Your browser doesn't support javascript.
loading
Evaluation of automated immunoassays in the diagnosis of heparin induced thrombocytopenia.
Althaus, Karina; Hron, Gregor; Strobel, Ulrike; Abbate, Rosanna; Rogolino, Angela; Davidson, Simon; Greinacher, Andreas; Bakchoul, Tamam.
Afiliação
  • Althaus K; Institute for Immunology and Transfusion Medicine, Ernst-Moritz-Arndt University Greifswald, Germany.
Thromb Res ; 131(3): e85-90, 2013 Mar.
Article em En | MEDLINE | ID: mdl-23351665
BACKGROUND: Heparin-induced thrombocytopenia (HIT) is caused by platelet-activating antibodies that recognize platelet factor 4/heparin (PF4/hep) complexes. The in vitro demonstration of PF4/hep antibodies using functional and immunological methods is essential for optimal management of patients suspected to have HIT. Since functional assays are technically challenging and limited to specialized laboratories, antigen-binding assays are commonly used in routine laboratories. STUDY DESIGN: Blood samples from 448 consecutive patients in whom HIT was suspected were investigated using a latex agglutination test HemosIL® HIT-Ab(PF4-H) (HemosIL-Ab), two chemiluminescence tests HemosIL AcuStar HIT-Ab(PF4-H) (HemosIL AcuStar-Ab) and AcuStar HIT-IgG(PF4-H) (HemosIL AcuStar-IgG), an in-house PF4/hep IgG enzyme immunoassay (EIA) and the heparin induced platelet aggregation (HIPA) test. RESULTS: Antibodies against PF4/hep were detectable in 44 out of 119 samples using HemosIL-Ab among which 20 samples were also reactive in the HIPA; and in 122, 64 and 108 out of 448 sera using HemosIL AcuStar-Ab, HemosIL AcuStar-IgG and in-house PF4/hep IgG-EIA, respectively, among which 52 sera were also reactive in the HIPA. All assays had high sensitivities of >95% for platelet activating antibodies; however, they differed in their specificities. The highest specificity and positive predictive value was observed by HemosIL AcuStar-IgG (96% and 78%, respectively). CONCLUSION: Automated immunoassays are useful in the laboratory investigations of HIT and present a potential improvement toward standardization of laboratory investigations of HIT. The high positive predictive capability may justify treating the patient with alternative anticoagulants without waiting for the results of a functional assay.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Trombocitopenia / Imunoensaio / Heparina Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2013 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Trombocitopenia / Imunoensaio / Heparina Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2013 Tipo de documento: Article