Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Neurosurg Case Lessons ; 1(4)2021 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-36131585

RESUMO

BACKGROUND: Cervical arterial tortuosity is not uncommon in patients with spontaneous carotid artery dissections (CADs), but the tortuosity often precludes endovascular stent reconstruction. The authors report 2 cases of emergency recanalization of a carotid tonsillar loop dissection using a Pipeline embolization device (PED). OBSERVATIONS: Two patients presented with symptomatic CAD involving tonsillar looping of the cervical internal carotid artery (ICA). Although the tonsillar loop prevented navigation of the carotid and peripheral stent delivery system, a PED was easily navigated and successfully deployed, resulting in successful recanalization of a looped ICA. LESSONS: Emergency recanalization of a cervical CAD using a PED is a feasible alternative for treating a cervical CAD associated with tonsillar loops.

2.
World Neurosurg ; 116: e903-e912, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29852307

RESUMO

This article has been retracted: please see Elsevier Policy on Article Withdrawal (https://www.elsevier.com/about/our-business/policies/article-withdrawal). This article has been retracted at the request of of the Editor-in-Chief because this article has included both figures and data from patients that were cared for by Dr. Malek at the Cerebrovascular Hemodynamics laboratory in the Department of Neurosurgery, at Tufts Medical Center. As we understand, Dr. Gao did not have clinical privileges and played no clinical role in the care of Dr. Malek's patients while at Tufts Medical Center.


Assuntos
Falso Aneurisma/cirurgia , Artéria Carótida Interna/cirurgia , Gerenciamento Clínico , Procedimentos Endovasculares/métodos , Aneurisma Intracraniano/cirurgia , Stents , Adulto , Idoso , Idoso de 80 Anos ou mais , Falso Aneurisma/diagnóstico por imagem , Artéria Carótida Interna/anormalidades , Artéria Carótida Interna/diagnóstico por imagem , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
3.
J Clin Neurosci ; 21(7): 1141-7, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24642024

RESUMO

Although advances in endovascular techniques have permitted reconstruction of intimal dissections and related pseudoaneurysms of the extracranial cervical internal carotid artery, highly tortuous tonsillar loop anatomic variants still pose an obstacle to conventional extracranial self-expanding carotid stents. During a 12 year period, nine of 48 cases with cervical carotid dissections were associated with a tonsillar loop. Five patients required endovascular treatment, which was performed using a microcatheter-based technique with the low-profile Enterprise vascular reconstruction device (Codman Neurovascular, Raynham, MA, USA). Technical, radiographic, and clinical outcomes were analyzed for each patient. Dissection etiology was spontaneous in three patients, iatrogenic in one, and traumatic in one. Four near-occlusive tonsillar loop dissections were successfully recanalized during the acute phase. Dissection-related stenosis improved from 90±22% to 31±13%, with tandem stents needed in three instances to seal the inflow zone. There were no procedure-related transient ischemic attacks (TIA), minor/major strokes, or deaths. Angiographic follow-up for a mean of 28.0±21.6 months showed all stents were patent, with average stenosis of 25.2±12.2%. Focal ovalization and kinking of the closed-cell design was noted at the sharpest curve in one patient. Clinical outcome (follow-up of 28.1±21.5 months) demonstrated overall improvement with no clinical worsening, new TIA, or stroke. Tonsillar loop-associated carotid dissections can be successfully and durably recanalized using the low-profile Enterprise stent with an excellent long-term patency rate and low procedural risk. The possibility of stent kinking and low radial force should be considered when planning reconstruction with this device.


Assuntos
Dissecação da Artéria Carótida Interna/cirurgia , Procedimentos Endovasculares/métodos , Stents , Adulto , Angiografia Digital , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA