Phase-shift perfluorocarbon agents enhance high intensity focused ultrasound thermal delivery with reduced near-field heating.
Phillips, Linsey C; Puett, Connor; Sheeran, Paul S; Wilson Miller, G; Matsunaga, Terry O; Dayton, Paul A.
Afiliação
  • Phillips LC; Department of Biomedical Engineering, University of North Carolina at Chapel Hill, 109 Mason Farm Road, 304 Taylor Hall, CB 7575, Chapel Hill, North Carolina 27599, USA. linsey@email.unc.edu
J Acoust Soc Am ; 134(2): 1473-82, 2013 Aug.
Article em En | MEDLINE | ID: mdl-23927187
ABSTRACT
Ultrasound contrast agents are known to enhance high intensity focused ultrasound (HIFU) ablation, but these perfluorocarbon microbubbles are limited to the vasculature, have a short half-life in vivo, and may result in unintended heating away from the target site. Herein, a nano-sized (100-300 nm), dual perfluorocarbon (decafluorobutane/dodecafluoropentane) droplet that is stable, is sufficiently small to extravasate, and is convertible to micron-sized bubbles upon acoustic activation was investigated. Microbubbles and nanodroplets were incorporated into tissue-mimicking acrylamide-albumin phantoms. Microbubbles or nanodroplets at 0.1 × 10(6) per cm(3) resulted in mean lesion volumes of 80.4 ± 33.1 mm(3) and 52.8 ± 14.2 mm(3) (mean ± s.e.), respectively, after 20 s of continuous 1 MHz HIFU at a peak negative pressure of 4 MPa, compared to a lesion volume of 1.0 ± 0.8 mm(3) in agent-free control phantoms. Magnetic resonance thermometry mapping during HIFU confirmed undesired surface heating in phantoms containing microbubbles, whereas heating occurred at the acoustic focus of phantoms containing the nanodroplets. Maximal change in temperature at the target site was enhanced by 16.9% and 37.0% by microbubbles and nanodroplets, respectively. This perfluorocarbon nanodroplet has the potential to reduce the time to ablate tumors by one-third during focused ultrasound surgery while also safely enhancing thermal deposition at the target site.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Meios de Contraste / Ablação por Ultrassom Focalizado de Alta Intensidade / Fluorocarbonos / Temperatura Alta Idioma: En Ano de publicação: 2013 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Meios de Contraste / Ablação por Ultrassom Focalizado de Alta Intensidade / Fluorocarbonos / Temperatura Alta Idioma: En Ano de publicação: 2013 Tipo de documento: Article