Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 12.171
Filtrar
Mais filtros

Coleção Fiocruz
Intervalo de ano de publicação
1.
N Engl J Med ; 388(12): 1092-1100, 2023 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-36947466

RESUMO

BACKGROUND: Coffee is one of the most commonly consumed beverages in the world, but the acute health effects of coffee consumption remain uncertain. METHODS: We conducted a prospective, randomized, case-crossover trial to examine the effects of caffeinated coffee on cardiac ectopy and arrhythmias, daily step counts, sleep minutes, and serum glucose levels. A total of 100 adults were fitted with a continuously recording electrocardiogram device, a wrist-worn accelerometer, and a continuous glucose monitor. Participants downloaded a smartphone application to collect geolocation data. We used daily text messages, sent over a period of 14 days, to randomly instruct participants to consume caffeinated coffee or avoid caffeine. The primary outcome was the mean number of daily premature atrial contractions. Adherence to the randomization assignment was assessed with the use of real-time indicators recorded by the participants, daily surveys, reimbursements for date-stamped receipts for coffee purchases, and virtual monitoring (geofencing) of coffee-shop visits. RESULTS: The mean (±SD) age of the participants was 39±13 years; 51% were women, and 51% were non-Hispanic White. Adherence to the random assignments was assessed to be high. The consumption of caffeinated coffee was associated with 58 daily premature atrial contractions as compared with 53 daily events on days when caffeine was avoided (rate ratio, 1.09; 95% confidence interval [CI], 0.98 to 1.20; P = 0.10). The consumption of caffeinated coffee as compared with no caffeine consumption was associated with 154 and 102 daily premature ventricular contractions, respectively (rate ratio, 1.51; 95% CI, 1.18 to 1.94); 10,646 and 9665 daily steps (mean difference, 1058; 95% CI, 441 to 1675); 397 and 432 minutes of nightly sleep (mean difference, 36; 95% CI, 25 to 47); and serum glucose levels of 95 mg per deciliter and 96 mg per deciliter (mean difference, -0.41; 95% CI, -5.42 to 4.60). CONCLUSIONS: In this randomized trial, the consumption of caffeinated coffee did not result in significantly more daily premature atrial contractions than the avoidance of caffeine. (Funded by the University of California, San Francisco, and the National Institutes of Health; CRAVE ClinicalTrials.gov number, NCT03671759.).


Assuntos
Complexos Atriais Prematuros , Glicemia , Cafeína , Café , Duração do Sono , Caminhada , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complexos Atriais Prematuros/induzido quimicamente , Complexos Atriais Prematuros/etiologia , Cafeína/efeitos adversos , Cafeína/farmacologia , Café/efeitos adversos , Glucose , Estudos Prospectivos , Ingestão de Líquidos , Estudos Cross-Over , Glicemia/análise , Duração do Sono/efeitos dos fármacos , Acelerometria , Eletrocardiografia Ambulatorial , Automonitorização da Glicemia , Aplicativos Móveis , Envio de Mensagens de Texto , Complexos Ventriculares Prematuros/induzido quimicamente , Complexos Ventriculares Prematuros/etiologia
2.
Circulation ; 150(6): 439-450, 2024 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-38973458

RESUMO

BACKGROUND: A dual-chamber leadless pacemaker system has been designed for atrioventricular synchronous pacing using wireless, beat-to-beat, implant-to-implant (i2i) communication between distinct atrial and ventricular leadless pacemakers. The atrioventricular synchrony achieved across various ambulatory scenarios has yet to be systematically evaluated. METHODS: A prospective, single-arm, unblinded, multicenter, international clinical trial of the leadless pacemaker system was conducted in patients with a conventional dual-chamber pacing indication enrolled from February 2022 to March 2023. Leadless pacemaker systems were implanted, and 12-lead Holter electrocardiographic recordings were collected 3 months after implantation over various postures/activities: sitting, supine, left lateral recumbent, right lateral recumbent, standing, normal walk, and fast walk. An independent Holter core laboratory performed a manual adjudication of the percent of atrioventricular synchronous beats using the standard 300-millisecond PR interval limit. Atrium-to-ventricle and ventricle-to-atrium i2i communication success rates were also assessed. Post hoc summary statistics describing the relationships between atrioventricular synchrony and i2i success, posture/activity, implantation indication, atrioventricular event, and heart rate were calculated. RESULTS: In the evaluable population (n=384 of 464 enrolled [83%]; 61% male; age, 70 years; weight, 82 kg; 60% ejection fraction; 95% of beats evaluable), the mean atrioventricular synchrony of 98% of beats observed across all postures using the standard 300-millisecond limit was greater than both atrial-to-ventricular i2i (94%) and ventricular-to-atrial i2i (94%; P<0.001), exceeding both i2i values in 95% of patients. Atrioventricular synchrony was achieved in >95% of evaluable beats across all postures/activities, implantation indications, atrioventricular paced/sensed event combinations, and heart rate ranges (including >100 bpm). CONCLUSIONS: This dual-chamber leadless pacemaker system demonstrated atrioventricular synchrony in 98% of evaluable beats at 3 months after implantation. Atrioventricular synchrony was maintained across postures/activities and remained robust for heart rates >100 bpm.


Assuntos
Marca-Passo Artificial , Humanos , Masculino , Feminino , Idoso , Estudos Prospectivos , Idoso de 80 Anos ou mais , Frequência Cardíaca , Eletrocardiografia Ambulatorial , Pessoa de Meia-Idade , Estimulação Cardíaca Artificial/métodos
3.
Eur Heart J ; 45(14): 1255-1265, 2024 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-38445836

RESUMO

BACKGROUND AND AIMS: Available data on continuous rhythm monitoring by implantable loop recorders (ILRs) in patients with Brugada syndrome (BrS) are scarce. The aim of this multi-centre study was to evaluate the diagnostic yield and clinical implication of a continuous rhythm monitoring strategy by ILRs in a large cohort of BrS patients and to assess the precise arrhythmic cause of syncopal episodes. METHODS: A total of 370 patients with BrS and ILRs (mean age 43.5 ± 15.9, 33.8% female, 74.1% symptomatic) from 18 international centers were included. Patients were followed with continuous rhythm monitoring for a median follow-up of 3 years. RESULTS: During follow-up, an arrhythmic event was recorded in 30.7% of symptomatic patients [18.6% atrial arrhythmias (AAs), 10.2% bradyarrhythmias (BAs), and 7.3% ventricular arrhythmias (VAs)]. In patients with recurrent syncope, the aetiology was arrhythmic in 22.4% (59.3% BAs, 25.0% VAs, and 15.6% AAs). The ILR led to drug therapy initiation in 11.4%, ablation procedure in 10.9%, implantation of a pacemaker in 2.5%, and a cardioverter-defibrillator in 8%. At multivariate analysis, the presence of symptoms [hazard ratio (HR) 2.5, P = .001] and age >50 years (HR 1.7, P = .016) were independent predictors of arrhythmic events, while inducibility of ventricular fibrillation at the electrophysiological study (HR 9.0, P < .001) was a predictor of VAs. CONCLUSIONS: ILR detects arrhythmic events in nearly 30% of symptomatic BrS patients, leading to appropriate therapy in 70% of them. The most commonly detected arrhythmias are AAs and BAs, while VAs are detected only in 7% of cases. Symptom status can be used to guide ILR implantation.


Assuntos
Síndrome de Brugada , Desfibriladores Implantáveis , Marca-Passo Artificial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Arritmias Cardíacas/complicações , Arritmias Cardíacas/diagnóstico , Síndrome de Brugada/complicações , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/terapia , Eletrocardiografia/métodos , Eletrocardiografia Ambulatorial/métodos , Adulto
4.
Eur Heart J ; 45(29): 2604-2616, 2024 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-38759110

RESUMO

BACKGROUND AND AIMS: Patterns of atrial fibrillation (AF) recurrence post-catheter ablation for persistent AF (PsAF) are not well described. This study aimed to describe the pattern of AF recurrence seen following catheter ablation for PsAF and the implications for healthcare utilization and quality of life (QoL). METHODS: This was a post-hoc analysis of the CAPLA study, an international, multicentre study that randomized patients with symptomatic PsAF to pulmonary vein isolation plus posterior wall isolation or pulmonary vein isolation alone. Patients underwent twice daily single lead ECG, implantable device monitoring or three monthly Holter monitoring. RESULTS: 154 of 333 (46.2%) patients (median age 67.3 years, 28% female) experienced AF recurrence at 12-month follow-up. Recurrence was paroxysmal in 97 (63%) patients and persistent in 57 (37%). Recurrence type did not differ between randomization groups (P = .508). Median AF burden was 27.4% in PsAF recurrence and .9% in paroxysmal AF (PAF) recurrence (P < .001). Patients with PsAF recurrence had lower baseline left ventricular ejection fraction (PsAF 50% vs. PAF 60%, P < .001) and larger left atrial volume (PsAF 54.2 ± 19.3 mL/m² vs. PAF 44.8 ± 11.6 mL/m², P = .008). Healthcare utilization was significantly higher in PsAF (45 patients [78.9%]) vs. PAF recurrence (45 patients [46.4%], P < .001) and lowest in those without recurrence (17 patients [9.5%], P < .001). Patients without AF recurrence had greater improvements in QoL as assessed by the Atrial Fibrillation Effect on Quality-of-Life (AFEQT) questionnaire (Δ33.3 ± 25.2 points) compared to those with PAF (Δ24.0 ± 25.0 points, P = .012) or PsAF (Δ13.4 ± 22.9 points, P < .001) recurrence. CONCLUSIONS: AF recurrence is more often paroxysmal after catheter ablation for PsAF irrespective of ablation strategy. Recurrent PsAF was associated with higher AF burden, increased healthcare utilization and antiarrhythmic drug use. The type of AF recurrence and AF burden may be considered important endpoints in clinical trials investigating ablation of PsAF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Qualidade de Vida , Recidiva , Humanos , Fibrilação Atrial/cirurgia , Feminino , Masculino , Ablação por Cateter/métodos , Idoso , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Eletrocardiografia Ambulatorial , Aceitação pelo Paciente de Cuidados de Saúde/estatística & dados numéricos , Resultado do Tratamento
5.
Stroke ; 55(4): 946-953, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38436115

RESUMO

BACKGROUND: Covert atrial fibrillation (AF) is a major cause of cryptogenic stroke. This study investigated whether a dose-dependent relationship exists between the frequency of premature atrial contractions (PACs) and AF detection in patients with cryptogenic stroke using an insertable cardiac monitor (ICM). METHODS: We enrolled consecutive patients with cryptogenic stroke who underwent ICM implantation between October 2016 and September 2020 at 8 stroke centers in Japan. Patients were divided into 3 groups according to the PAC count on 24-hour Holter ECG: ≤200 (group L), >200 to ≤500 (group M), and >500 (group H). We defined a high AF burden as above the median of the cumulative duration of AF episodes during the entire monitoring period. We evaluated the association of the frequency of PACs with AF detection using log-rank trend test and Cox proportional hazard model and with high AF burden using logistic regression model, adjusting for age, sex, CHADS2 score. RESULTS: Of 417 patients, we analyzed 381 patients with Holter ECG and ICM data. The median age was 70 (interquartile range, 59.5-76.5), 246 patients (65%) were males, and the median duration of ICM recording was 605 days (interquartile range, 397-827 days). The rate of new AF detected by ICM was higher in groups with more frequent PAC (15.5%/y in group L [n=277] versus 44.0%/y in group M [n=42] versus 71.4%/y in group H [n=62]; log-rank trend P<0.01). Compared with group L, the adjusted hazard ratios for AF detection in groups M and H were 2.11 (95% CI, 1.24-3.58) and 3.23 (95% CI, 2.07-5.04), respectively, and the adjusted odds ratio for high AF burden in groups M and H were 2.57 (95% CI, 1.14-5.74) and 4.25 (2.14-8.47), respectively. CONCLUSIONS: The frequency of PACs was dose-dependently associated with AF detection in patients with cryptogenic stroke.


Assuntos
Fibrilação Atrial , Complexos Atriais Prematuros , AVC Isquêmico , Acidente Vascular Cerebral , Masculino , Humanos , Idoso , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/complicações , Complexos Atriais Prematuros/diagnóstico , Complexos Atriais Prematuros/epidemiologia , Complexos Atriais Prematuros/complicações , Acidente Vascular Cerebral/diagnóstico , AVC Isquêmico/complicações , Eletrocardiografia Ambulatorial
6.
Pflugers Arch ; 476(7): 1145-1154, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38703193

RESUMO

Arrhythmia detection is essential when assessing the safety of novel drugs and therapies in preclinical studies. Many short-term arrhythmia monitoring methods exist, including non-invasive ECG and Holter. However, there are no reliable, long-term, non-invasive, or minimally invasive methods for cardiac arrhythmia follow-up in large animals that allows free movement with littermates. A long follow-up time is needed when estimating the impact of long-lasting drugs or therapies, such as gene therapy. We evaluated the feasibility and performance of insertable cardiac monitors (ICMs) in pigs for minimally invasive, long-term monitoring of cardiac arrhythmias that allows free movement and species-specific behavior. Multiple implantation sites were tested to assess signal quality. ICMs recognized reliably many different arrhythmias but failed to detect single extrasystoles. They also over-diagnosed T-waves, resulting in oversensing. Muscle activity and natural startles of the animals caused noise, leading to a heterogeneous signal requiring post-recording evaluation. In spite of these shortcomings, the ICMs showed to be very useful for minimally invasive long-term monitoring of cardiac rhythm in pigs.


Assuntos
Arritmias Cardíacas , Animais , Suínos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Eletrocardiografia Ambulatorial/instrumentação , Eletrocardiografia Ambulatorial/métodos , Eletrocardiografia/métodos , Eletrocardiografia/instrumentação , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Monitorização Fisiológica/veterinária
7.
Am Heart J ; 269: 25-34, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38072334

RESUMO

BACKGROUND: Objective data comparing the diagnostic performance of different ambulatory cardiac monitors (ACMs) are lacking. OBJECTIVES: To assess variation in monitoring strategy, clinical outcomes and healthcare utilization in patients undergoing ambulatory monitoring without a pre-existing arrhythmia diagnosis. METHODS: Using the full sample (100%) of Medicare claims data, we performed a retrospective cohort study of diagnostic-naïve patients who received first-time ACM in 2017 to 2018 and evaluated arrhythmia encounter diagnosis at 3-months, repeat ACM testing at 6 months, all-cause 90-day emergency department (ED) and inpatient utilization, and cost of different strategies: Holter; long-term continuous monitor (LTCM); non-continuous, event-based external ambulatory event monitor (AEM); and mobile cardiac telemetry (MCT). We secondarily performed a device-specific analysis by manufacturer, identified from unique claim modifier codes. RESULTS: ACMs were used in 287,789 patients (AEM = 10.3%; Holter = 53.8%; LTCM = 13.3%; MCT = 22.5%). Device-specific analysis showed that compared to Holter, AEM, MCT, or other LTCM manufacturers, a specific LTCM (ZioⓇ XT 14-day patch, iRhythm Technologies, San Francisco, CA) had the highest adjusted odds of diagnosis and lowest adjusted odds of ACM retesting. Findings were consistent for specific arrhythmia diagnoses of ventricular tachycardia, atrioventricular block, and paroxysmal atrial fibrillation. As a category, LTCM was associated with the lowest 1-year incremental health care expenditures (mean Δ$10,159), followed by Holter ($10,755), AEM ($11,462), and MCT ($12,532). CONCLUSIONS: There was large variation in diagnostic monitoring strategy. A specific LTCM was associated with the highest adjusted odds of a new arrhythmia diagnosis and lowest adjusted odds of repeat ACM testing. LTCM as a category had the lowest incremental acute care utilization. Different monitoring strategies may produce different results with respect to diagnosis and care.


Assuntos
Fibrilação Atrial , Eletrocardiografia Ambulatorial , Metacrilatos , Estados Unidos , Humanos , Idoso , Estudos Retrospectivos , Medicare , Fibrilação Atrial/diagnóstico , Gastos em Saúde , Aceitação pelo Paciente de Cuidados de Saúde
8.
J Cardiovasc Electrophysiol ; 35(7): 1506-1510, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38736203

RESUMO

INTRODUCTION: Implantable permanent pacemaker function is supported by their energy sources for a mean period of 8.8-12.4 years. We previously published this case of a patient with a normally functioning VVI pacemaker, 31 years after implantation. METHODS AND RESULTS: In this report, we state that the device is still functioning normally 40 years after implantation. The most recent device interrogation revealed pacing threshold of 0.9 V/0.5 ms. Holter monitoring for 24 hours recorded a total of 98.707 beats with 97.78% paced beats, without any indication of pacemaker malfunction and with stable heart rate at 70-71 bpm. CONCLUSION: Most patients with implantable devices have the appropriate follow-up and settings of low energy consumption. Manufacturing companies should focus on prolonging device longevity, to produce future devices with higher energy capacity.


Assuntos
Eletrocardiografia Ambulatorial , Frequência Cardíaca , Marca-Passo Artificial , Humanos , Eletrocardiografia Ambulatorial/instrumentação , Fatores de Tempo , Estimulação Cardíaca Artificial , Masculino , Desenho de Equipamento , Idoso , Feminino
9.
J Cardiovasc Electrophysiol ; 35(2): 341-345, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38164063

RESUMO

INTRODUCTION: The increasing use of insertable cardiac monitors (ICMs) for long-term continuous arrhythmia monitoring creates a high volume of transmissions and a significant workload for clinics. The ability to remotely reprogram device alert settings without in-office patient visits was recently introduced, but its impact on clinic workflow compared to the previous ICM iteration is unknown. METHODS: The aim of this real-world study was to evaluate the impact of device reprogramming capabilities on ICM alert burden and on clinic workflow. Deidentified data was obtained from US patients and a total of 19 525 receiving a LINQ II were propensity score-matched with 19 525 implanted with LINQ TruRhythm (TR) ICM based on age and reason for monitoring. RESULTS: After reprogramming, ICM alerts reduced by 20.5% (p < .001). Compared with patients monitored with LINQ TR, patients with LINQ II had their device reprogrammed sooner after implant and more frequently during follow-up. Adoption of remote programming was projected to lead to an annual total clinic time savings of 211 h per 100 ICM patients managed. CONCLUSION: These data suggest that utilization of ICM alert reprogramming has increased with remote capabilities, which may reduce clinic and patient burden for ICM follow-up and free clinician time for other valuable patient care activities.


Assuntos
Arritmias Cardíacas , Eletrocardiografia Ambulatorial , Humanos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Doença do Sistema de Condução Cardíaco
10.
J Cardiovasc Electrophysiol ; 35(10): 2017-2028, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39161177

RESUMO

INTRODUCTION: Strategies beyond pulmonary vein isolation (PVI) in persistent atrial fibrillation (persAF) are debated. A novel mapping tool provides algorithmic detection of ablation targets based on electrogram (EGM) properties specific to stable localized rotational activations. METHODS: The mapping tool was used on 31 patients (20 de novo). The algorithm was used to optimize PVI line placement and guide additional ablations. Targets were detected by calculating local cycle length (L-CL) and local spread of activation within that L-CL (Duty Cycle; DC) for EGMs with consistent morphology and activation. At least two left atrial (LA) maps (pre-PVI and post-PVI) were acquired in atrial fibrillation (AF) in all patients (except those with AF termination during PVI). Extra-pulmonary vein (PV) targets were compared between the two LA maps in each patient. Follow-up included Holter monitoring every 3 months. RESULTS: Patients had a median of 3 extra-PV drivers/targets. The majority (81%) were localized in the same areas between the two LA maps. All patients had progressive AF organization demonstrated by global activation slowing: histogram peak L-CL increased from 162 to 171 ms (post-PVI; p = .0003) than to 175 ms (posttarget ablation; p = .04). Moreover, L-CL dispersion was reduced by ablation; in 50% their values tended to cluster around two dominant cycles. In de novo patients AF terminated to sinus rhythm or atrial tachycardia (AT) within 48 h postprocedure in 88% of cases, and at 18 months mean follow-up recurrence occurred in only five (25%) patients (three persAF, two AT). There were no complications. CONCLUSION: The algorithmic detection of EGMs consistent with localized reentry during sequential mapping of persAF provided reproducible targets for ablation. This allowed personalized PVI and limited, highly-selective, extra-PV ablation. Results of this initial experience included progressive organization of AF with ablation and a low recurrence rate after a single procedure.


Assuntos
Algoritmos , Fibrilação Atrial , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Ablação por Cateter/efeitos adversos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Resultado do Tratamento , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Potenciais de Ação , Valor Preditivo dos Testes , Eletrocardiografia Ambulatorial , Fatores de Tempo , Frequência Cardíaca , Recidiva , Automação
11.
J Cardiovasc Electrophysiol ; 35(7): 1393-1400, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38741382

RESUMO

INTRODUCTION: Inappropriate sinus tachycardia (IST) is a common condition with frequently not tolerated beta-blockers or ivabradine and a high rate of complication in ablation strategy; we describe an alternative anatomical approach of sinus node (SN) modulation. METHODS: This retrospective study describes a case series of 6 patients from two centers diagnosed with symptomatic IST undergoing SN ablation. RESULTS: The mean age was 40.6 ± 13.9 years; five of the six patients were female, 100% of patients reported heart palpitations, and 66% reported dizziness, the average heart rate (HR) on a 24-h Holter was 93.2 ± 7.9 bpm. HR during the first stage of a stress test using a standard Bruce protocol was 150 ± 70 bpm, The average HR on 24-h Holter postablation was 75 ± 5.6 bpm, the sinus rate HR during stage 1 of a Bruce protocol exercise stress test was 120 ± 10 bpm. CONCLUSION: This is the first case series reporting the acute and long-term results of a novel anatomical approach for SN modulation to treat IST targeting the arcuate ridge (AR) under intracardiac echography (ICE) guidance. The novel anatomic ICE-guided catheter ablation approach aimed to identify the earliest activation at the AR with an extension of RF lesions toward its septal region seems effective and safe to modulate the SN in symptomatic patients with IST refractory to medical treatment.


Assuntos
Ablação por Cateter , Frequência Cardíaca , Taquicardia Sinusal , Humanos , Feminino , Taquicardia Sinusal/cirurgia , Taquicardia Sinusal/fisiopatologia , Estudos Retrospectivos , Masculino , Pessoa de Meia-Idade , Adulto , Resultado do Tratamento , Potenciais de Ação , Valor Preditivo dos Testes , Antiarrítmicos/uso terapêutico , Fatores de Tempo , Ultrassonografia de Intervenção , Eletrocardiografia Ambulatorial , Resistência a Medicamentos , Nó Sinoatrial/cirurgia , Nó Sinoatrial/fisiopatologia , Ecocardiografia
12.
J Cardiovasc Electrophysiol ; 35(10): 1941-1951, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39082327

RESUMO

INTRODUCTION: Early-onset atrial fibrillation (AF) has already been observed in approximately 2% of patients with genetically proven long QT syndrome (LQTS). This frequency is higher than population-based estimates of early-onset AF. However, the concomitant expression of AF in LQTS is likely underestimated. The purpose of this study was to examine the clinical presentation, genetic background, and outcomes of a cohort of patients with LQTS and early-onset AF referred to a single tertiary center. METHODS: Twenty-seven patients diagnosed with congenital LQTS were included in the study based on the documentation of early-onset (age ≤50 years) clinical or subclinical AF episodes in all available medical records, including standard electrocardiograms, wearable monitor or cardiac implantable electronic devices. RESULTS: Seventeen patients experienced clinical AF during the follow-up period. Subclinical AF was detected in 10 patients through insertable or wearable cardiac monitors. In our series, the mean heart rate during AF episodes was found to be relatively low despite the patients' young age and the low or minimal effective doses of beta-blockers used for QTc interval control. All patients exhibiting LQTS and early-onset AF were genotype positive, carrying mutations in the KCNQ1 (66%), KCNH2, KCNE1, and SCN5A genes. Notably, most of these patients carried the same p.(R231C) mutation in the KCNQ1 gene (59%) and were from the same families, suggesting concurrent expression of familial AF and LQTS. CONCLUSION: LQTS patients are prone to developing clinical and subclinical AF, even at a younger age. The occurrence of early-onset AF in the LQTS population could be more frequent than previously assumed. AF should be considered as a potential dysrhythmia related to LQTS. Our study emphasizes the importance of carefully researching clinical and/or subclinical episodes of AF through strict heart rhythm monitoring in the LQTS population.


Assuntos
Idade de Início , Fibrilação Atrial , Canal de Potássio ERG1 , Predisposição Genética para Doença , Frequência Cardíaca , Síndrome do QT Longo , Mutação , Canal de Sódio Disparado por Voltagem NAV1.5 , Fenótipo , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/genética , Masculino , Feminino , Síndrome do QT Longo/genética , Síndrome do QT Longo/fisiopatologia , Síndrome do QT Longo/diagnóstico , Pessoa de Meia-Idade , Adulto , Adulto Jovem , Canal de Sódio Disparado por Voltagem NAV1.5/genética , Canal de Potássio ERG1/genética , Potenciais de Ação , Canal de Potássio KCNQ1/genética , Fatores de Risco , Adolescente , Estudos Retrospectivos , Fatores de Tempo , Eletrocardiografia Ambulatorial/instrumentação , Criança , Canais de Potássio de Abertura Dependente da Tensão da Membrana/genética
13.
J Cardiovasc Electrophysiol ; 35(8): 1688-1690, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38845147

RESUMO

INTRODUCTION: Prior studies have indicated that the frequency of premature ventricular complexes (PVC) increases after catheter ablation for atrial fibrillation (AF). However, these studies have primarily focused on patients whose PVC burden increased rather than including the full spectrum of outcomes. METHODS AND RESULTS: We performed a single-center retrospective cohort study of consecutive patients who underwent first-time AF ablation from 1/2018 to 12/2022 for paroxysmal or persistent AF and had both preablation and postablation rhythm monitoring within 6 months of the procedure. Patients were excluded if they had prior AF or PVC ablation or were prescribed a class I or III antiarrhythmic medication. Among 2945 patients who underwent AF ablation during the study period, 130 patients underwent first-time AF ablation and received both pre and post ambulatory monitoring. The median PVC burden before ablation was <1%. Most patients (63%) had no change in PVC burden after AF ablation compared with preablation, and patients who had an increase in PVC burden were offset by those with reductions in PVCs. A paired analysis pre- and post-AF ablation showed no significant change in PVC burden (p = .495). CONCLUSION: Although an elevated PVC burden after AF ablation may be seen clinically, the majority of patients have no change in burden. Studies that suggest an increase in PVC burden after AF ablation may suffer from incomplete sample selection and thus omit the important effect of regression to the mean.


Assuntos
Potenciais de Ação , Fibrilação Atrial , Ablação por Cateter , Frequência Cardíaca , Complexos Ventriculares Prematuros , Humanos , Complexos Ventriculares Prematuros/cirurgia , Complexos Ventriculares Prematuros/fisiopatologia , Complexos Ventriculares Prematuros/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Ablação por Cateter/efeitos adversos , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Resultado do Tratamento , Idoso , Fatores de Tempo , Fatores de Risco , Eletrocardiografia Ambulatorial
14.
Cardiovasc Diabetol ; 23(1): 295, 2024 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-39127733

RESUMO

BACKGROUND: A compromised cardiac autonomic function has been found in subjects with insulin resistance related disorders such as obesity, impaired glucose tolerance (IGT) and type 2 diabetes and confers an increased risk of adverse cardiovascular outcomes. Growing evidence indicate that 1 h plasma glucose levels (1hPG) during an oral glucose tolerance test (OGTT) ≥ 155 mg/dl identify amongst subjects with normal glucose tolerance (NGT) a new category of prediabetes (NGT 1 h-high), harboring an increased risk of cardiovascular organ damage. In this study we explored the relationship between 1 h post-load hyperglycemia and cardiac autonomic dysfunction. METHODS: Presence of cardiac autonomic neuropathy (CAN) defined by cardiovascular autonomic reflex tests (CARTs) and heart rate variability (HRV), assessed by 24-h electrocardiography were evaluated in 88 non-diabetic subjects subdivided on the basis of OGTT data in: NGT with 1 h PG < 155 mg/dl (NGT 1 h-low), NGT 1 h-high and IGT. RESULTS: As compared to subjects with NGT 1 h-low, those with NGT 1 h-high and IGT were more likely to have CARTs defined CAN and reduced values of the 24 h time domain HVR parameters including standard deviation of all normal heart cycles (SDNN), standard deviation of the average RR interval for each 5 min segment (SDANN), square root of the differences between adjacent RR intervals (RMSSD), percentage of beats with a consecutive RR interval difference > 50 ms (PNN50) and Triangular index. Univariate analyses showed that 1hPG, but not fasting and 2hPG, was inversely associated with all the explored HVR parameters and positively with CARTs determined presence of CAN. In multivariate regression analysis models including several confounders we found that 1hPG was an independent contributor of HRV and presence of CAN. CONCLUSION: Subjects with 1hPG ≥ 155 mg/dl have an impaired cardiac autonomic function.


Assuntos
Sistema Nervoso Autônomo , Glicemia , Teste de Tolerância a Glucose , Frequência Cardíaca , Hiperglicemia , Humanos , Estudos Transversais , Masculino , Feminino , Pessoa de Meia-Idade , Sistema Nervoso Autônomo/fisiopatologia , Glicemia/metabolismo , Hiperglicemia/fisiopatologia , Hiperglicemia/sangue , Hiperglicemia/diagnóstico , Adulto , Fatores de Tempo , Biomarcadores/sangue , Doenças do Sistema Nervoso Autônomo/fisiopatologia , Doenças do Sistema Nervoso Autônomo/diagnóstico , Doenças do Sistema Nervoso Autônomo/sangue , Coração/inervação , Coração/fisiopatologia , Eletrocardiografia Ambulatorial , Estado Pré-Diabético/fisiopatologia , Estado Pré-Diabético/diagnóstico , Estado Pré-Diabético/sangue , Intolerância à Glucose/diagnóstico , Intolerância à Glucose/fisiopatologia , Intolerância à Glucose/sangue , Fatores de Risco
15.
Cardiovasc Diabetol ; 23(1): 353, 2024 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-39342197

RESUMO

BACKGROUND: Type 2 diabetes mellitus (T2DM) is associated with decreased heart rate variability (HRV) with an unclear intermediate mechanism. This study aimed to conduct mediation analysis to explore the impact of various adipose tissues on the relationship between T2DM and HRV. METHODS: A total of 380 participants were enrolled for analysis, including 249 patients with T2DM and 131 non-diabetic controls. The thicknesses of four adipose tissues (subcutaneous, extraperitoneal, intraperitoneal, and epicardial) were measured by abdominal ultrasound or echocardiography respectively. HRV was assessed by 24-hour Holter for monitoring both frequency domain indices (LF, HF, and LF/HF) and time domain indices (SDNN, SDANN, SDNN index, rMSSD and pNN50). Mediation analysis was used toexamine whether adipose tissues mediated the relationship between T2DM and each index of HRV. Then, a latent variable - HRV burden - was constructed by structural equation model with selected HRV indices to comprehensively assess the whole HRV. RESULTS: Compared to non-diabetic controls, patients with T2DM exhibited a significant reduction in indices of HRV, and a remarkable increase in the thicknesses of extraperitoneal, intraperitoneal, and epicardial adipose tissues. Mediation analysis found significant indirect effects of T2DM on six indices of HRV, including HF, SDNN, SDANN, SDNN index, rMSSD, and pNN50, which was mediated by epicardial adipose tissue rather than other adipose tissues, with the mediation proportions of 64.21%, 16.38%, 68.33%, 24.34%, 24.10% and 30.51%, respectively. Additionally, epicardial adipose tissue partially mediated the relationship between T2DM and reduced HRV burden (24.26%), which composed by SDNN, SDNN index, rMSSD, and pNN50. CONCLUSION: Epicardial adipose tissue partially mediated the relationship between T2DM and reduced HRV, which reinforces the value of targeting heart-specific visceral fat to prevent cardiac autonomic neuropathy in diabetes.


Assuntos
Adiposidade , Diabetes Mellitus Tipo 2 , Frequência Cardíaca , Humanos , Diabetes Mellitus Tipo 2/fisiopatologia , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/epidemiologia , Feminino , Masculino , Pessoa de Meia-Idade , Estudos de Casos e Controles , Idoso , Análise de Mediação , Eletrocardiografia Ambulatorial , Fatores de Risco , Adulto , Fatores de Tempo , Estudos Transversais , Tecido Adiposo/fisiopatologia , Tecido Adiposo/diagnóstico por imagem , Medição de Risco , Sistema Nervoso Autônomo/fisiopatologia , Gordura Intra-Abdominal/fisiopatologia , Gordura Intra-Abdominal/diagnóstico por imagem
16.
Eur Radiol ; 34(1): 155-164, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37555957

RESUMO

OBJECTIVES: To investigate the feasibility of breast MRI exams and guided biopsies in patients with an implantable loop recorder (ILR) as well as the impact ILRs may have on image interpretation. MATERIALS AND METHODS: This retrospective study examined breast MRIs of patients with ILR, from April 2008 to September 2022. Radiological reports and electronic medical records were reviewed for demographic characteristics, safety concerns, and imaging findings. MR images were analyzed and compared statistically for artifact quantification on the various pulse sequences. RESULTS: Overall, 40/82,778 (0.049%) MRIs during the study period included ILR. All MRIs were completed without early termination. No patient-related or device-related adverse events occurred. ILRs were most commonly located in the left lower-inner quadrant (64.6%). The main artifact was a signal intensity (SI) void in a dipole formation in the ILR bed with or without areas of peripheral high SI. Artifacts appeared greatest in the cranio-caudal axis (p < 0.001), followed by the anterior-posterior axis (p < 0.001), and then the right-left axis. High peripheral rim-like SI artifacts appeared on the post-contrast and subtracted T1-weighted images, mimicking suspicious enhancement. Artifacts were most prominent on diffusion-weighted (p < 0.001), followed by T2-weighted and T1-weighted images. In eight patients, suspicious findings were found on MRI, resulting in four additional malignant lesions. Of six patients with left breast cancer, the tumor was completely visible in five cases and partially obscured in one. CONCLUSION: Breast MRI is feasible and safe among patients with ILR and may provide a significant diagnostic value, albeit with localized, characteristic artifacts. CLINICAL RELEVANCE STATEMENT: Indicated breast MRI exams and guided biopsies can be safely performed in patients with implantable loop recorder. Nevertheless, radiologists should be aware of associated limitations including limited assessment of the inner left breast and pseudo-enhancement artifacts. KEY POINTS: • Breast MRI in patients with an implantable loop recorder is an infrequent, feasible, and safe procedure. • Despite limited breast visualization of the implantable loop recorder bed and characteristic artifacts, MRI depicted additional lesions in 8/40 (20%) of cases, half of which were malignant. • Breast MRI in patients with an implantable loop recorder should be performed when indicated, taking into consideration typical associated artifacts.


Assuntos
Eletrocardiografia Ambulatorial , Imageamento por Ressonância Magnética , Humanos , Estudos Retrospectivos , Eletrocardiografia Ambulatorial/métodos , Imageamento por Ressonância Magnética/métodos , Próteses e Implantes , Radiografia
17.
BMC Neurol ; 24(1): 120, 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38605308

RESUMO

BACKGROUND: Atrial fibrillation (AF) screening after ischemic stroke or transient ischemic attack (TIA) is given high priority in clinical guidelines. However, patient selection, electrocardiogram (ECG) modality and screening duration remains undecided and current recommendations vary. METHODS: The aim of this study was to investigate the clinical practice of AF screening after ischemic stroke or TIA at Swedish stroke units. In collaboration with the stakeholders of the Swedish Stroke Register (Riksstroke) a digital survey was drafted, then tested and revised by three stroke consultants. The survey consisted of 17 multiple choice/ free text questions and was sent by e-mail to the medical directors at all stroke units in Sweden. RESULTS: All 72 stroke units in Sweden responded to the survey. Most stroke units reported that ≥ 75% of ischemic stroke (69/72 stroke units) or TIA patients (67/72 stroke units), without previously known AF, were screened for AF. Inpatient telemetry ECG was the method of first-choice in 81% of the units, but 7% reported lack of access. A variety of standard monitoring durations were used for inpatient telemetry ECG. The second most common choice was Holter ECG (17%), also with considerable variations in monitoring duration. Other AF screening modalities were used as a first-choice method (handheld and patch ECG) but less frequently. CONCLUSIONS: Clinical practice for AF screening after ischemic stroke or TIA differed between Swedish stroke units, both in choice of AF screening methods as well as in monitoring durations. There is an urgent need for evidence and evidence-based recommendations in this field. TRIAL REGISTRATION: Not applicable.


Assuntos
Fibrilação Atrial , Ataque Isquêmico Transitório , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Ataque Isquêmico Transitório/complicações , Ataque Isquêmico Transitório/diagnóstico , Ataque Isquêmico Transitório/epidemiologia , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Suécia/epidemiologia , Eletrocardiografia Ambulatorial , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia
18.
Europace ; 26(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38466042

RESUMO

AIMS: Premature ventricular contractions (PVC) and non-sustained ventricular tachycardia (NSVT) are commonly observed in light chain cardiac amyloidosis (AL-CA), but their association with prognosis is still unclear. We aimed to evaluate the prognostic value of PVCs and NSVT in patients with moderate-to-advanced AL-CA. METHODS AND RESULTS: We retrospectively included patients with AL-CA at modified 2004 Mayo stages II-IIIb between February 2014 and December 2020. Twenty-four-hour Holter recordings were assessed on admission. The outcomes included (i) new onset of adverse ventricular arrhythmia (VA) or sudden cardiac death (SCD) and (ii) cardiac death during follow-up. Of the 143 patients studied (60.41 ± 11.06 years, male 64.34%), 132 (92.31%) had presence of PVC, and 50 (34.97%) had NSVT on Holter. Twelve (8.4%) patients died in hospital and 131 patients were followed up (median 24.4 months), among whom 71 patients had cardiac death, and 15 underwent adverse VA/SCD. NSVT [hazard ratio (HR): 13.57, 95% confidence interval (CI): 3.06-60.18, P < 0.001], log-transformed PVC counts (HR: 1.46, 95%CI: 1.15-1.86, P = 0.002) and PVC burden (HR: 1.43 95%CI:1.14-1.80, P = 0.002) were predictive of new onset of adverse VA/SCD. The highest tertile of PVC counts (HR: 2.33, 95%CI: 1.27-4.28, P = 0.006) and PVC burden (HR: 2.58, 95%CI: 1.42-4.69, P = 0.002), rather than NSVT (HR: 1.16, 95%CI: 0.67-1.98, P = 0.603), was associated with cardiac death. Higher PVC counts/burden provided incremental value on modified 2004 Mayo stage in predicting cardiac death, with C index increasing from 0.681 to 0.712 and 0.717, respectively (P values <0.05). CONCLUSION: PVC count, burden, and NSVT significantly correlated with adverse VA/SCD during follow-up in patients with AL-CA. Higher PVC counts/burdens added incremental value for predicting cardiac death.


Assuntos
Taquicardia Ventricular , Complexos Ventriculares Prematuros , Humanos , Masculino , Prognóstico , Estudos Retrospectivos , Eletrocardiografia Ambulatorial , Morte Súbita Cardíaca
19.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38584469

RESUMO

AIMS: Brugada syndrome (BrS) diagnosis and risk stratification rely on the presence of a spontaneous type 1 (spT1) electrocardiogram (ECG) pattern; however, its spontaneous fluctuations may lead to misdiagnosis and risk underestimation. This study aims to assess the role for repeat high precordial lead (HPL) resting and ambulatory ECG monitoring in identifying a spT1, and evaluate its prognostic role. METHODS AND RESULTS: HPL resting and ambulatory monitoring ECGs of BrS subjects were reviewed retrospectively, and the presence of a spT1 associated with ventricular dysrhythmias and sudden cardiac death (SCD). Three-hundred and fifty-eight subjects (77 with spT1 pattern at presentation, Group 1, and 281 without, Group 2) were included. In total, 1651 resting HPL resting and 621 ambulatory monitoring ECGs were available for review, or adequately described. Over a median follow-up of 72 months (interquartile range - IQR - 75), 42/77 (55%) subjects in Group 1 showed a spT1 in at least one ECG. In Group 2, 36/281 subjects (13%) had a newly detected spT1 (1.9 per 100 person-year) and 23 on an HPL ambulatory recording (8%). Seven previously asymptomatic subjects, five of whom had a spT1 (four at presentation and one at follow-up), experienced arrhythmic events; survival analysis indicated that a spT1, either at presentation or during lifetime, was associated with events. Univariate models showed that a spT1 was consistently associated with increased risk [spT1 at presentation: hazard ratio (HR) 6.3, 95% confidence interval (CI) 1.4-28, P = 0.016; spT1 at follow-up: HR 3.1, 95% CI 1.3-7.2, P = 0.008]. CONCLUSION: Repeated ECG evaluation and HPL ambulatory monitoring are vital in identifying transient spT1 Brugada pattern and its associated risk.


Assuntos
Síndrome de Brugada , Morte Súbita Cardíaca , Eletrocardiografia Ambulatorial , Humanos , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/fisiopatologia , Masculino , Feminino , Eletrocardiografia Ambulatorial/métodos , Pessoa de Meia-Idade , Estudos Retrospectivos , Prognóstico , Adulto , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Medição de Risco , Valor Preditivo dos Testes , Fatores de Risco , Frequência Cardíaca , Idoso
20.
Europace ; 26(8)2024 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-39056247

RESUMO

AIMS: Short-term ambulatory electrocardiogram (ECG) monitoring is often used to assess premature atrial complex (PAC) and premature ventricular complex (PVC) frequency, but the diagnostic reliability is unknown. The objective of this study was to study the day-to-day variability of PAC and PVC frequency. METHODS AND RESULTS: We used 14-day full-disclosure mobile cardiac telemetry recordings without atrial fibrillation in 8245 US patients aged 17-103 years to calculate the diagnostic reliability of shorter ambulatory ECG recordings compared with 14-day averages. Over 14 days, 1853 patients had ≥500 PACs/day, 410 patients had ≥5000 PACs/day, and 197 patients had ≥10 000 PACs/day; 1640 patients had ≥500 PVCs/day, 354 patients had ≥5000 PVCs/day, and 175 patients had ≥10 000 PVCs/day. After 3 days, the estimated daily PAC frequency differed by ≥50% from the 14-day mean in 25% of patients; for PVCs, the corresponding duration was 7 days. Ten days of monitoring were needed to estimate PAC and PVC frequency within ±20% of the overall 14-day frequency in 80% of patients. For daily PAC and PVC frequencies ≥10 000, single-day estimation had a specificity of 99.3% [95% confidence interval (CI) 99.1-99.5] at a sensitivity of 76.6 (95% CI 70.1-80.4%) for PACs and a 99.6% (95% CI 99.4-99.7%) specificity at 79.4 (95% CI 72.7-85.2) sensitivity for PVCs. After 7 days, the sensitivity increased to 88.8% (95% CI 83.6-92.9) for PACs and 86.9% (95% CI 80.9-91.5%) for PVCs. CONCLUSION: While there is substantial daily variability across most PAC and PVC levels, findings of ≥10 000 PACs or PVCs are highly specific and do not need to be confirmed with longer recordings.


Assuntos
Complexos Atriais Prematuros , Eletrocardiografia Ambulatorial , Complexos Ventriculares Prematuros , Humanos , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/fisiopatologia , Pessoa de Meia-Idade , Idoso , Reprodutibilidade dos Testes , Feminino , Complexos Atriais Prematuros/diagnóstico , Complexos Atriais Prematuros/fisiopatologia , Eletrocardiografia Ambulatorial/métodos , Adulto , Masculino , Adolescente , Idoso de 80 Anos ou mais , Adulto Jovem , Fatores de Tempo , Telemetria , Valor Preditivo dos Testes , Frequência Cardíaca
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA