Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 91
Filtrar
1.
Neurosurg Rev ; 47(1): 374, 2024 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-39083214

RESUMO

The Woven EndoBridge (WEB) device is primarily used for treating wide-neck intracranial bifurcation aneurysms under 10 mm. Limited data exists on its efficacy for large aneurysms. We aim to assess angiographic and clinical outcomes of the WEB device in treating large versus small aneurysms. We conducted a retrospective review of the WorldWide WEB Consortium database, from 2011 to 2022, across 30 academic institutions globally. Propensity score matching (PSM) was employed to compare small and large aneurysms on baseline characteristics. A total of 898 patients were included. There was no significant difference observed in clinical presentations, smoking status, pretreatment mRS, presence of multiple aneurysms, bifurcation location, or prior treatment between the two groups. After PSM, 302 matched pairs showed significantly lower last follow-up adequate occlusion rates (81% vs 90%, p = 0.006) and higher retreatment rates (12% vs 3.6%, p < 0.001) in the large aneurysm group. These findings may inform treatment decisions and patient counseling. Future studies are needed to further explore this area.


Assuntos
Procedimentos Endovasculares , Aneurisma Intracraniano , Pontuação de Propensão , Humanos , Aneurisma Intracraniano/terapia , Aneurisma Intracraniano/cirurgia , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Idoso , Procedimentos Endovasculares/métodos , Resultado do Tratamento , Adulto , Embolização Terapêutica/métodos
2.
Neurosurg Rev ; 47(1): 116, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38483647

RESUMO

BACKGROUND: The Woven EndoBridge (WEB) devices have been used for treating wide neck bifurcation aneurysms (WNBAs) with several generational enhancements to improve clinical outcomes. The original device dual-layer (WEB DL) was replaced by a single-layer (WEB SL) device in 2013. This study aimed to compare the effectiveness and safety of these devices in managing intracranial aneurysms. METHODS: A multicenter cohort study was conducted, and data from 1,289 patients with intracranial aneurysms treated with either the WEB SL or WEB DL devices were retrospectively analyzed. Propensity score matching was utilized to balance the baseline characteristics between the two groups. Outcomes assessed included immediate occlusion rate, complete occlusion at last follow-up, retreatment rate, device compaction, and aneurysmal rupture. RESULTS: Before propensity score matching, patients treated with the WEB SL had a significantly higher rate of complete occlusion at the last follow-up and a lower rate of retreatment. After matching, there was no significant difference in immediate occlusion rate, retreatment rate, or device compaction between the WEB SL and DL groups. However, the SL group maintained a higher rate of complete occlusion at the final follow-up. Regression analysis showed that SL was associated with higher rates of complete occlusion (OR: 0.19; CI: 0.04 to 0.8, p = 0.029) and lower rates of retreatment (OR: 0.12; CI: 0 to 4.12, p = 0.23). CONCLUSION: The WEB SL and DL devices demonstrated similar performances in immediate occlusion rates and retreatment requirements for intracranial aneurysms. The SL device showed a higher rate of complete occlusion at the final follow-up.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Resultado do Tratamento , Aneurisma Intracraniano/cirurgia , Aneurisma Intracraniano/etiologia , Embolização Terapêutica/efeitos adversos , Pontuação de Propensão , Estudos Retrospectivos , Estudos de Coortes , Procedimentos Endovasculares/efeitos adversos
3.
J Stroke Cerebrovasc Dis ; 33(11): 107897, 2024 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-39069148

RESUMO

INTRODUCTION: The Woven EndoBridge (WEB) device is emerging as a novel therapy for intracranial aneurysms, but its use for off-label indications requires further study. Using machine learning, we aimed to develop predictive models for complete occlusion after off-label WEB treatment and to identify factors associated with occlusion outcomes. METHODS: This multicenter, retrospective study included 162 patients who underwent off-label WEB treatment for intracranial aneurysms. Baseline, morphological, and procedural variables were utilized to develop machine-learning models predicting complete occlusion. Model interpretation was performed to determine significant predictors. Ordinal regression was also performed with occlusion status as an ordinal outcome from better (Raymond Roy Occlusion Classification [RROC] grade 1) to worse (RROC grade 3) status. Odds ratios (OR) with 95 % confidence intervals (CI) were reported. RESULTS: The best performing model achieved an AUROC of 0.8 for predicting complete occlusion. Larger neck diameter and daughter sac were significant independent predictors of incomplete occlusion. On multivariable ordinal regression, higher RROC grades (OR 1.86, 95 % CI 1.25-2.82), larger neck diameter (OR 1.69, 95 % CI 1.09-2.65), and presence of daughter sacs (OR 2.26, 95 % CI 0.99-5.15) were associated with worse aneurysm occlusion after WEB treatment, independent of other factors. CONCLUSION: This study found that larger neck diameter and daughter sacs were associated with worse occlusion after WEB therapy for aneurysms. The machine learning approach identified anatomical factors related to occlusion outcomes that may help guide patient selection and monitoring with this technology. Further validation is needed.

4.
Acta Neurochir (Wien) ; 165(8): 2077-2086, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37365349

RESUMO

BACKGROUND: Utilization of Woven EndoBridge (WEB) for treatment of intracranial aneurysms has increased due to increasing operator experience. We aimed to report our contemporary series of a North American center with the WEB, examining factors associated with occlusion rates. METHOD: Consecutive patients (2019-2022) with intracranial aneurysms treated with WEB device were included. Through a univariate and multivariate analysis, independent predictors of adequate occlusion (RR1/RR2) were examined. Procedural and clinical results were reported. RESULTS: A total of 104 consecutive aneurysms/patients (25 men/79 women; median age, 63 years, IQR: 55-71) were treated with single-layer WEB-SL in our institution. Seventeen patients (16%) had a ruptured aneurysm. The median aneurysm dome size was 5.5 mm (IQR = 4.5-6.5), and the most common locations were AcomA (36/104 = 34.6%), MCA bifurcation (29/104 = 27.9%), and BT (22/104 = 21.2%). The rate of technical failure was 0.9%. The median intervention time was 32 min (IQR = 25-43). Overall, 8 (7.6%) cases needed additional interventions: 4 (3.8%) additional stenting, 3 cases (3.8%) of intravenous tirofiban infusion (because of the excessive WEB protrusion), and one case (0.9%) of additional coiling (need to complete the neck occlusion). At 12-month follow-up, 67 patients were available showing 59/67 (88%) and 6/67 (9%) of complete occlusion and neck remnant, respectively on dual-energy CTA. There were no cases necessitating retreatment. Ruptured presentation (OR = 0.09, 95% CI = 0.008-0.9, p = .024), undersized WEB (OR = 15, 95% CI = 1.2-50, p = .006), WEB shape change (OR = 0.07, 95% CI = 0.001-0.6, p = .05), aneurysm neck diameter (OR = 0.4, 95% CI = 0.2-0.9, p = .05), and angle between the parent artery and the aneurysm dome (OR = 0.2, 95% CI = 0.01-0.8, p = .008) were significantly associated with occlusion status (RR1-2) at follow-up. However, in the multivariate logistic regression, these factors did not reach the statistical significance. The overall rate of morbidity was 0.9%. CONCLUSIONS: Our contemporary North American experience on consecutive intracranial aneurysms treated with WEB confirms the medium-term efficacy of this strategy, with low procedural time and morbidity. Further research is needed to demonstrate long-term occlusion rates.


Assuntos
Aneurisma Roto , Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Resultado do Tratamento , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Estudos Retrospectivos , Procedimentos Endovasculares/métodos , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/cirurgia , Embolização Terapêutica/métodos , América do Norte
5.
Acta Neurochir (Wien) ; 165(7): 1869-1879, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37289301

RESUMO

BACKGROUND: The Woven Endobridge (WEB) is designed to treat intracranial wide-neck bifurcation aneurysms, preventing subarachnoid hemorrhage. The translational value of animal models used for WEB device testing is unknown. With this systematic review, we aim to identify the existing animal models used in testing the WEB device and compare the efficacy and safety outcomes to those of prospective clinical studies. METHODS: This study was funded by ZonMw: project number 114024133. A comprehensive search was performed in PubMed and in EMBASE via the Ovid interface. The following exclusion criteria were used: 1) not an original full-length research paper, 2) not an in vivo animal study or a human study, 3) no WEB implantation, 4) if in humans: not a prospective study. The SYRCLE risk of bias tool (animal studies) and the Newcastle-Ottawa quality assessment scale for cohort studies (clinical studies) were used to assess risks of bias. A narrative synthesis was performed. RESULTS: Six animal studies and 17 clinical studies met the inclusion criteria. The rabbit elastase aneurysm model was the only animal model used to assess WEB device performance. Safety outcomes were never reported in animal studies. Efficacy outcomes were more heterogeneous in animal studies than in clinical studies, which could be due to limited external validity of the animal models in terms of aneurysm induction and dimensions. Both animal and clinical studies were predominantly single-arm studies, and were at unclear risk of several types of bias. CONCLUSIONS: The rabbit elastase aneurysm model was the only pre-clinical animal model used to assess WEB device performance. Safety outcomes were not evaluated in animal studies and could therefore not be compared to clinical outcomes. Efficacy outcomes were more heterogeneous in animal studies than in clinical studies. Future research should focus on improving methodology and reporting in order to draw accurate conclusions on the performance of the WEB device.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Animais , Humanos , Coelhos , Resultado do Tratamento , Estudos Prospectivos , Procedimentos Endovasculares/métodos , Embolização Terapêutica/métodos , Aneurisma Intracraniano/terapia , Modelos Animais , Estudos Retrospectivos
6.
Acta Neurochir (Wien) ; 165(7): 1881-1889, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37178247

RESUMO

BACKGROUND: Since its approval by the US Food and Drug Administration (FDA) in 2018, the flow disruptor Woven EndoBridge (WEB) device has become increasingly popular for the endovascular treatment of unruptured and ruptured cerebral aneurysms. However, the occlusion rates seem rather low and the retreatment rates rather high compared to other treatment methods. For initially ruptured aneurysms, a retreatment rate of 13 % has been reported. A variety of retreatment strategies has been proposed; however, there is a paucity of data concerning microsurgical clipping of WEB-pretreated aneurysms, especially previously ruptured ones. Thus, we present a single-center series of five ruptured aneurysms treated with the WEB device and retreated with microsurgical clipping. METHODS: A retrospective study including all patients presenting with a ruptured aneurysm undergoing WEB treatment at our institution between 2019 and 2021 was performed. Subsequently, all patients with an aneurysm remnant or recurrence of the target aneurysm retreated with microsurgical clipping were identified. RESULTS: Overall, five patients with a ruptured aneurysm treated with WEB and retreated with microsurgical clipping were included. Besides one basilar apex aneurysm, all aneurysms were located at the anterior communicating artery (AComA) complex. All aneurysms were wide-necked with a mean dome-to-neck ratio of 1.5. Clipping was feasible and safe in all aneurysms, and complete occlusion was achieved in 4 of 5 aneurysms. CONCLUSIONS: Microsurgical clipping for initially ruptured WEB-treated aneurysms is a feasible, safe, and effective treatment method in well-selected patients.


Assuntos
Aneurisma Roto , Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Estudos Retrospectivos , Procedimentos Endovasculares/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Resultado do Tratamento , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/cirurgia , Embolização Terapêutica/métodos , Retratamento
7.
J Neuroradiol ; 50(5): 518-522, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36868371

RESUMO

BACKGROUND: Safety and efficacy of the WEB (Woven EndoBridge) device have been extensively evaluated in several good clinical practice studies. Nonetheless, the WEB had several structural evolutions overtime up to the fifth generation WEB device (WEB17). Here, we tried to understand how this may have modified our practices and enlarged our indications for its use. METHODS: We retrospectively analyzed data from all patients with aneurysms treated (or intended to be treated) with a WEB at our institution between July 2012 and February 2022. The time frame was split in two periods: before and after the arrival of the WEB17 in our center (February 2017). RESULTS: 252 patients with 276 wide-necked aneurysms were included; 78 aneurysms (28.2%) were ruptured. Successful embolization with a WEB device was achieved in 263/276 aneurysms (95.3%). With the availability of WEB17, treated aneurysms were significantly smaller (8.2 mm versus 5.9 mm, p<0.001) and off-label location significantly increased (4.4% versus 17.3%, p = 0.02) with an increase of sidewall aneurysm (4.4% versus 11.6%, p = 0.06). Also, WEB were more significantly oversized (1.05 versus 1.11, p<0.01). Adequate and complete occlusion rates increased constantly during the two periods (54.8% versus 67.5%, p = 0.08 and 74.2% versus 83.7%, p = 0.10, respectively). The proportion of ruptured aneurysms slightly increased between the two periods (24.6% versus 29.5%, p = 0.44). CONCLUSIONS: Over the first decade of its availability, the WEB device usage shifted towards smaller aneurysms and broader indications, including ruptured aneurysms. The oversizing strategy also became the standard of practice for WEB deployment in our institution.


Assuntos
Aneurisma Roto , Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Resultado do Tratamento , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Estudos Retrospectivos , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/terapia
8.
Neurosurg Rev ; 45(4): 2717-2722, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35403981

RESUMO

The Woven EndoBridge device (WEB) was introduced in 2010 to treat wide-neck bifurcation aneurysms (WNBAs). Three landmark studies have been conducted to assess its safety and efficacy: WEBCAST, WEBCAST 2, and French Observatory Study. However, these studies have not compared its safety and efficacy to other treatment modalities. In this study, we compare WEB versus microsurgical clipping in the management of unruptured WNBA. We conducted a retrospective study of unruptured WNBA meeting the morphological criteria to be amenable for WEB treatment operated on at our institution. Surgical morbidity, mortality, and occlusion rates were assessed. We compared our results to those reported in the cumulative population of the three WEB landmark studies at 1 year. A total of 84 patients with 89 WNBA were included. The most common aneurysm location was the middle cerebral artery bifurcation (n = 67/89, 75%). No operative mortality was observed. Morbidity comprised small-vessel vasospasm (n = 1/89, 1%) resulting in hemiparesis vs. 3% morbidity for WEB (p = .324). All but one (n = 1/89, 1%) WNBA were completely occluded vs WEB occlusion rate of 53% at 1 year, statistically significantly worse (p < .001). In our analysis, we were not able to show superiority of WEB in terms of procedural morbidity in comparison to microsurgical clipping, defined as worsening in mRS. Microsurgical clipping achieves statistically significantly higher rates of complete aneurysm occlusion, thus posing the question of whether the WEB should be presented as a viable, comparable alternative to patients amenable to surgical treatment.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Embolização Terapêutica/métodos , Procedimentos Endovasculares/métodos , Humanos , Aneurisma Intracraniano/terapia , Estudos Retrospectivos , Resultado do Tratamento
9.
Acta Neurochir (Wien) ; 164(8): 2181-2190, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35037115

RESUMO

PURPOSE: Woven Endobridge (WEB) embolization has become a well-established endovascular treatment option for wide-necked bifurcation aneurysms. The objective was to analyse cases that required additional stent-implantation. METHODS: Images of 178 aneurysms ≤ 11 mm treated by WEB only or by WEB plus stent were retrospectively reviewed, evaluating aneurysm characteristics, procedural specifics, adverse events and angiographic results. Moreover, we report a case of a WEB delivered through a previously implanted stent. RESULTS: Additional stent implantation was performed in 15 patients (8.4%). Baseline patient and aneurysm characteristics were comparable between both groups. A single stent was used in 12 cases and 2 stents in Y-configuration in 3. Thromboembolic complications occurred more often with stent assistance (33.3% vs. 8.0%, p = 0.002), while ischemic stroke rates were comparable between both groups (0% vs. 1.8%, p = 1.0). Six-month angiographic follow-up showed complete occlusion, neck remnants and aneurysm remnants in 73.4%, 19.4% and 7.3% after WEB only, respectively, and in 66.7%, 20.0% and 16.7% after WEB plus stent, respectively (p = 0.538). A case report shows that WEB deployment through the struts of a previously implanted standard microstent is feasible, even if a VIA 33 microcatheter is needed. CONCLUSION: In the present study, stent-assisted WEB embolization had a comparable safety and efficacy profile compared to treatment by WEB only. However, stent-assisted WEB embolization requires long-term anti-platelet medication, which annihilates the advantages of the WEB as a purely intrasaccular device. CLINICAL TRIAL REGISTRATION NUMBER: N/A.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Embolização Terapêutica/efeitos adversos , Procedimentos Endovasculares/métodos , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Estudos Retrospectivos , Stents/efeitos adversos , Resultado do Tratamento
10.
Neuroradiology ; 63(11): 1891-1899, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34031704

RESUMO

PURPOSE: The Woven EndoBridge (WEB) can be used to treat wide-necked aneurysms without antiplatelet medications, suggesting it may have advantages in the setting of aneurysmal subarachnoid hemorrhage (aSAH). The goal was assessment of safety and efficacy of WEB in aSAH given the delayed nature of aneurysmal thrombosis. METHODS: An international retrospective analysis of patients with aSAH treated with WEB was conducted at 7 tertiary centers from 2016 to 2020. Outcomes included rates of rebleeding, retreatment, complications, and complete occlusion. Furthermore, a systematic review and meta-analysis was conducted from 2011 to 2020 assessing the same outcomes. All pooled event rates were calculated using a random effect model. RESULTS: Consecutive patients with aSAH harbored 25 aneurysms that were treated with 29 WEB devices. The mean age was 53 years, and 65% were female. Zero experienced rebleeding, 2 were retreated, 2 experienced complications, 16 were completely occluded at 3 months, and 21 were completed occluded at 9-12 months. Meta-analysis of 309 WEB treatments for aSAH from 7 case series revealed 2.5% (95% CI 1-5%) had rebleeding, 9% (95% CI 4-17%) were retreated, 17% (95% CI 10-30%) had complications, and 61% (95% CI 51-71%) were completely occluded at 3-6 months. CONCLUSION: WEB embolization in the setting of aSAH provides similar protection against rebleeding with comparable retreatment rates to traditional approaches. However, there is a higher rate of incomplete radiographic occlusion and operative complications compared to WEB embolization of unruptured aneurysms. Long-term prospective studies are needed to fully delineate the role of WEB embolization in aSAH.


Assuntos
Aneurisma Roto , Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/terapia , Feminino , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Pessoa de Meia-Idade , Estudos Multicêntricos como Assunto , Estudos Retrospectivos , Resultado do Tratamento
11.
Acta Neurochir (Wien) ; 161(8): 1507-1513, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31240584

RESUMO

BACKGROUND: WEB (Woven EndoBridge) device is an intrasaccular flow diverter designed for endovascular treatment of intracranial aneurysms. Recent clinical trials showed good feasibility, safety, and efficacy profiles. In most of the published studies however, aneurysms treated with adjunctive devices other than WEB such as coils or stents were included which might make it difficult to reflect the real potential of this device. The purpose of this single-center study was to present the results of ruptured and unruptured aneurysms treated only with WEB device. METHOD: Between April 2013 and July 2018, 47 (ruptured, 12; 25.5%) intracranial aneurysms treated only with WEB and a follow-up of at least 3 months were included in the study. Angiographic outcome at follow-up, peri-procedural complication rate, and rate of retreatment were recorded. RESULTS: Of the 47 aneurysms, 12 (25.5%) were ruptured. The mean size of the aneurysms was 6.3 mm (ruptured, 5.4 mm; unruptured, 6.6 mm). Median follow-up period was 9 months. Complete occlusion was observed in 26/47 aneurysms (55.3%; ruptured, 66.6%; unruptured, 51.4%). Thirteen aneurysms (27.6%; ruptured, 16.6%; unruptured, 31.4%) showed a neck remnant. In 4/47 aneurysms (8.5%; ruptured, 8%; unruptured, 8.5%), persistent contrast enhancement inside the WEB was recorded. In 4/47 patients (8.5%; ruptured, 8%; unruptured, 8.5%), an aneurysm remnant was noted. Adequate occlusion (complete occlusion and neck remnant) was observed in 43/47 aneurysms (91.4%; ruptured, 91.6%; unruptured, 91.4%). Retreatment rate was 6.3% (ruptured, 8%; unruptured, 5.7%). Six (12.7%; ruptured, 25%; unruptured, 8.5%) thromboembolic events were recorded. Hemorrhagic complications occurred in two patients (4.2%; ruptured, 16.6%; unruptured, 0%). CONCLUSIONS: WEB enables adequate occlusion of ruptured and unruptured intracranial aneurysms mostly without requirement of long-term antiplatelet therapy. The benefit is seen especially by the wide-necked aneurysms, but indications should be extended to include narrow-necked, smaller, and side-wall aneurysms.


Assuntos
Aneurisma Roto/cirurgia , Prótese Vascular , Procedimentos Endovasculares/métodos , Aneurisma Intracraniano/cirurgia , Adulto , Idoso , Feminino , Seguimentos , Humanos , Aneurisma Intracraniano/complicações , Hemorragias Intracranianas/etiologia , Masculino , Pessoa de Meia-Idade , Inibidores da Agregação Plaquetária/uso terapêutico , Recidiva , Estudos Retrospectivos , Stents , Tromboembolia/complicações , Resultado do Tratamento
12.
J Neuroradiol ; 45(6): 343-348, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29524499

RESUMO

BACKGROUND AND PURPOSE: The WEB is an innovative flow disruption device for cerebral aneurysm embolization with rapidly expanding indications. Our purpose was to evaluate the diagnostic performance of computed tomography angiography (CTA) at 1-year follow-up of aneurysms treated with the WEB. MATERIALS AND METHODS: Between April 2014 and May 2016, the study prospectively included patients treated with the WEB at our institution, and followed up within 24hours by CTA and at 1year by CTA, time-of-flight magnetic resonance angiography (TOF MRA) and digital subtraction angiography (DSA). The diagnostic quality of imaging data was assessed based on the confidence index, artifacts, and WEB shape depiction. The imaging diagnostic performance was assessed using 3 criteria at 1year: aneurysm occlusion status and worsening, and WEB shape compression. Interobserver and intermodality agreement was determined by calculating κ values. RESULTS: The study ultimately included 16 patients (9 women, mean age 53±7.6years). CTA quality confidence was scored as 2/2, artifacts 0.4/2 and WEB shape depiction 1.9/2, superior to TOF MRA for the latter two criteria. Aneurysm occlusion was adequate in 93.7% of patients, with CTA showing excellent interobserver reproducibility and agreement with DSA on a 4-grade scale (κ=1.00), while TOF MRA yielded good reproducibility (κ=0.76) and agreement with DSA (κ=0.69). CTA also identified aneurysm occlusion worsening (43.7%) and WEB compression (81.2%) in excellent agreement with DSA (κ=0.85 and 1.00). CONCLUSIONS: CTA is a reproducible and reliable technique for the follow-up of aneurysms treated with the WEB device.


Assuntos
Angiografia por Tomografia Computadorizada , Embolização Terapêutica/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Adulto , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes , Resultado do Tratamento
13.
Neurosurg Focus ; 42(6): E2, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28565980

RESUMO

Flow diversion has become a well-accepted option for the treatment of cerebral aneurysms. Given the significant treatment effect of flow diverters, numerous options have emerged since the initial Pipeline embolization device studies. In this review, the authors describe the available flow diverters, both endoluminal and intrasaccular, addressing nuances of device design and function and presenting data on complications and outcomes, where available. They also discuss possible future directions of flow diversion.


Assuntos
Procedimentos Endovasculares , Aneurisma Intracraniano/terapia , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/métodos , Procedimentos Endovasculares/tendências , Humanos , Resultado do Tratamento
14.
Neuroradiology ; 58(9): 887-91, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27312475

RESUMO

INTRODUCTION: The Woven EndoBridge (WEB) system is an innovative device under evaluation for its capacity to treat wide-neck bifurcation intracranial aneurysms. The purpose of this study is to evaluate the use of the different occlusion scales available in clinical practice. METHODS: Seven WEB-experienced neurointerventionalists were provided with 30 angiographic follow-up data sets and asked to grade each evaluation point according to the Bicêtre Occlusion Scale Score (BOSS), firstly based on DSA images only then using additional C-Arm VasoCT analysis. This BOSS evaluation was then converted into the WEB Occlusion Scale (WOS) and into a dichotomized scale (complete occlusion or not). To estimate the inter-rater agreement among the seven raters, an overall kappa coefficient [1] and its standard error (SE) were computed. RESULTS: Using the five-grade BOSS, raters showed "moderate" agreement (kappa = 0.56). Using the three-grade WOS, agreement appeared slightly better (kappa = 0.59). Strongest inter-rater agreement was observed with a dichotomized version of the scale (complete occlusion or not), which enabled an "almost perfect" agreement (kappa = 0.88). VasoCT consistently enhanced the agreement particularly with regards depicting intra-WEB residual filling. CONCLUSION: The WOS is a consistent means to angiographically evaluate the WEB device efficiency. But the five-grade BOSS scale allows to identify aneurysm subgroups with differing risks of recurrence and/or rehemorrhage, which needs to be separated especially at the initial phase of evaluation of this innovative device. The additional use of VasoCT allows better inter-rater agreement in evaluating occlusion and specially in depicting intra-WEB persistent filling.


Assuntos
Prótese Vascular , Angiografia Cerebral/métodos , Angiografia por Tomografia Computadorizada/métodos , Procedimentos Endovasculares/instrumentação , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Stents , Análise de Falha de Equipamento , Humanos , Desenho de Prótese , Resultado do Tratamento
15.
Interv Neuroradiol ; : 15910199241240504, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38529582

RESUMO

The Woven EndoBridge (WEB) is an intra-aneurysmal flow disruptor designed for the treatment of broad-based arterial aneurysms with a high safety and effectiveness profile.1, 2 It does not require concomitant antiplatelet therapy compared to other devices such as flow diverters or intracranial stents. Innominate artery pseudoaneurysms are a rare consequence of blunt traumatic injury, infection, or atherosclerotic disease.3, 4 We describe the case of an innominate artery pseudoaneurysm successfully treated with a WEB SL device instead of stenting, therefore alleviating the need for dual antiplatelet therapy. The treatment was successful and uneventful and postprocedural computed tomography angiography confirmed the complete occlusion of the pseudoaneurysm.

16.
Neuroradiol J ; 37(5): 564-570, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38501764

RESUMO

BACKGROUND: The Woven EndoBridge (WEB) device is a minimally invasive endovascular treatment option for patients with cerebral aneurysms. Transradial access (TRA) is a technique that involves accessing the arterial system through the radial artery in the wrist rather than the femoral artery in the groin. Several studies have investigated the use of TRA for WEB device deployment in treating intracranial aneurysms. METHODS: A systematic review was conducted to evaluate the TRA for WEB device deployment in treating intracranial aneurysms. The databases PubMed, Cochrane, Embase, Scopus, and Web of Science were searched. To reduce the risk of bias, this systematic review only included studies reporting on using TRA in WEB device deployment for intracranial aneurysm treatment with a minimum of four patients. RESULTS: In this systematic review, 186 patients were included across five studies, with TRA used in 183 cases analyzed. The study population had a higher proportion of females (n = 118%-69%) than males, with a mean age of 62 years old. Among the aneurysms treated, 46 were ruptured, and 119 were located at bifurcation sites, with a mean maximum diameter/width of 6.6 mm and mean height of 5.9 mm. Adjunctive coiling was used in three cases, and adjunctive stenting was used in nine cases. In two cases, conversion to a femoral artery access was necessary. CONCLUSION: The available results suggest TRA with the WEB device is a safe and effective alternative. However, using TRA versus TFA should be individualized based on patient factors and operator experience.


Assuntos
Procedimentos Endovasculares , Aneurisma Intracraniano , Artéria Radial , Humanos , Aneurisma Intracraniano/cirurgia , Aneurisma Intracraniano/terapia , Aneurisma Intracraniano/diagnóstico por imagem , Procedimentos Endovasculares/métodos , Procedimentos Endovasculares/instrumentação , Artéria Radial/cirurgia , Embolização Terapêutica/métodos , Embolização Terapêutica/instrumentação , Stents
17.
World Neurosurg ; 188: e168-e176, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38763461

RESUMO

BACKGROUND: The Woven EndoBridge (WEB) is a device used for intrasaccular flow diversion, designed for the elimination of wide-necked bifurcation aneurysms from the circulation. In this study, we aim to assess the safety and efficacy of the WEB and its uses in treating aneurysms of different morphologies and locations. METHODS: In a retrospective analysis, we compiled a comprehensive dataset from patients treated with the WEB device across three major Australian neurovascular centers from May 2017 to September 2023. The case series encompassed a spectrum of aneurysm types, including wide-necked bifurcation, sidewall, and irregularly shaped aneurysms, as well as cases previously managed with alternative therapeutic strategies. This study additionally encompasses cases where aneurysms were managed using the WEB device in combination with supplementary endovascular devices. RESULTS: The study included 169 aneurysms in 161 patients. The rate of satisfactory aneurysm occlusion was 85.6%, with 86.7% of patients maintaining good functional status at their most recent follow-up. The procedure exhibited a low mortality rate of 0.6% and a thromboembolic complication rate of 7.1% (n = 12/161). There were no instances of postoperative re-rupture and the procedure-related hemorrhage rate was low (1.2%, n = 2/169), aligning with the literature regarding the safety and efficacy of the WEB device. CONCLUSIONS: Our multicenter trial reinforces the WEB device's role as an effective and safe modality for intracranial aneurysm management, supporting its expanded application beyond wide-necked bifurcation aneurysms. Further prospective studies are required to delineate its evolving role fully.


Assuntos
Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/cirurgia , Aneurisma Intracraniano/terapia , Aneurisma Intracraniano/diagnóstico por imagem , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Procedimentos Endovasculares/métodos , Procedimentos Endovasculares/instrumentação , Idoso , Resultado do Tratamento , Adulto , Complicações Pós-Operatórias/epidemiologia , Idoso de 80 Anos ou mais , Embolização Terapêutica/instrumentação , Embolização Terapêutica/métodos
18.
Interv Neuroradiol ; : 15910199241236818, 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38613373

RESUMO

INTRODUCTION: Endovascular treatment of wide neck aneurysms remains complicated with a determined and continuous technological effort towards treatment options that can offer safer and efficacious outcomes. The Woven Endobridge device was introduced in 2010 and has become a mainstay endovascular treatment for wide neck and large intracranial aneurysms. A recent review of the Woven Endobridge Clinical Assessment of Intrasaccular Aneurysm Therapy (WEBCAST) and WEBCAST2 trials and the five-year follow-up of patients was published. Our aim is to demonstrate real-life experience of aneurysms and patients treated with Woven Endobridge from a large high-volume specialist centre. METHODS: A retrospective review was performed of patients treated with Woven Endobridge from March 2013 to March 2018. Primary efficacy outcomes were defined as per Raymond-Roy Occlusion Criteria (RROC) resulting in long-term complete occlusion (RROC1) and adequate occlusion (RROC1 and RROC2). Primary Safety outcomes were defined as procedure-related morbidity, rate of re-bleeding and rate of re-treatment. RESULTS: Seventy-nine aneurysms were treated during the five-year period. Adequate aneurysm occlusion (RROC1 and RROC2) achieved was 81%. Retreatment was required in 18% of patients (14/79). Greater retreatment rate was demonstrated in partially thrombosed aneurysms, aneurysms with larger neck and dome diameter and dome heights. CONCLUSION: Woven Endobridge treatment of wide-neck intracranial aneurysms offers a safe and efficacious outcome. This large UK single-centre experience demonstrates congruity with recent five-year outcomes of WEBCAST and WEBCAST2 trials.

19.
J Neurosurg ; 140(4): 1071-1079, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37862717

RESUMO

OBJECTIVE: The Woven EndoBridge (WEB) device is an intrasaccular flow disruptor designed for wide-necked bifurcation aneurysms. These aneurysms may require the use of a concomitant stent. The objective of this study was to determine the clinical and radiological outcomes of patients undergoing stent-assisted WEB treatment. In addition, the authors also sought to determine the predictors of a concomitant stent in aneurysms treated with the WEB device. METHODS: The data for this study were taken from the WorldWideWEB Consortium, an international multicenter cohort including patients treated with the WEB device. Aneurysms were classified into two groups based on treatment: stent-assisted WEB and WEB device alone. The authors compared clinical and radiological outcomes of both groups. Univariable and multivariable binary logistic regression analyses were performed to determine factors that predispose to stent use. RESULTS: The study included 691 intracranial aneurysms (31 with stents and 660 without stents) treated with the WEB device. The adequate occlusion status did not differ between the two groups at the latest follow-up (83.3% vs 85.6%, p = 0.915). Patients who underwent stenting had more thromboembolic (32.3% vs 6.5%, p < 0.001) and procedural (16.1% vs 3.0%, p < 0.001) complications. Aneurysms treated with a concomitant stent had wider necks, greater heights, and lower dome-to-neck ratios. Increasing neck size was the only significant predictor for stent use. CONCLUSIONS: This study demonstrates that there is no difference in the degree of aneurysm occlusion between the two groups; however, complications were more frequent in the stent group. In addition, a wider aneurysm neck predisposes to stent assistance in WEB-treated aneurysms.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Resultado do Tratamento , Estudos Retrospectivos , Stents
20.
J Neurosurg ; 141(4): 992-999, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-38701528

RESUMO

OBJECTIVE: This study was conducted to investigate the impact of antiplatelet administration in the periprocedural period on the occurrence of thromboembolic complications (TECs) in patients undergoing treatment using the Woven EndoBridge (WEB) device for intracranial wide-necked bifurcation aneurysms. The primary objective was to assess whether the use of antiplatelets in the pre- and postprocedural phases reduces the likelihood of developing TECs, considering various covariates. METHODS: A retrospective multicenter observational study was conducted within the WorldWideWEB Consortium and comprised 38 academic centers with endovascular treatment capabilities. Univariable and multivariable logistic regression analyses were performed to determine the association between antiplatelet use and TECs, adjusting for covariates. Missing predictor data were addressed using multiple imputation. RESULTS: The study comprised two cohorts: one addressing general thromboembolic events and consisting of 1412 patients, among whom 103 experienced TECs, and another focusing on symptomatic thromboembolic events and comprising 1395 patients, of whom 50 experienced symptomatic TECs. Preprocedural antiplatelet use was associated with a reduced likelihood of overall TECs (OR 0.32, 95% CI 0.19-0.53, p < 0.001) and symptomatic TECs (OR 0.49, 95% CI 0.25-0.95, p = 0.036), whereas postprocedural antiplatelet use showed no significant association with TECs. The study also revealed additional predictors of TECs, including stent use (overall: OR 4.96, 95% CI 2.38-10.3, p < 0.001; symptomatic: OR 3.24, 95% CI 1.26-8.36, p = 0.015), WEB single-layer sphere (SLS) type (overall: OR 0.18, 95% CI 0.04-0.74, p = 0.017), and posterior circulation aneurysm location (symptomatic: OR 18.43, 95% CI 1.48-230, p = 0.024). CONCLUSIONS: The findings of this study suggest that the preprocedural administration of antiplatelets is associated with a reduced likelihood of TECs in patients undergoing treatment with the WEB device for wide-necked bifurcation aneurysms. However, postprocedural antiplatelet use did not show a significant impact on TEC occurrence.


Assuntos
Procedimentos Endovasculares , Aneurisma Intracraniano , Inibidores da Agregação Plaquetária , Tromboembolia , Humanos , Inibidores da Agregação Plaquetária/administração & dosagem , Inibidores da Agregação Plaquetária/uso terapêutico , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Tromboembolia/prevenção & controle , Tromboembolia/etiologia , Idoso , Procedimentos Endovasculares/métodos , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/epidemiologia , Adulto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA