Volatile Organic Compounds Sensing Using Optical Fibre Long Period Grating with Mesoporous Nano-Scale Coating.
Hromadka, Jiri; Korposh, Sergiy; Partridge, Matthew; James, Stephen W; Davis, Frank; Crump, Derrick; Tatam, Ralph P.
Afiliação
  • Hromadka J; Optics and Photonics Group, Faculty of Engineering, University of Nottingham, University Park, Nottingham NG7 2RD, UK. Jiri.Hromadka@nottingham.ac.uk.
  • Korposh S; Institute for Environmental Studies, Charles University in Prague, Benatska 2, Prague 2 CZ-128 01, Czech Republic. Jiri.Hromadka@nottingham.ac.uk.
  • Partridge M; Optics and Photonics Group, Faculty of Engineering, University of Nottingham, University Park, Nottingham NG7 2RD, UK. s.korposh@nottingham.ac.uk.
  • James SW; Centre for Engineering Photonics, Cranfield University, Cranfield, Bedfordshire MK43 0AL, UK. s.korposh@nottingham.ac.uk.
  • Davis F; Centre for Engineering Photonics, Cranfield University, Cranfield, Bedfordshire MK43 0AL, UK. m.c.partridge@cranfield.ac.uk.
  • Crump D; Centre for Engineering Photonics, Cranfield University, Cranfield, Bedfordshire MK43 0AL, UK. s.w.james@cranfield.ac.uk.
  • Tatam RP; Department of Engineering and Applied Design, University of Chichester Bognor Regis, West Sussex PO21 1HR, UK. F.Davis@chi.ac.uk.
Sensors (Basel) ; 17(2)2017 Feb 08.
Article em En | MEDLINE | ID: mdl-28208691
ABSTRACT
A long period grating (LPG) modified with a mesoporous film infused with a calixarene as a functional compound was employed for the detection of individual volatile organic compounds (VOCs) and their mixtures. The mesoporous film consisted of an inorganic part, SiO2 nanoparticles (NPs), along with an organic moiety of poly(allylamine hydrochloride) polycation PAH, which was finally infused with the functional compound, p-sulphanato calix[4]arene (CA[4]) or p-sulphanato calix[8]arene (CA[8]). The LPG sensor was designed to operate at the phase matching turning point to provide the highest sensitivity. The sensing mechanism is based on the measurement of the refractive index (RI) change induced by a complex of the VOCs with calixarene. The LPG, modified with a coating of 5 cycles of (SiO2 NPs/PAH) and infused with CA[4] or CA[8], was exposed to chloroform, benzene, toluene and acetone vapours. The British Standards test of the VOCs emissions from material (BS EN ISO 16000-92006) was used to test the LPG sensor performance.