Limitations and difficulties of echocardiographic short-axis assessment of paravalvular leakage after corevalve transcatheter aortic valve implantation.
Cardiovasc Ultrasound
; 14(1): 37, 2016 Sep 06.
Article
em En
| MEDLINE
| ID: mdl-27600600
ABSTRACT
To make assessment of paravalvular aortic leakage (PVL) after transcatheter aortic valve implantation (TAVI) more uniform the second Valve Academic Research Consortium (VARC) recently updated the echocardiographic criteria for mild, moderate and severe PVL. In the VARC recommendation the assessment of the circumferential extent of PVL in the short-axis view is considered critical. In this paper we will discuss our observational data on the limitations and difficulties of this particular view, that may potentially result in overestimation or underestimation of PVL severity.