Your browser doesn't support javascript.
loading
Inter-observer variation and diagnostic efficacy of apparent diffusion coefficient (ADC) measurements obtained by diffusion-weighted imaging (DWI) in small renal masses.
Ponhold, Lothar; Javor, Domagoj; Heinz-Peer, Gertraud; Sevcenco, Sabina; Hofstetter, Martin; Baltzer, Pascal Andreas.
Afiliação
  • Ponhold L; Department of Radiology, University Hospital of Sankt-Pölten, St. Pölten, Austria.
  • Javor D; Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria.
  • Heinz-Peer G; Department of Radiology, University Hospital of Sankt-Pölten, St. Pölten, Austria.
  • Sevcenco S; Department of Urology, Medical University of Vienna, Vienna, Austria.
  • Hofstetter M; Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria.
  • Baltzer PA; Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria pascal.baltzer@meduniwien.ac.at.
Acta Radiol ; 57(8): 1014-20, 2016 Aug.
Article em En | MEDLINE | ID: mdl-26486599
ABSTRACT

BACKGROUND:

Diffusion-weighted imaging (DWI) is increasingly used to diagnose renal lesion subtypes. Especially in small renal masses, identification of less aggressive tumor types is of clinical interest, as active surveillance strategies can be applied.

PURPOSE:

To evaluate the inter-observer variation and diagnostic efficacy of apparent diffusion coefficient (ADC) measurements obtained by DWI in small renal masses ≤4 cm (SRM). MATERIAL AND

METHODS:

This retrospective IRB-approved study included 39 patients (46 SRM 12 benign, 34 malignant). All underwent a 3 T DWI of SRM prior to surgery. Two radiologists independently analyzed all imaging data by three measurements. Limits of agreement, intraclass correlation coefficients (ICC), group comparisons by t-tests, and ROC analysis were performed.

RESULTS:

Reliability of ADC measurements was very high with an ICC of >0.9 for both observers. Inter-rater reliability was high with an ICC of 0.82. Limits of agreement for average ADC values between both observers were -23.5% to 38.3% with a mean difference of 7.5% between both observers. No significant differences were found between benign and malignant lesions (P value Observer 1 0.362, Observer 2 0.622). Papillary carcinoma showed lower ADC values compared to non-papillary carcinoma (P value Observer 1 0.008, Observer 2 0.012). Consequently, ROC analysis revealed a significant (P < 0.001, respectively) area under the ROC curve of 0.853 (Observer 1) and 0.837 (Observer 2) without significant differences between both readers (P = 0.772).

CONCLUSION:

ADC measurements of SRM at 3 T show a high reproducibility and differentiate papillary from non-papillary carcinoma subtypes. However, measurement variability may limit the application of fixed ADC thresholds for lesion diagnosis.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imagem de Difusão por Ressonância Magnética / Neoplasias Renais Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imagem de Difusão por Ressonância Magnética / Neoplasias Renais Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2016 Tipo de documento: Article