Your browser doesn't support javascript.
loading
Regurgitant flow in cardiac valve prostheses: diagnostic value of gradient echo nuclear magnetic resonance imaging in reference to transesophageal two-dimensional color Doppler echocardiography.
Deutsch, H J; Bachmann, R; Sechtem, U; Curtius, J M; Jungehülsing, M; Schicha, H; Hilger, H H.
Afiliação
  • Deutsch HJ; Klinik III für Innere Medizin, University of Cologne, Germany.
J Am Coll Cardiol ; 19(7): 1500-7, 1992 Jun.
Article em En | MEDLINE | ID: mdl-1593045
ABSTRACT
Gradient echo nuclear magnetic resonance (NMR) imaging and transesophageal two-dimensional color Doppler echocardiography are flow-sensitive techniques that have been used in the diagnosis and grading of valvular regurgitation. To define the diagnostic value of gradient echo NMR imaging in the detection of regurgitant flow in cardiac valve prostheses and the differentiation of physiologic leakage flow from pathologic transvalvular or paravalvular leakage flow, 47 patients with 55 valve prostheses were examined. Color Doppler transesophageal echocardiography was used for comparison. Surgical confirmation of findings was obtained in 11 patients with 13 valve prostheses. Gradient echo NMR imaging showed regurgitant flow in 37 of 43 valves with a jet seen on transesophageal echocardiography and it detected physiologic leakage flow in 4 additional valves. There was 96% agreement between the two methods in distinguishing between physiologic and pathologic leakage flow. The methods differed on jet origin of pathologic leakage flow in six prostheses. The degree of regurgitation was graded by both NMR imaging and transesophageal echocardiography, according to the area of the regurgitant jet visualized; gradings were identical for 75% of valve prostheses. Quantification of jet length and area showed a good correlation between the two methods (r = 0.85 and r = 0.91, respectively). Gradient echo NMR imaging is a useful noninvasive technique for the detection, localization and estimation of regurgitant flow in cardiac valve prostheses. However, because transesophageal echocardiography is less time-consuming and less expensive, gradient echo NMR imaging is unlikely to displace transesophageal echocardiography and should be used only in the occasional patient who cannot be adequately imaged by echocardiography.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Próteses Valvulares Cardíacas / Imageamento por Ressonância Magnética / Ecocardiografia Doppler / Doenças das Valvas Cardíacas Tipo de estudo: Diagnostic_studies Limite: Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 1992 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Próteses Valvulares Cardíacas / Imageamento por Ressonância Magnética / Ecocardiografia Doppler / Doenças das Valvas Cardíacas Tipo de estudo: Diagnostic_studies Limite: Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 1992 Tipo de documento: Article