Importance of precise positioning for proton beam therapy in the base of skull and cervical spine.
Tatsuzaki, H; Urie, M M.
Afiliação
  • Tatsuzaki H; Department of Radiation Medicine, Massachusetts General Hospital, Boston.
Int J Radiat Oncol Biol Phys ; 21(3): 757-65, 1991 Aug.
Article em En | MEDLINE | ID: mdl-1651308
ABSTRACT
Using proton beam therapy, high doses have been delivered to chordomas and chondrosarcomas of the base of skull and cervical spine. Dose inhomogeneity to the tumors has been accepted in order to maintain normal tissue tolerances, and detailed attention to patient immobilization and to precise positioning has minimized the margins necessary to ensure these dose constraints. This study examined the contribution of precise positioning to the better dose localization achieved in these treatments. Three patients whose tumors represented different anatomic geometries were studied. Treatment plans were developed which treated as much of the tumor as possible to 74 Cobalt-Gray-Equivalent (CGE) while maintaining the central brain stem and central spinal cord at less than or equal to 48 CGE, the surface of the brain stem, surface of the spinal cord, and optic structures at less than or equal to 60 CGE, and the temporal lobes at less than or equal to 5% likelihood of complication using a biophysical model of normal tissue complication probability. Two positioning accuracies were assumed 3 mm and 10 mm. Both proton beam plans and 10 MV X ray beam plans were developed with these assumptions and dose constraints. In all cases with the same positioning uncertainties, the proton beam plans delivered more dose to a larger percentage of the tumor volume and the estimated tumor control probability was higher than with the X ray plans. However, without precise positioning both the proton plans and the X ray plans deteriorated, with a 12% to 25% decrease in estimated tumor control probability. In all but one case, the difference between protons with good positioning and poor positioning was greater than the difference between protons and X rays, both with good positioning. Hence in treating these tumors, which are in close proximity to critical normal tissues, attention to immobilization and precise positioning is essential. With good positioning, proton beam therapy permits higher doses to significantly more of the tumor in these sites than do X rays.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Prótons / Neoplasias Cranianas / Neoplasias da Coluna Vertebral / Cordoma / Vértebras Cervicais / Radioterapia de Alta Energia Tipo de estudo: Prognostic_studies Limite: Adult / Child / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 1991 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Prótons / Neoplasias Cranianas / Neoplasias da Coluna Vertebral / Cordoma / Vértebras Cervicais / Radioterapia de Alta Energia Tipo de estudo: Prognostic_studies Limite: Adult / Child / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 1991 Tipo de documento: Article