Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 619
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
J Microsc ; 294(3): 319-337, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38683038

RESUMO

Developing devices and instrumentation in a bioimaging core facility is an important part of the innovation mandate inherent in the core facility model but is a complex area due to the required skills and investments, and the impossibility of a universally applicable model. Here, we seek to define technological innovation in microscopy and situate it within the wider core facility innovation portfolio, highlighting how strategic development can accelerate access to innovative imaging modalities and increase service range, and thus maintain the cutting edge needed for sustainability. We consider technology development from the perspective of core facility staff and their stakeholders as well as their research environment and aim to present a practical guide to the 'Why, When, and How' of developing and integrating innovative technology in the core facility portfolio. Core facilities need to innovate to stay up to date. However, how to carry out the innovation is not very obvious. One area of innovation in imaging core facilities is the building of optical setups. However, the creation of optical setups requires specific skill sets, time, and investments. Consequently, the topic of whether a core facility should develop optical devices is discussed as controversial. Here, we provide resources that should help get into this topic, and we discuss different options when and how it makes sense to build optical devices in core facilities. We discuss various aspects, including consequences for staff and the relation of the core to the institute, and also broaden the scope toward other areas of innovation.


Assuntos
Invenções , Microscopia/métodos , Microscopia/instrumentação
2.
Bioelectromagnetics ; 45(2): 33-47, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37789661

RESUMO

Uninterrupted microscopic observation and real-time imaging of cell behavior during exposure to the stimulus, for example, electric and/or magnetic fields, especially for periods of several days, has been a challenge in experimental bioelectromagnetics due to a lack of proper gas/temperature conditions outside the incubator. Conventional mini-incubators might suffer from stray fields produced by heating elements. We report an in vitro electric and magnetic fields (EMF) exposure system embedded inside a novel under-the-microscope mini-CO2 -incubator with a unique design to avoid electromagnetic interference from the heating and circulation functions while ensuring the requisite temperature. A unique, reconfigurable array of electrodes and/or coils excited by calculated current distributions among array elements is designed to provide excellent field uniformity and controllable linear or circular polarization (even at very low frequencies) of the EMF within the cell culture. Using standard biochemical assays, long-term cell viability has been verified and compared with a conventional incubator. Cell orientation/migration in three-dimensional culture made of collagen-hydrogels has been successfully observed in vitro, in long-term, and in real-time under the influence of DC electric fields with the device.


Assuntos
Campos Eletromagnéticos , Campos Magnéticos , Incubadoras , Temperatura , Eletricidade
3.
Artigo em Inglês | MEDLINE | ID: mdl-38964992

RESUMO

Massive hemoptysis is a time critical airway emergency in the perioperative setting, with an associated mortality exceeding 50%. Causes of hemoptysis in the perioperative setting include procedural complication, coagulopathy, malignancy, chronic lung disease, infection, left-sided cardiac disease, pulmonary vascular disease and autoimmune disease. A rapid and coordinated multidisciplinary response is required to secure the airway, isolate the lung, ensure adequate oxygenation and ventilation, identify the underlying cause and initiate specific systemic, bronchoscopic, endovascular, or surgical treatment. This review examines the etiology, pathophysiology, as well as approach to management and interventions in perioperative massive hemoptysis.

4.
J Appl Clin Med Phys ; 25(7): e14319, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38522035

RESUMO

BACKGROUND AND PURPOSE: By employing three surface-guided radiotherapy (SGRT)-assisted positioning methods, we conducted a prospective study of patients undergoing SGRT-based deep inspiration breath-hold (DIBH) radiotherapy using a Sentine/Catalys system. The aim of this study was to optimize the initial positioning workflow of SGRT-DIBH radiotherapy for breast cancer. MATERIALS AND METHODS: A total of 124 patients were divided into three groups to conduct a prospective comparative study of the setup accuracy and efficiency for the daily initial setup of SGRT-DIBH breast radiotherapy. Group A was subjected to skin marker plus SGRT verification, Group B underwent SGRT optical feedback plus auto-positioning, and Group C was subjected to skin marker plus SGRT auto-positioning. We evaluated setup accuracy and efficiency using cone-beam computed tomography (CBCT) verification data and the total setup time. RESULTS: In groups A, B, and C, the mean and standard deviation of the translational setup-error vectors were small, with the highest values of the three directions observed in group A (2.4 ± 1.6, 2.9 ± 1.8, and 2.8 ± 2.1 mm). The rotational vectors in group B (1.8 ± 0.7°, 2.1 ± 0.8°, and 1.8 ± 0.7°) were significantly larger than those in groups A and C, and the Group C setup required the shortest amount of time, at 1.5 ± 0.3 min, while that of Group B took the longest time, at 2.6 ± 0.9 min. CONCLUSION: SGRT one-key calibration was found to be more suitable when followed by skin marker/tattoo and in-room laser positioning, establishing it as an optimal daily initial set-up protocol for breast DIBH radiotherapy. This modality also proved to be suitable for free-breathing breast cancer radiotherapy, and its widespread clinical use is recommended.


Assuntos
Neoplasias da Mama , Suspensão da Respiração , Tomografia Computadorizada de Feixe Cônico , Posicionamento do Paciente , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Feminino , Neoplasias da Mama/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Estudos Prospectivos , Tomografia Computadorizada de Feixe Cônico/métodos , Pessoa de Meia-Idade , Radioterapia de Intensidade Modulada/métodos , Idoso , Radioterapia Guiada por Imagem/métodos , Erros de Configuração em Radioterapia/prevenção & controle , Adulto , Prognóstico , Marcadores Fiduciais , Órgãos em Risco/efeitos da radiação
5.
J Appl Clin Med Phys ; 25(1): e14217, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38018758

RESUMO

PURPOSE: Chest wall postmastectomy radiation therapy (PMRT) should consider the effects of chest wall respiratory motion. The purpose of this study is to evaluate the effectiveness of robustness planning intensity modulated radiation therapy (IMRT) for respiratory movement, considering respiratory motion as a setup error. MATERIAL AND METHODS: This study analyzed 20 patients who underwent PMRT (10 left and 10 right chest walls). The following three treatment plans were created for each case and compared. The treatment plans are a planning target volume (PTV) plan (PP) that covers the PTV within the body contour with the prescribed dose, a virtual bolus plan (VP) that sets a virtual bolus in contact with the body surface and prescribing the dose that includes the PTV outside the body contour, and a robust plan (RP) that considers respiratory movement as a setup uncertainty and performs robust optimization. The isocenter was shifted to reproduce the chest wall motion pattern and the doses were recalculated for comparison for each treatment plan. RESULT: No significant difference was found between the PP and the RP in terms of the tumor dose in the treatment plan. In contrast, VP had 3.5% higher PTV Dmax and 5.5% lower PTV V95% than RP (p < 0.001). The RP demonstrated significantly higher lung V20Gy and Dmean by 1.4% and 0.4 Gy, respectively, than the PP. The RP showed smaller changes in dose distribution affected by chest wall motion and significantly higher tumor dose coverage than the PP and VP. CONCLUSION: We revealed that the RP demonstrated comparable tumor doses to the PP in treatment planning and was robust for respiratory motion compared to both the PP and the VP. However, the organ at risk dose in the RP was slightly higher; therefore, its clinical use should be carefully considered.


Assuntos
Neoplasias da Mama , Radioterapia de Intensidade Modulada , Parede Torácica , Humanos , Feminino , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Planejamento da Radioterapia Assistida por Computador , Dosagem Radioterapêutica , Mastectomia
6.
J Appl Clin Med Phys ; 25(7): e14317, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38439583

RESUMO

PURPOSE: Patient setup errors have been a primary concern impacting the dose delivery accuracy in radiation therapy. A robust treatment plan might mitigate the effects of patient setup errors. In this reported study, we aimed to evaluate the impact of translational and rotational errors on the robustness of linac-based, single-isocenter, coplanar, and non-coplanar volumetric modulated arc therapy treatment plans for multiple brain metastases. METHODS: Fifteen patients were retrospectively selected for this study with a combined total of 49 gross tumor volumes (GTVs). Single-isocenter coplanar and non-coplanar plans were generated first with a prescribed dose of 40 Gy in 5 fractions or 42 Gy in 7 fractions to cover 95% of planning target volume (PTV). Next, four setup errors (+1  and +2 mm translation, and +1° and +2° rotation) were applied individually to generate modified plans. Different plan quality evaluation metrics were compared between coplanar and non-coplanar plans. 3D gamma analysis (3%/2 mm) was performed to compare the modified plans (+2 mm and +2° only) and the original plans. Paired t-test was conducted for statistical analysis. RESULTS: After applying setup errors, variations of all plan evaluation metrics were similar (p > 0.05). The worst case for V100% to GTV was 92.07% ± 6.13% in the case of +2 mm translational error. 3D gamma pass rates were > 90% for both coplanar (+2 mm and +2°) and the +2 mm non-coplanar groups but was 87.40% ± 6.89% for the +2° non-coplanar group. CONCLUSION: Translational errors have a greater impact on PTV and GTV dose coverage for both planning methods. Rotational errors have a greater negative impact on gamma pass rates of non-coplanar plans. Plan evaluation metrics after applying setup errors showed that both coplanar and non-coplanar plans were robust and clinically acceptable.


Assuntos
Neoplasias Encefálicas , Órgãos em Risco , Aceleradores de Partículas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Erros de Configuração em Radioterapia , Radioterapia de Intensidade Modulada , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/secundário , Radioterapia de Intensidade Modulada/métodos , Erros de Configuração em Radioterapia/prevenção & controle , Estudos Retrospectivos , Aceleradores de Partículas/instrumentação , Órgãos em Risco/efeitos da radiação , Prognóstico , Posicionamento do Paciente
7.
J Appl Clin Med Phys ; : e14469, 2024 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-39031843

RESUMO

PURPOSE: To evaluate the dosimetric impact on spatially fractionated radiation therapy (SFRT) plan quality due to intrafraction patient motion via multi-field MLC-based method for treating large and bulky (≥8 cm) unresectable tumors. METHODS: For large tumors, a cone beam CT-guided 3D conformal MLC-based SFRT method was utilized with 15 Gy prescription. An MLC GTV-fitting algorithm provided 1 cm diameter apertures with a 2 cm center-to-center distance at the isocenter. This generated a highly heterogeneous sieve-like dose distribution within an hour, enabling same-day SFRT treatment. Fifteen previously treated SFRT patients were analyzed (5 head & neck [H&N], 5 chest and lungs, and 5 abdominal and pelvis masses). For each plan, intrafraction motion errors were simulated by incrementally shifting original isocenters of each field in different x-, y-, and z-directions from 1 to 5 mm. The dosimetric metrics analyzed were: peak-to-valley-dose-ratio (PVDR), percentage of GTV receiving 7.5 Gy, GTV mean dose, and maximum dose to organs-at-risk (OARs). RESULTS: For ±1, ±2, ±3, ±4, and ±5 mm isocenter shifts: PVDR dropped by 3.9%, 3.8%, 4.0%, 4.1%, and 5.5% on average respectively. The GTV(V7.5) remained within 0.2%, and the GTV mean dose remained within 3.3% on average, compared to the original plans. The average PVDR drop for 5 mm shifts was 4.2% for H&N cases, 10% for chest and lung, and 2.2% for abdominal and pelvis cases. OAR doses also increased. The maximum dose to the spinal cord increased by up to 17 cGy in H&N plans, mean lung dose (MLD) changed was small for chest/lung, but the bowel dose varied up to 100 cGy for abdominal and pelvis cases. CONCLUSION: Due to tumor size, location, and characteristics of MLC-based SFRT, isocenter shifts of up to ±5 mm in different directions had moderate effects on PVDR for H&N and pelvic tumors and a larger effect on chest tumors. The dosimetric impact on OAR doses depended on the treatment site. Site-specific patient masks, Vac-Lok bags, and proper immobilization devices similar to SBRT/SRT setups should be used to minimize these effects.

8.
J Appl Clin Med Phys ; : e14480, 2024 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-39120606

RESUMO

OBJECTIVE: This study aims to analyze setup errors in pelvic Volumetric Modulated Arc Therapy (VMAT) for patients with non-surgical primary cervical cancer, utilizing the onboard iterative kV cone beam CT (iCBCT) imaging system on the Varian Halcyon 2.0 ring gantry structure accelerator to enhance radiotherapy precision. METHOD: We selected 132 cervical cancer patients who underwent VMAT with daily iCBCT imaging guidance. Before each treatment session, a registration method based on the bony structure was employed to acquire iCBCT images with the corresponding planning CT images. Following verification and adjustment of image registration results along the three axes (but not rotational), setup errors in the lateral (X-axis), longitudinal (Y-axis), and vertical (Z-axis) directions were recorded for each patient. Subsequently, we analyzed 3642 iCBCT image setup errors. RESULTS: The mean setup errors for the X, Y, and Z axes were 4.50 ± 3.79 mm, 6.08 ± 6.30 mm, and 1.48 ± 2.23 mm, respectively. Before correction with iCBCT, setup margins based on the Van Herk formula for the X, Y, and Z axes were 6.28, 12.52, and 3.26 mm, respectively. In individuals aged 60 years and older, setup errors in the X and Y axes were significantly larger than those in the younger group (p < 0.05). Additionally, there is no significant linear correlation between setup errors and treatment fraction numbers. CONCLUSION: Data analysis underscores the importance of precise Y-axis setup for cervical cancer patients undergoing VMAT. Radiotherapy centers without daily iCBCT should appropriately extend the planning target volume (PTV) along the Y-axis for cervical cancer patients receiving pelvic VMAT. Elderly patients exhibit significantly larger setup errors compared to younger counterparts. In conclusion, iCBCT-guided radiotherapy is recommended for cervical cancer patients undergoing VMAT to improve setup precision.

9.
World J Microbiol Biotechnol ; 40(4): 112, 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38416182

RESUMO

Organic agriculture is a sustainable method of farming, and confers disease-suppressing abilities to disease-conducive soils via specialized soil microbiomes. This study aimed at transforming a disease-conducive soil from a conventional field into disease-suppressive soil by inoculating soil from an organic field previously established as "disease-suppressive". The effectiveness of the transformed soil was established with the model plant wheat (Triticum aestivum) grown under natural conditions, with regard to its potential in inhibiting fungal phytopathogens, Rhizoctonia solani and Fusarium oxysporum. The conducive soil inoculated with the disease-suppressive soil performed better than the control conducive soil in terms of reduced disease severity in plants, improved soil nutrient content, increased activity of hydrolytic enzymes, and increased abundance of structural and functional microbial markers. The study demonstrates the efficacy of the soil microbiome under long-term organic agriculture in transforming disease-conducive soil into disease-suppressive soils. Such practises are simple and easy to implement, and could greatly improve the sustainability and crop yield in developing countries.


Assuntos
Microbiota , Solo , Agricultura , Fazendas , Hidrólise , Triticum
10.
Behav Res Methods ; 2024 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-39134828

RESUMO

When lab resources are shared among multiple research projects, issues such as experimental integrity, replicability, and data safety become important. Different research projects often need different software and settings that may well conflict with one another, and data collected for one project may not be safeguarded from exposure to researchers from other projects. In this paper we provide an infrastructure design and an open-source tool, labManager, that render multi-user lab facilities in the behavioral sciences accessible to research projects with widely varying needs. The solutions proposed ensure ease of management while simultaneously offering maximum flexibility by providing research projects with fully separated bare metal environments. This solution also ensures that collected data is kept separate, and compliant with relevant ethical standards and regulations such as General Data Protection Regulation (GDPR) legislation. Furthermore, we discuss preconditions for running shared lab facilities and provide practical advice.

11.
BMC Oral Health ; 24(1): 207, 2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38336704

RESUMO

BACKGROUND: To evaluate the outcome quality of manual and digital orthodontic diagnostic setups in non-extraction cases according to the American Board of Orthodontics model grading system and to calculate the laboratory time needed for orthodontic diagnostic setup construction. METHODS: The sample consisted of 60 pretreatment models of non-extraction orthodontic cases with age ranges of 18-30. The study models were duplicated and scanned with 3Shape R-750 scanner. Digital and manual diagnostic setups were constructed according to their respective treatment plans. Digital diagnostic setups were 3D printed and then both manual and digital setups were assessed using the modified American Board of Orthodontics Cast Radiograph evaluation score (ABO CRE), which includes alignment, marginal ridge, buccolingual inclination, occlusal contacts, occlusal relationships, interproximal contacts, and overjet. The laboratory time needed for orthodontic setups was measured in minutes. RESULTS: The total ABO CRE score of the digital diagnostic setup group (5.93 ± 2.74) was significantly lower than that of the manual diagnostic setup group (13.08 ± 3.25). The manual diagnostic setup had significantly larger scores in marginal ridge, overjet, overbite, buccolingual inclination, occlusal relationship, and total scores (P < 0.01). However, the digital diagnostic setup had a statistically larger occlusal contacts score than the manual diagnostic setup (P < 0.01). There was no significant difference between the alignment and the interproximal contacts scores in either group. The manual diagnostic setup needed significantly longer laboratory time (187.8 ± 14.22) than the digital setup (93.08 ± 12.65) (P < 0.01). Comparison between broken teeth was performed by using the chi-square test which found no significant difference between different tooth types. CONCLUSIONS: Digital diagnostic setup is a reliable tool for orthodontic diagnostic setup construction providing excellent quality setup models. Manual diagnostic setup is time consuming with a technique-sensitive laboratory procedure.


Assuntos
Má Oclusão Classe II de Angle , Ortodontia , Dente , Humanos , Estados Unidos , Má Oclusão Classe II de Angle/terapia
12.
Strahlenther Onkol ; 199(8): 739-748, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37285037

RESUMO

PURPOSE: Auxiliary devices such as immobilization systems should be considered in synthetic CT (sCT)-based treatment planning (TP) for MRI-only brain radiotherapy (RT). A method for auxiliary device definition in the sCT is introduced, and its dosimetric impact on the sCT-based TP is addressed. METHODS: T1-VIBE DIXON was acquired in an RT setup. Ten datasets were retrospectively used for sCT generation. Silicone markers were used to determine the auxiliary devices' relative position. An auxiliary structure template (AST) was created in the TP system and placed manually on the MRI. Various RT mask characteristics were simulated in the sCT and investigated by recalculating the CT-based clinical plan on the sCT. The influence of auxiliary devices was investigated by creating static fields aimed at artificial planning target volumes (PTVs) in the CT and recalculated in the sCT. The dose covering 50% of the PTV (D50) deviation percentage between CT-based/recalculated plan (∆D50[%]) was evaluated. RESULTS: Defining an optimal RT mask yielded a ∆D50[%] of 0.2 ± 1.03% for the PTV and between -1.6 ± 3.4% and 1.1 ± 2.0% for OARs. Evaluating each static field, the largest ∆D50[%] was delivered by AST positioning inaccuracy (max: 3.5 ± 2.4%), followed by the RT table (max: 3.6 ± 1.2%) and the RT mask (max: 3.0 ± 0.8% [anterior], 1.6 ± 0.4% [rest]). No correlation between ∆D50[%] and beam depth was found for the sum of opposing beams, except for (45°â€¯+ 315°). CONCLUSION: This study evaluated the integration of auxiliary devices and their dosimetric influence on sCT-based TP. The AST can be easily integrated into the sCT-based TP. Further, we found that the dosimetric impact was within an acceptable range for an MRI-only workflow.


Assuntos
Imageamento por Ressonância Magnética , Planejamento da Radioterapia Assistida por Computador , Humanos , Estudos Retrospectivos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem
13.
Acta Oncol ; 62(11): 1566-1573, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37603112

RESUMO

BACKGROUND: The purpose of this study was to introduce an experimental radiobiological setup used for in vivo irradiation of a mouse leg target in multiple positions along a proton beam path to investigate normal tissue- and tumor models with varying linear energy transfer (LET). We describe the dosimetric characterizations and an acute- and late-effect assay for normal tissue damage. METHODS: The experimental setup consists of a water phantom that allows the right hind leg of three to five mice to be irradiated at the same time. Absolute dosimetry using a thimble (Semiflex) and a plane parallel (Advanced Markus) ionization chamber and Monte Carlo simulations using Geant4 and SHIELD-HIT12A were applied for dosimetric validation of positioning along the spread-out Bragg peak (SOBP) and at the distal edge and dose fall-off. The mice were irradiated in the center of the SOBP delivered by a pencil beam scanning system. The SOBP was 2.8 cm wide, centered at 6.9 cm depth, with planned physical single doses from 22 to 46 Gy. The biological endpoint was acute skin damage and radiation-induced late damage (RILD) assessed in the mouse leg. RESULTS: The dose-response curves illustrate the percentage of mice exhibiting acute skin damage, and at a later point, RILD as a function of physical doses (Gy). Each dose-response curve represents a specific severity score of each assay, demonstrating a higher ED50 (50% responders) as the score increases. Moreover, the results reveal the reversible nature of acute skin damage as a function of time and the irreversible nature of RILD as time progresses. CONCLUSIONS: We want to encourage researchers to report all experimental details of their radiobiological setups, including experimental protocols and model descriptions, to facilitate transparency and reproducibility. Based on this study, more experiments are being performed to explore all possibilities this radiobiological experimental setup permits.


Assuntos
Terapia com Prótons , Prótons , Animais , Camundongos , Reprodutibilidade dos Testes , Terapia com Prótons/métodos , Radiometria/métodos , Modelos Teóricos , Método de Monte Carlo
14.
Anal Bioanal Chem ; 415(26): 6375-6387, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37714973

RESUMO

Monitoring a synthesis reaction in real time could allow not only the detection of the intermediates involved in the synthesis, to better understand its mechanisms, but also the impurities. Spectroscopic methods could be performed but are not so performant when analyzing complex mixtures and could require specific properties for the detection of the molecules of interest, the presence of a chromophore moiety for example. Mass spectrometry (MS) may overcome these limitations and is able to reach the accuracy and sensitivity required to efficiently detect, quantify, identify, and characterize the reagents and species produced during the synthesis. This is why the hyphenation of a microreactor with MS has already allowed synthesis processes to be monitored, but most of the time it targets a specific reaction or compounds and involves solvents compatible with MS. In this study, a universal setup for the hyphenation of a microreactor with MS and based on two valves has been developed. This two-valve setup has proven itself for the analysis of molecules of different nature and hydrophilicity, soluble in a large number of solvents even in non-MS-compatible ones. The developed setup evidenced a good repeatability and a linear response for the detection of the studied compounds. In addition, the dilution step included in the two-valve setup allows the MS monitoring of compounds initially synthesized at different concentrations. Finally, it was successfully used to study an amination reaction allowing the detection of the reaction products in 4 min with good repeatability as RSD values of MS signals were lower than 17%.

15.
Respiration ; 102(5): 386-395, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36921594

RESUMO

BACKGROUND: Advancing the endotracheal tube (ETT) over a flexible bronchoscope (FB) during awake fiber-optic intubation (AFOI) is often impeded. Various maneuvers and tracheal tubes designed to overcome this obstruction may also be unsuccessful or costly. OBJECTIVE: The current study aimed to assess how the novel double configuration ETT affected AFOI success rates on the first attempt. METHODS: A randomized controlled experiment including 40 individuals receiving awake fiber-optic orotracheal intubation was performed in a 1:1 ratio with a single ETT railroaded with its bevel posteriorly (ST) or railroading with a double setup ETT (DT) over a flexible videoscope (FVS) for tracheal intubation. The number of intubation attempts, time spent intubating, and adverse events were examined and compared between the two groups. RESULTS: Twenty patients received a single ETT railroaded with the bevel posteriorly, and 20 patients received railroading with the double setup ETT during AFOI. Intubation on the first attempt was significantly greater in the DT group (90%) than in the ST group (35%). The intubation time was considerably shorter for the DT group (12.8 [7.8-16.9] s) when compared with the ST group (27.9 [16.3-91.0] s). Five patients were intubated by the alternative technique after failure to intubate for several attempts, and 3 cases were found to have a crease in the FVS after intubation in group ST. During topical anesthetic, three individuals in each group experienced transient oxygen desaturation. CONCLUSIONS: Our study discovered that the novel double setup tube could significantly improve the intubation success rate on the first attempt during AFOI for patients with challenging airway when a strategy based on a reduced gap between ETT and FB could not be applied.


Assuntos
Tecnologia de Fibra Óptica , Vigília , Humanos , Intubação Intratraqueal/efeitos adversos , Broncoscopia
16.
J Appl Clin Med Phys ; 24(9): e14038, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37449391

RESUMO

Deep Inspiration Breath Hold (DIBH) is a respiratory-gating technique adopted in radiation therapy to lower cardiac irradiation. When performing DIBH treatments, it is important to have a monitoring system to ensure the patient's breath hold level is stable and reproducible at each fraction. In this retrospective study, we developed a system capable of monitoring DIBH breast treatments by utilizing cine EPID images taken during treatment. Setup error and intrafraction motion were measured for all fractions of 20 left-sided breast patients. All patients were treated with a hybrid static-IMRT technique, with EPID images from the static fields analyzed. Ten patients had open static fields and the other ten patients had static fields partially blocked with the multileaf collimator (MLC). Three image-processing algorithms were evaluated on their ability to accurately measure the chest wall position (CWP) in EPID images. CWP measurements were recorded along a 61-pixel region of interest centered along the midline of the image. The median and standard deviation of the CWP were recorded for each image. The algorithm showing the highest agreement with manual measurements was then used to calculate intrafraction motion and setup error. To measure intrafraction motion, the median CWP of the first EPID frame was compared with that of the subsequent EPID images of the treatment. The maximum difference was recorded as the intrafraction motion. The setup error was calculated as the difference in median CWP between the MV DRR and the first EPID image of the lateral tangential field. The results showed that the most accurate image-processing algorithm can identify the chest wall within 1.2 mm on both EPID and MV DRR images, and measures intrafraction motion and setup errors within 1.4 mm.


Assuntos
Neoplasias da Mama , Radioterapia de Intensidade Modulada , Humanos , Feminino , Radioterapia de Intensidade Modulada/métodos , Estudos Retrospectivos , Suspensão da Respiração , Dosagem Radioterapêutica , Mama , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias da Mama/radioterapia
17.
J Appl Clin Med Phys ; 24(4): e13872, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36537149

RESUMO

PURPOSE: We evaluate an SGRT device (Voxelan HEV-600 M/RMS) installed with Radixact, with the view angle of the Voxelan's camera at 74 degrees. The accuracy of Voxelan with this steep angle was evaluated with phantom experiments and inter-fractional setup errors of patients. METHODS: In the phantom experiments, the difference between the measured values of Voxelan from the truth was evaluated for translations and rotations. The inter-fractional setup error between the setup using skin markers with laser localizer (laser setup: LS) and the setup using Voxelan (surface setup: SS) was compared for head and neck (N = 19), chest (N = 7) and pelvis (N = 9) cases. The inter-fractional setup error was calculated by subtracting from bone matching by megavoltage computed tomography (MVCT) as ground truth. RESULTS: From the phantom experiments, the average difference between the measured values of Voxelan from the truth was within 1 mm and 1 degree. In all cases, inter-fractional setup error based on MVCT was not significantly different between LS and SS by Welch's t-test (P > 0.05). The vector offset of the LS for head and neck, chest, and pelvis were 6.5, 9.6, and 9.6 mm, respectively, and that of the SS were 5.8, 8.6, and 12.6 mm, respectively. Slight improvement was observed for the head and neck, and chest cases, however, pelvis cases were not improved because the umbilical region could not be clearly visualized as a reference. CONCLUSION: The results show that SS in Voxelan with an installation angle of 74 degrees is equal to or better than LS.


Assuntos
Planejamento da Radioterapia Assistida por Computador , Radioterapia Guiada por Imagem , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Cabeça/diagnóstico por imagem , Pescoço , Tomografia Computadorizada de Feixe Cônico , Tórax/diagnóstico por imagem , Radioterapia Guiada por Imagem/métodos
18.
J Appl Clin Med Phys ; 24(3): e13853, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36924428

RESUMO

PURPOSE: The single isocenter for multiple-target (SIMT) technique has become a popular treatment technique for multiple brain metastases. We have implemented a method to obtain a nonuniform margin for SIMT technique. In this study, we further propose a method to determine the isocenter position so that the total expanded margin volume is minimal. MATERIALS AND METHOD: Based on a statistical model, the relationship between nonuniform margin and the distance d (from isocenter to target point), setup uncertainties, and significance level was established. Due to the existence of rotational error, there is a nonlinear relationship between the margin volume and the isocenter position. Using numerical simulation, we study the relationship between optimal isocenter position and translational error, rotational error, and target size. In order to find the optimal isocenter position quickly, adaptive simulated annealing (ASA) algorithm was used. This method was implemented in the Pinnacle3 treatment planning system and compared with isocenter at center-of-geometric (COG), center-of-volume (COV), and center-of-surface (COS). Ten patients with multiple brain metastasis targets treated with the SIMT technique was selected for evaluation. RESULTS: When the size of tumors is equal, the optimal isocenter obtained by ASA and numerical simulation coincides with COG, COV, and COS. When the size of tumors is different, the optimal isocenter is close to the large tumor. The position of COS point is closer to the optimal point than the COV point for nearly all cases. Moreover, in some cases the COS point can be approximately selected as the optimal point. The ASA algorithm can reduce the calculating time from several hours to tens of seconds for three or more tumors. Using multiple brain metastases targets, a series of volume difference and calculating time were obtained for various tumor number, tumor size, and separation distances. Compared with the margin volume with isocenter at COG, the margin volume for optimal point can be reduced by up to 27.7%. CONCLUSION: Optimal treatment isocenter selection of multiple targets with large differences could reduce the total margin volume. ASA algorithm can significantly improve the speed of finding the optimal isocenter. This method can be used for clinical isocenter selection and is useful for the protection of normal tissue nearby.


Assuntos
Neoplasias Encefálicas , Radiocirurgia , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias Encefálicas/cirurgia , Incerteza , Modelos Estatísticos , Simulação por Computador , Radiocirurgia/métodos , Dosagem Radioterapêutica
19.
J Appl Clin Med Phys ; 24(11): e14116, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37538022

RESUMO

Personalized precision irradiation of patients with left-sided breast cancer is possible by examining the setup errors of 3- and 4-mm gated window widths for those treated with deep inspiration breath-hold (DIBH) treatment. An observational study was performed via a retrospective analysis of 250 cone-beam computed tomography (CBCT) images of 60 left-breast cancer patients who underwent whole-breast radiotherapy with the DIBH technique between January 2021 and 2022 at our hospital. Among them, 30 patients had a gated window width of 3 mm, while the remaining 30 had a gated window width of 4 mm; both groups received radiotherapy using DIBH technology. All patients underwent CBCT scans once a week, and the setup errors in the left-right (x-axis), inferior-superior (y-axis), and anterior-posterior (z-axis) directions were recorded. The clinical-to-planning target volume (CTV-PTV) margins of the two gating windows were calculated using established methods. The setup error in the Y direction was 1.69 ± 1.33 mm for the 3-mm - wide gated window and 2.42 ± 3.02 mm for the 4-mm - wide gated window. The two groups had statistically significant differences in the overall mean setup error (Dif 0.7, 95% CI 0.15-1.31, t = 2.48, p= 0.014). The Z-direction setup error was 2.32 ± 2.12 mm for the 3-mm - wide gated window and 3.15 ± 3.34 mm for the 4-mm - wide gated window. The overall mean setup error was statistically significant between the two groups (Dif 0.8, 95% CI 0.13-1.53, t= 2.34, p = 0.020). There was no significant difference in the X-direction setup error (p > 0.05). Therefore, the CTV-PTV margin values for a 3-mm gated window width in the X, Y, and Z directions are 5.51, 5.15, and 7.28 mm, respectively; those for a 4-mm gated window width in the X, Y, and Z directions are 5.52, 8.16, and 10.21 mm, respectively. The setup errors of the 3-mm - wide gating window are smaller than those of the 4-mm - wide gating window in the three dimensions. Therefore, when the patient's respiratory gating window width is reduced, the margin values of CTV-PTV can be reduced to increase the distance between the PTV and the organs at risk (OARs), which ensures adequate space for the dose to decrease, resulting in lower dose exposure to the OARs (heart, lungs, etc.), thus sparing the OARs from further damage. However, some patients with poor pulmonary function or unstable breathing amplitudes must be treated with a slightly larger gating window. Therefore, this study lays a theoretical basis for personalized precision radiotherapy, which can save time and reduce manpower in the delivery of clinical treatment to a certain extent. Another potential benefit of this work is to bring awareness to the potential implications of a slightly larger gating window during treatment without considering the resulting dosimetric impact.


Assuntos
Neoplasias da Mama , Neoplasias Unilaterais da Mama , Humanos , Feminino , Suspensão da Respiração , Estudos Retrospectivos , Neoplasias da Mama/radioterapia , Tomografia Computadorizada por Raios X/métodos , Respiração , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Neoplasias Unilaterais da Mama/radioterapia
20.
J Appl Clin Med Phys ; 24(12): e14117, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37535396

RESUMO

To compare the setup accuracy of optical surface image (OSI) versus orthogonal x-ray images (2DkV) using cone beam computed tomography (CBCT) as ground truth for radiotherapy of left breast cancer in deep-inspiration breath-hold (DIBH). Ten left breast DIBH patients treated with volumetric modulated arc therapy (VMAT) were studied retrospectively. OSI, 2DkV, and CBCT were acquired weekly at treatment setup. OSI, 2DkV, and CBCT were registered to planning CT or planning DRR based on a breast surface region of interest (ROI), bony anatomy (chestwall and sternum), and both bony anatomy and breast surface, respectively. These registrations provided couch shifts for each imaging system. The setup errors, or the difference in couch shifts between OSI and CBCT were compared to those between 2DkV and CBCT. A second OSI was acquired during last beam delivery to evaluate intrafraction motion. The median absolute setup errors were (0.21, 0.27, 0.23 cm, 0.6°, 1.3°, 1.0°) for OSI, and (0.26, 0.24, 0.18 cm, 0.9°, 1.0°, 0.6°) for 2DkV in vertical, longitudinal and lateral translations, and in rotation, roll and pitch, respectively. None of the setup errors was significantly different between OSI and 2DkV. For both systems, the systematic and random setup errors were ≤0.6 cm and ≤1.5° in all directions. Nevertheless, larger setup errors were observed in some sessions in both systems. There was no correlation between OSI and CBCT whereas there was modest correlation between 2DkV and CBCT. The intrafraction motion in DIBH detected by OSI was small with median absolute translations <0.2 cm, and rotations ≤0.4°. Though OSI showed comparable and small setup errors as 2DkV, it showed no correlation with CBCT. We concluded that to achieve accurate setup for both bony anatomy and breast surface, daily 2DkV can't be omitted following OSI for left breast patients treated with DIBH VMAT.


Assuntos
Neoplasias da Mama , Radioterapia de Intensidade Modulada , Humanos , Feminino , Estudos Retrospectivos , Raios X , Tomografia Computadorizada de Feixe Cônico/métodos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Suspensão da Respiração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA