Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.950
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Circulation ; 149(22): e1223-e1238, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38660790

RESUMO

Tricuspid valve disease is an often underrecognized clinical problem that is associated with significant morbidity and mortality. Unfortunately, patients will often present late in their disease course with severe right-sided heart failure, pulmonary hypertension, and life-limiting symptoms that have few durable treatment options. Traditionally, the only treatment for tricuspid valve disease has been medical therapy or surgery; however, there have been increasing interest and success with the use of transcatheter tricuspid valve therapies over the past several years to treat patients with previously limited therapeutic options. The tricuspid valve is complex anatomically, lying adjacent to important anatomic structures such as the right coronary artery and the atrioventricular node, and is the passageway for permanent pacemaker leads into the right ventricle. In addition, the mechanism of tricuspid pathology varies widely between patients, which can be due to primary, secondary, or a combination of causes, meaning that it is not possible for 1 type of device to be suitable for treatment of all cases of tricuspid valve disease. To best visualize the pathology, several modalities of advanced cardiac imaging are often required, including transthoracic echocardiography, transesophageal echocardiography, cardiac computed tomography, and cardiac magnetic resonance imaging, to best visualize the pathology. This detailed imaging provides important information for choosing the ideal transcatheter treatment options for patients with tricuspid valve disease, taking into account the need for the lifetime management of the patient. This review highlights the important background, anatomic considerations, therapeutic options, and future directions with regard to treatment of tricuspid valve disease.


Assuntos
American Heart Association , Valva Tricúspide , Humanos , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/patologia , Estados Unidos , Doenças das Valvas Cardíacas/terapia , Doenças das Valvas Cardíacas/diagnóstico por imagem , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/terapia , Implante de Prótese de Valva Cardíaca
2.
Annu Rev Med ; 74: 155-170, 2023 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-36400067

RESUMO

This review discusses recent advancements in the field of valvular heart disease. Topics covered include recognition of the impact of atrial fibrillation on development and assessment of valvular disease, strategies for global prevention of rheumatic heart disease, understanding and management of secondary mitral regurgitation, the updated classification of bicuspid aortic valve disease, recognition of heightened cardiovascular risk associated with moderate aortic stenosis, and a growing armamentarium of transcatheter therapies.


Assuntos
Estenose da Valva Aórtica , Fibrilação Atrial , Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Insuficiência da Valva Mitral , Humanos , Doenças das Valvas Cardíacas/terapia , Insuficiência da Valva Mitral/terapia , Estenose da Valva Aórtica/terapia , Doença da Válvula Aórtica Bicúspide/complicações
3.
Eur Heart J ; 45(11): 895-911, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38441886

RESUMO

Atrial secondary tricuspid regurgitation (A-STR) is a distinct phenotype of secondary tricuspid regurgitation with predominant dilation of the right atrium and normal right and left ventricular function. Atrial secondary tricuspid regurgitation occurs most commonly in elderly women with atrial fibrillation and in heart failure with preserved ejection fraction in sinus rhythm. In A-STR, the main mechanism of leaflet malcoaptation is related to the presence of a significant dilation of the tricuspid annulus secondary to right atrial enlargement. In addition, there is an insufficient adaptive growth of tricuspid valve leaflets that become unable to cover the enlarged annular area. As opposed to the ventricular phenotype, in A-STR, the tricuspid valve leaflet tethering is typically trivial. The A-STR phenotype accounts for 10%-15% of clinically relevant tricuspid regurgitation and has better outcomes compared with the more prevalent ventricular phenotype. Recent data suggest that patients with A-STR may benefit from more aggressive rhythm control and timely valve interventions. However, little is mentioned in current guidelines on how to identify, evaluate, and manage these patients due to the lack of consistent evidence and variable definitions of this entity in recent investigations. This interdisciplinary expert opinion document focusing on A-STR is intended to help physicians understand this complex and rapidly evolving topic by reviewing its distinct pathophysiology, diagnosis, and multi-modality imaging characteristics. It first defines A-STR by proposing specific quantitative criteria for defining the atrial phenotype and for discriminating it from the ventricular phenotype, in order to facilitate standardization and consistency in research.


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Feminino , Idoso , Insuficiência da Valva Tricúspide/etiologia , Insuficiência da Valva Tricúspide/complicações , Átrios do Coração/diagnóstico por imagem , Valva Tricúspide/diagnóstico por imagem , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Fibrilação Atrial/terapia
4.
Eur Heart J ; 2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39212387

RESUMO

BACKGROUND AND AIMS: Severe tricuspid regurgitation (TR) is associated with increased mortality rates, but benefit of its correction and ideal timing are not clearly determined. This study aimed to identify patient subsets who might benefit from surgery. METHODS: In TRIGISTRY, an international cohort study of consecutive patients with severe isolated functional TR (33 centers, 10 countries), survival rates up to 10 years were compared between patients who underwent isolated tricuspid valve (TV) surgery (repair or replacement) and those conservatively managed, overall and according to TRI-SCORE category (low: ≤3, intermediate: 4-5, high: ≥6). RESULTS: 1,217 were managed conservatively, and 551 underwent isolated TV surgery (200 repairs, 351 replacements). TRI-SCORE distribution was 33% low, 32% intermediate, and 35% high. At 10 years, survival rates were similar between surgical and conservative management (41% vs. 36%; hazard ratio [HR] 0.97; 95% confidence interval [CI] 0.88-1.08, P=0.57). Surgery improved survival compared to conservative management in the low TRI-SCORE category (72% vs. 44%; HR 0.27; 95% CI 0.20-0.37, P<0.0001), but not in the intermediate (36% vs. 37%, HR 1.17; 95%CI 0.98-1.40, P=0.09) or high categories (20% vs. 24%; HR 1.06; 95% CI 0.91-1.25, P=0.45). Both repair and replacement improved survival in the low TRI-SCORE category (84% and 61% vs. 44%; HR 0.11; 95% CI 0.06-0.19, P<0.0001, and HR 0.65; 95% CI 0.47-0.90, P=0.009). Repair showed benefit in the intermediate category (59% vs. 37%; HR 0.49; 95% CI 0.35-0.68, P<0.0001) while replacement was possibly harmful (25% vs. 37%; HR 1.43; 95% CI 1.18-1.72, P=0.0002). CONCLUSIONS: Higher survival rates were observed with repair than replacement and benefit of intervention declined as TRI-SCORE increased with no benefit of any type of surgery in the high TRI-SCORE category. These results emphasize the importance of timely intervention and patient selection to achieve the best outcomes and the need for randomized controlled trials. TRIAL REGISTRATION: TRIGISTRY: ClinicalTrials.gov, NCT05825898.

5.
Eur Heart J ; 45(8): 586-597, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-37624856

RESUMO

BACKGROUND AND AIMS: Benefit of tricuspid regurgitation (TR) correction and timing of intervention are unclear. This study aimed to compare survival rates after surgical or transcatheter intervention to conservative management according to a TR clinical stage as assessed using the TRI-SCORE. METHODS: A total of 2,413 patients with severe isolated functional TR were enrolled in TRIGISTRY (1217 conservatively managed, 551 isolated tricuspid valve surgery, and 645 transcatheter valve repair). The primary endpoint was survival at 2 years. RESULTS: The TRI-SCORE was low (≤3) in 32%, intermediate (4-5) in 33%, and high (≥6) in 35%. A successful correction was achieved in 97% and 65% of patients in the surgical and transcatheter groups, respectively. Survival rates decreased with the TRI-SCORE in the three treatment groups (all P < .0001). In the low TRI-SCORE category, survival rates were higher in the surgical and transcatheter groups than in the conservative management group (93%, 87%, and 79%, respectively, P = .0002). In the intermediate category, no significant difference between groups was observed overall (80%, 71%, and 71%, respectively, P = .13) but benefit of the intervention became significant when the analysis was restricted to patients with successful correction (80%, 81%, and 71%, respectively, P = .009). In the high TRI-SCORE category, survival was not different to conservative management in the surgical and successful repair group (61% and 68% vs 58%, P = .26 and P = .18 respectively). CONCLUSIONS: Survival progressively decreased with the TRI-SCORE irrespective of treatment modality. Compared to conservative management, an early and successful surgical or transcatheter intervention improved 2-year survival in patients at low and, to a lower extent, intermediate TRI-SCORE, while no benefit was observed in the high TRI-SCORE category.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Resultado do Tratamento , Cateterismo Cardíaco
6.
Eur Heart J ; 45(5): 346-365, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38096587

RESUMO

The role of cardiac implantable electronic device (CIED)-related tricuspid regurgitation (TR) is increasingly recognized as an independent clinical entity. Hence, interventional TR treatment options continuously evolve, surgical risk assessment and peri-operative care improve the management of CIED-related TR, and the role of lead extraction is of high interest. Furthermore, novel surgical and interventional tricuspid valve treatment options are increasingly applied to patients suffering from TR associated with or related to CIEDs. This multidisciplinary review article developed with electrophysiologists, interventional cardiologists, imaging specialists, and cardiac surgeons aims to give an overview of the mechanisms of disease, diagnostics, and proposes treatment algorithms of patients suffering from TR associated with CIED lead(s) or leadless pacemakers.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Cardiopatia Reumática , Insuficiência da Valva Tricúspide , Humanos , Marca-Passo Artificial/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/complicações , Cardiopatia Reumática/complicações , Estudos Retrospectivos
7.
Eur Heart J ; 45(11): 876-894, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38426859

RESUMO

Transcatheter tricuspid valve interventions (TTVI) are emerging as alternatives to surgery in high-risk patients with isolated or concomitant tricuspid regurgitation. The development of new minimally invasive solutions potentially more adapted to this largely undertreated population of patients, has fuelled the interest for the tricuspid valve. Growing evidence and new concepts have contributed to revise obsolete and misleading perceptions around the right side of the heart. New definitions, classifications, and a better understanding of the disease pathophysiology and phenotypes, as well as their associated patient journeys have profoundly and durably changed the landscape of tricuspid disease. A number of registries and a recent randomized controlled pivotal trial provide preliminary guidance for decision-making. TTVI seem to be very safe and effective in selected patients, although clinical benefits beyond improved quality of life remain to be demonstrated. Even if more efforts are needed, increased disease awareness is gaining momentum in the community and supports the establishment of dedicated expert valve centres. This review is summarizing the achievements in the field and provides perspectives for a less invasive management of a no-more-forgotten disease.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Valva Tricúspide/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Qualidade de Vida , Cateterismo Cardíaco/efeitos adversos , Insuficiência da Valva Tricúspide/etiologia , Resultado do Tratamento
8.
Eur Heart J ; 45(31): 2878-2890, 2024 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-38953772

RESUMO

BACKGROUND AND AIMS: Incidence and types of secondary tricuspid regurgitation (TR) are not well defined in atrial fibrillation (AFib) and sinus rhythm (SR). Atrial secondary TR (A-STR) is associated with pre-existing AFib; however, close to 50% of patients with A-STR do not have AFib. The aim of this study was to assess incidence, types, and outcomes of ≥ moderate TR in AFib vs. SR. METHODS: Adults with and without new-onset AFib without structural heart disease or ≥ moderate TR at baseline were followed for the development of ≥ moderate TR. Tricuspid regurgitation types were pacemaker, left-sided valve disease, left ventricular (LV) dysfunction, pulmonary hypertension (PH), isolated ventricular, and A-STR. RESULTS: Among 1359 patients with AFib and 20 438 in SR, 109 and 378 patients developed ≥ moderate TR, respectively. The individual types of TR occurred more frequently in AFib related to the higher pacemaker implantation rates (1.12 vs. 0.19 per 100 person-years, P < .001), larger right atrial size (median 78 vs. 53 mL, P < .001), and higher pulmonary pressures (median 30 vs. 28 mmHg, P < .001). The most common TR types irrespective of rhythm were LV dysfunction-TR and A-STR. Among patients in SR, those with A-STR were older, predominantly women with more diastolic abnormalities and higher pulmonary pressures. All types of secondary TR were associated with all-cause mortality, highest in PH-TR and LV dysfunction-TR. CONCLUSIONS: New-onset AFib vs. SR conferred a higher risk of the individual TR types related to sequelae of AFib and higher pacemaker implantation rates, although the distribution of TR types was similar. Secondary TR was universally associated with increased mortality.


Assuntos
Fibrilação Atrial , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/epidemiologia , Insuficiência da Valva Tricúspide/fisiopatologia , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/complicações , Feminino , Masculino , Idoso , Incidência , Pessoa de Meia-Idade , Marca-Passo Artificial
9.
Eur Heart J ; 45(37): 3804-3814, 2024 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-38747246

RESUMO

BACKGROUND AND AIMS: Transcatheter aortic valve implantation (TAVI) has become the first choice to treat older patients with severe symptomatic aortic stenosis (AS). This study aimed to compare TAVI with surgery in low-risk patients ≤75 years of age, including both tricuspid and bicuspid AS. METHODS: The Nordic Aortic Valve Intervention (NOTION)-2 trial enrolled and 1:1 randomized low-risk patients aged ≤75 years with severe symptomatic AS to TAVI or surgery. The primary endpoint was a composite of all-cause mortality, stroke, or rehospitalization (related to the procedure, valve, or heart failure) at 12 months. RESULTS: A total of 370 patients were enrolled with a mean age of 71.1 years and a median Society of Thoracic Surgeons risk score of 1.1%. A total of 100 patients had bicuspid AS. The 1-year incidence of the primary endpoint was 10.2% in the TAVI group and 7.1% in the surgery group [absolute risk difference 3.1%; 95% confidence interval (CI), -2.7% to 8.8%; hazard ratio (HR) 1.4; 95% CI, 0.7-2.9; P = .3]. Patients with TAVI, when compared to surgery, had lower risk of major bleeding and new-onset atrial fibrillation and higher risk of non-disabling stroke, permanent pacemaker implantation, and moderate or greater paravalvular regurgitation. The risk of the primary composite endpoint was 8.7% and 8.3% in patients with tricuspid AS (HR 1.0; 95% CI, 0.5-2.3) and 14.3% and 3.9% in patients with bicuspid AS (HR 3.8; 95% CI, 0.8-18.5) treated with TAVI or surgery, respectively (P for interaction = .1). CONCLUSIONS: Among low-risk patients aged ≤75 years with severe symptomatic AS, the rate of the composite of death, stroke, or rehospitalization at 1 year was similar between TAVI and surgery. Transcatheter aortic valve implantation outcomes in young bicuspid AS patients warrant caution and should be further investigated. (NOTION-2, ClinicalTrials.gov, NCT02825134). TRIAL REGISTRATION NUMBER: ClinicalTrials.gov NCT02825134.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Masculino , Feminino , Idoso , Doença da Válvula Aórtica Bicúspide/cirurgia , Doença da Válvula Aórtica Bicúspide/complicações , Valva Aórtica/cirurgia , Valva Aórtica/anormalidades , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Doenças das Valvas Cardíacas/cirurgia , Doenças das Valvas Cardíacas/complicações , Resultado do Tratamento , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Readmissão do Paciente/estatística & dados numéricos , Valva Tricúspide/cirurgia
10.
Dev Dyn ; 253(1): 107-118, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37042466

RESUMO

BACKGROUND: Endocardial cushion tissue is primordia of the valves and septa of the adult heart, and its malformation causes various congenital heart diseases (CHDs). Tricuspid atresia (TA) is defined as congenital absence or agenesis of the tricuspid valve caused by endocardial cushion defects. However, little is known about what type of endocardial cushion defect causes TA. RESULTS: Using three-dimensional volume rendering image analysis, we demonstrated morphological changes of endocardial cushion tissue in developing Hey2/Hrt2 KO mouse embryos that showed malformation of the tricuspid valve, which resembled human TA at neonatal period. In control embryos, atrioventricular (AV) endocardial cushion tissues showed rightward shift to form a tricuspid valve. However, the rightward shift of endocardial cushion tissue was disrupted in Hey2/Hrt2 KO embryos, leading to the misalignment of AV cushions. We also found that muscular tissue filled up the space between the right atrium and ventricle, resulting in the absence of the tricuspid valve. Moreover, analysis using tissue-specific conditional KO mice showed that HEY2/HRT2-expressing myocardium may physically regulate the AV shift. CONCLUSION: Disruption of rightward cushion movement is an initial cue of TA phenotype, and myocardial HEY2/HRT2 is necessary for the regulation of proper alignment of AV endocardial cushion tissue.


Assuntos
Comunicação Atrioventricular , Atresia Tricúspide , Animais , Camundongos , Humanos , Coração , Miocárdio , Fatores de Transcrição , Fatores de Transcrição Hélice-Alça-Hélice Básicos/genética , Proteínas Repressoras
11.
Magn Reson Med ; 92(5): 1838-1850, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38817154

RESUMO

PURPOSE: Tricuspid valve flow velocities are challenging to measure with cardiovascular MR, as the rapidly moving valvular plane prohibits direct flow evaluation, but they are vitally important to diastolic function evaluation. We developed an automated valve-tracking 2D method for measuring flow through the dynamic tricuspid valve. METHODS: Nine healthy subjects and 2 patients were imaged. The approach uses a previously trained deep learning network, TVnet, to automatically track the tricuspid valve plane from long-axis cine images. Subsequently, the tracking information is used to acquire 2D phase contrast (PC) with a dynamic (moving) acquisition plane that tracks the valve. Direct diastolic net flows evaluated from the dynamic PC sequence were compared with flows from 2D-PC scans acquired in a static slice localized at the end-systolic valve position, and also ventricular stroke volumes (SVs) using both planimetry and 2D PC of the great vessels. RESULTS: The mean tricuspid valve systolic excursion was 17.8 ± 2.5 mm. The 2D valve-tracking PC net diastolic flow showed excellent correlation with SV by right-ventricle planimetry (bias ± 1.96 SD = -0.2 ± 10.4 mL, intraclass correlation coefficient [ICC] = 0.92) and aortic PC (-1.0 ± 13.8 mL, ICC = 0.87). In comparison, static tricuspid valve 2D PC also showed a strong correlation but had greater bias (p = 0.01) versus the right-ventricle SV (10.6 ± 16.1 mL, ICC = 0.61). In most (8 of 9) healthy subjects, trace regurgitation was measured at begin-systole. In one patient, valve-tracking PC displayed a high-velocity jet (380 cm/s) with maximal velocity agreeing with echocardiography. CONCLUSION: Automated valve-tracking 2D PC is a feasible route toward evaluation of tricuspid regurgitant velocities, potentially solving a major clinical challenge.


Assuntos
Aprendizado Profundo , Imagem Cinética por Ressonância Magnética , Valva Tricúspide , Humanos , Valva Tricúspide/diagnóstico por imagem , Masculino , Feminino , Adulto , Imagem Cinética por Ressonância Magnética/métodos , Velocidade do Fluxo Sanguíneo , Pessoa de Meia-Idade , Diástole , Processamento de Imagem Assistida por Computador/métodos , Volume Sistólico/fisiologia , Interpretação de Imagem Assistida por Computador/métodos , Algoritmos , Reprodutibilidade dos Testes , Sístole/fisiologia
12.
J Cardiovasc Electrophysiol ; 35(5): 929-938, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38450808

RESUMO

INTRODUCTION: Transvenous leads have been implicated in tricuspid valve (TV) dysfunction, but limited data are available regarding the effect of extracting leads across the TV on valve regurgitation. The aim of this study is to quantify tricuspid regurgitation (TR) before and after lead extraction and identify predictors of worsening TR. METHODS: We studied 321 patients who had echocardiographic data before and after lead extraction. TR was graded on a scale (0 = none/trivial, 1 = mild, 2 = moderate, 3 = severe). A change of >1 grade following extraction was considered significant. RESULTS: A total of 321 patients underwent extraction of a total of 338 leads across the TV (1.05 ± 0.31 leads across the TV per patient). There was no significant difference on average TR grade pre- and postextraction (1.18 ± 0.91 vs. 1.15 ± 0.87; p = 0.79). TR severity increased after extraction in 84 patients, but was classified as significantly worse (i.e., >1 grade change in severity) in only 8 patients (2.5%). Use of laser lead extraction was associated with a higher rate of worsening TR postextraction (44.0% vs. 31.6%, p = 0.04). CONCLUSION: In our single-center analysis, extraction of leads across the TV did not significantly affect the extent of TR in most patients. Laser lead extraction was associated with a higher rate of worsening TR after extraction.


Assuntos
Remoção de Dispositivo , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/etiologia , Insuficiência da Valva Tricúspide/diagnóstico , Masculino , Feminino , Remoção de Dispositivo/efeitos adversos , Idoso , Resultado do Tratamento , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Valva Tricúspide/fisiopatologia , Valva Tricúspide/cirurgia , Valva Tricúspide/diagnóstico por imagem , Desfibriladores Implantáveis , Fatores de Tempo , Marca-Passo Artificial , Idoso de 80 Anos ou mais , Dispositivos de Terapia de Ressincronização Cardíaca
13.
J Cardiovasc Electrophysiol ; 35(5): 1017-1025, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38501386

RESUMO

Tricuspid regurgitation (TR) secondary to cardiac implantable electronic devices (CIEDs) has been well documented and is associated with worse cardiovascular outcomes. A variety of mechanisms have been proposed including lead-induced mechanical disruption of the tricuspid valvular or subvalvular apparatus and pacing-induced electrical dyssynchrony. Patient characteristics such as age, sex, baseline atrial fibrillation, and pre-existing TR have not been consistent predictors of CIED-induced TR. While two-dimensional echocardiography is helpful in assessing the severity of TR, three-dimensional echocardiography has significantly improved accuracy in identifying the etiology of TR and whether lead position contributes to TR. Three-dimensional echocardiography may therefore play a future role in optimizing lead positioning during implant to reduce the risk of CIED-induced TR. Optimal lead management strategies in addition to percutaneous interventions and surgery in alleviating TR are very important.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/etiologia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/cirurgia , Desfibriladores Implantáveis/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Valva Tricúspide/fisiopatologia , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Fatores de Risco , Resultado do Tratamento , Ecocardiografia Tridimensional
14.
J Cardiovasc Electrophysiol ; 35(10): 2056-2057, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39080873

RESUMO

BACKGROUND: Implantable cardioverter-defibrillators are used globally and are reliable, but complications related to transvenous leads remain a concern. Evidence related to the incidence and costs of those complications is heterogeneous with respect to scope and healthcare system. This analysis aims to create estimates of the incidence and costs of tricuspid valve (TV) complications, lead failures, and lead extractions from a single large real-world data set. METHODS AND RESULTS: This retrospective longitudinal cohort study used the deidentified Medicare Fee for Service administrative claims database. A total of 116 036 patients with de novo transvenous ICD implant were analyzed. Mean hospital costs were $26 903 for tricuspid valve complications, $20 851 for lead failures, and $22 278 for lead extractions. CONCLUSIONS: Transvenous ICD lead complications incur significant costs to patients, hospitals, and payers when they occur. Advancements in lead technology that reduce these complications could bring significant clinical and economic value.


Assuntos
Bases de Dados Factuais , Desfibriladores Implantáveis , Remoção de Dispositivo , Custos Hospitalares , Medicare , Valva Tricúspide , Humanos , Desfibriladores Implantáveis/economia , Desfibriladores Implantáveis/efeitos adversos , Estudos Retrospectivos , Feminino , Masculino , Incidência , Estados Unidos/epidemiologia , Idoso , Valva Tricúspide/fisiopatologia , Valva Tricúspide/cirurgia , Estudos Longitudinais , Medicare/economia , Remoção de Dispositivo/economia , Remoção de Dispositivo/efeitos adversos , Idoso de 80 Anos ou mais , Resultado do Tratamento , Cardioversão Elétrica/economia , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/efeitos adversos , Demandas Administrativas em Assistência à Saúde , Fatores de Tempo , Fatores de Risco
15.
J Cardiovasc Electrophysiol ; 35(5): 1050-1054, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38501328

RESUMO

INTRODUCTION: Tricuspid regurgitation is associated with significant morbidity and mortality, and occurs at a higher rate in patients with cardiovascular implantable electronic devices. Percutaneous strategies for managing tricuspid regurgitation are evolving, including the development of bicaval valve implantation which has been successfully used in patients with pacing leads. METHODS AND RESULTS: We present the first documented case of lead failure following TricValve® implantation, a dedicated self-expanding system for bicaval valve implantation, and the first successful lead revision procedure in this setting. CONCLUSION: The case illustrates important considerations in undertaking percutaneous intervention in patients with cardiovascular implantable electronic devices, and their ongoing management.


Assuntos
Desfibriladores Implantáveis , Falha de Equipamento , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Masculino , Idoso , Resultado do Tratamento , Reoperação , Desenho de Prótese , Remoção de Dispositivo , Feminino , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/efeitos adversos
16.
Artigo em Inglês | MEDLINE | ID: mdl-39327904

RESUMO

Tricuspid regurgitation (TR) is a known complication of cardiac implantable electrical devices (CIEDs), with prevalences ranging from 10% to as high as 30%. Despite left bundle branch area pacing (LBBAP) has emerged as an alternative to the limits of His-bundle pacing (HBP), the long-term safety of this procedure, notably the worsening of TR after implantation, has yet to be thoroughly investigated. This meta-analysis sought to determine the frequency of post-LBBAP TR deterioration and identify the predictors, particularly the distance between lead-implanted site and the tricuspid valve annulus (lead-TA-distance). A systematic literature search was conducted using PubMed, Europe PMC, and ScienceDirect for studies that reported the incidence of deterioration and measurement of TR grade at baseline and follow-up following LBBAP, in addition to the differences in exposure between short and long lead-TA-distances. A total of three studies involving 480 participants were included in this meta-analysis. The incidence of TR deterioration was 22%. Patients with TR deterioration also demonstrated a significantly shorter lead-TA-distance in comparison to the opposing group (MD: -5.74 mm (-0.70, -10.78); p < .001; I2 = 92.6%). The pooled results of three comparative studies suggest that participants in the longer lead-TA-distance group had a significant decrement in the likelihood of TR worsening (adjusted OR = 0.59 (0.36-0.96); p = .034; I2 = 79%). Multivariate analysis conducted in each of the included investigations supported the independence of the connection between lead-TA-distance and TR deterioration. A shorter lead-TA-distance was an independent risk factor for TR deterioration in individuals with post-LBBAP implantation.

17.
J Cardiovasc Electrophysiol ; 35(8): 1601-1613, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38887842

RESUMO

INTRODUCTION: Four-dimensional (4D) intracardiac echocardiography (ICE) is a novel cardiac imaging modality that has been applied to various workflows, including catheter ablation, tricuspid valve repair, and left atrial appendage occlusion (LAAO). The use of this type of advanced ICE imaging may ultimately allow for the replacement of transesophageal echocardiography (TEE) for LAAO, providing comparable imaging quality while eliminating the need for general anesthesia. METHODS: Based on our initial clinical experience with 4D ICE in LAAO, we have developed an optimized workflow for the use of the NUVISION™ 4D ICE Catheter in conjunction with the GE E95 and S70N Ultrasound Systems in LAAO. In this manuscript, we provide a step-by-step guide to using 4D ICE in conjunction with compatible imaging consoles. We have also evaluated the performance of 4D ICE with the NUVISION Ultrasound Catheter versus TEE in one LAAO case and present those results here. RESULTS: In our comparison of 4D ICE using our optimized workflow with TEE in an LAAO case, ICE LAA measurements were similar to those from TEE. The best image resolution was seen via ICE in 2-dimensional and multislice modes (triplane and biplane). The FlexiSlice multiplanar reconstruction tool, which creates an en-face image derived from a 4D volume set, also provided valuable information but yielded slightly lower image quality, as expected for these volume-derived images. For this case, comparable images were obtained with TEE and ICE but with less need to reposition the ICE catheter. CONCLUSION: The use of optimized 4D ICE catheter workflow recommendations allows for efficient LAAO procedures, with higher resolution imaging, comparable to TEE.


Assuntos
Apêndice Atrial , Ecocardiografia Quadridimensional , Ecocardiografia Transesofagiana , Fluxo de Trabalho , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Valor Preditivo dos Testes , Cateterismo Cardíaco/instrumentação , Ultrassonografia de Intervenção , Masculino
18.
Artigo em Inglês | MEDLINE | ID: mdl-39238168

RESUMO

BACKGROUND: Complications associated with cardiovascular implantable electronic devices may necessitate device and lead removal. An open approach to removal may be electively chosen in cases with high risk of complications or those requiring additional concomitant cardiac surgery. This study aimed to investigate outcomes of patients who underwent elective open lead extractions (OLE) at two large tertiary care centers. METHODS: The records of 29 patients undergoing elective OLE were analyzed through retrospective chart review. RESULTS: 69 total leads were extracted from 29 patients (77% completely, 23% partially). The average age of the oldest leads was 13.3 ± 11.3 years. Infective endocarditis with severe valvular insufficiency requiring valvular intervention (41%)-an infectious etiology, and tricuspid valve intervention to correct RV lead-related severe TR (38%)-a noninfectious etiology, were the most common reasons for OLE. 38% of the patients had additional co-primary or secondary indications for open extraction, such as CABG and pericardiectomies. The rate of major complications and procedural failure was 3% each (1/29). 30-day survival was 100%, and 1-year survival was 92%. The average length of hospital stay was 15 days and higher among those undergoing OLE for infectious indications. CONCLUSION: Open lead extractions offered a similar clinical success rate (97%) to transvenous extractions in this cohort and may be a viable alternative for those necessitating valvular intervention or when the risk of complications from TLE is considered very high.

19.
Artigo em Inglês | MEDLINE | ID: mdl-39256904

RESUMO

INTRODUCTION: This case report highlights the novel role of His-bundle pacing (HBP) from right atrium, not just for preserving cardiac function, but also for avoiding interference with TriClip devices. METHODS AND RESULTS: A 78-year-old female with severe tricuspid regurgitation received two TriClip devices. Postprocedure, frequent significant sinus pauses required a pacemaker. HBP was chosen to avoid lead complications. Under local anesthesia, a His pacing lead was inserted via the axillary vein using specialized catheter. Follow-ups over 2.5 years showed stable parameters with no complications. CONCLUSION: HBP is effective for patients with TriClip devices, ensuring optimal cardiac function and lead stability.

20.
J Card Fail ; 30(10): 1265-1272, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39389736

RESUMO

Novel transcatheter therapies for tricuspid regurgitation (TR) appear promising, yet their applicability to an all-comer TR population remains unclear. We aimed to assess the feasibility of emerging transcatheter tricuspid therapies in a real-world population with greater than or equal to moderate symptomatic TR. A total of 178 patients were referred to our center between January 2019 and December 2021 for greater than or equal to moderate symptomatic TR and were classified into 4 groups: Investigative (patients eligible for enrollment in the Triluminate, Clasp TR, and TRISCEND trials), off-label clipping, surgery, and medical treatment. A total of 10.7% of the population were deemed eligible for investigative therapies, 20.2% and 19.7% of patients were offered off-label clipping and surgery, respectively, and 49.4% received medical treatment. Common reasons for investigative therapy-related ineligibility were unsuitable anatomy (large tricuspid annulus or wide leaflet coaptation gap) and the presence of significant comorbidities. Compared with the other groups, the investigative group was less likely to harbor concomitant ≥moderate mitral regurgitation, greater than or equal to moderate right ventricular dysfunction or severe pulmonary hypertension (P < .05). At 1 year, there remained a significant reduction in TR severity in the investigative group (P < .001) in comparison with the medical treatment group. However, the results were comparable to off-label clipping (P = .60) and inferior to surgery (P =.04). Exploratory analyses failed to show evidence of differences in the rates of all-cause mortality (P =.40) and heart failure hospitalizations (P = .94) between all groups. Current real-world eligibility of TR patients for emerging transcatheter therapies remains limited, underscoring the need for continued innovative efforts to offer device therapies to a broader TR cohort.


Assuntos
Cateterismo Cardíaco , Estudos de Viabilidade , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/cirurgia , Feminino , Masculino , Cateterismo Cardíaco/métodos , Idoso , Implante de Prótese de Valva Cardíaca/métodos , Estudos Retrospectivos , Definição da Elegibilidade/métodos , Seleção de Pacientes , Idoso de 80 Anos ou mais , Resultado do Tratamento , Valva Tricúspide/cirurgia , Valva Tricúspide/diagnóstico por imagem , Pessoa de Meia-Idade , Seguimentos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA