Your browser doesn't support javascript.
loading
Detection of atrial high-rate events by continuous home monitoring: clinical significance in the heart failure-cardiac resynchronization therapy population.
Shanmugam, Nesan; Boerdlein, Annegret; Proff, Jochen; Ong, Peter; Valencia, Oswaldo; Maier, Sebastian K G; Bauer, Wolfgang R; Paul, Vince; Sack, Stefan.
Afiliação
  • Shanmugam N; Department of Cardiology, St George's Healthcare NHS Trust, London, UK.
Europace ; 14(2): 230-7, 2012 Feb.
Article em En | MEDLINE | ID: mdl-21933802
ABSTRACT

AIMS:

Uncertainty exists over the importance of device-detected short-duration atrial arrhythmias. Continuous atrial diagnostics, through home monitoring (HM) technology (BIOTRONIK, Berlin, Germany), provides a unique opportunity to assess frequency and quantity of atrial fibrillation (AF) episodes defined as atrial high-rate events (AHRE). METHODS AND

RESULTS:

Prospective data from 560 heart failure (HF) patients (age 67 ± 10 years, median ejection fraction 27%) patients with a cardiac resynchronization therapy (CRT) device capable of HM from two multi-centre studies were analysed. Atrial high-rate events burden was defined as the duration of mode switch in a 24-h period with atrial rates of >180 beats for at least 1% or total of 14 min per day. The primary endpoint was incidence of a thromboembolic (TE) event. Secondary endpoints were cardiovascular death, hospitalization because of AF, or worsening HF. Over a median 370-day follow-up AHRE occurred in 40% of patients with 11 (2%) patients developing TE complications and mortality rate of 4.3% (24 deaths, 16 with cardiovascular aetiology). Compared with patients without detected AHRE, patients with detected AHRE>3.8 h over a day were nine times more likely to develop TE complications (P= 0.006). The majority of patients (73%) did not show a temporal association with the detected atrial episode and their adverse event, with a mean interval of 46.7 ± 71.9 days (range 0-194) before the TE complication.

CONCLUSION:

In a high-risk cohort of HF patients, device-detected atrial arrhythmias are associated with an increased incidence of TE events. A cut-off point of 3.8 h over 24 h was associated with significant increase in the event rate. Routine assessment of AHRE should be considered with other data when assessing stroke risk and considering anti-coagulation initiation and should also prompt the optimization of cardioprotective HF therapy in CRT patients.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fibrilação Atrial / Eletrocardiografia Ambulatorial / Insuficiência Cardíaca / Serviços de Assistência Domiciliar Tipo de estudo: Clinical_trials / Diagnostic_studies / Etiology_studies / Evaluation_studies / Incidence_studies / Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male Idioma: En Ano de publicação: 2012 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fibrilação Atrial / Eletrocardiografia Ambulatorial / Insuficiência Cardíaca / Serviços de Assistência Domiciliar Tipo de estudo: Clinical_trials / Diagnostic_studies / Etiology_studies / Evaluation_studies / Incidence_studies / Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male Idioma: En Ano de publicação: 2012 Tipo de documento: Article