Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 455
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
J Card Fail ; 30(4): 552-561, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37898382

RESUMO

BACKGROUND: Left ventricular assist devices (LVADs) have been implanted as bridge to transplantation (BTT), bridge to candidacy (BTC) or destination therapy (DT) on the basis of relative and absolute contraindications to transplantation. Multiple factors may lead to changes in the strategy of support after LVAD implantation. METHODS: Based on INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support) 2012-2020 data, 11,262 patients survived to 3 months on continuous-flow LVADs with intent of BTT or DT. Preimplant characteristics and early events post-LVAD were analyzed in relation to changes in BTT or DT strategy during the next 12 months. RESULTS: Among 3216 BTT patients at 3 months, later transplant delisting or death without transplant occurred in 536 (16.7%) and was more common with age, profiles 1-2, renal dysfunction, and independently for prior cardiac surgery (HR 1.25, 95% CI 1.04-1.51; P = 0.02). Post-LVAD events of infections, gastrointestinal bleeding, stroke, and right heart failure as defined by inotropic therapy, predicted delisting and death, as did in-hospital location at 3 months (HR 1.67, 95% CI 1.20-2.33; P = 0.0024). Of 8046 patients surviving to 3 months with the intent of destination therapy, 750 (9.3%) subsequently underwent listing or transplantation, often with initial histories of acute HF (HR 1.70, 95% CI 1.27-2.27; P = 0.0012) or malnutrition-cachexia (1.73, 95% CI 1.14-2.63; P = 0.0099). Multiple gastrointestinal bleeding events (≥ 4) with LVAD increased transition from BTT to DT (HR 4.22, 95% CI 1.46-12.275; P = 0.0078) but also from DT to BTT (HR 5.17, 95% CI 1.92-13.9; P = 0.0011). CONCLUSIONS: Implant strategies change over time in relation to preimplant characteristics and adverse events post implant. Preimplant recognition of factors predicting later change in implant strategy will refine initial triage, whereas further reduction of post-LVAD complications will expand options, including eventual consideration of heart transplantation.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Humanos , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/cirurgia , Transplante de Coração/efeitos adversos , Coração Auxiliar/efeitos adversos , Hemorragia Gastrointestinal/etiologia , Fatores de Tempo , Resultado do Tratamento , Estudos Retrospectivos
2.
J Card Fail ; 2024 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-39154903

RESUMO

Long-term outcomes of patients with advanced heart failure treated with durable left ventricular assist devices (LVADs) have been augmented due to improved durability and hemocompatibility on the backbone of pump engineering enhancements. The incidence of hemocompatibility-related adverse events (pump thrombosis, stroke and nonsurgical bleeding events) are device specific and vary by type of engineered pump. A fully magnetically levitated rotor containing LVAD in concert with use of antithrombotic therapy has successfully overcome an increased risk of pump thrombosis and stroke-risk, albeit with only modest reduction in bleeding events. Modifications to antithrombotic strategies have focused on reduced-dose vitamin K antagonist use or use of direct oral anticoagulants with demonstration of safety and progress in reduction of mucosal bleeding episodes with elimination of antiplatelet agents. This review outlines the current landscape of advances in anticoagulation management in LVAD patients, highlighting the need for ongoing research and cautious application of emerging therapies and technologies.

3.
Rev Cardiovasc Med ; 25(5): 176, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-39076481

RESUMO

Heart failure (HF) is a common disease associated with high morbidity and mortality rates despite advanced pharmacological therapies. Heart transplantation remains the gold standard therapy for end-stage heart failure; however, its application is curtailed by the persistent shortage of donor organs. Over the past two decades, mechanical circulatory support, notably Left Ventricular Assist Devices (LVADs), have been established as an option for patients waiting for a donor organ. This comprehensive review focuses on elucidating the benefits and barriers associated with this application. We provide an overview of landmark clinical trials that have evaluated the use of LVADs as a bridge to transplantation therapy, with a particular focus on post-transplant outcomes. We discuss the benefits of stabilizing patients with these systems, weighing associated complications and limitations. Further technical advancements and research on optimal implantation timing are critical to ultimately improve outcomes and securing quality of life. In a world where the availability of donor organs remains constrained, LVADs are an increasingly important piece of patient care, bridging the critical gap to transplantation in advanced heart failure management.

4.
Clin Transplant ; 38(6): e15334, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38864350

RESUMO

INTRODUCTION: The use of veno-arterial extracorporeal membrane oxygenation (VA-ECMO) as a direct bridge to heart transplantation (BTT) is not common in adults worldwide. BTT with ECMO is associated with increased early/mid-term mortality compared with other interventions. In low- and middle-income countries (LMIC), where no other type of short-term mechanical circulatory support is available, its use is widespread and increasingly used as rescue therapy in patients with cardiogenic shock (CS) as a direct bridge to heart transplantation (HT). OBJECTIVE: To assess the outcomes of adult patients using VA-ECMO as a direct BTT in an LMIC and compare them with international registries. METHODS: We conducted a single-center study analyzing consecutive adult patients requiring VA-ECMO as BTT due to refractory CS or cardiac arrest (CA) in a cardiovascular center in Argentina between January 2014 and December 2022. Survival and adverse clinical events after VA-ECMO implantation were evaluated. RESULTS: Of 86 VA-ECMO, 22 (25.5%) were implanted as initial BTT strategy, and 52.1% of them underwent HT. Mean age was 46 years (SD 12); 59% were male. ECMO was indicated in 81% for CS, and the most common underlying condition was coronary artery disease (31.8%). Overall, in-hospital mortality for VA-ECMO as BTT was 50%. Survival to discharge was 83% in those who underwent HT and 10% in those who did not, p < .001. In those who did not undergo HT, the main cause of death was hemorrhagic complications (44%), followed by thrombotic complications (33%). The median duration of VA-ECMO was 6 days (IQR 3-16). There were no differences in the number of days on ECMO between those who received a transplant and those who did not. In the Spanish registry, in-hospital survival after HT was 66.7%; the United Network of Organ Sharing registry estimated post-transplant survival at 73.1% ± 4.4%, and in the French national registry 1-year posttransplant survival was 70% in the VA-ECMO group. CONCLUSIONS: In adult patients with cardiogenic shock, VA-ECMO as a direct BTT allowed successful HT in half of the patients. HT provided a survival benefit in listed patients on VA-ECMO. We present a single center experience with results comparable to those of international registries.


Assuntos
Oxigenação por Membrana Extracorpórea , Transplante de Coração , Choque Cardiogênico , Humanos , Masculino , Feminino , Transplante de Coração/mortalidade , Pessoa de Meia-Idade , Choque Cardiogênico/terapia , Choque Cardiogênico/etiologia , Choque Cardiogênico/mortalidade , Taxa de Sobrevida , Seguimentos , Prognóstico , Estudos Retrospectivos , Adulto , Países em Desenvolvimento , Coração Auxiliar/estatística & dados numéricos , Mortalidade Hospitalar
5.
Artif Organs ; 48(4): 375-385, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37962282

RESUMO

BACKGROUND: Hemocompatibility-related adverse events (HRAE) occur commonly in patients with left ventricular assist devices (LVADs) and add to morbidity and mortality. It is unclear whether the outflow graft orientation can impact flow conditions leading to HRAE. This study presents a simulation-based approach using exact patient anatomy from medical images to investigate the influence of outflow cannula orientation in modulating flow conditions leading to HRAEs. METHODS: A 3D model of a proximal aorta and outflow graft was reconstructed from a computed tomography (CT) scan of an LVAD patient and virtually modified to model multiple cannula orientations (n = 10) by varying polar (cranio-caudal) (n = 5) and off-set (anterior-posterior) (n = 2) angles. Time-dependent computational flow simulations were then performed for each anatomical orientation. Qualitative and quantitative hemodynamics metrics of thrombogenicity including time-averaged wall shear stress (TAWSS), oscillatory shear index (OSI), endothelial cell platelet activation potential (ECAP), particle residence time (PRT), and platelet activation potential (PLAP) were analyzed. RESULTS: Within the simulations performed, endothelial cell activation potential (ECAP) and particle residence time (PRT) were found to be lowest with a polar angle of 85°, regardless of offset angle. However, polar angles that produced parameters at levels least associated with thrombosis varied when the offset angle was changed from 0° to 12°. For offset angles of 0° and 12° respectively, flow shear was lowest at 65° and 75°, time averaged wall shear stress (TAWSS) was highest at 85° and 35°, and platelet activation potential (PLAP) was lowest at 65° and 45°. CONCLUSION: This study suggests that computational fluid dynamic modeling based on patient-specific anatomy can be a powerful analytical tool when identifying optimal positioning of an LVAD. Contrary to previous work, our findings suggest that there may be an "ideal" outflow cannula for each individual patient based on a CFD-based hemocompatibility profile.


Assuntos
Coração Auxiliar , Trombose , Humanos , Coração Auxiliar/efeitos adversos , Modelos Cardiovasculares , Hidrodinâmica , Aorta/fisiologia , Trombose/etiologia , Hemodinâmica/fisiologia
6.
Artif Organs ; 48(2): 141-149, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38018258

RESUMO

BACKGROUND: The reactivity of blood with non-endothelial surface is a challenge for long-term Ventricular Assist Devices development, usually made with pure titanium, which despite of being inert, low density and high mechanical resistance it does not avoid the thrombogenic responses. Here we tested a modification on the titanium surface with Laser Induced Periodic Surface Structures followed by Diamond Like Carbon (DLC) coating in different thicknesses to customize the wettability profile by changing the surface energy of the titanium. METHODS: Four different surfaces were proposed: (1) Pure Titanium as Reference Material (RM), (2) Textured as Test Sample (TS), (3) Textured with DLC 0.3µm as (TSA) and (4) Textured with 2.4µm DLC as (TSB). A single implant was positioned in the abdominal aorta of Wistar rats and the effects of hemodynamic interaction were evaluated without anticoagulant drugs. RESULTS: After twelve weeks, the implants were extracted and subjected to qualitative analysis by Scanning Electron Microscopy under low vacuum and X-ray Energy Dispersion. The regions that remained in contact with the wall of the aorta showed encapsulation of the endothelial tissue. TSB implants, although superhydrophilic, have proven that the DLC coating inhibits the adhesion of biological material, prevents abrasive wear and delamination, as observed in the TS and TSA implants. Pseudo- neointimal layers were heterogeneously identified in higher concentration on Test Surfaces.


Assuntos
Carbono , Titânio , Ratos , Animais , Propriedades de Superfície , Titânio/química , Ratos Wistar , Teste de Materiais , Carbono/química , Aorta , Materiais Revestidos Biocompatíveis/química
7.
Artif Organs ; 48(2): 166-174, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37921338

RESUMO

BACKGROUND: Left ventricular assist device (LVAD) implantation is among the most effective treatment options for patients with severe heart failure. Although previous studies have examined the factors related to peak oxygen uptake (peak VO2 ), they were limited by the few patients involved and their focus on medical and physical functions. Therefore, this study comprehensively examined the factors associated with peak VO2 , which is an important prognostic factor in patients with implantable LVADs. METHODS: Eighty-nine patients who underwent initial LVAD implantation and were eligible for cardiopulmonary exercise testing (CPX) between May 2014 and September 2021 were included. The patients' mean age was 48 ± 12 years, and 70% were males. Based on previous studies, the cut-off was set at 12 and 14 mL/kg/min for patients taking ß-blocker and those not taking ß-blockers, respectively. Furthermore, factors associated with peak VO2 were examined using multivariate logistic regression analysis. RESULTS: The mean time from surgery to CPX administration was 73 ± 40 days. The high group had a higher cardiac index, right ventricular stroke work index (RVSWI), and isometric knee extensor muscular strength and lower Patient Health Questionnaire-9 (PHQ-9) and B-type natriuretic peptide values than the low group. Multivariate logistic regression analysis showed that RVSWI and KEMS were positively correlated, whereas PHQ-9 was negatively associated with peak VO2 . CONCLUSION: Right ventricular function, depressive symptoms, and lower limb muscular strength were associated with exercise capacity in patients with implantable LVADs.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Feminino , Insuficiência Cardíaca/cirurgia , Função Ventricular Direita , Depressão , Teste de Esforço , Oxigênio , Consumo de Oxigênio , Função Ventricular Esquerda
8.
BMC Palliat Care ; 23(1): 128, 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38778297

RESUMO

BACKGROUND: Values are broadly understood to have implications for how individuals make decisions and cope with serious illness stressors, yet it remains uncertain how patients and their family and friend caregivers discuss, reflect upon, and act on their values in the post-left ventricular assist device (LVAD) implantation context. This study aimed to explore the values elicitation experiences of patients with an LVAD in the post-implantation period. METHODS: Qualitative descriptive study of LVAD recipients. Socio-demographics and patient resource use were analyzed using descriptive statistics and semi-structured interview data using thematic analysis. Adult (> 18 years) patients with an LVAD receiving care at an outpatient clinic in the Southeastern United States. RESULTS: Interviewed patients (n = 27) were 30-76 years, 59% male, 67% non-Hispanic Black, 70% married/living with a partner, and 70% urban-dwelling. Three broad themes of patient values elicitation experiences emerged: 1) LVAD implantation prompts deep reflection about life and what is important, 2) patient values are communicated in various circumstances to convey personal goals and priorities to caregivers and clinicians, and 3) patients leverage their values for strength and guidance in navigating life post-LVAD implantation. LVAD implantation was an impactful experience often leading to reevaluation of patients' values; these values became instrumental to making health decisions and coping with stressors during the post-LVAD implantation period. Patient values arose within broad, informal exchanges and focused, decision-making conversations with their caregiver and the healthcare team. CONCLUSIONS: Clinicians should consider assessing the values of patients post-implantation to facilitate shared understanding of their goals/priorities and identify potential changes in their coping.


Assuntos
Coração Auxiliar , Pesquisa Qualitativa , Humanos , Coração Auxiliar/psicologia , Masculino , Pessoa de Meia-Idade , Feminino , Adulto , Idoso , Adaptação Psicológica
9.
J Extra Corpor Technol ; 56(1): 10-15, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38488713

RESUMO

BACKGROUND: Left ventricular assist device (LVAD) candidates are at increased risk of immune dysregulation and infectious complications. To attenuate the elevated proinflammatory cytokine levels and associated adverse clinical outcomes, it has been postulated that extracorporeal blood purification could improve the overall survival rate and morbidity of patients undergoing LVAD implantation. METHODS: We retrospectively reviewed prospectively collected data of 15 patients who underwent LVAD implantation at our center between January 2021 and March 2022. Of these, 15 (100%) who received HeartMate 3™ (St. Jude Medical, Abbott, MN, USA) device were eligible. Intraoperatively, patients were single randomized 1:1:1 to three groups: group 1, patients who received Cytosorb therapy (n = 5; installed in the CPB circuit); group 2, patients who received Jafron HA330 (n = 5; installed in the CPB circuit); and control group 3, patients who did not receive filter (n = 5; usual care, neither Cytosorb nor Jafron during CPB). Baseline patient characteristics and intraoperative data were compared between the groups. Blood sample analyses were performed to assess the levels of inflammatory markers (IL-1, 6, 8; CRP, Leukocyte, Lactate, PCT, NT-proBNP, TNF-α) in both preoperative and postoperative data. RESULTS: Baseline patient characteristics were similar in all three groups. We found that IL1α; IL 6; IL8; Lactatedehydrogenase, PCT, pro-BNP, CRP; Leukocyte, and TNFα levels significantly increased with LVAD implantation and that neither Cytosorb nor Jafron influenced this response. In-hospital mortality and overall survival during follow-up were similar among the groups. CONCLUSION: Our preliminary results showed that hemoadsorption therapy using Cytosorb or Jafron hemoadsorption (HA) 330 may not be clinically beneficial for patients with advanced heart failure undergoing LVAD implantation. Large prospective studies are needed to evaluate the potential role of HA therapy in improving outcomes in patients undergoing LVAD implantation.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Estudos Retrospectivos , Coração Auxiliar/efeitos adversos , Estudos Prospectivos , Resultado do Tratamento
10.
Am J Transplant ; 23(6): 805-814, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36931436

RESUMO

Advanced heart failure (AHF) therapy allocation is vulnerable to bias related to subjective assessments and poor group dynamics. Our objective was to determine whether an implementation strategy for AHF team members could feasibly contribute to organizational and culture change supporting equity in AHF allocation. Using a pretest-posttest design, the strategy included an 8-week multicomponent training on bias reduction, standardized numerical social assessments, and enhanced group dynamics at an AHF center. Evaluations of organizational and cultural changes included pretest-posttest AHF team member surveys, transcripts of AHF meetings to assess group dynamics using a standardized scoring system, and posttest interviews guided by a framework for implementing a complex strategy. Results were analyzed with qualitative descriptive methods and Brunner-Munzel tests for relative effect (RE, RE >0.5 signals posttest improvement). The majority of survey metrics revealed potential benefit with RE >0.5. REs were >0.5 for 5 of 6 group dynamics metrics. Themes for implementation included (1) promoting equitable distribution of scarce resources, (2) requiring a change in team members' time investment to correct bias and change the meeting structure, (3) slowing and then accelerating the allocation process, and (4) adaptable beyond AHF and reinforceable with semi-annual trainings. An implementation strategy for AHF equity demonstrated the feasibility for organizational and culture changes.


Assuntos
Insuficiência Cardíaca , Humanos , Insuficiência Cardíaca/terapia , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA