Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Curr Cardiol Rep ; 22(12): 175, 2020 10 10.
Artigo em Inglês | MEDLINE | ID: mdl-33040213

RESUMO

PURPOSE OF REVIEW: We review the prevalence; natural history; impact of subclinical clinical thrombosis on valve hemodynamics, clinical outcomes, and valve durability; and the role of anticoagulation after transcatheter aortic valve replacement (TAVR). RECENT FINDINGS: Subclinical leaflet thrombosis is a dynamic finding present in both transcatheter and surgical bioprosthetic aortic valves. This finding is less prevalent in patients on anticoagulation and resolves following initiation of anticoagulation. Routine anticoagulation after TAVR in high-surgical-risk patients was associated with increased mortality and thromboembolic complications. In the absence of a clinical indication for anticoagulation, there is no reason to initiate anticoagulation after TAVR for the prevention of subclinical leaflet thrombosis. In patients with an established indication for anticoagulation, for instance, atrial fibrillation, clinical or symptomatic valve thrombosis, or a clinical event related to valve thrombosis, anticoagulation should be initiated or continued after TAVR to treat the clinical indication.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Anticoagulantes/uso terapêutico , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
2.
Int J Cardiol ; 398: 131597, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37979790

RESUMO

BACKGROUND: Subclinical leaflet thrombosis is diagnosed using multidetector computed tomography (MDCT) and is characterised by a meniscal-shaped hypoattenuated lesion of one or more leaflets. Transcatheter aortic self-expandable valves are commonly manufactured with pliable pericardium over a nitinol frame that forms leaflet and extra-leaflet components such as the valve skirt. Little is known about extra-leaflet hypoattenuated lesion localisation, including that at the anatomical sinus level. Thus, the main aim of this study was to describe leaflet and extra-leaflet (anatomic sinus and subvalvular level) hypoattenuated lesions following transcatheter aortic valve replacement with a self-expandable prosthesis. As a secondary aim, we sought to investigate predictors of hypoattenuated lesions. METHODS: Fifty patients underwent MDCT at the follow-up. RESULTS: At a follow-up of 12 months, hypoattenuated leaflet lesions with mild to severe restricted movement were detected in eight individuals (16%), anatomic sinus lesions were identified in nine patients (18%), with higher prevalence in the non-coronary sinus (16%), and subvalvular lesions with variable extension toward the valve inflow were diagnosed in eight patients (16%). In 4 patients (8%) the anatomic sinus thrombus was 'in overlap' with leaflet thrombus; in 3 patients (6%) was in continuity with subvalvular frame thrombus. Bicuspid valve was the only independent predictor associated with hypoattenuated lesions (adj OR 8.25 (95% CI: 1.38, 49.21), p = 0.02)). CONCLUSIONS: This study demonstrated that hypoattenuated lesions could be identified not only at the leaflet but also at the subvalvular and anatomic sinus levels. The clinical relevance of such lesions remains unclear.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Trombose , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Trombose/diagnóstico por imagem , Trombose/etiologia , Trombose/epidemiologia , Resultado do Tratamento
3.
Int J Cardiol ; 396: 131551, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37866786

RESUMO

BACKGROUND: Following transcatheter aortic valve replacement (TAVI), the newly formed 'anatomic sinus'. may contribute to the formation of subclinical leaflet thrombosis (SLT).The evaluation of root geometry after TAVI is generally performed using multi-detector computed tomography (MDCT), and the role of transthoracic echocardiography (2D TTE) requires further validation. Thus, we aimed to test the reproducibility of 2D TTE assessment of the anatomic sinus with MDCT as a reference and its association with SLT. METHODS: 2D TTE was performed in 90 patients, and the echocardiograms were analyzed offline. Both sinus of Valsalva (SOV) and prosthesis diameters were assessed in the long- and short-axis parasternal views (PLAX/PSAX), and the anatomic sinus area was calculated. Inter- and intra-observer reproducibility were assessed using the interclass correlation coefficient (ICC). MDCT was performed in 50 individuals to evaluate concordance with 2D TTE and to detect SLT. RESULTS: There was excellent correlation regarding the diameter of the SOV and the prosthesis in PLAX (ICC: 0.93 (95% CI: 0.76,0.97); ICC: 0.80 (95% CI: 0.63,0.96)) and PSAX view (ICC: 0.90 (95% CI: 0.68,0.97); ICC: 0.88 (95% CI: 0.63,0.96)). Bland-Altman analysis of 2D TTE and MDCT anatomic sinus areas indicated a high level of agreement. SLT was detected in 8 individuals (16%); 3 patients had severe SLT at the level of 1 cusp. CONCLUSIONS: 2D TTE might play a role in the evaluation of the anatomic sinus after TAVI. The importance of this space and its effects on the SLT remain uncertain.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Reprodutibilidade dos Testes
4.
J Am Coll Cardiol ; 84(9): 848-861, 2024 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-39168571

RESUMO

Transcatheter aortic valve (TAV) thrombosis may manifest as subclinical leaflet thrombosis (SLT) and clinical valve thrombosis. SLT is relatively common (10%-20%) after transcatheter aortic valve replacement, but clinical implications are uncertain. Clinical valve thrombosis is rare (1.2%) and associated with bioprosthetic valve failure, neurologic or thromboembolic events, heart failure, and death. Treatment for TAV thrombosis has been understudied. In principle, anticoagulation may prevent TAV thrombosis. Non-vitamin K oral anticoagulants, as compared to antiplatelet therapy, are associated with reduced incidence of SLT, although at the cost of higher bleeding and all-cause mortality risk. We present an overview of existing literature for management of TAV thrombosis and propose a rational treatment algorithm. Vitamin K antagonists or non-vitamin K oral anticoagulants are the cornerstone of antithrombotic treatment. In therapy-resistant or clinically unstable patients, ultraslow, low-dose infusion of thrombolytics seems effective and safe and may be preferred over redo-transcatheter aortic valve replacement or explant surgery.


Assuntos
Trombose , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Trombose/prevenção & controle , Trombose/etiologia , Anticoagulantes/uso terapêutico , Anticoagulantes/administração & dosagem , Fibrinolíticos/uso terapêutico , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos
5.
Int J Cardiol ; 395: 131431, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-37832606

RESUMO

BACKGROUND: Recent randomized studies have broadened the indication of transcatheter aortic valve replacement (TAVR) to also include low-surgical-risk patients. However, the data on self-expanding (SE) and balloon-expandable (BE) valves in low-risk patients remain sparse. METHODS: The current study is a post hoc analysis of combined data from both LRT 1.0 and 2.0 trials comparing BE and SE transcatheter heart valves. RESULTS: A total of 294 patients received a BE valve, and 102 patients received an SE valve. The 30-day clinical outcomes were similar across both groups except for stroke (4.9% vs. 0.7%, p = 0.014) and permanent pacemaker implantation (17.8% vs. 5.8%, p < 0.001), which were higher in the SE cohort than the BE cohort. No difference was observed in terms of paravalvular leak (≥moderate) between the groups (0% vs. 1.5%, p = 0.577). SE patients had higher aortic valve area (1.92 ± 0.43 mm2 vs. 1.69 ± 0.45 mm2, p < 0.001) and lower mean gradient (8.93 ± 3.53 mmHg vs. 13.41 ± 4.73 mmHg, p < 0.001) than BE patients. In addition, the rate of subclinical leaflet thrombosis was significantly lower in SE patients (5.6% vs. 13.8%, p = 0.038). CONCLUSION: In this non-randomized study assessing SE and BE valves in low-risk TAVR patients, SE valves are associated with better hemodynamics and lesser leaflet thrombosis, with increased rates of stroke and permanent pacemaker implantation at 30 days; however, this could be due to certain patient-dependent factors not fully evaluated in this study. The long-term implications of these outcomes on structural valve durability remain to be further investigated. CLINICAL TRIAL REGISTRY: LRT 1.0: NCT02628899 LRT 2.0: NCT03557242.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Trombose , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Acidente Vascular Cerebral/etiologia , Trombose/etiologia , Resultado do Tratamento , Desenho de Prótese , Fatores de Risco
6.
Circ Rep ; 5(12): 450-458, 2023 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-38073872

RESUMO

Background: Subclinical leaflet thrombosis occasionally occurs after transcatheter aortic valve implantation (TAVI), but its exact etiology and relationship with thrombogenicity remain unknown. Methods and Results: This study enrolled 35 patients who underwent TAVI. Thrombogenicity was evaluated using a total thrombus-formation analysis system (T-TAS) to compute the thrombus-formation area under the curve (PL18-AUC10 and AR10-AUC30). Periprocedural thrombogenic parameters including T-TAS were investigated at pre-TAVI, 2 days, 7 days, and 3 months post-TAVI. Hypoattenuated leaflet thickening (HALT) and maximum leaflet thickness (MLT) were evaluated using contrast-enhanced computed tomography 7 days and 3 months post-TAVI. The associations between thrombogenicity and HALT or MLT were assessed. T-TAS parameters consistently decreased at 2 and 7 days post-TAVI, followed by improvement at 3 months. HALT was detected in 20% and 17% of patients at 7 days and 3 months, respectively, post-TAVI. The median MLT value was 1.60 mm at 7 days and 3 months post-TAVI. A significant positive correlation was observed between the decrease in the AR10-AUC30 and MLT at 7 days post-TAVI. Univariate linear regression analysis revealed a decrease in the AR10-AUC30 and an increase in the D-dimer level as a significant predictor of MLT deterioration. Conclusions: The findings suggested that a transient decrease in thrombogenicity following TAVI predicts leaflet thrombosis, implying that monitoring thrombogenicity may be useful for predicting progression of leaflet thrombosis.

7.
Am J Cardiol ; 207: 93-99, 2023 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-37734306

RESUMO

The incidence of non-uniform expansion in the context of the self-expandable transcatheter heart valve (THV) is little investigated, along with stent-frame decoupling, which is a form of stent adaptation, in which the lower part of the THV stent conforms to both the ellipticity of the left ventricle outflow tract and the native annulus while maintaining the higher part of the valve more circular. We analyzed post-implant multi-detector computed tomography scans in 50 patients. Prosthesis non-uniform expansion was assessed by computing the prosthesis eccentricity on 6 prespecified levels: (1) frame inflow, (2) native annulus, (3) leaflet inflow, (4) prosthesis waist, (5) leaflet outflow, and (6) frame outflow. Stent-frame decoupling was assessed by comparing the mean eccentricity on 6 different prosthesis levels. Implantation depth, leaflet expansion and alignment, and residual anatomic sinus area ratios were also calculated. Subclinical leaflet thrombosis was defined as hypoattenuated lesion of a meniscal shape. At a 12-month follow-up, non-uniform expansion was consistently detected at each valvular level. Highest eccentricity was measured at the native annulus level (eccentricity: 0.54 ±  0.12), while the lowest index at the frame outflow level (0.23 ± 0.11). Similar results were observed in the subgroup analyses of sizes 23, 26, 29, and 34. Eccentricity significantly decreased from the annulus level to the prosthesis frame outflow (p <0.001). Notably, the incidence of mild-to-severe subclinical leaflet thrombosis was relevant (16%). In conclusion, prosthesis non-uniform expansion and stent frame decoupling frequently occur after self-expandable THV replacement. The clinical and hemodynamic implications remain uncertain.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Trombose , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/métodos , Stents , Resultado do Tratamento
8.
Int J Cardiol ; 371: 305-311, 2023 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-36272571

RESUMO

BACKGROUND: Subclinical leaflet thrombosis (SLT) is characterized on computed tomography (CT) imaging as hypoattenuated leaflet thickening (HALT), reduced leaflet motion (RELM), and hypoattenuation affecting motion (HAM). How antithrombotic regimen type impacts SLT remains poorly understood. We evaluated how antithrombotic regimen type impacts SLT in low-risk subjects following transcatheter aortic valve implantation (TAVI). METHODS: This substudy is a post hoc analysis of the LRT 1.0 and 2.0 trials to assess SLT in subjects who underwent CT or transoesophageal echocardiogram (TOE) imaging at 30 days, stratified by antithrombotic regimen received (single antiplatelet therapy [SAPT], dual antiplatelet therapy [DAPT], or oral anticoagulation). We also utilized univariable logistic regression modelling to identify echocardiographic predictors of HALT. RESULTS: Rates of HALT, RELM, and HAM were all significantly lower with oral anticoagulation compared to SAPT or DAPT at 30 days (HALT: 2.6% vs 14.3% vs 17.2%, respectively, with p < 0.001; RELM: 1.8% vs 9.6% vs 13.1%, respectively, with p = 0.004; and HAM: 0.9% vs 8.5% vs 9.8%, respectively, with p = 0.011). Additionally, short-term oral anticoagulation was not associated with higher bleeding rates compared to SAPT or DAPT (0.8% vs. 1.8% vs. 3.6%, p = 0.291). The presence of HALT did not significantly impact echocardiographic haemodynamic parameters at 30 days. CONCLUSION: This is the largest study to date that evaluated the impact of different antithrombotic regimens on SLT in low-risk TAVI patients. Oral anticoagulation was associated with significantly lower rates of SLT at 30 days compared to DAPT or SAPT, and there was no apparent benefit of DAPT over SAPT.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Trombose , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Fibrinolíticos/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Trombose/diagnóstico por imagem , Trombose/tratamento farmacológico , Trombose/etiologia , Resultado do Tratamento , Inibidores da Agregação Plaquetária/efeitos adversos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/tratamento farmacológico , Estenose da Valva Aórtica/cirurgia
9.
J Cardiovasc Transl Res ; 16(3): 674-681, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36261703

RESUMO

Subclinical leaflet thrombosis has been increasingly observed in patients undergoing transcatheter aortic valve replacement. Intra-annular transcatheter aortic valves (TAVs) have a larger neo-sinus volume than supra-annular devices and are potentially at a higher risk of hypoattenuated leaflet thickening (HALT). However, clinical data from randomized clinical trials have shown that approximately one-third of patients undergoing TAVR with intra- or supra-annular devices develop HALT in 1 year. The findings point to the potential role of leaflet design in developing HALT. The study aimed to systematically investigate leaflet kinematics of a supra-annular TAV, Medtronic CoreValve, and determine regions of blood stasis. Fluid-solid interaction simulations demonstrated the limited movement of CoreValve leaflets in the lower belly region that created regions of blood stasis on the surface of the leaflets. The findings provide insights into potential improvements in leaflet design in the next generation of TAVs to reduce the risk of HALT and leaflet immobility.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Trombose , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Trombose/diagnóstico por imagem , Trombose/etiologia , Trombose/cirurgia , Estenose da Valva Aórtica/cirurgia , Desenho de Prótese , Resultado do Tratamento
10.
Artigo em Inglês | MEDLINE | ID: mdl-36271854

RESUMO

OBJECTIVES: Subclinical leaflet thrombosis is a silent phenomenon commonly observed following transcatheter aortic valve implantation (TAVI). Leaflet thrombosis is associated with ischaemic complications and structural valve deterioration. Prior studies have shown that blood stasis in neo-sinus contributes to the initiation and growth of subclinical leaflet thrombosis. This study aimed to quantify temporal and spatial characteristics of the flow field from a fundamental perspective. METHODS: in vitro experimental analysis and fluid-solid interaction simulations were employed to characterize the flow field of a transcatheter aortic valve (TAV) with an intra-annular design in a pulse duplicator. Blood residence time (BRT) and flow-induced viscous shear stress were measured in the neo-sinus and on the surface of TAV leaflets. RESULTS: Temporal and spatial velocity variations were observed in neo-sinus, indicating that the flow is time-dependent and fully three-dimensional. The degree of blood stasis in the neo-sinus (bulk fluid) and on the surface of the TAV leaflets highly depends on the local flow characteristics. Regional flow variation in the neo-sinus resulted in substantial variations in BRT magnitude in the neo-sinus and on the surface of the TAV leaflet. Areas with a high degree of blood stasis were observed near the fixed boundary edge of the leaflets. CONCLUSIONS: The study indicated that leaflet motion is a primary driver of flow in neo-sinus. Considering the substantial variations in BRT magnitude in the neo-sinus (bulk fluid), blood stasis should be quantified locally on the surface of foreign (valve) materials to avoid errors in forecasting the risk of subclinical leaflet thrombosis in patients undergoing TAVI.

11.
Int J Cardiovasc Imaging ; 38(3): 695-705, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34655348

RESUMO

Hypo-attenuated leaflet thickening (HALT) of transcatheter aortic valves is detected on multidetector computed tomography (MDCT) and reflects leaflet thrombosis. Whether HALT affects left ventricular (LV) reverse remodeling, a favorable effect of LV afterload reduction after transcatheter aortic valve implantation (TAVI) is unknown. The aim of this study was to examine the association of HALT after TAVI with LV reverse remodeling. In this multicenter case-control study, patients with HALT on MDCT were identified, and patients without HALT were propensity matched for valve type and size, LV ejection fraction (LVEF), sex, age and time of scan. LV dimensions and function were assessed by transthoracic echocardiography before and 12 months after TAVI. Clinical outcomes (stroke or transient ischemic attack, heart failure hospitalization, new-onset atrial fibrillation, all-cause mortality) were recorded. 106 patients (age 81 ± 7 years, 55% male) with MDCT performed 37 days [IQR 32-52] after TAVI were analyzed (53 patients with HALT and 53 matched controls). Before TAVI, all echocardiographic parameters were similar between the groups. At 12 months follow-up, patients with and without HALT showed a significant reduction in LV end-diastolic volume, LV end-systolic volume and LV mass index (from 125 ± 37 to 105 ± 46 g/m2, p = 0.001 and from 127 ± 35 to 101 ± 27 g/m2, p < 0.001, respectively, p for interaction = 0.48). Moreover, LVEF improved significantly in both groups. In addition, clinical outcomes were not statistically different. Improvement in LVEF and LV reverse remodeling at 12 months after TAVI were not limited by HALT.


Assuntos
Estenose da Valva Aórtica , Trombose , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estudos de Casos e Controles , Feminino , Seguimentos , Humanos , Masculino , Valor Preditivo dos Testes , Trombose/complicações , Trombose/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Função Ventricular Esquerda , Remodelação Ventricular
12.
JACC Cardiovasc Interv ; 14(24): 2643-2656, 2021 12 27.
Artigo em Inglês | MEDLINE | ID: mdl-34949391

RESUMO

This meta-analysis and systematic review was performed to evaluate the clinical relevance of subclinical leaflet thrombosis (SLT) following transcatheter aortic valve replacement. PubMed, Web of Science, and CENTRAL were searched for eligible randomized and nonrandomized studies until November 2020. Risk ratios (RRs) or odds ratios and 95% CIs were calculated, using a random-effects model. Overall, 25 studies were eligible for the analysis and comprised a total of 11,098 patients. The median incidence of SLT was 6% at a median follow-up of 30 days. Use of intra-annular valves was associated with 2-fold greater risk for the development of SLT compared with use of supra-annular valves. There was no difference in the risk for SLT (RR: 0.97; 95% CI: 0.72-1.29; P = 0.83) between single-antiplatelet therapy (SAPT) and dual-antiplatelet therapy (DAPT), whereas oral anticoagulation (OAC) was associated with a 58% relative risk reduction for SLT (RR: 0.42; 95% CI: 0.29-0.61; P < 0.00001) compared with SAPT and DAPT. In patients with diagnosed leaflet thrombosis at follow-up, the risk for stroke or transient ischemic attack was increased by 2.6-fold (RR: 2.56; 95% CI: 1.60-4.09; P < 0.00001) compared with patients without leaflet thrombosis. In patients diagnosed with SLT, the odds of SLT resolution increased by 99% after switch from antiplatelet agents to OAC (odds ratio: 0.01; 95% CI: 0.00-0.06; P < 0.00001). To summarize, indication-based use of OAC after transcatheter aortic valve replacement is associated with a lower risk for SLT compared with SAPT and DAPT. Switching to OAC seems to be effective for SLT resolution. As SLT increased the odds of stroke or transient ischemic attack in the included population, further studies are needed to investigate whether screening tests for SLT and appropriate antithrombotic therapy improve long-term valve functionality and clinical prognosis.


Assuntos
Estenose da Valva Aórtica , Trombose , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Terapia Antiplaquetária Dupla , Humanos , Inibidores da Agregação Plaquetária/uso terapêutico , Fatores de Risco , Trombose/diagnóstico por imagem , Trombose/epidemiologia , Trombose/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
13.
Front Cardiovasc Med ; 8: 746774, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35224023

RESUMO

BACKGROUND: Systemic inflammatory response syndrome (SIRS) is a systemic insult that has been described with many interventional cardiac procedures. The outcomes of patients undergoing transcatheter aortic valve implantation (TAVI) are thought to be influenced by this syndrome not only on short-term, but also on long-term. OBJECTIVE: We assessed the association of SIRS to different clinical, echocardiographic, and computed tomographic (CT) outcomes after TAVI. METHODS: Two hundred and twenty-four consecutive patients undergoing TAVI were enrolled in this study. They were assessed for the occurrence of SIRS within the first 48 h after TAVI. Patients were followed-up for short- and long-term clinical outcomes. Serial echocardiographic follow-ups were conducted at 1-week, 6-months, and 1-year. CT follow-up at 1 year was recorded. RESULTS: Eighty patients (36%) developed SIRS. Among different parameters, only pre-TAVI total leucocytic count (TLC), pre-TAVI heart rate, and post-TAVI systolic blood pressure independently predicted the occurrence of SIRS. The incidence of HALT was not significantly different between both groups, albeit higher among SIRS patients (p = 0.1) at 1-year CT follow-up. Both groups had similar patterns of LV recovery on serial echocardiography. Long-term follow-up showed that all-cause death, cardiac death, and re-admission for heart failure (HF) or acute coronary syndrome (ACS) were significantly more frequent among SIRS patients. Early safety and clinical efficacy outcomes were more frequently encountered in the SIRS group, while device-related events and time-related valve safety were comparable. CONCLUSION: Although SIRS implies an early acute inflammatory status post-TAVI, yet its clinical sequelae seem to extend to long-term clinical outcomes.

14.
Front Cardiovasc Med ; 8: 790069, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35004901

RESUMO

Background: Subclinical leaflet thrombosis (SLT) is an important sequela that compromises the durability of the bioprosthetic valve. Objectives: To better determine the effect of SLT in bicuspid aortic valve (BAV), we performed a retrospective assessment of CT-defined SLT in BAV and tricuspid aortic valve (TAV) stenotic patients. Methods: We consecutively collected patients undergoing the TAVR between August 2015 and March 2020 in our center. A total of 170 BAV and 201 TAV cases were enrolled. Multidetector computed tomography was performed within 30 days and at 1-year. Results: Twenty cases in the BAV group and 19 cases in the TAV group had hypoattenuated leaflet thickening (HALT) in 30 days (12.5 vs. 9.9%, p = 0.449), and 52 cases in BAV and 61 cases in TAV had the HALT (34.9 vs. 36.7%, p = 0.733) at 1-year follow-up. The mean aortic gradient (MAG) and effective orifice areas (EOA) values were comparable between the two groups at 30 days (HALT vs. no HALT; 10.8 ± 4.8 vs. 11.3 ± 6.0, p = 0.638; 1.6 ± 0.4 vs. 1.6 ± 0.3, p = 0.724), and still, no difference was observed in the MAG at 1-year (11.5 ± 5.6 vs. 10.6 ± 5.1, p = 0.164). However, the EOA at 1-year was statistically different between the two groups (1.5 ± 0.3 vs. 1.6 ± 0.4, p = 0.004). The multivariate logistic regression analysis demonstrated the anticoagulation and age as independent predictors both in the BAV and TAV groups at 1-year. There was no difference in clinical events between the HALT and no HALT group in relevant to BAV or TAV at 1-year follow-up. Conclusions: The presence of subclinical leaflet thrombosis defined by the CT was comparable between the BAV and TAV in the first year after the TAVR procedure. Age and anticoagulation were the independent predictors of the subclinical leaflet thrombosis at 1 year after the TAVR. There was no difference in relevant clinical events between the BAV and TAV groups at 1-year follow-up.

15.
Cardiol Res ; 11(5): 269-273, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32849960

RESUMO

Transcatheter aortic valve implantation (TAVI) has been considered an important therapy for the treatment of symptomatic severe aortic stenosis. Although the devices and the techniques have been improved some complications may occur and several issues still need to be addressed. The issue of subclinical leaflet thrombosis (SLT) has been recognized as a complication after TAVI, and its incidence ranges from 0% to 40%. Nowadays, computed tomography is considered as the standard method for diagnosis of SLT. The concept of hypoattenuated leaflet thickening (HALT), reduced leaflet motion (RELM), and hypoattenuation affecting motion (HAM) have been used in this topic. Most patients who had SLT were taking single or dual antiplatelet therapy. In addition, these medications were not effective in resolving this complication after TAVI. However, there is a suggestion that oral anticoagulants have a protective and therapeutic effect. With the increasing use of TAVI, it is necessary to have better knowledge about several aspects of this complication, because it may have impact on prognosis. Therefore, some aspects of SLT diagnosis, management, and prognosis are not yet fully understood.

16.
Eur Heart J Cardiovasc Imaging ; 21(10): 1144-1151, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-31665257

RESUMO

AIMS: Cardiac CT is increasingly applied for planning and follow-up of transcatheter aortic valve implantation (TAVI). However, there are no data available on reverse remodelling after TAVI assessed by CT. Therefore, we aimed to evaluate the predictors and the prognostic value of left ventricular (LV) reverse remodelling following TAVI using CT angiography. METHODS AND RESULTS: We investigated 117 patients with severe, symptomatic aortic stenosis (AS) who underwent CT scanning before and after TAVI procedure with a mean follow-up time of 2.6 years after TAVI. We found a significant reduction in LV mass (LVM) and LVM indexed to body surface area comparing pre- vs. post-TAVI images: 180.5 ± 53.0 vs. 137.1 ± 44.8 g and 99.7 ± 25.4 vs. 75.4 ± 19.9 g/m2, respectively, both P < 0.001. Subclinical leaflet thrombosis (SLT) was detected in 25.6% (30/117) patients. More than 20% reduction in LVM was defined as reverse remodelling and was detected in 62.4% (73/117) of the patients. SLT, change in mean pressure gradient on echocardiography and prior myocardial infarction was independently associated with LV reverse remodelling after adjusting for age, gender, and traditional risk factors (hypertension, body mass index, diabetes mellitus, and hyperlipidaemia): OR = 0.27, P = 0.022 for SLT and OR = 0.22, P = 0.006 for prior myocardial infarction, OR = 1.51, P = 0.004 for 10 mmHg change in mean pressure gradient. Reverse remodelling was independently associated with favourable outcomes (HR = 0.23; P = 0.019). CONCLUSION: TAVI resulted in a significant LVM regression on CT. The presence of SLT showed an inverse association with LV reverse remodelling and thus it may hinder the beneficial LV structural changes. Reverse remodelling was associated with improved long-term prognosis.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Trombose , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Ecocardiografia , Humanos , Trombose/diagnóstico por imagem , Trombose/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Remodelação Ventricular
17.
J Am Coll Cardiol ; 75(24): 3003-3015, 2020 06 23.
Artigo em Inglês | MEDLINE | ID: mdl-32553252

RESUMO

BACKGROUND: Subclinical leaflet thrombosis, characterized by hypoattenuated leaflet thickening (HALT) and reduced leaflet motion observed on 4-dimensional computed tomography (CT), may represent a form of bioprosthetic valve dysfunction. OBJECTIVES: The U.S. Food and Drug Administration mandated CT studies to understand the natural history of this finding, differences between transcatheter and surgical valves, and its association with valve hemodynamics and clinical outcomes. METHODS: The PARTNER 3 (The Safety and Effectiveness of the SAPIEN 3 Transcatheter Heart Valve in Low-Risk Patients With Aortic Stenosis) CT substudy randomized 435 patients with low-surgical-risk aortic stenosis to undergo transcatheter aortic valve replacement (n = 221) or surgery (n = 214). Serial 4-dimensional CTs were performed at 30 days and 1 year and were analyzed independently by a core laboratory. RESULTS: The incidence of HALT increased from 10% at 30 days to 24% at 1 year. Spontaneous resolution of 30-day HALT occurred in 54% of patients at 1 year, whereas new HALT appeared in 21% of patients at 1 year. HALT was more frequent in transcatheter versus surgical valves at 30 days (13% vs. 5%; p = 0.03), but not at 1 year (28% vs. 20%; p = 0.19). The presence of HALT did not significantly affect aortic valve mean gradients at 30 days or 1 year. Patients with HALT at both 30 days and 1 year, compared with those with no HALT at 30 days and 1 year, had significantly increased aortic valve gradients at 1 year (17.8 ± 2.2 mm Hg vs. 12.7. ± 0.3 mm Hg; p = 0.04). CONCLUSIONS: Subclinical leaflet thrombosis was more frequent in transcatheter compared with surgical valves at 30 days, but not at 1 year. The impact of HALT on thromboembolic complications and structural valve degeneration needs further assessment.


Assuntos
Estenose da Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Trombose/epidemiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Canadá/epidemiologia , Feminino , Tomografia Computadorizada Quadridimensional , Humanos , Masculino , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Trombose/diagnóstico por imagem , Trombose/etiologia , Substituição da Valva Aórtica Transcateter/mortalidade , Estados Unidos/epidemiologia
18.
JACC Cardiovasc Interv ; 12(10): 901-907, 2019 05 27.
Artigo em Inglês | MEDLINE | ID: mdl-30860059

RESUMO

OBJECTIVES: This study sought to evaluate clinical outcomes and transcatheter heart valve hemodynamics at 1 year after transcatheter aortic valve replacement (TAVR) in low-risk patients. BACKGROUND: Early results from the LRT (Low Risk TAVR) trial demonstrated that TAVR is safe in patients with symptomatic severe aortic stenosis who are at low risk for surgical valve replacement. METHODS: The LRT trial was an investigator-initiated, prospective, multicenter study and was the first Food and Drug Administration-approved Investigational Device Exemption trial to evaluate feasibility of TAVR in low-risk patients. The primary endpoint was all-cause mortality at 30 days. Secondary endpoints included clinical outcomes and valve hemodynamics at 1 year. RESULTS: The LRT trial enrolled 200 low-risk patients with symptomatic severe AS to undergo TAVR at 11 centers. Mean age was 73.6 years and 61.5% were men. At 30 days, there was zero mortality, zero disabling stroke, and low permanent pacemaker implantation rate (5.0%). At 1-year follow-up, mortality was 3.0%, stroke rate was 2.1%, and permanent pacemaker implantation rate was 7.3%. Two (1.0%) subjects underwent surgical reintervention for endocarditis. Of the 14% of TAVR subjects who had evidence of hypoattenuated leaflet thickening at 30 days, there was no impact on valve hemodynamics at 1 year, but the stroke rate was numerically higher (3.8% vs. 1.9%; p = 0.53). CONCLUSIONS: TAVR in low-risk patients with symptomatic severe aortic stenosis appears to be safe at 1 year. Hypoattenuated leaflet thickening, observed in a minority of TAVR patients at 30 days, did not have an impact on valve hemodynamics in the longer term.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Estudos de Viabilidade , Feminino , Hemodinâmica , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Recuperação de Função Fisiológica , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Índices de Gravidade do Trauma , Resultado do Tratamento , Estados Unidos
19.
Front Cardiovasc Med ; 6: 44, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31058168

RESUMO

Transcatheter aortic valve replacement (TAVR) has become an established therapeutic option for patients with symptomatic, severe aortic valve stenosis at increased surgical risk. Antithrombotic therapy after TAVR aims to prevent transcatheter heart valve (THV) thrombosis, in which two different entities have to be recognized: clinical valve thrombosis and subclinical leaflet thrombosis. In clinical valve thrombosis, obstructive thrombus formation leads to an increased transvalvular gradient, often provoking heart failure symptoms. Subclinical leaflet thrombosis is most often an incidental finding, characterized by a thin layer of thrombus covering the aortic side of one or more leaflets; it is also referred to as Hypo-Attenuating Leaflet Thickening (HALT) as described on multi-detector computed tomography (MDCT) imaging. This phenomenon may also affect leaflet motion and is then classified as Hypo-Attenuation affecting Motion (HAM). Even in case of HAM, the transvalvular pressure gradient remains within normal range and does not provoke heart failure symptoms. Whereas, clinical valve thrombosis requires treatment, the clinical impact and need for intervention in subclinical leaflet thrombosis is still uncertain. Oral anticoagulant therapy protects against and resolves both clinical valve thrombosis and subclinical leaflet thrombosis; however, large-scale randomized clinical trials studying different antithrombotic strategies after TAVR are still under way. This review article summarizes the currently available data within the field of transcatheter aortic valve/leaflet thrombosis and discusses the need for a patient tailored antithrombotic approach.

20.
J Clin Med ; 8(4)2019 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-31013785

RESUMO

The impact of antithrombotic regimen and platelet inhibition extent on subclinical leaflet thrombosis (SLT) detected by cardiac multidetector computed tomography (MDCT) after transcatheter aortic valve replacement (TAVR) is not well established. Hypoattenuation affecting motion (HAM) has been proposed as a surrogate marker of SLT, and is characterized by hypoattenuated leaflet thickening (HALT) and concomitant reduction in leaflet motion (RELM). We sought to investigate (i) the prevalence of HAM and HALT after TAVR detected by MDCT, (ii) the predictors of SLT, (iii) the impact of oral anticoagulant (OAC) and platelet inhibition extent assessed by platelet reactivity index vasodilator stimulated phosphoprotein (PRI-VASP) and closure time adenosine diphosphate (CT-ADP) on SLT. Of 187 consecutive patients who underwent TAVR from 1 August 2017 to 31 March 2018, 90 of them had cardiac CT at relevant follow-up. Clinical, biological, echocardiographic, procedural characteristics and treatments were collected before, at discharge, and 1 year after TAVR. P2Y12 platelet inhibition extent and primary haemostasis disorders were investigated using platelet PRI-VASP and CT-ADP point-of-care assays. Eighty-five post-TAVR CTs out of 90 were ranked for clarity and assessed with sufficient diagnostic quality. HAM was evidenced in 13 patients (15.3%) and HALT in 30 patients (35%). Procedural characteristics, including aortic valve calcium score, annulus size, or procedural heparin regimens, were equivalent between groups. Likewise, no impact of P2Y12 inhibition (PRI-VASP) nor primary haemostasis disorders (CT-ADP) on SLT could be evidenced. No impact of SLT on valve deterioration evaluated by transthoracic echocardiography (TTE) and clinical events could be established at 12 months follow-up. By multivariate analysis, lack of oral anticoagulant therapy at discharge (HR 12.130 CI 95% (1.394-150.582); p = 0.028) and higher haemoglobin levels were evidenced as the sole independent predictors of SLT. In four patients with HAM, MDCT follow-up was obtained after initiation of OAC therapy and showed a complete regression of HAM. SLT was evidenced in a sizeable proportion of patients treated by TAVR and was mainly determined by the lack of oral anticoagulant therapy. Conversely, no impact of platelet inhibition extent on SLT could be evidenced.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA