Your browser doesn't support javascript.
loading
Effectiveness of the haemonetics MCS cell separator in the collection of apheresis platelets.
Keklik, Muzaffer; Keklik, Ertugrul; Korkmaz, Serdal; Aygun, Bilal; Arik, Ferhat; Kilic, Ozcan; Sarikoc, Murat.
Afiliação
  • Keklik M; Department of Hematology, Kayseri Education and Research Hospital, Kayseri, Turkey. Electronic address: muzafferkeklik@yahoo.com.
  • Keklik E; Department of Physiology, Faculty of Medicine, Erciyes University, Kayseri, Turkey.
  • Korkmaz S; Department of Hematology, Kayseri Education and Research Hospital, Kayseri, Turkey.
  • Aygun B; Department of Hematology, Kayseri Education and Research Hospital, Kayseri, Turkey.
  • Arik F; Department of Internal Medicine, Kayseri Education and Research Hospital, Kayseri, Turkey.
  • Kilic O; Department of Internal Medicine, Kayseri Education and Research Hospital, Kayseri, Turkey.
  • Sarikoc M; Apheresis Unit, Kayseri Education and Research Hospital, Kayseri, Turkey.
Transfus Apher Sci ; 53(3): 396-8, 2015 Dec.
Article em En | MEDLINE | ID: mdl-26283175
ABSTRACT
Platelet (PLT) transfusions play an important role in patients with thrombocytopenia or severely impaired platelet function. Platelet concentrates are prepared from whole-blood donations or by plateletpheresis. In recent years, different instruments have been developed to perform plateletpheresis. We evaluated an apheresis instrument, the Haemonetics MCS(®) + with regard to PLT yield, collection efficiency (CE), and collection rate (CR) in a retrospective, randomized study in 526 donors. In this system, we used leukoreduction filters post collection to obtain leukoreduced products. The Haemonetics MCS(®) + cell separator efficiently collected apheresis platelets with median PLT yields of 3.7 × 10(11), mean CE of 66.69 ± 13.73% and mean CR of 0.063 ± 0.013 × 10(11)/min. The median blood volume processed was 3290 (2420-4370) ml, and the median volume of acid citrate dextrose-A (ACD-A) used in collections on the device was 385 (196-517) ml. Also, this device allowed the collection of white blood cell (WBC) reduced plateletpheresis with mean 0.07 ± 0.15 × 10(6) WBC content. No serious donor or recipient reactions occurred.