[Color M-mode Doppler for postoperative estimation of pulmonary capillary wedge pressure]. / Estimation postopératoire de la pression artérielle pulmonaire d'occlusion par étude Doppler, en mode M couleur, du flux transmitral.
Ann Fr Anesth Reanim
; 23(9): 873-8, 2004 Sep.
Article
em Fr
| MEDLINE
| ID: mdl-15471634
OBJECTIVE: The aim of this study was to evaluate the accuracy of the combined index E/Vp (peak E velocity combined with color M-mode color Doppler flow propagation) for estimating pulmonary capillary wedge pressure, in post cardiac surgery patients. STUDY DESIGN: Prospective clinical trial. PATIENTS AND METHODS: In post cardiac surgery patients (D1), we have measured with transthoracic echocardiography peak early E transmitral pulsed Doppler velocities and color M-mode Doppler flow propagation velocity (Vp). The E/Vp ratio was compared with pulmonary capillary wedge pressure (PAPO) obtained simultaneously. RESULTS: Thirty eight patients were studied. The coefficient of correlation between PAPO and E/Vp was r = 0.71 (p < 0.0001). The sensitivity and the specificity of E/Vp > 1.5 for prediction of PAPO > 15 mmHg were 79% and 79% respectively. CONCLUSION: In post cardiac surgery patients, PAPO can be reasonably estimated by measuring the ratio E/Vp obtained with Doppler echocardiography.
Buscar no Google
Base de dados:
MEDLINE
Assunto principal:
Pressão Propulsora Pulmonar
Tipo de estudo:
Evaluation_studies
/
Observational_studies
/
Prognostic_studies
/
Risk_factors_studies
Limite:
Aged
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
Fr
Ano de publicação:
2004
Tipo de documento:
Article