically at a wavelength of 280 nm. The retention factor value of gallic acid and ellagic acid was found to be 0.63 ± 0.2 and 0.53 ± 0.1, respectively. The developed method was validated in terms of linearity, precision, accuracy, sensitivity, robustness, specificity and stability as per the international conference of harmonization guidelines. The method showed good linear relationship over a range of 100-600 ng/band (gallic acid) and 100-500 ng/band (ellagic acid) with a regression coefficient (r2 ) of 0.997 (gallic acid) and 0.996 (ellagic acid). The method showed high accuracy (99.65%-100.85%). The percentage relative standard deviation of intra-day and inter-day precision studies was not more than 2%. The method is highly robust and has displayed high specificity. The developed method is new, simple, and accurate and can be successfully employed in routine analysis of raw materials and formulations containing gallic acid and ellagic acid.


Assuntos
Phyllanthus emblica , Quercus , Terminalia , Ácido Gálico/análise , Ácido Elágico , Terminalia/química , Frutas/química , Cromatografia em Camada Fina/métodos
14.
J Sep Sci ; 46(3): e2200708, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36494714

RESUMO

Solvent system selection is a crucial and the most time-consuming step for successful countercurrent chromatography separation. A thin-layer chromatography-based generally useful estimate of solvent systems method has been developed to simplify the solvent system selection. We herein utilized the method to select a solvent system for off-line two-dimensional countercurrent chromatography to separate chemical compositions from a complex fraction of the Siraitia grosvenorii root extract. The first-dimensional countercurrent separation using chloroform/methanol/water (10:5.5:4.5, v/v/v) yielded four compounds with high purity and three mixture fractions (Fr I, III, and VII). The second-dimensional countercurrent separation conducted on Fr I, III, and VII using the hexane/ethyl acetate/methanol/water (4:6:6:4, 3:7:3:7, v/v/v) and chloroform/methanol/water (10:9:6, v/v/v) solvent systems, respectively, produced another four compounds. Four triterpenoids and four lignans were finally isolated, including two novel compounds. Hence, the generally useful estimate of solvent systems method is a feasible and efficient approach for selecting an applicable solvent system for separating complex samples. In addition, the off-line two-dimensional countercurrent chromatography method can improve both the peak resolution and the capacity of countercurrent chromatography.


Assuntos
Distribuição Contracorrente , Extratos Vegetais , Solventes/química , Distribuição Contracorrente/métodos , Extratos Vegetais/química , Metanol , Clorofórmio/química , Água/química , Cromatografia Líquida de Alta Pressão/métodos
15.
J Sep Sci ; 46(4): e2200951, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36524974

RESUMO

Gastrointestinal tract disorders constitute a heavy burden to healthcare providers. To eradicate Helicobacter pylori infection, different triple therapy protocols have been proposed. Among which are combinations of proton pump inhibitors (e.g., omeprazole), histamine-2 receptor antagonists (e.g., famotidine), along with antibiotics (e.g., amoxicillin). In this work, a sensitive and accurate high-performance thin-layer chromatographic method was developed for the simultaneous determination of amoxicillin, metronidazole, and famotidine in bulk powder and laboratory-prepared combined-tablet mixtures. Complete separation of the cited compounds was achieved using pre-coated silica gel plates with a mixture of methanol:chloroform:toluene:water:glacial acetic acid (5:2:1.5:0.5:0.1 v/v/v/v/v) as the mobile phase. The method was fully validated as per the international conference of harmonization guidelines. Good linearity, a correlation coefficient of 0.9991, was obtained in the concentration ranges 0.1-1.6 µg/band (amoxicillin), 0.1-0.9 µg/band (metronidazole), and 0.1-0.9 µg/band (famotidine). Since the method allowed the determination of the three compounds in combined tablets with a high degree of selectivity, accuracy, precision, with cost-effectiveness, it could be used for regular quality control. Moreover, the applicability of the proposed method was extended to the determination of the ternary mixture in simulated gastric juice. Method greenness was assessed using different green metrics.


Assuntos
Infecções por Helicobacter , Helicobacter pylori , Humanos , Famotidina/análise , Metronidazol , Amoxicilina , Comprimidos , Suco Gástrico , Cromatografia em Camada Fina/métodos
16.
J Sep Sci ; 46(16): e2300160, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37269050

RESUMO

Siegesbeckiae Herba, a traditional Chinese medicine, originates from Siegesbeckia orientalis, S. glabrescens, and S. pubescens in the Pharmacopoeia of the People's Republic of China. However, accurate identification of decoction pieces from the three plants remains a challenge. In this study, 26 batches of Siegesbeckiae Herba were identified by deoxyribonucleic acid barcoding, and their chemical compositions were determined using ultra-performance liquid chromatography-electrospray ionization-quadrupole time of flight-mass spectrometry. The results showed that the internal transcribed spacer 2 and internal transcribed spacer 1-5.8 S- internal transcribed spacer 2 sequences could distinguish three species. In total, 48 compounds were identified including 12 marker compounds screened for three species using the partial least square discriminant analysis. Among these, two diterpenoids 16-O-malonylkirenol and 15-O-malonylkirenol, and a novel diterpenoid 15,16-di-O-malonylkirenol were isolated and identified. A convenient method for the identification of Siegesbeckiae Herba was established using kirenol and 16-O-acetlydarutoside as control standards by thin-layer chromatography. Unexpectedly, none of the batches of S. orientalis contained kirenol, which did not meet the quality standards of Siegesbeckiae Herba, suggesting that the rationality of kirenol as a quality marker for S. orientalis should be further investigated. The results of this study will contribute to the quality control of Siegesbeckiae Herba.


Assuntos
Medicamentos de Ervas Chinesas , Espectrometria de Massas por Ionização por Electrospray , Humanos , Espectrometria de Massas por Ionização por Electrospray/métodos , Medicamentos de Ervas Chinesas/química , Cromatografia Líquida/métodos , DNA , Cromatografia Líquida de Alta Pressão/métodos
17.
J Sep Sci ; 46(18): e2300071, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36965178

RESUMO

High-performance thin-layer chromatography has favorable properties for high-throughput separations with a high matrix tolerance. Sample preparation, however, is sometimes required to control specific matrix interferences and to enhance the detectability of target compounds. Trends in contemporary applications have shifted from absorbance and fluorescence detection to methods employing bioassays and mass spectrometry. Traditional methods (shake-flask, heat at reflux, Soxhlet, and hydrodistillation) are being challenged by automated instrumental approaches (ultrasound-assisted and microwave-assisted solvent extraction, pressurized liquid extraction, and supercritical fluid extraction) and the quick, easy cheap, efficient, rugged, and safe extraction method for faster and streamlined sample processing. Liquid-liquid extraction remains the most widely used approach for sample clean-up with increasing competition from solid-phase extraction. On-layer sample, clean-up by planar solid-phase extraction is increasingly used for complex samples and in combination with heart-cut multimodal systems. The automated spray-on sample applicator, the elution head interface, biological detection of target and non-target compounds, and straightforward mass spectrometric detection are highlighted as the main factors directing current interest toward faster and simpler sample workflows, analysis of more complex samples, and the determination of minor contaminants requiring high concentration factors.


Assuntos
Cromatografia com Fluido Supercrítico , Extração em Fase Sólida , Espectrometria de Massas , Extração Líquido-Líquido , Manejo de Espécimes , Cromatografia Líquida de Alta Pressão/métodos
18.
J Sep Sci ; 46(4): e2200754, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36567309

RESUMO

Canagliflozin is an oral hypoglycemic drug recently formulated in combination with a biguanide, metformin hydrochloride, for improving its hypoglycemic action. Canagliflozin has one reported major degradation product, also metformin hydrochloride has one reported major degradation product, cyanoguanidine, and has a potential toxic impurity, melamine, that is reported to cause crystalluria that causes chronic kidney inflammation and nephrolithiasis leading to a renal failure. As per International Conference of Harmonization guidelines; a drug degradation product is classified as a type of drug impurities. Toxicity profiles of canagliflozin and metformin major degradation products were studied where in silico data disclosed toxicity too; the development of a specific chromatographic thin layer chromatographic assay was a must for quantification of such toxic related components along with the drugs in laboratory-prepared mixtures as a superior study. The proposed method was validated as per the International Conference of Harmonization and applied for the assay of Vokanamet tablets. The separation was achieved using acetone:ethyl acetate:acetic acid (8:2:0.2, by volume) as scanning eluted bands at 205 nm. For minimal environmental impact; greenness profile appraisal of the proposed assay was performed by three greenness assessment approaches; analytical Eco-Scale, Green Analytical Procedure Index, and Greenness metric approaches.


Assuntos
Metformina , Metformina/análise , Canagliflozina/análise , Reprodutibilidade dos Testes , Hipoglicemiantes/análise , Cromatografia em Camada Fina/métodos , Cromatografia Líquida de Alta Pressão/métodos
19.
J Sep Sci ; 46(21): e2300582, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37675810

RESUMO

The extraction of berberine was carried out from Berberis vulgaris, Berberis aquifolium, and Hydrastis canadensis plants using ethanol and water (70:30, v/v). The extracted berberine was characterized by ultraviolet-visible and Fourier-transform infrared spectroscopy. The purity of berberine was ascertained by thin-layer chromatography using n-propanol-formic acid-water (95:1:4) and (90:1:9) solvents. hRf values were in the range of 44-49 with compact spots (diameter 0.2-0.4 cm). HPLC was carried out using ammonium acetate buffer and acetonitrile in gradient mode with Zodiac (4.6 × 150 mm, 3 µm) column. The flow rate was 1.0 mL/min and detection was at 220 nm. The values of separation and resolution factors of the standard and the extracted berberine were in the range of 1.13-1.16 and 1.40-1.71, respectively. A comparison has shown that both thin-layer chromatography and high-performance liquid chromatography (HPLC) methods found applications in different situations and requirements. The extracted berberine samples were used to treat Leishmaniosis and the results showed better activity of berberine in comparison to the standard drug Amphotericin B. Briefly, the reported research is a novel and may be used to extract berberine from plants, separation and identification of berberine by thin layer chromatography and HPLC and to treat Leishmaniosis.


Assuntos
Berberina , Berberina/química , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia em Camada Fina/métodos , Solventes/análise , Água
20.
J Sep Sci ; 46(21): e2300198, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37675829

RESUMO

The methodologies of asphaltenes-containing petroleum materials: saturated, aromatics, resins, asphaltenes group-type composition analysis are performed with the use of column adsorption-desorption or thin layer chromatography (TLC)-flame ionization detection under normal phase conditions with silica gel as the adsorbent. In a three-step procedure, the TLC chromatogram is developed within a decreasing distance by the mobile phase with increasing elution strength (polarity). The n-alkane used in the first step does not dissolve asphaltenes, which leads to the occlusion effect and an underestimation of the percentage of saturated hydrocarbons. In this article, the reverse order of the subsequent elution steps was proposed: the solvent polarity is simultaneously reduced and the chromatogram development distance is increased in the order dichloromethane:methanol 95:5 v/v, 3 cm; toluene, 6 cm; and n-hexane, 10 cm. It was also intentional to reduce the weight of the applied sample to 5 µg for bitumen and 2 µg for asphaltene purity testing. It should be the rule that in stepwise TLC chromatogram development, the first mobile phase is a good solvent for all testing components. The IP 469 procedure should be corrected.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA