Your browser doesn't support javascript.
loading
Effectiveness of XP-endo Finisher and XP-endo Finisher R in removing root filling remnants: a micro-CT study.
Silva, E J N L; Belladonna, F G; Zuolo, A S; Rodrigues, E; Ehrhardt, I C; Souza, E M; De-Deus, G.
Afiliação
  • Silva EJNL; Department of Endodontics, Grande Rio University, Duque de Caxias, Rio de Janeiro, Brazil.
  • Belladonna FG; Department of Endodontics, Rio de Janeiro State University, Rio de Janeiro, Brazil.
  • Zuolo AS; Department of Endodontics, Fluminense Federal University, Niterói, Rio de Janeiro, Brazil.
  • Rodrigues E; Department of Endodontics, Fluminense Federal University, Niterói, Rio de Janeiro, Brazil.
  • Ehrhardt IC; Department of Endodontics, Fluminense Federal University, Niterói, Rio de Janeiro, Brazil.
  • Souza EM; Department of Endodontics, Fluminense Federal University, Niterói, Rio de Janeiro, Brazil.
  • De-Deus G; Department of Dentistry II, Federal University of Maranhão, São Luís, Maranhão, Brazil.
Int Endod J ; 51(1): 86-91, 2018 Jan.
Article em En | MEDLINE | ID: mdl-28467618
ABSTRACT

AIM:

To evaluate the efficacy of filling material removal from oval-shaped canals after the use of supplementary files (XP-endo Finisher and XP-endo Finisher R) through microcomputed tomographic (micro-CT) analysis.

METHODOLOGY:

The root canals of twenty maxillary single-rooted teeth were prepared with Reciproc R25 files and filled with gutta-percha and AH Plus sealer using the continuous wave of condensation technique. The root canals were then retreated using Reciproc R25 and R40 instruments. After this, the specimens were assigned to two groups according to the supplementary cleaning approach, using XP-endo Finisher and XP-endo Finisher R. The surface area and volume of removed filling material was assessed using micro-CT imaging before and after the use of the XP-endo instruments. Data were analysed statistically with a significance level of 5%.

RESULTS:

Removal of filling material at 66.8% and 59.4% in volume and 67.3% and 61.4% in surface area was seen for the XP-endo Finisher and the XP-endo Finisher R files, respectively. The amount of filling material removed by both supplementary files was highly significant (P = 0.000). No significant difference in the percentage of removed filling material was detected for the XP-endo instruments (P = 0.636 for volume and P = 0.667 for surface area).

CONCLUSIONS:

Both XP-endo files were equally effective in the removal of remaining filling material from straight oval-shaped canals. None of the instruments were able to remove all the residual filling material.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Obturação do Canal Radicular / Instrumentos Odontológicos / Cavidade Pulpar Tipo de estudo: Evaluation_studies Limite: Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Obturação do Canal Radicular / Instrumentos Odontológicos / Cavidade Pulpar Tipo de estudo: Evaluation_studies Limite: Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article