Your browser doesn't support javascript.
loading
Validation of a liquid chromatography-high-resolution mass spectrometry method for the analysis of ceftiofur in poultry muscle, kidneys and plasma: A unique accuracy profile for each and every matrix.
Mompelat, Sophie; Fourmond, Marie-Pierre; Laurentie, Michel; Verdon, Eric; Hurtaud-Pessel, Dominique; Abjean, Jean-Pierre.
Afiliação
  • Mompelat S; French Agency for Food, Environmental and Occupational Health & Safety, Laboratory of Fougères, European Union Reference Laboratory for Residues of Antimicrobial Veterinary Medicinal Products in Food from Animal Origin, 10B rue Claude Bourgelat, Bioagropolis, Javené, F-35306 Fougères, France.
  • Fourmond MP; French Agency for Food, Environmental and Occupational Health & Safety, Laboratory of Fougères, European Union Reference Laboratory for Residues of Antimicrobial Veterinary Medicinal Products in Food from Animal Origin, 10B rue Claude Bourgelat, Bioagropolis, Javené, F-35306 Fougères, France.
  • Laurentie M; French Agency for Food, Environmental and Occupational Health & Safety, Laboratory of Fougères, European Union Reference Laboratory for Residues of Antimicrobial Veterinary Medicinal Products in Food from Animal Origin, 10B rue Claude Bourgelat, Bioagropolis, Javené, F-35306 Fougères, France.
  • Verdon E; French Agency for Food, Environmental and Occupational Health & Safety, Laboratory of Fougères, European Union Reference Laboratory for Residues of Antimicrobial Veterinary Medicinal Products in Food from Animal Origin, 10B rue Claude Bourgelat, Bioagropolis, Javené, F-35306 Fougères, France.
  • Hurtaud-Pessel D; French Agency for Food, Environmental and Occupational Health & Safety, Laboratory of Fougères, European Union Reference Laboratory for Residues of Antimicrobial Veterinary Medicinal Products in Food from Animal Origin, 10B rue Claude Bourgelat, Bioagropolis, Javené, F-35306 Fougères, France. El
  • Abjean JP; French Agency for Food, Environmental and Occupational Health & Safety, Laboratory of Fougères, European Union Reference Laboratory for Residues of Antimicrobial Veterinary Medicinal Products in Food from Animal Origin, 10B rue Claude Bourgelat, Bioagropolis, Javené, F-35306 Fougères, France.
J Chromatogr A ; 1407: 119-29, 2015 Aug 14.
Article em En | MEDLINE | ID: mdl-26152526
ABSTRACT
A robust, selective and specific liquid chromatography-high resolution mass spectrometry (LC-HRMS) method was developed for the quantification of total residues of ceftiofur, an antibiotic belonging to the 3rd generation cephalosporins in plasma, muscle and kidney of poultry. Ceftiofur and conjugates in samples were firstly hydrolyzed with dithioerythritol into desfuroylceftiofur, which was then stabilized by derivatization with iodoacetamide into desfuroylceftiofur acetamide. Sample were then submitted to a solid phase extraction followed the accurate mass analysis of desfuroylceftiofur acetamide by LC-HRMS in full scan mode using a linear trap quadrupole (LTQ)-Orbitrap mass spectrometer with a resolving power 60,000 full width at half maximum (FWHM). The method was fully validated over a dosing range between 100 and 2000 µg kg(-1) (or µg L(-1)) using the total error approach. Accuracy profiles a graphical decision-making tool were built by computing results of validation procedure with acceptance limits set at ±60%, and ß-expectation tolerance intervals, i.e. the interval assuming to contain a ß % of future measurements (ß=90% in this study). Total measurement error including trueness, repeatability and intermediate precision were evaluated. Relative bias of trueness was never exceeding the threshold of 6% in all matrices at all level of concentration. The mean relative standard deviation for repeatability was lower than 16% at all levels of concentration for all matrices; the mean relative standard deviation for intermediate precision was lower than 25% at all levels of concentration for all matrices. This validation approach proved that the method is reliable for the quantification in each and every matrix (i.e. plasma, kidneys and muscle of chicken) thanks to only one single regression model (i.e. linear) obtained from external calibration standards (without matrix) with deuterated labelled internal standard. The developed method was applied during a depletion study of ceftiofur in chicken tissues and plasma.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Espectrometria de Massas / Análise Química do Sangue / Cefalosporinas / Cromatografia Líquida / Tecnologia de Alimentos / Carne / Músculos Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Espectrometria de Massas / Análise Química do Sangue / Cefalosporinas / Cromatografia Líquida / Tecnologia de Alimentos / Carne / Músculos Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Ano de publicação: 2015 Tipo de documento: Article