Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 272
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Nature ; 629(8013): 810-818, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38778234

RESUMO

Accurate and continuous monitoring of cerebral blood flow is valuable for clinical neurocritical care and fundamental neurovascular research. Transcranial Doppler (TCD) ultrasonography is a widely used non-invasive method for evaluating cerebral blood flow1, but the conventional rigid design severely limits the measurement accuracy of the complex three-dimensional (3D) vascular networks and the practicality for prolonged recording2. Here we report a conformal ultrasound patch for hands-free volumetric imaging and continuous monitoring of cerebral blood flow. The 2 MHz ultrasound waves reduce the attenuation and phase aberration caused by the skull, and the copper mesh shielding layer provides conformal contact to the skin while improving the signal-to-noise ratio by 5 dB. Ultrafast ultrasound imaging based on diverging waves can accurately render the circle of Willis in 3D and minimize human errors during examinations. Focused ultrasound waves allow the recording of blood flow spectra at selected locations continuously. The high accuracy of the conformal ultrasound patch was confirmed in comparison with a conventional TCD probe on 36 participants, showing a mean difference and standard deviation of difference as -1.51 ± 4.34 cm s-1, -0.84 ± 3.06 cm s-1 and -0.50 ± 2.55 cm s-1 for peak systolic velocity, mean flow velocity, and end diastolic velocity, respectively. The measurement success rate was 70.6%, compared with 75.3% for a conventional TCD probe. Furthermore, we demonstrate continuous blood flow spectra during different interventions and identify cascades of intracranial B waves during drowsiness within 4 h of recording.


Assuntos
Velocidade do Fluxo Sanguíneo , Encéfalo , Circulação Cerebrovascular , Ultrassonografia , Humanos , Velocidade do Fluxo Sanguíneo/fisiologia , Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia , Circulação Cerebrovascular/fisiologia , Imageamento Tridimensional/instrumentação , Imageamento Tridimensional/métodos , Erros Médicos , Razão Sinal-Ruído , Pele , Crânio , Sonolência/fisiologia , Ultrassonografia/instrumentação , Ultrassonografia/métodos , Adulto
2.
Annu Rev Biomed Eng ; 26(1): 49-65, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38166185

RESUMO

The democratization of ultrasound imaging refers to the process of making ultrasound technology more accessible. Traditionally, ultrasound imaging has been predominately used in specialized medical facilities by trained professionals. Advancements in technology and changes in the health-care landscape have inspired efforts to broaden the availability of ultrasound imaging to various settings such as remote and resource-limited areas. In this review, we highlight several key factors that have contributed to the ongoing democratization of ultrasound imaging, including portable and handheld devices, recent advancements in technology, and training and education. Examples of diagnostic point-of-care ultrasound (POCUS) imaging used in emergency and critical care, gastroenterology, musculoskeletal applications, and other practices are provided for both human and veterinary medicine. Open challenges and the future of POCUS imaging are presented, including the emerging role of artificial intelligence in technology development.


Assuntos
Sistemas Automatizados de Assistência Junto ao Leito , Ultrassonografia , Medicina Veterinária , Humanos , Ultrassonografia/métodos , Ultrassonografia/instrumentação , Medicina Veterinária/métodos , Animais , Inteligência Artificial
4.
Int J Hyperthermia ; 41(1): 2376681, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39111806

RESUMO

OBJECTIVE: To demonstrate the feasibility of using a ring array ultrasound (US) transducer, guided by ultrasound tomography (UST), for generating and monitoring mild hyperthermia (MHTh). METHODS: In silico and in vitro experiments were designed to evaluate the efficacy of a ring array US transducer for generating MHTh and monitoring changes in temperature. In a series of in silico studies, we compared the acoustic focal profiles produced by a ring array US transducer transmitting at different frequencies and further investigated the effectiveness of UST-guidance in implementing aberration correction to enhance the focal profile. In vitro experiments evaluated the capability of using a ring array US transducer to generate and maintain MHTh and the accuracy of using UST to monitor temperature changes. RESULTS: The simulations demonstrated that a ring array US transducer achieves symmetrical and localized acoustic focusing. In a heterogenous tissue model, a ring array US transducer achieved a superior acoustic focus by implementing aberration correction with guidance from UST. In vitro experiments demonstrated the capability of a ring array US transducer to generate MHTh in a tissue-mimicking phantom in an average of 117 ± 18 s and subsequently maintain MHTh. Lastly, a ring array US transducer utilized UST to track temperature changes in a preheated water-filled inclusion while it passively cooled from 45 °C to 25 °C, with a maximum error of 0.58 °C. CONCLUSION: A ring array US transducer can noninvasively generate and monitor MHTh, overcoming many limitations of current clinical systems. The closed geometry of the transducer is optimal for acoustic focusing and UST-guidance allows for improved aberration correction in a heterogenous medium. Utilizing UST thermometry with the same ring array US transducer will allow for implementing an image-guided, temperature-controlled, all-acoustic MHTh system.


Assuntos
Hipertermia Induzida , Transdutores , Hipertermia Induzida/métodos , Hipertermia Induzida/instrumentação , Humanos , Ultrassonografia/métodos , Ultrassonografia/instrumentação , Imagens de Fantasmas
5.
J Acoust Soc Am ; 156(1): 214-228, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38980099

RESUMO

Media that contain ultrasound scatterers arranged in a regular spatial distribution can be considered as structured. Structural effects affect quantitative ultrasound parameters that reflect the microstructure properties. Prior studies examined structural effects using simulations or phantoms with fixed microarchitecture, focusing on a limited set of ultrasound parameters, with limited attention given to their underlying physical significance. This study aims to investigate the concordance of the physical interpretations of multiple quantitative ultrasound parameters experimentally by introducing a phantom type with an adjustable microarchitecture. The phantom consists of an aqueous solution containing superparamagnetic microspheres, acting as scatterers. The spatial arrangement of the magnetic particles is modified by applying an external magnetic field, therefore changing the degree of structure of the phantom. Quantitative ultrasound parameters are estimated in three different configurations: the magnetic field intensity is varied over time, strength, and orientation. In each experiment, the backscatter coefficient and the envelope quantitative ultrasound parameters are successfully extracted (R2 ≈ 0.94). Their physical interpretations are supported by microphotographs and geometrical considerations through concordant hypotheses. This study paves the way for the use of magnetic phantoms. This methodology could be followed to validate theoretical scattering models and the physical meanings of quantitative ultrasound parameters.


Assuntos
Imagens de Fantasmas , Ultrassonografia , Ultrassonografia/métodos , Ultrassonografia/instrumentação , Campos Magnéticos , Ondas Ultrassônicas , Espalhamento de Radiação , Modelos Teóricos
6.
J Acoust Soc Am ; 156(2): 954-967, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39133632

RESUMO

Over the past few decades, early osteoporosis detection using ultrasonic bone quality evaluation has gained prominence. Specifically, various studies focused on axial transmission using ultrasonic guided waves and have highlighted this technique's sensitivity to intrinsic properties of long cortical bones. This work aims to demonstrate the potential of low-frequency ultrasonic guided waves to infer the properties of the bone inside which they are propagating. A proprietary ultrasonic transducer, tailored to transmit ultrasonic guided waves under 500 kHz, was used for the data collection. The gathered data underwent two-dimensional fast Fourier transform processing to extract experimental dispersion curves. The proposed inversion scheme compares experimental dispersion curves with simulated dispersion curves calculated through the semi-analytical iso-geometric analysis (SAIGA) method. The numerical model integrates a bone phantom plate coupled with a soft tissue layer on its top surface, mimicking the experimental bone phantom plates. Subsequently, the mechanical properties of the bone phantom plates were estimated by reducing the misfit between the experimental and simulated dispersion curves. This inversion leaned heavily on the dispersive trajectories and amplitudes of ultrasonic guided wave modes. Results indicate a marginal discrepancy under 5% between the mechanical properties ascertained using the SAIGA-based inversion and those measured using bulk wave pulse-echo measurements.


Assuntos
Osso Cortical , Imagens de Fantasmas , Ultrassonografia , Osso Cortical/diagnóstico por imagem , Osso Cortical/fisiologia , Ultrassonografia/métodos , Ultrassonografia/instrumentação , Análise de Fourier , Ondas Ultrassônicas , Humanos , Transdutores , Análise Numérica Assistida por Computador , Simulação por Computador
7.
Ultraschall Med ; 45(4): 405-411, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38428463

RESUMO

PURPOSE: Since handheld ultrasound devices are becoming increasingly ubiquitous, objective criteria to determine image quality are needed. We therefore conducted a comparison of objective quality measures and clinical performance. MATERIAL AND METHODS: A comparison of handheld devices (Butterfly IQ+, Clarius HD, Clarius HD3, Philips Lumify, GE VScan Air) and workstations (GE Logiq E10, Toshiba Aplio 500) was performed using a phantom. As a comparison, clinical investigations were performed by two experienced ultrasonographers by measuring the resolution of anatomical structures in the liver, pancreas, and intestine in ten subjects. RESULTS: Axial full width at half maximum resolution (FWHM) of 100µm phantom pins at depths between one and twelve cm ranged from 0.6-1.9mm without correlation to pin depth. Lateral FWHM resolution ranged from 1.3-8.7mm and was positively correlated with depth (r=0.6). Axial and lateral resolution differed between devices (p<0.001) with the lowest median lateral resolution observed in the E10 (5.4mm) and the lowest axial resolution (1.6mm) for the IQ+ device. Although devices showed no significant differences in most clinical applications, ultrasonographers were able to differentiate a median of two additional layers in the wall of the sigmoid colon and one additional structure in segmental portal fields (p<0.05) using cartwheel devices. CONCLUSION: While handheld devices showed superior or similar performance in the phantom and routine measurements, workstations still provided superior clinical imaging and resolution of anatomical substructures, indicating a lack of objective measurements to evaluate clinical ultrasound devices.


Assuntos
Desenho de Equipamento , Imagens de Fantasmas , Ultrassonografia , Humanos , Ultrassonografia/instrumentação , Ultrassonografia/métodos , Fígado/diagnóstico por imagem , Pâncreas/diagnóstico por imagem , Aumento da Imagem/instrumentação , Feminino , Sensibilidade e Especificidade , Intestinos/diagnóstico por imagem , Adulto , Miniaturização , Masculino
8.
Ultrason Imaging ; 46(3): 139-150, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38334055

RESUMO

Two-dimensional ultrasound transducers enable the acquisition of fully volumetric data that have been demonstrated to provide greater diagnostic information in the clinical setting and are a critical tool for emerging ultrasound methods, such as super-resolution and functional imaging. This technology, however, is not without its limitations. Due to increased fabrication complexity, some matrix probes with disjoint piezoelectric panels may require initial calibration. In this manuscript, two methods for calibrating the element positions of the Vermon 1024-channel 8 MHz matrix transducer are detailed. This calibration is a necessary step for acquiring high resolution B-mode images while minimizing transducer-based image degradation. This calibration is also necessary for eliminating vessel-doubling artifacts in super-resolution images and increasing the overall signal-to-noise ratio (SNR) of the image. Here, we show that the shape of the point spread function (PSF) can be significantly improved and PSF-doubling artifacts can be reduced by up to 10 dB via this simple calibration procedure.


Assuntos
Artefatos , Desenho de Equipamento , Razão Sinal-Ruído , Transdutores , Ultrassonografia , Calibragem , Ultrassonografia/métodos , Ultrassonografia/instrumentação , Imagens de Fantasmas
9.
Sensors (Basel) ; 24(9)2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38732843

RESUMO

As the number of electronic gadgets in our daily lives is increasing and most of them require some kind of human interaction, this demands innovative, convenient input methods. There are limitations to state-of-the-art (SotA) ultrasound-based hand gesture recognition (HGR) systems in terms of robustness and accuracy. This research presents a novel machine learning (ML)-based end-to-end solution for hand gesture recognition with low-cost micro-electromechanical (MEMS) system ultrasonic transducers. In contrast to prior methods, our ML model processes the raw echo samples directly instead of using pre-processed data. Consequently, the processing flow presented in this work leaves it to the ML model to extract the important information from the echo data. The success of this approach is demonstrated as follows. Four MEMS ultrasonic transducers are placed in three different geometrical arrangements. For each arrangement, different types of ML models are optimized and benchmarked on datasets acquired with the presented custom hardware (HW): convolutional neural networks (CNNs), gated recurrent units (GRUs), long short-term memory (LSTM), vision transformer (ViT), and cross-attention multi-scale vision transformer (CrossViT). The three last-mentioned ML models reached more than 88% accuracy. The most important innovation described in this research paper is that we were able to demonstrate that little pre-processing is necessary to obtain high accuracy in ultrasonic HGR for several arrangements of cost-effective and low-power MEMS ultrasonic transducer arrays. Even the computationally intensive Fourier transform can be omitted. The presented approach is further compared to HGR systems using other sensor types such as vision, WiFi, radar, and state-of-the-art ultrasound-based HGR systems. Direct processing of the sensor signals by a compact model makes ultrasonic hand gesture recognition a true low-cost and power-efficient input method.


Assuntos
Gestos , Mãos , Aprendizado de Máquina , Redes Neurais de Computação , Humanos , Mãos/fisiologia , Reconhecimento Automatizado de Padrão/métodos , Ultrassonografia/métodos , Ultrassonografia/instrumentação , Ultrassom/instrumentação , Algoritmos
10.
Sensors (Basel) ; 24(15)2024 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-39124070

RESUMO

Rehabilitation from musculoskeletal injuries focuses on reestablishing and monitoring muscle activation patterns to accurately produce force. The aim of this study is to explore the use of a novel low-powered wearable distributed Simultaneous Musculoskeletal Assessment with Real-Time Ultrasound (SMART-US) device to predict force during an isometric squat task. Participants (N = 5) performed maximum isometric squats under two medical imaging techniques; clinical musculoskeletal motion mode (m-mode) ultrasound on the dominant vastus lateralis and SMART-US sensors placed on the rectus femoris, vastus lateralis, medial hamstring, and vastus medialis. Ultrasound features were extracted, and a linear ridge regression model was used to predict ground reaction force. The performance of ultrasound features to predict measured force was tested using either the Clinical M-mode, SMART-US sensors on the vastus lateralis (SMART-US: VL), rectus femoris (SMART-US: RF), medial hamstring (SMART-US: MH), and vastus medialis (SMART-US: VMO) or utilized all four SMART-US sensors (Distributed SMART-US). Model training showed that the Clinical M-mode and the Distributed SMART-US model were both significantly different from the SMART-US: VL, SMART-US: MH, SMART-US: RF, and SMART-US: VMO models (p < 0.05). Model validation showed that the Distributed SMART-US model had an R2 of 0.80 ± 0.04 and was significantly different from SMART-US: VL but not from the Clinical M-mode model. In conclusion, a novel wearable distributed SMART-US system can predict ground reaction force using machine learning, demonstrating the feasibility of wearable ultrasound imaging for ground reaction force estimation.


Assuntos
Contração Isométrica , Ultrassonografia , Dispositivos Eletrônicos Vestíveis , Humanos , Ultrassonografia/métodos , Ultrassonografia/instrumentação , Masculino , Contração Isométrica/fisiologia , Adulto , Músculo Quadríceps/fisiologia , Músculo Quadríceps/diagnóstico por imagem , Músculo Esquelético/fisiologia , Músculo Esquelético/diagnóstico por imagem , Feminino , Adulto Jovem
11.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 55(3): 762-768, 2024 May 20.
Artigo em Zh | MEDLINE | ID: mdl-38948302

RESUMO

Objective: Ultrasound diagnosis and treatment is easy to perform and takes little time. It is widely used in clinical practice thanks to its non-invasive, real-time, and dynamic characteristics. In the process of ultrasound diagnosis and treatment, the probe may come into contact with the skin, the mucous membranes, and even the sterile parts of the body. However, it is difficult to achieve effective real-time disinfection of the probes after use and the probes are often reused, leading to the possibility of the probes carrying multiple pathogenic bacteria. At present, the processing methods for probes at home and abroad mainly include probe cleaning, probe disinfection, and physical isolation (using probe covers or sheaths). Yet, each approach has its limitations and cannot completely prevent probe contamination and infections caused by ultrasound diagnosis and treatment. For example, when condoms are used as the probe sheath, the rate of condom breakage is relatively high. The cutting and fixing of cling film or freezer bags involves complicated procedures and is difficult to perform. Disposable plastic gloves are prone to falling off and causing contamination and are hence not in compliance with the principles of sterility. Furthermore, the imaging effect of disposable plastic gloves is poor. Therefore, there is an urgent need to explore new materials to make probe covers that can not only wrap tightly around the ultrasound probe, but also help achieve effective protection and rapid reuse. Based on the concept of physical barriers, we developed in this study a heat sealing system for the rapid reuse of ultrasound probes. The system uses a heat sealing device to shrink the protective film so that it wraps tightly against the surface of the ultrasound probe, allowing for the rapid reuse of the probe while reducing the risk of nosocomial infections. The purpose of this study is to design a heat sealing system for the rapid reuse of ultrasound probes and to verify its application effect on the rapid reuse of ultrasound probes. Methods: 1) The heat sealing system for the rapid reuse of ultrasound probes was designed and tested by integrating medical and engineering methods. The system included a protective film (a multilayer co-extruded polyolefin thermal shrinkable film) and a heat sealing device, which included heating wire components, a blower, a photoelectric switch, temperature sensors, a control and drive circuit board, etc. According to the principle of thermal shrinkage, the ultrasound probe equipped with thermal shrinkable film was rapidly heated and the film would wrap closely around the ultrasound probe placed on the top of the heat sealing machine. The ultrasound probe was ready for use after the thermal shrinkage process finished. Temperature sensors were installed on the surface of the probe to test the thermal insulation performance of the system. The operation procedures of the system are as follows: placing the ultrasound probe covered with the protective film in a certain space above the protective air vent, which is detected by the photoelectric switch; the heating device heats the thermal shrinkable film with a constant flow of hot air at a set temperature value. Then, the probe is rotated so that the thermal shrinkable film will quickly wrap around the ultrasound probe. After the heat shrinking is completed, the probe can be used directly. 2) Using the convenience sampling method, 90 patients from the Department of Anesthesiology and Perioperative Medicine, the First Affiliated Hospital of Xi'an Jiaotong University were included as the research subjects. All patients were going to undergo arterial puncture under ultrasound guidance. The subjects were divided into 3 groups, with 30 patients in each group. Three measures commonly applied in clinical practice were used to process the probes in the three groups and water-soluble fluorescent labeling was applied around the puncture site before use. In the experimental group, the probes were processed with the heat sealing system. The standard operating procedures of the heat sealing system for rapid reuse of ultrasonic probes were performed to cover the ultrasonic probe and form a physical barrier to prevent probe contamination. There were two control groups. In control group 1, disinfection wipes containing double-chain quaternary ammonium salt were used to repeatedly wipe the surface of the probe for 10-15 times, and then the probe was ready for use once it dried up. In the control group 2, a disposable protective sheath was used to cover the front end of the probe and the handle end of the sheath was tied up with threads. Comparison of the water-soluble fluorescent labeling on the surface of the probe (which reflected the colony residues on the surface of the probe) before and after use and the reuse time (i.e., the lapse of time from the end of the first use to the beginning of the second use) were made between the experimental group and the two control groups. Results: 1) The temperature inside the ultrasound probe was below 40 ℃ and the heat sealing system for rapid reuse did not affect the performance of the ultrasound probe. 2) The reuse time in the heat sealing system group, as represented by (median [P25, P75]), was (8.00 [7.00, 10.00]) s, which was significantly lower than those of the disinfection wipe group at (95.50 [8.00, 214.00]) s and the protective sleeve group at (25.00 [8.00, 51.00]) s, with the differences being statistically significant (P<0.05). No fluorescence residue was found on the probe in either the heat sealing system group or the protective sheath group after use. The fluorescence residue in the heat sealing system group was significantly lower than that in the disinfection wipes group, showing statistically significant differences (χ 2=45.882, P<0.05). Conclusion: The thermal shrinkable film designed and developed in this study can be cut and trimmed according to the size of the equipment. When the film is heated, it shrinks and wraps tightly around the equipment, forming a sturdy protective layer. With the heat sealing system for rapid reuse of ultrasonic probes, we have realized the semi-automatic connection between the thermal shrinkable film and the heating device, reducing the amount of time-consuming and complicated manual operation. Furthermore, the average reuse time is shortened and the system is easy to use, which contributes to improvements in the reuse and operation efficiency of ultrasound probes. The heat sealing system reduces colony residues on the surface of the probe and forms an effective physical barrier on the probe. No probes were damaged in the study. The heat sealing system for rapid reuse of ultrasonic probes can be used as a new method to process the ultrasonic probes.


Assuntos
Ultrassonografia , Ultrassonografia/instrumentação , Ultrassonografia/métodos , Temperatura Alta , Reutilização de Equipamento , Humanos , Desinfecção/métodos , Desinfecção/instrumentação , Desenho de Equipamento , Contaminação de Equipamentos/prevenção & controle
12.
Ultrasound Med Biol ; 50(8): 1178-1182, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38705784

RESUMO

OBJECTIVE: Although hand-held ultrasound devices (HHUSDs) are currently used for a diverse range of diagnostic and interventional applications the imaging performance of such scanners is rarely considered. The aim of this study was to assess the imaging performance of a wide-range of HHUSDs and compare their imaging performance to cart-based systems utilized for the same clinical applications. METHODS: The grayscale imaging performances of 19 HHUSDs from eight different manufacturers, manufactured between 2016 and 2021, were measured using a figure-of-merit known as the resolution integral. The imaging performance of the HHUSDs were compared to 142 cart-based ultrasound scanners. RESULTS: The HHUSD with the overall highest resolution integral (66) was a Butterfly (Burlington, MA, USA) wired phased array for small parts applications, followed by a Philips (Bothell, WA, USA) Lumify wired curvilinear transducer (57) for abdominal applications, a Butterfly wired phased array (56) for abdominal applications, a GE (Freiburg, Baden-Wurttemberg, Germany) VScan Air wireless linear array (56) for small parts applications, and a Healcerion (Seoul, Korea) Sonon 300L wireless linear array (56) for small parts applications. A GE VScan Extend wired phased array had the highest resolution integral (44) for cardiac applications. CONCLUSIONS: The Butterfly phased array had the highest resolution integral of all the 19 HHUSDs, although this value is still less than the majority of cart-based cardiac and abdominal ultrasound scanners manufactured from 2010 to 2017. Clinical users of HHUSDs should be mindful of the limitations in imaging performance of hand-held ultrasound devices.


Assuntos
Desenho de Equipamento , Imagens de Fantasmas , Ultrassonografia , Ultrassonografia/instrumentação , Ultrassonografia/métodos , Transdutores
13.
Comput Biol Med ; 174: 108453, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38636327

RESUMO

PURPOSE: Biopsies play a crucial role in determining the classification and staging of tumors. Ultrasound is frequently used in this procedure to provide real-time anatomical information. Using augmented reality (AR), surgeons can visualize ultrasound data and spatial navigation information seamlessly integrated with real tissues. This innovation facilitates faster and more precise biopsy operations. METHODS: We have developed an augmented reality biopsy navigation system characterized by low display latency and high accuracy. Ultrasound data is initially read by an image capture card and streamed to Unity via net communication. In Unity, navigation information is rendered and transmitted to the HoloLens 2 device using holographic remoting. Concurrently, a retro-reflective tool tracking method is implemented on the HoloLens 2, enabling the simultaneous tracking of the ultrasound probe and biopsy needle. Distinct navigation information is provided during in-plane and out-of-plane punctuation. To evaluate the effectiveness of our system, we conducted a study involving ten participants, assessing puncture accuracy and biopsy time in comparison to traditional methods. RESULTS: Ultrasound image was streamed from the ultrasound device to augmented reality headset with 122.49±11.61ms latency, while only 16.22±11.25ms was taken after data acquisition from image capture card. Navigation accuracy reached 1.23±0.68mm in the image plane and 0.95±0.70mm outside the image plane, within a depth range of 200 millimeters. Remarkably, the utilization of our system led to 98% and 95% success rate in out-of-plane and in-plane biopsy, among ten participants with little ultrasound experience. CONCLUSION: To sum up, this paper introduces an AR-based ultrasound biopsy navigation system characterized by high navigation accuracy and minimal latency. The system provides distinct visualization contents during in-plane and out-of-plane operations according to their different characteristics. Use case study in this paper proved that our system can help young surgeons perform biopsy faster and more accurately.


Assuntos
Realidade Aumentada , Humanos , Ultrassonografia/métodos , Ultrassonografia/instrumentação , Biópsia Guiada por Imagem/instrumentação , Biópsia Guiada por Imagem/métodos
14.
Nat Commun ; 15(1): 5197, 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38890294

RESUMO

Untethered miniature soft robots have significant application potentials in biomedical and industrial fields due to their space accessibility and safe human interaction. However, the lack of selective and forceful actuation is still challenging in revolutionizing and unleashing their versatility. Here, we propose a focused ultrasound-controlled phase transition strategy for achieving millimeter-level spatially selective actuation and Newton-level force of soft robots, which harnesses ultrasound-induced heating to trigger the phase transition inside the robot, enabling powerful actuation through inflation. The millimeter-level spatial resolution empowers single robot to perform multiple tasks according to specific requirements. As a concept-of-demonstration, we designed soft robot for liquid cargo delivery and biopsy robot for tissue acquisition and patching. Additionally, an autonomous control system is integrated with ultrasound imaging to enable automatic acoustic field alignment and control. The proposed method advances the spatiotemporal response capability of untethered miniature soft robots, holding promise for broadening their versatility and adaptability.


Assuntos
Robótica , Robótica/instrumentação , Robótica/métodos , Desenho de Equipamento , Humanos , Ondas Ultrassônicas , Transição de Fase , Ultrassonografia/métodos , Ultrassonografia/instrumentação
15.
J Biophotonics ; 17(7): e202400058, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38695390

RESUMO

Vascular diseases are a leading cause of death and disability worldwide. Despite having precursor conditions like peripheral arterial disease (PAD), they are often only diagnosed after the onset of stroke or heart attack. Low-cost, portable, noninvasive, point-of-care (POC), label-free assessment of deep vascular function benefits PAD diagnosis, especially in resource poor settings of the world. Doppler ultrasound-based blood flow measurements can diagnose PAD, albeit with limited sensitivity and specificity. To overcome this, here, we propose the first-of-its-kind dual-modality photoacoustic-and-ultrasound (PAUS) imaging system that integrates a multiwavelength pulsed laser diode (PLD) with a compact ultrasound data acquisition unit. The mesoscopic imaging depth of the portable PLD-PAUS system was validated using tissue phantoms, and its multispectral photoacoustic imaging capabilities were validated using an atherosclerosis-mimicking phantom. Furthermore, we demonstrated high-contrast volumetric in vivo photoacoustic imaging of rodent abdominal vasculature and quantified vessel reactivity due to hypercapnia stimulation. The multiparametric functional and molecular imaging capabilities of the PLD-PAUS system holds promise for POC applications.


Assuntos
Imagens de Fantasmas , Técnicas Fotoacústicas , Sistemas Automatizados de Assistência Junto ao Leito , Ultrassonografia , Técnicas Fotoacústicas/instrumentação , Animais , Ultrassonografia/instrumentação , Lasers Semicondutores , Ratos , Camundongos
16.
Artigo em Inglês | MEDLINE | ID: mdl-38635378

RESUMO

Thin-film piezoelectric micromachined ultrasound transducers (PMUTs) are an increasingly relevant and well-researched field, and their biomedical importance has been growing as the technology continues to mature. This review article briefly discusses their history in biomedical use, provides a simple explanation of their principles for newer readers, and sheds light on the materials selection for these devices. Primarily, it discusses the significant applications of PMUTs in the biomedical industry and showcases recent progress that has been made in each application. The biomedical applications covered include common historical uses of ultrasound such as ultrasound imaging, ultrasound therapy, and fluid sensing, but additionally new and upcoming applications such as drug delivery, photoacoustic imaging, thermoacoustic imaging, biometrics, and intrabody communication. By including a device comparison chart for different applications, this review aims to assist microelectromechanical systems (MEMS) designers that work with PMUTs by providing a benchmark for recent research works. Furthermore, it puts forth a discussion on the current challenges being faced by PMUTs in the biomedical field, current and likely future research trends, and opportunities for PMUT development areas, as well as sharing the opinions and predictions of the authors on the state of this technology as a whole. The review aims to be a comprehensive introduction to these topics without diving excessively deep into existing literature.


Assuntos
Desenho de Equipamento , Transdutores , Ultrassonografia , Ultrassonografia/instrumentação , Ultrassonografia/métodos , Humanos , Sistemas Microeletromecânicos/instrumentação , Microtecnologia/instrumentação
17.
Adv Sci (Weinh) ; 11(22): e2400271, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38647427

RESUMO

Tissue-mimicking phantoms are valuable tools that aid in improving the equipment and training available to medical professionals. However, current phantoms possess limited utility due to their inability to precisely simulate multiple physical properties simultaneously, which is crucial for achieving a system understanding of dynamic human tissues. In this work, novel materials design and fabrication processes to produce various tissue-mimicking materials (TMMs) for skin, adipose, muscle, and soft tissue at a human scale are developed. Target properties (Young's modulus, density, speed of sound, and acoustic attenuation) are first defined for each TMM based on literature. Each TMM recipe is developed, associated mechanical and acoustic properties are characterized, and the TMMs are confirmed to have comparable mechanical and acoustic properties with the corresponding human tissues. Furthermore, a novel sacrificial core to fabricate a hollow, ellipsoid-shaped bladder phantom complete with inlet and outlet tubes, which allow liquids to flow through and expand this phantom, is adopted. This dynamic bladder phantom with realistic mechanical and acoustic properties to human tissues in combination with the developed skin, soft tissue, and subcutaneous adipose tissue TMMs, culminates in a human scale torso tank and electro-mechanical system that can be systematically utilized for characterizing various medical imaging devices.


Assuntos
Imagens de Fantasmas , Humanos , Materiais Biomiméticos/química , Ultrassonografia/métodos , Ultrassonografia/instrumentação , Acústica/instrumentação , Desenho de Equipamento/métodos , Módulo de Elasticidade
18.
PLoS One ; 19(5): e0300451, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38739643

RESUMO

PURPOSE: The aim of this study was to evaluate the imaging capabilities of Butterfly iQ with conventional ophthalmic (piezoelectric) ultrasound (COU) for ophthalmic imaging. METHODS: Custom phantom molds were designed and imaged with Butterfly iQ and COU to compare spatial resolution capabilities. To evaluate the clinical imaging performance of Butterfly iQ and COU, a survey containing pathological conditions from human subjects, imaged with both Butterfly iQ and COU probes, was given to three retina specialists and graded on image detail, resolution, quality, and diagnostic confidence on a ten-point Likert scale. Kruskal-Wallis analysis was performed for survey responses. RESULTS: Butterfly iQ and COU had comparable capabilities for imaging small axial and lateral phantom features (down to 0.1 mm) of high and low acoustic reflectivity. One of three retina specialists demonstrated a statistically significant preference for COU related to resolution, detail, and diagnostic confidence, but the remaining graders showed no significant preference for Butterfly iQ or COU across all sample images presented. CONCLUSION: The emergence of portable ultrasound probes offers an affordable alternative to COU technologies with comparable qualitative imaging resolution down to 0.1 mm. These findings suggest the value to further study the use of portable ultrasound systems and their utility in routine eye care.


Assuntos
Imagens de Fantasmas , Ultrassonografia , Humanos , Ultrassonografia/métodos , Ultrassonografia/instrumentação , Oftalmopatias/diagnóstico por imagem
19.
IEEE Trans Biomed Eng ; 71(9): 2699-2707, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38607722

RESUMO

OBJECTIVE: We demonstrate the use of ultrasound to receive an acoustic signal transmitted from a radiological clip designed from a custom circuit. This signal encodes an identification number and is localized and identified wirelessly by the ultrasound imaging system. METHODS: We designed and constructed the test platform with a Teensy 4.0 microcontroller core to detect ultrasonic imaging pulses received by a transducer embedded in a phantom, which acted as the radiological clip. Ultrasound identification (USID) signals were generated and transmitted as a result. The phantom and clip were imaged using an ultrasonic array (Philips L7-4) connected to a Verasonics™ Vantage 128 system operating in pulse inversion (PI) mode. Cross-correlations were performed to localize and identify the code sequences in the PI images. RESULTS: USID signals were detected and visualized on B-mode images of the phantoms with up to sub-millimeter localization accuracy. The average detection rate across 30,400 frames of ultrasound data was 98.1%. CONCLUSION: The USID clip produced identifiable, distinguishable, and localizable signals when imaged. SIGNIFICANCE: Radiological clips are used to mark breast cancer being treated by neoadjuvant chemotherapy (NAC) via implant in or near treated lesions. As NAC progresses, available marking clips can lose visibility in ultrasound, the imaging modality of choice for monitoring NAC-treated lesions. By transmitting an active signal, more accurate and reliable ultrasound localization of these clips could be achieved and multiple clips with different ID values could be imaged in the same field of view.


Assuntos
Desenho de Equipamento , Imagens de Fantasmas , Ultrassonografia , Ultrassonografia/métodos , Ultrassonografia/instrumentação , Processamento de Sinais Assistido por Computador , Humanos , Transdutores
20.
Phys Med Biol ; 69(12)2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38815603

RESUMO

Objective. The transmit encoding model for synthetic aperture imaging is a robust and flexible framework for understanding the effects of acoustic transmission on ultrasound image reconstruction. Our objective is to use machine learning (ML) to construct scanning sequences, parameterized by time delays and apodization weights, that produce high-quality B-mode images.Approach. We use a custom ML model in PyTorch with simulated RF data from Field II to probe the space of possible encoding sequences for those that minimize a loss function that describes image quality. This approach is made computationally feasible by a novel formulation of the derivative for delay-and-sum beamforming.Main results. When trained for a specified experimental setting (imaging domain, hardware restrictions, etc), our ML model produces optimized encoding sequences that, when deployed in the REFoCUS imaging framework, improve a number of standard quality metrics over conventional sequences including resolution, field of view, and contrast. We demonstrate these results experimentally on both wire targets and a tissue-mimicking phantom.Significance. This work demonstrates that the set of commonly used encoding schemes represent only a narrow subset of those available. Additionally, it demonstrates the value for ML tasks in synthetic transmit aperture imaging to consider the beamformer within the model, instead of purely as a post-processing step.


Assuntos
Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Ultrassonografia , Ultrassonografia/instrumentação , Ultrassonografia/métodos , Processamento de Imagem Assistida por Computador/métodos , Aprendizado de Máquina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA