Computed tomography hepatic arteriography has a hepatic falciform artery detection rate that is much higher than that of digital subtraction angiography and 99mTc-MAA SPECT/CT: implications for planning 90Y radioembolization?
Burgmans, M C; Too, C W; Kao, Y H; Goh, A S W; Chow, P K H; Tan, B S; Tay, K H; Lo, R H G.
Afiliação
  • Burgmans MC; Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, Singapore 169608, Singapore. mburgmans@hotmail.com
Eur J Radiol ; 81(12): 3979-84, 2012 Dec.
Article em En | MEDLINE | ID: mdl-22954411
ABSTRACT

PURPOSE:

To compare the hepatic falciform artery (HFA) detection rates of digital subtraction angiography (DSA), computed tomography hepatic arteriography (CTHA) and 99mTc-macroaggregated albumin (99mTc-MAA) single photon emission computed tomography with integrated CT (SPECT/CT) and to correlate HFA patency with complication rates of yttrium-90 (90Y) radioembolization. MATERIAL AND

METHODS:

From August 2008 to November 2010, 79 patients (range 23-83 years, mean 62.3 years; 67 male) underwent pre-treatment DSA, CTHA and 99mTc-MAA scintigraphy (planar/SPECT/CT) to assess suitability for radioembolization with 90Y resin microspheres. Thirty-seven patients were excluded from the study, because CTHA was performed with a catheter position that did not result in opacification of the liver parenchyma adjacent to the falciform ligament. DSA, CTHA and 99mTc-MAA SPECT/CT images and medical records were retrospectively reviewed.

RESULTS:

A patent HFA was detected in 22 of 42 patients (52.3%). The HFA detection rates of DSA, CTHA and 99mTc-MAA SPECT/CT were 11.9%, 52.3% and 13.3%, respectively (p<0.0001). An origin from the segment 4 artery was seen in 51.7% of HFAs. Prophylactic HFA coil-embolization prior to 90Y microspheres infusion was performed in 2 patients. Of the patients who underwent radioembolization with a patent HFA, none developed supra-umbilical radiation dermatitis. One patient experienced epigastric pain attributed to post-embolization syndrome and was managed conservatively.

CONCLUSION:

The HFA detection rate of CTHA is superior to that of DSA and 99mTc-MAA SPECT/CT. Complications related to non-target radiation of the HFA vascular territory rarely occur, even in patients undergoing radioembolization with a patent HFA.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Radioisótopos de Ítrio / Tomografia Computadorizada por Raios X / Angiografia Digital / Agregado de Albumina Marcado com Tecnécio Tc 99m / Tomografia por Emissão de Pósitrons / Imagem Multimodal / Artéria Hepática / Neoplasias Hepáticas Tipo de estudo: Clinical_trials / Diagnostic_studies / Prognostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2012 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Radioisótopos de Ítrio / Tomografia Computadorizada por Raios X / Angiografia Digital / Agregado de Albumina Marcado com Tecnécio Tc 99m / Tomografia por Emissão de Pósitrons / Imagem Multimodal / Artéria Hepática / Neoplasias Hepáticas Tipo de estudo: Clinical_trials / Diagnostic_studies / Prognostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2012 Tipo de documento: Article