Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 143
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Eur J Oral Sci ; 132(4): e12993, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38778467

RESUMO

This study aimed to investigate the bisphenol A (BPA) release from four CAD/CAM splint materials: three polycarbonate-based (DD BioSplint C, Splint Plus Biostar, Temp Premium Flexible) and one polymethylmethacrylate-based (Temp Basic) material. From each material, ten cylindrical samples (n = 40) were immersed in high-performance liquid chromatography (HPLC) grade water following ISO 10993-12 and incubated for 24 h in an incubation shaker at 37°C and 112 rpm. Following BPA derivatization, analysis was performed by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). After 24 h of incubation, all investigated materials released significant amounts of BPA compared to water blanks. The material-dependent elution increased in the following order: DD BioSplint C < Splint Plus Biostar < Temp Basic < Temp Premium Flexible. Subtracting extraneous BPA, the concentrations ranged between 2.27 ng/mL and 12.65 ng/mL. After extrapolating the concentrations in relation to the average surface area of occlusal splints, the amount of BPA per mL exceeded the Tolerable Daily Intake (TDI) set by the European Union for a person weighing 70 kg by 1.32-6.16 times. Contrary to the release from previously investigated materials, BPA elution from CAD/CAM splint materials was highly elevated. Considering the increasing adaptation of CAD/CAM techniques, elution from them may represent a relevant BPA source in daily dental practice.


Assuntos
Compostos Benzidrílicos , Desenho Assistido por Computador , Fenóis , Compostos Benzidrílicos/análise , Compostos Benzidrílicos/química , Fenóis/análise , Cromatografia Líquida de Alta Pressão , Cimento de Policarboxilato/química , Polimetil Metacrilato/química , Espectrometria de Massas em Tandem , Teste de Materiais , Contenções , Materiais Dentários/química , Humanos
2.
Arch Phys Med Rehabil ; 105(4): 655-663, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38163530

RESUMO

OBJECTIVE: This study compares the clinical and ultrasonographic efficacy of 2 splint types, the lateral epicondylitis band (LEB) and the wrist extensor splint (WES), for treatment of lateral epicondylitis (LE). DESIGN: Randomized controlled single-blind trial. SETTING: Outpatient clinic. PARTICIPANTS: 159 participants diagnosed with unilateral LE based on clinical and ultrasonographic findings, and 2-12 weeks from symptom onset, were included (N=159). INTERVENTIONS: One group received joint-protection education-only (wait-and-see), while the other 2 groups were fit with splints: one the LEB and the other the WES. Both splint groups received joint-protection education. MAIN OUTCOME MEASURES: The primary outcome measure was the Patient-Rated Tennis Elbow Evaluation (PRTEE) questionnaire. Secondary outcome measures were the Visual Analog Scale (VAS) for pain, hand grip strength by dynamometry, algometric measurements, patient satisfaction, and selected ultrasonographic parameters (maximum tendon thickness measurements (MTTM) in the capitellar-radiocapitellar region and total ultrasonography scale score [TUSS]). All outcomes were assessed at baseline, 3-weeks, and 6-weeks post intervention initiation. RESULTS: Participants' mean age was 46.85±8.63 years. Of the participants, 40.88% (n=65) were male and 59.12% (n=94) were female. The baseline median (1Q-3Q) values of PRTEE-total scores were 58.5 (51-68) for the LEB, 63.5 (56.25-70.25) for the WES and 57 (48-68) for the education-only groups. At 6-weeks, the PRTEE-total scores had decreased by 44 points for those randomized to the LEB, 46 points to the WES and 7 points in the education-only groups(P<.001). While the LEB and WES approaches were superior to the wait-and-see approach in algometric measurements, VAS, and PRTEE scores (P<.05), no significant changes were found in MTTM and TUSS values. The LEB group was superior to the WES group in hand grip strength and patient satisfaction (P<.05). CONCLUSION: Using either splint for 6 weeks can be considered effective for the relief of pain and increased functionality in persons with subacute LE, although the LEB had a more positive effect on grip strength and patient satisfaction than the WES.


Assuntos
Artropatias , Cotovelo de Tenista , Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Cotovelo de Tenista/terapia , Cotovelo de Tenista/tratamento farmacológico , Contenções , Força da Mão , Resultado do Tratamento , Estudos Prospectivos , Método Simples-Cego , Dor
3.
BMC Musculoskelet Disord ; 25(1): 261, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38570756

RESUMO

BACKGROUND: Non-operative management is typically indicated for extra-articular distal radius fractures. Conservative treatments such as Sugar tong splints (STs) and Muenster splints (MUs) are commonly used. However, there is limited research and outcome data comparing the two splint types. Therefore, this study aimed to investigate and compare the radiographic and clinical outcomes of treatment using STs and MUs. METHODS: In this retrospective comparative study, we aimed to evaluate and compare the radiographic and clinical outcomes of STs and MUs for the treatment of distal radius fractures. The study included 64 patients who underwent closed reduction (CR) in the emergency room and were treated with either STs or MUs splints (STs group: n = 38, MUs group: n = 26). Initial X-rays, post-CR X-rays, and last outpatient follow-up X-rays were evaluated. Radial height (RH), ulnar variance (UV), radial inclination (RI), and volar tilt (VT) were measured by a blinded investigator. The Quick DASH form was applied to measure patients' satisfaction after treatments. RESULTS: There were no significant differences in baseline characteristics, initial radiographic measurements, or radiographic measurements immediately after CR between the two groups. However, the overall radiological values deteriorated to some degree in both groups compared to the post-CR images. Furthermore, using a paired test, the STs group showed significant differences in RH and RI, and the MUs group showed significant differences in RH and UV between the last follow-up and post-CR images. CONCLUSIONS: The study concluded that there was no difference in clinical outcomes between the two splint types. However, both STs and MUs groups showed reduced radiographic parameters, and the MUs group showed a significant reduction of RH and UV in the treatment of distal radius fractures. LEVEL OF EVIDENCE: Level IV; Retrospective Comparison; Treatment Study.


Assuntos
Fraturas do Rádio , Fraturas do Punho , Humanos , Resultado do Tratamento , Estudos Retrospectivos , Contenções , Açúcares , Fraturas do Rádio/terapia , Fraturas do Rádio/cirurgia , Amplitude de Movimento Articular , Placas Ósseas , Fixação Interna de Fraturas/métodos
4.
BMC Musculoskelet Disord ; 25(1): 163, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38383364

RESUMO

BACKGROUND: There is a controversy on the effectiveness of post-operating splinting in patients with carpal tunnel release (CTR) surgery. This study aimed to systematically evaluate various outcomes regarding the effectiveness of post-operating splinting in CTR surgery. METHODS: Multiple databases, including PubMed, EMBASE, CINAHL, Web of Science, and Cochrane, were searched for terms related to carpal tunnel syndrome. A total of eight studies involving 596 patients were included in this meta-analysis. The quality of studies was evaluated, and their risk of bias was calculated using the methodological index for non-randomized studies (MINORS) and Cochrane's collaboration tool for assessing the risk of bias in randomized controlled trials. Data including the visual analogue scale (VAS), pinch strength, grip strength, two-point discrimination, symptom severity score (SSS), and functional status scale (FSS) were extracted. RESULTS: Our analysis showed no significant differences between the splinted and non-splinted groups based on the VAS, SSS, FSS, grip strength, pinch strength, and two-point discrimination. The calculated values of the standardized mean difference (SMD) or the weighted mean difference (WMD) and a 95% confidence interval (CI) for different variables were as follows: VAS [SMD = 0.004, 95% CI (-0.214, 0.222)], pinch strength [WMD = 1.061, 95% CI (-0.559, 2.681)], grip strength [SMD = 0.178, 95% CI (-0.014, 0.369)], SSS [WMD = 0.026, 95% CI (- 0.191, 0.242)], FSS [SMD = 0.089, 95% CI (-0.092, 0.269)], and the two-point discrimination [SMD = 0.557, 95% CI (-0.140, 1.253)]. CONCLUSIONS: Our findings revealed no statistically significant differences between the splinted and non-splinted groups in terms of the VAS, SSS, FSS, grip strength, pinch strength, and two-point discrimination. These results indicate that there is no substantial evidence supporting a significant advantage of post-operative splinting after CTR.


Assuntos
Síndrome do Túnel Carpal , Força da Mão , Contenções , Humanos , Síndrome do Túnel Carpal/cirurgia , Síndrome do Túnel Carpal/fisiopatologia , Resultado do Tratamento , Cuidados Pós-Operatórios/métodos
5.
BMC Musculoskelet Disord ; 25(1): 348, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38702659

RESUMO

OBJECTIVE: To compare the treatment effectiveness of digitized and 3D-printed repositioning splints with that of conventional repositioning splints in the treatment of anterior displacement of the temporomandibular joint disc. METHODS: This retrospective study included 96 patients with disc displacement of the anterior temporomandibular joint. They were treated with either digitally designed and 3D-printed repositioning splints or traditional splints and followed up for at least six months. Changes in signs and symptoms such as pain and mouth opening before and after treatment were recorded to evaluate treatment outcomes. RESULTS: During the first month of treatment, both the digitally designed and 3D-printed repositioning splint groups (Group B) and the traditional repositioning splint group (Group A) showed significant increases in mouth opening, with increases of 4.93 ± 3.06 mm and 4.07 ± 4.69 mm, respectively, and there was no significant difference between the two groups. Both groups had a significant reduction in visual analog scale (VAS) pain scores, with Group B showing a greater reduction of 1.946 ± 1.113 compared to 1.488 ± 0.978 in Group A (P < 0.05). By the sixth month, Group B's mouth opening further improved to 38.65 ± 3.22 mm (P < 0.05), while Group A's mouth opening did not significantly improve. Regarding pain, Group A's VAS score decreased by 0.463 ± 0.778 after one month, and Group B's score decreased by 0.455 ± 0.715; both groups showed significant reductions, but there was no significant difference between the two groups. CONCLUSION: Compared with traditional repositioning splints, digitally designed and 3D-printed repositioning splints are more effective at reducing patient pain and improving mouth opening. 3D-printed repositioning splints are an effective treatment method for temporomandibular joint disc displacement and have significant potential for widespread clinical application.


Assuntos
Luxações Articulares , Impressão Tridimensional , Disco da Articulação Temporomandibular , Transtornos da Articulação Temporomandibular , Humanos , Masculino , Estudos Retrospectivos , Feminino , Adulto , Disco da Articulação Temporomandibular/fisiopatologia , Pessoa de Meia-Idade , Transtornos da Articulação Temporomandibular/terapia , Resultado do Tratamento , Luxações Articulares/terapia , Placas Oclusais , Adulto Jovem , Medição da Dor , Amplitude de Movimento Articular , Contenções
6.
Am Fam Physician ; 110(1): 52-57, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39028782

RESUMO

Carpal tunnel syndrome (CTS) is caused by compression of the median nerve as it travels through the carpal tunnel. Patients commonly experience pain, paresthesia, and, less often, weakness in the distribution of the median nerve. Provocative maneuvers, such as the Phalen test and Tinel sign, have varying sensitivity and specificity for the diagnosis of CTS. Thenar atrophy is a late finding and highly specific for CTS. Although patients with a classic presentation of CTS do not need additional testing for diagnosis, electrodiagnostic studies can confirm the diagnosis in atypical cases, exclude other causes, and gauge severity for surgical prognosis. An abnormal nerve conduction study is useful for ruling in CTS, but a normal test does not necessarily exclude it. Over-the-counter analgesics, such as nonsteroidal anti-inflammatory drugs and acetaminophen, have not shown benefit for CTS. Patients with mild to moderate CTS initially may be offered nonsurgical treatments, such as splinting or local corticosteroid injections. Night-only splinting is as effective as continuous wear. A neutral wrist splint may be more effective than an extension splint. In patients with recent onset of CTS, corticosteroid injections provide slightly greater improvement of symptoms compared with splinting at 6 weeks, with similar outcomes at 6 months. Patients with severe CTS, including objective weakness or sensory deficits, should be offered surgical decompression. Endoscopic and open carpal tunnel release techniques are equally effective.


Assuntos
Síndrome do Túnel Carpal , Síndrome do Túnel Carpal/diagnóstico , Síndrome do Túnel Carpal/terapia , Humanos , Contenções , Eletrodiagnóstico/métodos , Condução Nervosa/fisiologia
7.
Clin Oral Investig ; 28(1): 112, 2024 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-38265487

RESUMO

OBJECTIVES: To assess the surgical accuracy of 3D virtually planned orthognathic surgery among patients with and without cleft. MATERIALS AND METHODS: This retrospective cohort study included cleft and non-cleft patients with class III malocclusion who underwent bimaxillary surgery. CBCT scans were acquired before and immediately after surgery. 3D virtual surgical planning (VSP) was performed using CBCT and digitalized dentition data. All orthognathic surgeries were performed by the same surgeons using interocclusal splints. The primary outcome variable was surgical accuracy, defined as the difference between the planned and surgically achieved maxillary movements, quantified in six degrees of freedom. Analysis of covariance was used to test for intergroup differences in surgical accuracy after correcting for differences in the magnitude of planned surgical maxillary movements. RESULTS: Twenty-eight cleft and 33 non-cleft patients were enrolled, with mean ages of 18.5 and 25.4 years, respectively (P=0.01). No significant gender difference was present between the groups (P=0.10). After adjustment for small differences in surgical movements, no significant differences in surgical accuracy were observed between cleft and non-cleft patients. CONCLUSION: The present study demonstrates that high surgical accuracy in maxillary movements can be achieved in both cleft and non-cleft patients using VSP and interocclusal splints. CLINICAL RELEVANCE: Orthognathic cases with cleft can be performed with 3D VSP to obtain a satisfactory surgical accuracy.


Assuntos
Exostose , Má Oclusão Classe III de Angle , Humanos , Adolescente , Adulto Jovem , Adulto , Estudos Retrospectivos , Movimento , Contenções
8.
Clin Oral Investig ; 28(2): 141, 2024 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-38340152

RESUMO

OBJECTIVES: Successful orthognathic surgery requires accurate transfer of the intraoperative surgical plan. This study aimed to (1) evaluate the surgical error of a novel intermediate splint in positioning the maxilla during maxilla-first orthognathic surgery and (2) determine factors influencing surgical error. MATERIALS AND METHODS: This prospective study examined 83 patients who consecutively underwent Le Fort I osteotomy for correction of skeletal class III deformity using a novel intermediate splint and a bilateral sagittal split osteotomy. Surgical error was the outcome variable, measured as the difference in postoperative translational and rotational maxillary position from the virtual plan. Measures included asymmetry, need and amount for mandibular opening during fabrication of intermediate splints, and planned and achieved skeletal movement. RESULTS: Mean errors in translation for vertical, sagittal, and transversal dimensions were 1.0 ± 0.7 mm, 1.0 ± 0.6 mm, and 0.7 ± 0.6 mm, respectively; degrees in rotation for yaw, roll, and pitch were 0.8 ± 0.6, 0.6 ± 0.4, and 1.6 ± 1.1, respectively. The transverse error was smaller than sagittal and vertical errors; error for pitch was larger than roll and yaw (both p < 0.001). Error for sagittal, transverse, and roll positioning was affected by the achieved skeletal movement (roll, p < 0.05; pitch and yaw, p < 0.001). Surgical error of pitch positioning was affected by planned and achieved skeletal movement (both p < 0.001). CONCLUSIONS: Using the novel intermediate splint when performing Le Fort I osteotomy allowed for accurate positioning of the maxilla. CLINICAL RELEVANCE: The novel intermediate splint for maxillary positioning can be reliably used in clinical routines.


Assuntos
Cirurgia Ortognática , Procedimentos Cirúrgicos Ortognáticos , Humanos , Maxila/cirurgia , Contenções , Estudos Prospectivos , Osteotomia de Le Fort/métodos , Procedimentos Cirúrgicos Ortognáticos/métodos , Imageamento Tridimensional/métodos , Cefalometria
9.
Pediatr Emerg Care ; 40(7): 566-572, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38949983

RESUMO

ABSTRACT: This review covers common orthopedic injuries seen after acute traumatic injury. A thorough physical examination and radiographic review of these injuries are key to ensuring appropriate management. Although many injuries may require urgent or emergent orthopedic consultation and management, this review focuses on injuries that are low-risk and amenable to splinting with outpatient orthopedic follow-up. This review covers key physical examination features, radiographic findings that help providers assess injuries, as well as reviewing splinting application to help facilitate rapid management of these injuries in the acute care setting.


Assuntos
Fraturas Ósseas , Contenções , Humanos , Criança , Fraturas Ósseas/terapia , Exame Físico/métodos , Radiografia
10.
Pediatr Emerg Care ; 40(1): 6-9, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38157392

RESUMO

OBJECTIVE: The aim of this study is to compare the clinical results of splint, short arm circular plaster, and soft bandage immobilization methods applied in the treatment of wrist torus fractures in a single center. METHODS: Patients treated for torus fractures at a tertiary trauma hospital between January 2018 and January 2022 were analyzed retrospectively. According to the physician's preference, a splint, short arm circular plaster, or soft bandage was applied to each patient. The treatment modalities, the number of hospital admissions during the treatment, the number of radiological imaging procedures used during the treatment, immobilization time, and the follow-up periods of the patients were checked and noted on the hospital data processing system. RESULTS: Six hundred ten patients were included in the study. It was determined that 351 patients were treated with a short arm splint, 155 with a short arm circular cast, and 104 with soft bandaging. The number of radiological imaging procedures, the number of hospital admissions during the treatment, the duration of the pain complaint, and the complication rate of the patients treated with splint were significantly lower than the groups treated with short arm circular plaster and soft bandage (P < 0.001). CONCLUSIONS: It was observed that patients who were immobilized with a short arm splint required less follow-up time and fewer imaging procedures and hospital admissions and experienced earlier pain relief and lower complication rates. We think that the use of short arm splints in the treatment of torus fractures is sufficient, safe, and advantageous.


Assuntos
Fraturas do Rádio , Traumatismos do Punho , Humanos , Estudos Retrospectivos , Rádio (Anatomia) , Fraturas do Rádio/terapia , Resultado do Tratamento , Traumatismos do Punho/etiologia , Dor/etiologia , Contenções , Moldes Cirúrgicos , Imobilização/métodos
11.
Dent Traumatol ; 40(4): 470-476, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38270265

RESUMO

BACKGROUND/AIMS: The recommendations for splinting are well established for the injuries of permanent dentition; however, ambiguity still exists for the injuries in primary dentition. Hence, this study aimed to determine the most appropriate dimensions of stainless steel wire and its extent, for achieving the physiologic mobility in primary dentition. MATERIAL AND METHODS: This study was designed as an in vitro experiment by using a typodont model of primary dentition. The baseline mobility of primary maxillary incisors was calibrated to the physiologic mobility of natural primary incisors by using a Teflon tape wrapped around the roots of resin teeth. Splinting was done using a stainless steel wire of 0.2 mm (Group I), 0.3 mm (Group II), and 0.4 mm (Group III). These groups were subdivided (a, b, and c) on the basis of the extent of the splint, and pre splint mobility (Pre-PV) and post-splint mobility (Post-PV) were tested by Periotest M. The splint effect was calculated by subtracting Post-PVs and Pre-PVs. RESULTS: The normal values of mobility in healthy human volunteers ranged from 10.5 to 13. The overall splint effect was higher in Group III irrespective of the extent of the splint, whereas it was found to be the lowest in Group I (b and c). The splint effect increased with the extent of the splint in all the groups. Among all the groups, the splint effect on the anchor teeth was observed to increase with the extent of the splint and the diameter of the wire. CONCLUSION: The mobility of the injured and anchor teeth splinted with 0.2-mm stainless steel wire was similar to the pre-splint and physiologic mobility. The most favorable extension was one tooth adjacent to the injured tooth on each side for both 0.2- and 0.3-mm wires.


Assuntos
Fios Ortodônticos , Avulsão Dentária , Mobilidade Dentária , Dente Decíduo , Humanos , Dente Decíduo/lesões , Mobilidade Dentária/terapia , Avulsão Dentária/terapia , Aço Inoxidável , Incisivo/lesões , Técnicas In Vitro , Contenções , Modelos Dentários
12.
Eur J Orthod ; 46(2)2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38376495

RESUMO

BACKGROUND: Juvenile idiopathic arthritis (JIA) frequently affects the temporomandibular joint (TMJ), which can alter mandibular growth and development and result in dentofacial deformities. OBJECTIVE: To assess the outcomes of orthopedic treatment with distraction splint (DS) in patients with JIA-related dentofacial deformity. METHODS: The retrospective study involved 30 patients with JIA and unilateral TMJ involvement, another study group of 20 patients with JIA and bilateral TMJ involvement, and a control group of 18 non-JIA orthodontic patients with Class II and III malocclusions. The inclusion criteria were DS treatment and cone-beam computed tomography (CBCT) scans before (T0) and 2 years after treatment (T1). Dentofacial morphology and deformity were evaluated based on a validated three-dimensional CBCT-based morphometric analysis. Intergroup differences in outcome measures were compared at T0 and T1, and intragroup changes between T0 and T1 were assessed using the Kruskal-Wallis test. RESULTS: Initial evaluations at T0 revealed significant differences between the unilateral and bilateral JIA groups and the control group for three out of eight dentofacial deformity variables: inter-side difference in total posterior mandibular height, mandibular axial angle, and posterior/anterior face height (ratio). At follow-up (T1), significant inter-group differences were only observed in total posterior mandibular height indicating that intergroup differences were less pronounced after splint treatment. Assessing inter-group changes between T0 and T1 showed that all parameters remained constant except posterior/anterior face height ratio, which significantly decreased between T0 and T1. CONCLUSIONS: The findings demonstrate the potential of DS treatment for patients with JIA and unilateral or bilateral TMJ involvement to generally support normal dentofacial growth or at least limit further deterioration of dentofacial deformities.


Assuntos
Artrite Juvenil , Deformidades Dentofaciais , Humanos , Artrite Juvenil/complicações , Artrite Juvenil/diagnóstico por imagem , Artrite Juvenil/terapia , Deformidades Dentofaciais/diagnóstico por imagem , Deformidades Dentofaciais/terapia , Estudos Retrospectivos , Contenções , Mandíbula/diagnóstico por imagem
13.
J Oral Implantol ; 50(1): 50-64, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38329841

RESUMO

The choice of a splinted or nonsplinted implant-supported prosthesis should be based on solid scientific evidence that considers the conditions and needs of each patient. This review elaborates on the factors that directly influence clinical decisions between splinted or nonsplinted dental implants. Digital and manual searches of the published literature were conducted to identify studies that examined splinted prostheses (SPs) and nonsplinted prostheses (NSPs). The search terms used, alone or in combination, were "splinting prosthesis," "nonsplinting prosthesis," "prosthetic design," "stress distribution in dental implant," "implant loading," "implant occlusion," and "crestal bone resorption." Ninety-four studies were selected to compare and address the details emphasized in this study. Thirty-four reported articles were not directly related to restoration design but were reviewed to better understand the influence of mechanical risk factors, finite element analysis limits, and criteria for implant survival and treatment success. There are advantages and disadvantages of splinting implants together. NSPs are the ideal choice because they resemble natural teeth. Splinting a restored implant will cause the implant to appear as part of one unit and is indicated in more compromised situations, unfavorable conditions, or when pontic spaces and cantilevers are needed in implant prostheses.


Assuntos
Implantes Dentários , Humanos , Planejamento de Prótese Dentária , Prótese Dentária Fixada por Implante , Resultado do Tratamento , Contenções
14.
BMC Oral Health ; 24(1): 296, 2024 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-38431564

RESUMO

BACKGROUND: Overerupted maxillary molars is common in adults, which can lead to insufficient intermaxillary vertical space ,great difficulty in prosthetic reconstruction ,and cause occlusal interference in movements.To reconstruct occlusal function, it is necessary to prepare enough space for prostheses. The aim of the present study was to evaluate the effect of space-adjustment occlusal splint on overerupted maxillary molars by clinical and electromyographic signals analysis. METHODS: Eighteen patients with overerupted maxillary molars were selected to wear space-adjustment occlusal splint suppressing overerupted maxillary molars for three months. Satisfaction was assessed by 5-point Likert; intermaxillary vertical space and the teeth transportation distance were measured in models; clinical periodontal status were evaluated by periodontal probing depth (PPT) and bleeding index (BI); electromyographic recordings of the masseter and anterior temporal muscles were monitored by Cranio-Mandibular K7 Evaluation System. RESULTS: All the patients were satisfied with the treatment effect (Likert scale ≧ 4). The intermaxillary space in edentulous areas after treatment showed statistically significant increasing when compared with those before treatment. PPT and BI showed no significant difference. No statistically significant differences were found in electromyographic activity of anterior temporal muscles, while a reduction of muscle activity in masseter in the contralateral side were detected in post-treatment evaluations compared with pre-treatment at mandibular rest position. CONCLUSIONS: Space-adjustment occlusal splint is an efficient treatment option on overerupted maxillary molars by intruding the maxillary molar to obtain adequate intermaxillary space for prostheses.


Assuntos
Dente Molar , Contenções , Adulto , Humanos , Dente Molar/cirurgia , Músculo Masseter/fisiologia , Músculo Temporal/fisiologia , Placas Oclusais , Eletromiografia
15.
BMC Oral Health ; 24(1): 363, 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38515064

RESUMO

BACKGROUND: Temporomandibular disorders (TMDs) encompass pain and dysfunction in the jaw, muscles, and adjacent structures. This study aimed to explore the quantitative (condylar position, morphology) and qualitative (bone mineral density (BMD)) therapeutic outcomes following a stabilization splint (S.S.) therapy in adult patients diagnosed with TMD (Arthralgia) with/without lateral mandibular asymmetry (MA) using cone beam computed tomography (CBCT). METHODS: In this retrospective clinical study, 60 adult TMD patients who received S.S. therapy were enrolled and allocated into the TMD group (TMDG) and TMD with MA group (TMD + MAG). The diagnosis was made according to the Diagnostic Criteria for TMD (DC/TMD) AXIS I. MA was measured from the mid-sagittal plane to the Menton point. CBCT was used to scan the temporomandibular joints pre- (T0) and post- (T1)-treatment for three-dimensional analysis. Intra- and intergroup statistical comparisons were performed using the Wilcoxon signed ranks and the Kruskal‒Wallis test. RESULTS: For quantitative comparisons, there was a statistically significant difference between T0 and T1 in the joint spaces of TMD + MAG (anterior, superior, posterior, and coronal lateral on the deviated side as well as in the superior, coronal medial joint space of the contralateral side). Morphologically, the deviated side had a narrower condylar width, reduced condylar height, and a steeper eminence angle. In contrast, the contralateral side tended to have a greater condylar length. For qualitative measurements, BMD also showed statistical significance between T0 and T1 in the majority of the condyle slopes (AS, SS, PS, and LS on the deviated side and in AS and MS on the contralateral side) of TMD + MAG. Additionally, only the AS and PS showed significance in TMDG. CONCLUSION: Multiple joint space widening (AJS and CMS) and narrowing (SJS, PJS, and CLS) could characterize the deviated side in TMD + MA. Factors like narrower condylar width, reduced condylar height, and steeper eminence angle on the deviated side can worsen TMD + MA. Proper alignment of the condyle-disc position is essential for optimal function and load distribution, potentially affecting bone mineral density (BMD). MA plays a prominent role in disturbing bone densities. S.S. therapy shows more evident outcomes in TMD + MAG (on the deviated side compared to the contralateral side) than the TMDG.


Assuntos
Côndilo Mandibular , Transtornos da Articulação Temporomandibular , Adulto , Humanos , Côndilo Mandibular/diagnóstico por imagem , Contenções , Estudos Retrospectivos , Articulação Temporomandibular/diagnóstico por imagem , Transtornos da Articulação Temporomandibular/diagnóstico por imagem , Transtornos da Articulação Temporomandibular/terapia , Tomografia Computadorizada de Feixe Cônico
16.
BMC Oral Health ; 24(1): 479, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38643111

RESUMO

BACKGROUND: Temporomandibular disorder (TMD) is a grouping of heterogeneous disorders with multifactorial origins. Stabilization splints (SS) have demonstrated an acceptable treatment effect in TMD. The possible changes at the skeletal, dental, and soft tissue levels need to be addressed to evaluate the benefit/risk ratio of this therapeutic procedure. Accordingly, this study aimed to three­dimensionally evaluate skeletal, dentoalveolar and soft tissue changes after SS treatment for patients with TMD. METHODS: This retrospective study included 74 adult patients with myofascial and/or intra-articular disorders (25 males and 49 females), with an average age of 22.88 ± 4.8 years, who underwent SS treatment. Pre- and post-treatment Cone beam computed tomography were analysed using Invivo 6.0.3 software. The primary outcome was the vertical skeletal and dentoalveolar changes, while the secondary outcomes were the anteroposterior skeletal, dentoalveolar and soft tissue changes. Paired t-test and Wilcoxon rank sum test were used for statistical analyses. RESULTS: For the primary outcome; skeletally, there was a significant increase in mandibular plane inclination (difference: 0.82°±1.37), decrease facial height ratio (difference: 0.45%±1.07) and at the dentoalveolar level, the inclination of the functional (FOP-SN, FOP-FH) and bisecting (BOP-SN, BOP-FH) occlusal planes exhibited a significant increase too (difference: 0.38 ± 1.43°, 0.49 ± 1.62°, 0.44 ± 1.29° and 0.41 ± 1.17°, respectively) and also a decrease in the overbite (difference: -0.54 ± 0.83). For the secondary outcomes; there was a significant decrease in mandibular position (SNB) (difference: 1.60 ± 1.36°) and increase in the overjet (difference: 0.93 ± 1.04, p < 0.001) and a significant lower lip retrusion (difference: 0.33 ± 1.01 mm p < 0.01), was observed too. CONCLUSIONS: SS therapy resulted in significant vertical skeletal and dentoalveolar changes that were manifested mainly by facial height ratio, mandibular and occlusal plane changes, and to a lesser extent, significant anteroposterior skeletal, dentoalveolar, and soft tissue changes in the form of mandibular position, increased overjet and a more retrusive lower lip. These changes should be considered during patients' selection prior to initiating SS therapy.


Assuntos
Má Oclusão Classe II de Angle , Sobremordida , Transtornos da Articulação Temporomandibular , Masculino , Adulto , Feminino , Humanos , Adolescente , Adulto Jovem , Maxila , Estudos Retrospectivos , Contenções , Cefalometria/métodos , Mandíbula/diagnóstico por imagem , Sobremordida/terapia , Má Oclusão Classe II de Angle/terapia , Transtornos da Articulação Temporomandibular/diagnóstico por imagem , Transtornos da Articulação Temporomandibular/terapia , Articulação Temporomandibular
17.
Wiad Lek ; 77(3): 462-471, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38691788

RESUMO

OBJECTIVE: Aim: To study the specifics of the impact of immediate intraoperative loading with a splinting component on supporting tissues during a one-stage implantation protocol. PATIENTS AND METHODS: Materials and Methods: In the course of the study, orthopedic treatment was carried out for 55 patients aged 29 to 60 years. The following were performed: cone-beam computed tomography, software planning and intraoral scanning with an optical scanner, one-stage implantation protocol, assessment of implant stability with the Osstell ISQ device, microcirculation study in the peri-implant area using laser Doppler flowmetry (LDF). RESULTS: Results: It was established that around loaded implants there is an increase in blood flow and vasomotor activity of the microcirculatory channel of the supporting tissues, an increase in the volume of bone tissue and an increase in torque, which is the optimal forecast for the acceleration of the pace of osseointegration. CONCLUSION: Conclusions: The use of a splinting component during immediate intraoperative functional masticatory load accelerates the dynamics of bone tissue remodeling processes around the implant, which is an optimal prediction of osseointegration rates in various dental implantation protocols and is consistent with high values of the implant stability coefficient.


Assuntos
Carga Imediata em Implante Dentário , Humanos , Pessoa de Meia-Idade , Adulto , Masculino , Feminino , Contenções , Osseointegração , Implantes Dentários , Implantação Dentária Endóssea/métodos , Tomografia Computadorizada de Feixe Cônico
18.
Niger J Clin Pract ; 27(4): 430-434, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38679763

RESUMO

BACKGROUND: Various types of nasal tampons are used for packing after septoplasty. Intranasal splints are widely used as they are more advantageous than other materials regarding the lower complication rates of synechia, and lesser pain during removal. However, there is no consensus on the timing of intranasal splint removal after septoplasty operations. AIM: In this study, we aimed to investigate the effects of removal time of intranasal splints on postoperative complications after septoplasty. METHODS: One hundred patients who had septoplasty were randomly divided into two groups according to splint removal time. In group I, the splints were removed on the third postoperative day and in group II, splints were removed on the seventh postoperative day. Pain during splint removal was evaluated by visual analog scale (VAS). Complications of hemorrhage, septal hematoma, crusting, mucosal injury, and infection were recorded during splint removal and compared. In the first postoperative month, hemorrhage, crusting, mucosal injury, infection, synechia, and in the second postoperative month, synechia and perforation rates were compared between two groups. RESULTS: Mucosal crusting was significantly higher in group II during splint removal. There was no statistically significant difference between the two groups regarding the complication rates and pain scores. Our findings showed no significant difference in pain scores during splint removal and postoperative complications between the two groups except for mucosal crusting. CONCLUSION: Based on our findings, although there is no consensus on the optimal time for splint removal, earlier removal of splints can be considered a favorable option after septoplasty operations.


Assuntos
Septo Nasal , Complicações Pós-Operatórias , Contenções , Humanos , Feminino , Masculino , Adulto , Septo Nasal/cirurgia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Rinoplastia/efeitos adversos , Rinoplastia/métodos , Fatores de Tempo , Pessoa de Meia-Idade , Adulto Jovem , Tampões Cirúrgicos , Remoção de Dispositivo , Dor Pós-Operatória/etiologia , Dor Pós-Operatória/epidemiologia , Adolescente , Medição da Dor
19.
Eur J Orthop Surg Traumatol ; 34(5): 2457-2464, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38796813

RESUMO

PURPOSE: Ankle fracture-dislocations (AFD) often necessitate staged management involving temporary external fixation (EF) due to mechanical instability or blistering. However, limited literature exists on the optimal temporary immobilization method for low-energy closed AFD. This study compared baseline patient and fracture characteristics, along with clinical and radiological outcomes between AFD initially immobilized with EF versus splinting. METHODS: A retrospective cohort study was conducted involving patients with AFD temporarily immobilized using EF or splinting, followed by definitive open reduction and internal fixation. Quality of reduction (QOR) was assessed for each patient post-initial immobilization and after the definitive surgery. RESULTS: The study encompassed 194 patients: 138 treated with a splint (71.1%) and 56 (28.9%) with EF. Secondary loss of reduction had occurred in three patients who were splinted (2.2%). The mean ages in the EF and splint groups were 63.2 and 56.1 years, respectively (p = 0.01). Posterior malleolus fracture (PMF) and blisters were more prevalent in EF patients (69.6% vs. 43.5% for PMF and 76.8% vs. 20.3% for blisters, respectively; p = 0.05 and p < 0.01). Postoperative complication rates were 8.9% for EF versus 10.9% for splinting (p = 0.69). Satisfactory final QOR was attained in 79.8% of patients treated with a splint versus 64.3% with EF (p = 0.02). CONCLUSION: Patients immobilized by EF presented with poorer baseline characteristics and had more unstable injuries. Nevertheless, postoperative complication rates were comparable. Thus, EF appears to be a valuable tool for standardizing outcomes in AFD patients with a less favorable prognosis.


Assuntos
Fraturas do Tornozelo , Fratura-Luxação , Imobilização , Contenções , Humanos , Estudos Retrospectivos , Masculino , Fraturas do Tornozelo/cirurgia , Feminino , Pessoa de Meia-Idade , Fratura-Luxação/cirurgia , Fratura-Luxação/diagnóstico por imagem , Imobilização/métodos , Fixação Interna de Fraturas/métodos , Idoso , Redução Aberta/métodos , Adulto , Resultado do Tratamento , Fixadores Externos
20.
Clin Oral Investig ; 28(1): 54, 2023 Dec 29.
Artigo em Inglês | MEDLINE | ID: mdl-38157078

RESUMO

OBJECTIVES: This study is to evaluate the color stability, surface roughness, and hardness of additively manufactured and hand-cast splint materials after a 6-month commercially available denture cleaning tablet immersion simulation. MATERIALS AND METHODS: Disc-shaped additively manufactured and hand-cast auto polymerizing acrylic resin specimens were prepared (N = 40 each). All specimens were exposed to coffee solution totally 2 days. Thereafter, all specimens were immersed into three different effervescent solutions that simulated 6 months of clinical use. The total color change (ΔE*ab), surface roughness (Ra), and Vickers hardness (Vh) were measured at baseline and after immersion protocols. A two-way ANOVA and Bonferroni's post hoc test were used for color change. The dependent t-test and ANOVA were used for roughness and hardness evaluation. RESULTS: Additively manufactured splint materials were more affected by coffee immersion. It was observed that all denture cleaning tablets induced a noticeable alteration in color of the specimens (p < 0.05). Roughness and hardness measurement changes after solution immersions were statistically significant for both splint groups (p < 0.05). On the other hand, distilled water and denture cleaning tablets created similar roughness and hardness measurements at baseline and after immersion. CONCLUSIONS: After 6 months use of tested cleaning tables, the color stability, surface roughness, and hardness of both groups were affected. The evaluation of the surface properties of splint materials could be recommended to the dentists in periodic controls during splint treatments. CLINICAL RELEVANCE: The use effervescent denture cleaning tablets altered the surface characteristics of tested splint materials over time with nonsignificant difference between each other. After 6 months, awareness should be raised about surface characteristics of splint materials.


Assuntos
Café , Bases de Dentadura , Contenções , Resinas Acrílicas , Propriedades de Superfície , Teste de Materiais , Cor
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA