Pressure control inverse ratio ventilation as a method to reduce peak inspiratory pressure and provide adequate ventilation and oxygenation.
Chest
; 95(5): 1081-8, 1989 May.
Article
em En
| MEDLINE
| ID: mdl-2495904
Nineteen patients with ARDS or pneumonia who were ventilated with PcIRV on the Siemens-Elema Servo 900 C were retrospectively reviewed. The PcIRV reduced peak airway pressure, PEEP, increased Paw, and improved ventilation and oxygenation in these patients. When these patients were compared with themselves on prior conventional IPPV, all had a decrease in PIP, an increase in Paw and most had a decrease in VE, with no change in PaCO2 and an increase in PaO2. The increase in Paw may have contributed to this improved arterial oxygenation. High levels of PIP and PEEP during IPPV have been identified as risk factors in the development of barotrauma and residual parenchymal pulmonary damage. We propose that PcIRV allows for adequate ventilation and oxygenation with decreases in PIP, extrinsically added PEEP and inspired O2 concentration. This mode of ventilation may decrease the morbidity associated with IPPV utilizing high PIP and PEEP.
Buscar no Google
Base de dados:
MEDLINE
Assunto principal:
Consumo de Oxigênio
/
Pneumonia
/
Respiração
/
Respiração Artificial
/
Síndrome do Desconforto Respiratório
Tipo de estudo:
Prognostic_studies
/
Risk_factors_studies
Limite:
Adolescent
/
Adult
/
Aged
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Ano de publicação:
1989
Tipo de documento:
Article