Your browser doesn't support javascript.
loading
Outcomes of unconventional utilization of BI-RADS category 3 assessment at opportunistic screening.
Altas, Hilal; Tureli, Derya; Cengic, Ismet; Kucukkaya, Fikret; Aribal, Erkin; Kaya, Handan.
Afiliação
  • Altas H; 1 Department of Radiology, Ercis State Hospital, Turkey.
  • Tureli D; 1 Department of Radiology, Ercis State Hospital, Turkey.
  • Cengic I; 2 Department of Radiology, Van Bolge Research and Education Hospital, Turkey.
  • Kucukkaya F; 3 Department of Radiology, Marmara University School of Medicine, Turkey.
  • Aribal E; 3 Department of Radiology, Marmara University School of Medicine, Turkey.
  • Kaya H; 4 Department of Pathology, Marmara University School of Medicine, Turkey.
Acta Radiol ; 57(11): 1304-1309, 2016 Nov.
Article em En | MEDLINE | ID: mdl-26019241
ABSTRACT
Background An important difficulty regarding the Breast Imaging Reporting and Data System (BI-RADS) category 3 assessment is the need for extensive diagnostic workup and an additional 6-month follow-up study. Purpose To evaluate the feasibility of the BI-RADS category 3 assessments at opportunistic screening. Material and Methods Mammography charts of 9062 screening patients in a major teaching hospital situated in an urban setting of a developing country were evaluated retrospectively (1997-2010). BI-RADS category 3 patients, called for a 6-month follow-up, which comprised a single-view spot or magnification mammogram. The length of follow-up period, compliance to periodic mammographic surveillance, cancer detection rate, and negative predictive values of category 3 assessments were calculated. Results Of the screened population, 9.2% were assigned BI-RADS category 3, and 31.2% of these cases were lost to follow-up. The mean follow-up period for 606 patients was 36.9 months. The negative predictive values for 6-month, 12-month, and final control studies were 90.9%, 87.5%, and 100%, respectively. Patient compliance for 6 months, 12 months, and any control evaluations beyond 12 months was low (50.0%, 29.8%, and 47.5%, respectively). Cancer detection rate was 0.8%. Conclusion Results of the study supports the feasibility of the BI-RADS category 3 assessments at opportunistic screening without any additional diagnostic workup. The practice of category 3 assessment following screening mammograms may be a more cost-effective method for developing countries with high recall rates and low resources in eliminating the maximum risk with minimum cost within the limits of available resources.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Mamografia / Competência Clínica / Países em Desenvolvimento / Detecção Precoce de Câncer Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies / Screening_studies Limite: Adult / Aged / Aged80 / Female / Humans / Middle aged País/Região como assunto: Asia Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Mamografia / Competência Clínica / Países em Desenvolvimento / Detecção Precoce de Câncer Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies / Screening_studies Limite: Adult / Aged / Aged80 / Female / Humans / Middle aged País/Região como assunto: Asia Idioma: En Ano de publicação: 2016 Tipo de documento: Article