Ophthalmic Physiol Opt ; 44(3): 483-490, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38372370

RESUMO

PURPOSE: Previous research has shown that accommodation deficits are common in individuals with Down syndrome (DS), but the origin and mechanisms behind these deficits are still unknown. The aim of this study was to investigate the characteristics of different ocular structures involved in accommodation, in particular the ciliary muscle (CM), in a population of individuals with DS to further understand this deficit and its mechanisms. METHODS: Thirty-two volunteer participants of pre-presbyopic age with (n = 16) and without DS (n = 16) were recruited. Temporal and nasal images of the CM were acquired using anterior segment optical coherence tomography (AS-OCT) while participants fixated an eccentrically located target. Analysis of CM parameters was undertaken using validated semi-automated software. Axial length, anterior chamber depth, lens thickness and corneal curvature were obtained with the Topcon Aladdin Optical Biometer and Corneal Topographer. Non-cycloplegic refractive error and accommodative ability were obtained with an open-field autorefractor and dynamic retinoscopy, respectively. Independent t-tests were conducted to determine differences in CM and other anterior segment parameters between participants with and without DS. RESULTS: No significant differences were found in the CM parameters studied between participants with and without DS (p > 0.05). In contrast, significant differences were found in visual acuity (p < 0.001), accommodative response (p < 0.001) and corneal curvature (K1 p = 0.003 and K2 p < 0.001) between participants with and without DS. CONCLUSIONS: Despite having poorer accommodation, pre-presbyopic adults with DS do not have a different CM morphology to that found in typically developing adults. These findings suggest that the accommodative deficit found in this population is not due to a mechanical deficit of the CM.


Assuntos
Síndrome de Down , Cristalino , Adulto , Humanos , Cristalino/anatomia & histologia , Corpo Ciliar/diagnóstico por imagem , Corpo Ciliar/anatomia & histologia , Corpo Ciliar/fisiologia , Acomodação Ocular , Tomografia de Coerência Óptica/métodos , Músculos
2.
Ophthalmic Physiol Opt ; 44(5): 1041-1051, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38676399

RESUMO

PURPOSE: This study compared in vivo crystalline lens shape measurements using B-scan images from the IOLMaster 700 with phakometry. METHODS: Twenty-four young adult participants underwent IOLMaster 700 and phakometry measurements under cycloplegia (1% cyclopentolate). The IOLMaster 700 generated B-scan images along six meridians in 30° increments, which were analysed using custom MATLAB software to determine lens surface radii of curvature. Phakometry measurements were obtained using Purkinje images reflected from the lens surfaces. RESULTS: The IOLMaster 700 image analysis method yielded a lower mean anterior lens surface spherical equivalent power (+6.20 D) than phakometry (+7.55 D); however, the two measurements were strongly correlated (R(21) = 0.97, p < 0.0001). The astigmatic power vectors (J0 and J45) for the anterior lens surface were significantly higher for the IOLMaster 700 measurements, with only J0 showing a significant moderate positive correlation (R(21) = 0.57, p = 0.005). For the posterior lens surface, the IOLMaster 700 measurements had a higher mean spherical power (+14.28 D) compared to phakometry (+13.70 D); however, a strong positive correlation (R(21) = 0.90, p < 0.0001) was observed. No significant correlations were noted for posterior lens surface astigmatic vectors (J0 and J45). The IOLMaster 700 estimates for the equivalent lens mean spherical power were slightly lower than those for phakometry, with a mean difference of -0.72 D, and both methods were positively correlated (R(21) = 0.94, p < 0.0001). CONCLUSIONS: The findings demonstrate that IOLMaster 700 B-scan image analysis technique provides similar estimates of lens surface powers to phakometry. These results highlight the potential of the IOLMaster 700 to provide measurements of lens shape, informing future research and clinical use.


Assuntos
Cristalino , Humanos , Cristalino/diagnóstico por imagem , Cristalino/anatomia & histologia , Feminino , Masculino , Adulto , Adulto Jovem , Refração Ocular/fisiologia , Biometria/métodos
3.
Ann Biomed Eng ; 52(8): 1982-1990, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38503945

RESUMO

The process of lens shape change in the eye to alter focussing (accommodation) is still not fully understood. Modelling approaches have been used to complement experimental findings in order to determine how constituents in the accommodative process influence the shape change of the lens. An unexplored factor in modelling is the role of the modelling software on the results of simulated shape change. Finite element models were constructed in both Abaqus and Ansys software using biological parameters from measurements of shape and refractive index of two 35-year-old lenses. The effect of zonular insertion on simulated shape change was tested on both 35-year-old lens models and with both types of software. Comparative analysis of shape change, optical power, and stress distributions showed that lens shape and zonular insertion positions affect the results of simulated shape change and that Abaqus and Ansys show differences in their respective models. The effect of the software package used needs to be taken into account when constructing finite element models and deriving conclusions.


Assuntos
Análise de Elementos Finitos , Cristalino , Modelos Biológicos , Cristalino/fisiologia , Cristalino/anatomia & histologia , Humanos , Simulação por Computador , Acomodação Ocular/fisiologia , Adulto , Software
4.
Curr Eye Res ; 49(6): 671-681, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38379315

RESUMO

PURPOSE: Accommodation mainly affects the lens, a structure of the eyeball that degrades with age. The aim of this work was to study the morphological changes of different ocular structures during accommodation, both in the anterior pole and the posterior pole, which may also be involved in the accommodation process. METHODS: The study will be carried out by stimulating accommodation through lenses of -1.00, -3.00 and -5.00 D starting from the spherical equivalent (M) of each participant in different age groups, from 18 to 66 years. To obtain the M value, aberrometry was achieved, and retinal optical coherence tomography and anterior pole tomography were performed to evaluate the possible structural modifications (central and peripheral), while accommodation was progressively stimulated. RESULTS: It showed that as the accommodative demand increased, morphological changes were produced in retinal thickness, both in the central and peripheral retina, in all age groups. A thinning of the retina was observed in the central 3 mm, while significant progressive thickening was observed closer to the periphery (up to 6 mm from the fovea) as the required accommodative power increased. A decrease in the anterior chamber depth (ACD) and anterior chamber volume (ACV) was observed with increasing lens power. CONCLUSION: Structural changes were observed in the central and peripheral retina, as well as in the ACD and ACV, while progressively greater accommodation was stimulated, showing that these structures were modified in the accommodation process even in advanced presbyopes.


Assuntos
Acomodação Ocular , Envelhecimento , Câmara Anterior , Retina , Tomografia de Coerência Óptica , Humanos , Acomodação Ocular/fisiologia , Tomografia de Coerência Óptica/métodos , Adulto , Pessoa de Meia-Idade , Idoso , Adulto Jovem , Câmara Anterior/diagnóstico por imagem , Retina/diagnóstico por imagem , Masculino , Adolescente , Envelhecimento/fisiologia , Feminino , Cristalino/diagnóstico por imagem , Cristalino/fisiologia , Cristalino/anatomia & histologia , Refração Ocular/fisiologia
5.
Ultrasound Med Biol ; 50(9): 1346-1351, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38866649

RESUMO

OBJECTIVE: To compare anterior chamber depth (ACD) and lens thickness (LT) measurements by ultrasound biomicroscopy (UBM), A-scan cross vector (CV) overlay with UBM, and immersion A-scan technique in pediatric eyes. METHODS: This prospective comparative cohort study comprised 43 eyes of 25 pediatric participants (mean age: 2.3±2.2 y). UBM and immersion A-scan biometry were performed prior to dilation and intraocular surgery. ACD and LT were measured by UBM image analysis, A-scan CV UBM overlay, and immersion A-scan technique. RESULTS: ACD and LT measurements obtained using immersion A-scan were significantly greater than with UBM image analysis with mean differences of 0.52 mm and 0.62 mm, respectively (p < 0.001). Immersion A-scan and UBM measurements were moderately correlated (r = 0.70 and 0.64, p < 0.001). ACD and LT measurements obtained using CV overlay were not significantly different than UBM measurements and the values were strongly positively correlated (r = 0.95 and 0.93, p < 0.001). CONCLUSION: Immersion A-scan may overestimate ACD and LT compared to UBM in pediatric patients due to oblique placement of the A-scan probe relative to the optical axis. Supplemental use of UBM and/or CV overlay is indicated to improve measurement accuracy in pediatric patients who cannot reliably fixate due to the ability to confirm proper alignment of the probe with the pupil by visualizing the anterior segment.


Assuntos
Câmara Anterior , Biometria , Cristalino , Microscopia Acústica , Humanos , Câmara Anterior/diagnóstico por imagem , Câmara Anterior/anatomia & histologia , Microscopia Acústica/métodos , Feminino , Masculino , Cristalino/diagnóstico por imagem , Cristalino/anatomia & histologia , Pré-Escolar , Estudos Prospectivos , Biometria/métodos , Reprodutibilidade dos Testes , Criança , Lactente , Estudos de Coortes , Sensibilidade e Especificidade
6.
Invest Ophthalmol Vis Sci ; 65(6): 23, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38874964

RESUMO

Purpose: To explore differences in the relationship between gestational age (GA) and birth weight (BW) percentile and ocular geometry between males and females. Methods: The Gutenberg Prematurity Eye Study involved a prospective ophthalmic examination of adults, aged 18 to 52 years, who were born preterm or at term, in Germany. The associations between GA and BW percentile on the main outcome measures were evaluated by uni- and multivariable linear regression analyses. The main outcome measures were central corneal thickness, corneal radius, anterior chamber depth, lens thickness, posterior segment length, and central foveal thickness. Potential sex-specific differences and an effect modification by sex were analyzed. Results: This study involved 438 participants (245 females, 193 males) with an average age of 28.6 ± 8.7 years. In female participants, central foveal thickness was negatively associated with a higher GA (B = -2.99; P < 0.001). Similarly, male participants also demonstrated a negative association between central foveal thickness and GA (B = -4.27; P < 0.001). The multivariable model with effect modification revealed that the central foveal thickness was thicker with lower GA. There was an association between the effect modification of GA with sex and central foveal thickness, demonstrating a more pronounced effect of GA on central foveal thickness in male participants (B = 1.29; P = 0.04). Conclusions: This study identified a sex-specific correlation between lower GA and thicker central foveal thickness, suggesting differences in the developmental trajectory of this biometric parameter concerning GA. A thicker central foveal thickness might affect the visual acuity of individuals born preterm in adulthood, with a more pronounced impact in males and a potential predisposition to age-related diseases later in life. Sex did not influence the association of GA or BW percentile to other ocular geometric parameters.


Assuntos
Peso ao Nascer , Idade Gestacional , Humanos , Masculino , Feminino , Estudos Prospectivos , Adulto , Adulto Jovem , Adolescente , Pessoa de Meia-Idade , Peso ao Nascer/fisiologia , Fatores Sexuais , Recém-Nascido , Fóvea Central/diagnóstico por imagem , Córnea/anatomia & histologia , Córnea/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Câmara Anterior/diagnóstico por imagem , Câmara Anterior/anatomia & histologia , Recém-Nascido Prematuro , Cristalino/diagnóstico por imagem , Cristalino/anatomia & histologia , Alemanha , Acuidade Visual/fisiologia , Segmento Posterior do Olho/diagnóstico por imagem , Segmento Posterior do Olho/anatomia & histologia , Segmento Posterior do Olho/patologia
7.
Arq. bras. oftalmol ; 82(1): 56-61, Jan.-Feb. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-973867

RESUMO

ABSTRACT Purpose: The porcine eye is frequently used as a research model. This paper analyzes the effect of different storage methods on the transparency of pig crystalline lens. Methods: A spectral transmission curve (from 220 to 780 nm) for the crystalline lens was determined experimentally after storage in different conditions: saline solution, formalin, castor oil, and freezing at -80°C. The total transmission in the visible spectrum, which was used as an index of transparency, was calculated from these curves. For comparative purposes, fresh lenses were evaluated and used as controls. Results: Storing the porcine crystalline lens in saline solution or castor oil resulted in a transparency loss of approximately 10% after 24 h and storage in formalin resulted in a loss of nearly 30%. Storage by freezing at -80°C for 4 weeks maintained the transparency of the crystalline lens; the spectral transmission measured immediately after defrosting at room temperature coincided exactly with that of the freshly extracted lens. Conclusions: The transparency of porcine crystalline lens is affected by the storage method. The visible spectrum is the most affected, evidenced by the effect on the transparency and consequently the amount of light transmitted. The results show that freezing at -80°C maintains the transpa rency of the crystalline lens for at least 4 weeks.


RESUMO Objetivos: Olho de porco é frequentemente usa do como modelos de pesquisa. Este estudo analisa o efeito de di ferentes métodos de armazenamento na preservação da transparência do cristalino de porco. Métodos: Uma curva de transmissão espectral (de 220 até 780 nm) para o cristalino foi experimentalmente determinada após armazenamento em diferentes condições: solução salina, formol, óleo de mamona e congelamento a -80°C. Transmissão total do espectro visível, que foi usada como um índice de transparência foi calculada a partir dessas curvas. Para fins comparativos, lentes frescas foram avaliadas e usadas como controles. Resultados: O armazenamento do cristalino suíno em solução salina ou óleo de mamona resultou uma perda de transparência de aproximadamente 10% após 24 h e o armazenamento em formol resultou uma perda de quase 30%. O armazenamento por congelamento a -80°C durante 4 semanas manteve a transparência do cristalino; a transmissão espectral medida imediatamente após o descongelamen to à temperatura ambiente coincidiu exatamente com a da lente extraída recentemente. Conclusão: A transparência do cristalino suíno é afetada pelo método de armazenamento. O espectro visível é o mais afetado, evidenciado pelo efeito sobre a transparência e consequentemente a quantidade de luz transmitida. Os resultados mostram que o congelamento a -80°C mantém a transparência do cristalino suíno por pelo menos 4 semanas.


Assuntos
Animais , Preservação de Órgãos/métodos , Cristalino/anatomia & histologia , Valores de Referência , Espectrofotometria/instrumentação , Espectrofotometria/métodos , Suínos , Fatores de Tempo , Raios Ultravioleta , Óleo de Rícino/química , Reprodutibilidade dos Testes , Modelos Animais , Formaldeído/química , Congelamento , Cristalino/fisiologia , Cristalino/diagnóstico por imagem , Luz
8.
Arq. bras. oftalmol ; 78(3): 146-149, May-Jun/2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-753019

RESUMO

ABSTRACT Purpose: To analyze ocular biometry parameters and evaluate their relationship with gestational age, birth weight, and postmenstrual age in prematurely born infants. Methods: The right eyes of 361 premature infants born before the 36th gestational week were evaluated. Birth weight, gestational week, and gender were recorded. An A-scan Biometer was used for obtaining axial measurements, including anterior chamber depth, lens thickness, vitreous length, and total axial length. Results: Gestational age and birth weight values ranged from 23 to 36 weeks and from 560 to 2,670 g, respectively. The mean gestational age and birth weight were 30.8 ± 2.8 weeks and 1,497.9 ± 483.6 g, respectively. During the first examination (4-5 weeks of postnatal age), birth weight and gestational age of the infants correlated significantly and positively with lens thickness, vitreous length, and axial length (r>0.5, p<0.001), but not with anterior chamber depth (r<0.5). Increased vitreous and axial lengths correlated significantly with increasing postmenstrual age of the infants (r=0.669, p<0.001; r=0.845, p<0.001, respectively). Conclusions: Lens thickness, vitreous length, and axial length, but not anterior chamber depth, were significantly correlated with birth weight and gestational age. All four parameters increased with increasing postmenstrual age, with higher correlations for vitreous and axial lengths than for anterior chamber depth and lens thickness. It was concluded that axial elongation resulted primarily from increasing posterior chamber length. .


RESUMO Objetivo: Medir os comprimentos axiais dos componentes oculares e avaliar a relação com a idade gestacional, peso ao nascer e idade pós-menstrual em crianças nascidas prematuramente. Método: O olho direito de 361 crianças prematuras, que nasceram com menos de 36 semanas de gestação, foram avaliados. O peso ao nascer, semanas de gestação e gênero foram registrados. Um biômetro A-scan foi utilizado para a obtenção das medidas axiais da profundidade da câmara anterior, espessura do cristalino, comprimento vítreo e comprimento axial total. Resultados: A idade gestacional e os valores de peso ao nascimento variaram de 23 a 36 semanas e de 560 a 2.670 g, respectivamente. A idade gestacional e o peso ao nascer foram 30,8 ± 2,8 semanas e 1.497,9 ± 483,6 g. Ao primeiro exame (4 a 5 semanas de idade pós-natal), o peso ao nascimento e a idade gestacional dos recém-nascidos apresentaram correlação positiva, estatisticamente significativa, com a espessura do cristalino, comprimento vítreo e comprimento axial total (r>0,5 p<0,001), mas não com a profundidade da câmara anterior (r<0,5). O alongamento de comprimento vítreo e do comprimento axial total se correlacionaram significativamente com o aumento da idade pós-menstrual dos lactentes (r=0,669; p<0,001 e r=0,845; p<0,001, respectivamente). Conclusões: A espessura do cristalino, o comprimento vítreo e o comprimento axial total, mas não profundidade da câmara anterior, foram significativamente correlacionados com o peso ao nascimento e com a idade gestacional. Todos os quatro componentes aumentaram com a idade pós-menstrual, apresentando correlações mais elevadas do comprimento vítreo e comprimento axial total do que da profundidade da câmara anterior e espessura do cristalino. Concluiu-se que o alongamento axial resultou principalmente do aumento do comprimento da câmara posterior. .


Assuntos
Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Gravidez , Peso ao Nascer/fisiologia , Idade Gestacional , Recém-Nascido Prematuro/crescimento & desenvolvimento , Retinopatia da Prematuridade/fisiopatologia , Fatores Etários , Câmara Anterior/anatomia & histologia , Comprimento Axial do Olho/fisiologia , Biometria , Estudos de Coortes , Seguimentos , Recém-Nascido de Baixo Peso/crescimento & desenvolvimento , Cristalino/anatomia & histologia , Fatores Sexuais , Corpo Vítreo/anatomia & histologia
9.
Rev. cuba. oftalmol ; 26(2): 191-197, mayo.-ago. 2013.
Artigo em Espanhol | LILACS | ID: lil-695029

RESUMO

Objetivo: determinar la dureza nuclear del cristalino clasificada por el Lens Opacities Classification System (LOCS III) y su relación con la densitometría del cristalino. Métodos: se realizó un estudio descriptivo, longitudinal y prospectivo en el Centro de Microcirugía Ocular del Instituto Cubano de Oftalmología Ramón Pando Ferrer, desde enero de 2011 hasta diciembre de 2011, en 290 pacientes diagnosticados con catarata y operados con la técnica de facoemulsificación por pre chop, más implante de lente intraocular. Resultados: los núcleos cristalineanos (N) clasificados del N1 al N6 aumentaron la densitometría del cristalino hasta un valor de 46,5 por ciento, con tiempo efectivo de facoemulsificación de 0,54 min relacionado a la dureza nuclear, al igual que las clasificadas de P2 a P5 donde la densitometría fue hasta 66,1 por ciento con valores de tiempo efectivo de facoemulsificación de 0,46 min. La edad media fue de 63,8 años de edad, se planificó una refracción esperada para -0,16 D, el equivalente esférico posoperatorio fue de 0,50 D y el astigmatismo medio inducido de -0,56 D. La mejor agudeza visual sin corrección mejoró a 0,81 en el posoperatorio y la corregida final fue de 0,96. Conclusiones: el estudio densitométrico del cristalino, como valor objetivo de su dureza, le permite al cirujano trazarse una estrategia quirúrgica adecuada en cada paciente para lograr una verdadera cirugía refractiva personalizada del cristalino y resultados visuales óptimos


Objective: To determine the nuclear hardness of the crystalline lens according to the Lens Opacities Classification System (LOCS III) and its relationship with the crystalline lens densitometry. Methods: A prospective, cross-sectional and descriptive study was conducted in 290 patients diagnosed with cataract and operated on by the prechop phacoemulsification technique plus intraocular lens implantation, at Ramon Pando Ferrer Cuban Institute of Ophthalmology from January to December, 2011. Results: The crystalline lens nuclei classified as N1 to N6 increased the lens crystalline densitometry up to 46.5 percent, with effective phacoemulsification time of 0.54min with respect to the .nucleus hardness; the densitometry value in the nuclei classified P2 to P5 rose to 66.1 percent where the effective phacoemulsification time was 0.46. The average patients' age was 63.8 years, the expected refraction was planned to be -0.16D, the postoperative spherical equivalent was 0.50 D and the mean induced astigmatism reached -0.56 D. The best uncorrected visual acuity improved by 0.81 in the postoperative period and the final corrected acuity was 0.96. Conclusions: The densitometric study of the crystalline lens, as concrete value of hardness, allows the surgeon to draw an adequate surgical strategy for each patient in order to make a real customized refractive surgery of the crystalline lens and to obtain the optimal visual results


Assuntos
Humanos , Masculino , Feminino , Cristalino/anatomia & histologia , Densitometria/métodos , Extração de Catarata/métodos , Facoemulsificação/métodos , Epidemiologia Descritiva , Estudos Longitudinais , Estudos Prospectivos
10.
Arch. Soc. Esp. Oftalmol ; 82(3): 141-146, mar. 2007. tab
Artigo em Espanhol | IBECS (Espanha) | ID: ibc-81408

RESUMO

Objetivo: Averiguar si la diabetes en pacientes sin catarata ni retinopatía diabética altera los valores densitométricos del cristalino y en qué medida esto se produce. Métodos: Se estudian 93 ojos pertenecientes a 47 pacientes, divididos en dos grupos: 53 ojos de 27 pacientes diabéticos tipo II con agudeza visual igual o superior a 0,8 y fondo de ojo normal y un grupo control de 40 ojos de 20 pacientes sanos con una media de edad semejante. A todos se les realiza una medida con cámara de Scheimpflug y se consignan la densidad cristaliniana de la cápsula anterior, el cortex anterior y el núcleo. Los valores obtenidos en los dos grupos se comparan mediante análisis de la varianza (ANOVA). Resultados: Todos los valores densitométricos fueron mayores en los pacientes diabéticos con respecto a los normales. La mayor diferencia se produce en los valores de la cápsula anterior, seguidos del núcleo y el cortex. Solo en el caso de la cápsula anterior los valores se acercan a la significación estadística (P=0,07). Conclusiones: La diabetes incrementa los valores densitométricos de la cápsula anterior y en menor medida del cortex anterior. No obstante son necesarios nuevos estudios para verificar si esta alteración se produce de forma significativa (AU)


Objective: To assess if diabetes, in patients without cataracts or diabetic retinopathy, alters the densitometric values of the lens and to what degree this occurs. Methods: A total of 93 patients, divided into two groups, were studied: the diabetic patients had a visual acuity equal to or greater than 0.8 and normal eye funduscopy, and the control group consisted of healthy patients of a similar age. Measurements in all patients were made with the Scheimpflug camera and the lens density of the anterior capsule, anterior cortex and nucleus was defined. The values obtained in the two groups were compared by analysis of variance (ANOVA). Results: All densitometric values were greater in the diabetic patients than in the normal controls. The greatest difference was seen in the values of the anterior capsule, followed by the nucleus and cortex. The differences approached statistical significance (P=0.07) only in the case of the anterior capsule. Conclusions: Diabetes increases densitometric values of the anterior capsule and to a lesser degree of the anterior cortex. However, further studies are necessary to verify if this alteration is of significance (AU)


Assuntos
Humanos , Diabetes Mellitus Tipo 2/complicações , Cristalino/anatomia & histologia , Catarata/diagnóstico , Estudos de Casos e Controles , Espectrometria gama , Densitometria