Your browser doesn't support javascript.
loading
Nanofocusing with aberration-corrected rotationally parabolic refractive X-ray lenses.
Seiboth, Frank; Wittwer, Felix; Scholz, Maria; Kahnt, Maik; Seyrich, Martin; Schropp, Andreas; Wagner, Ulrich; Rau, Christoph; Garrevoet, Jan; Falkenberg, Gerald; Schroer, Christian G.
Afiliação
  • Seiboth F; Deutsches Elektronen-Synchrotron - DESY, Notkestrasse 85, 22607 Hamburg, Germany.
  • Wittwer F; Deutsches Elektronen-Synchrotron - DESY, Notkestrasse 85, 22607 Hamburg, Germany.
  • Scholz M; Deutsches Elektronen-Synchrotron - DESY, Notkestrasse 85, 22607 Hamburg, Germany.
  • Kahnt M; Deutsches Elektronen-Synchrotron - DESY, Notkestrasse 85, 22607 Hamburg, Germany.
  • Seyrich M; Deutsches Elektronen-Synchrotron - DESY, Notkestrasse 85, 22607 Hamburg, Germany.
  • Schropp A; Deutsches Elektronen-Synchrotron - DESY, Notkestrasse 85, 22607 Hamburg, Germany.
  • Wagner U; Diamond Light Source Ltd, Diamond House, Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE, UK.
  • Rau C; Diamond Light Source Ltd, Diamond House, Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE, UK.
  • Garrevoet J; Deutsches Elektronen-Synchrotron - DESY, Notkestrasse 85, 22607 Hamburg, Germany.
  • Falkenberg G; Deutsches Elektronen-Synchrotron - DESY, Notkestrasse 85, 22607 Hamburg, Germany.
  • Schroer CG; Deutsches Elektronen-Synchrotron - DESY, Notkestrasse 85, 22607 Hamburg, Germany.
J Synchrotron Radiat ; 25(Pt 1): 108-115, 2018 Jan 01.
Article em En | MEDLINE | ID: mdl-29271759
ABSTRACT
Wavefront errors of rotationally parabolic refractive X-ray lenses made of beryllium (Be CRLs) have been recovered for various lens sets and X-ray beam configurations. Due to manufacturing via an embossing process, aberrations of individual lenses within the investigated ensemble are very similar. By deriving a mean single-lens deformation for the ensemble, aberrations of any arbitrary lens stack can be predicted from the ensemble with \bar{\sigma} = 0.034λ. Using these findings the expected focusing performance of current Be CRLs are modeled for relevant X-ray energies and bandwidths and it is shown that a correction of aberrations can be realised without prior lens characterization but simply based on the derived lens deformation. The performance of aberration-corrected Be CRLs is discussed and the applicability of aberration-correction demonstrated over wide X-ray energy ranges.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2018 Tipo de documento: Article