Your browser doesn't support javascript.
loading
A Handy EEG Electrode Set for patients suffering from altered mental state.
Lepola, Pasi; Myllymaa, Sami; Töyräs, Juha; Hukkanen, Taina; Mervaala, Esa; Määttä, Sara; Lappalainen, Reijo; Myllymaa, Katja.
Afiliação
  • Lepola P; Department of Clinical Neurophysiology, Kuopio University Hospital, POB 100, 70029, Kuopio, Finland. pasi.lepola@uef.fi.
  • Myllymaa S; Department of Applied Physics, University of Eastern Finland, POB 1627, 70211, Kuopio, Finland. pasi.lepola@uef.fi.
  • Töyräs J; Department of Applied Physics, University of Eastern Finland, POB 1627, 70211, Kuopio, Finland.
  • Hukkanen T; SIB Labs, University of Eastern Finland, POB 1627, 70211, Kuopio, Finland.
  • Mervaala E; Department of Clinical Neurophysiology, Kuopio University Hospital, POB 100, 70029, Kuopio, Finland.
  • Määttä S; Department of Applied Physics, University of Eastern Finland, POB 1627, 70211, Kuopio, Finland.
  • Lappalainen R; Department of Clinical Neurophysiology, Kuopio University Hospital, POB 100, 70029, Kuopio, Finland.
  • Myllymaa K; Department of Clinical Neurophysiology, Kuopio University Hospital, POB 100, 70029, Kuopio, Finland.
J Clin Monit Comput ; 29(6): 697-705, 2015 Dec.
Article em En | MEDLINE | ID: mdl-25575984
Although electroencephalography (EEG) is an important diagnostic tool for investigating patients with unexplained altered mental state (AMS), recording of emergency EEG is not a clinical routine. This is mainly due to the cumbersome electrode solutions. A Handy EEG Electrode Set consists of ten EEG, two EOG, two ground and two commutative reference hydrogel-coated silver wire electrodes attached to a thin polyester carrier film. The clinical usefulness of the Handy EEG Electrode Set was tested in 13 patients (five females, eight males) with AMS. EEG recordings were conducted at the same time with a standard 10-20 electrode set. The registration in the first patient case without the behind-ear electrodes (T9 and T10), indicated that these electrodes are very crucial to provide clinically relevant information from posterior regions of brain. In following 12 cases, the sensitivity and specificity for detecting EEG abnormality based on the Handy EEG Electrode Set recordings were 83 and 100 %, respectively. The Handy EEG Electrode Set proved to be easy to use and to provide valuable information for the neurophysiological evaluation of a patient suffering from AMS. However, further studies with larger number of patients are warranted to clarify the true diagnostic accuracy and applicability of this approach.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Transtornos da Consciência / Eletrodos / Eletroencefalografia Tipo de estudo: Diagnostic_studies / Evaluation_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Transtornos da Consciência / Eletrodos / Eletroencefalografia Tipo de estudo: Diagnostic_studies / Evaluation_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2015 Tipo de documento: Article