Your browser doesn't support javascript.
loading
Diagnostic Performance of the Simultaneous Acquisition Rest 99 mTc-Tetrofosmin/Stress 201Tl Dual-Isotope Protocol With a Semiconductor Camera - Comparison With the Rest-Stress 99 mTc-Tetrofosmin Protocol.
Kawamura, Itta; Kajiura, Ryo; Motoji, Yusuke; Okamoto, Syuichi; Tanigaki, Toru; Omori, Hiroyuki; Hirata, Tetsuo; Kikuchi, Jun; Ota, Hideaki; Sobue, Yoshihiro; Miyake, Taiji; Tsunekawa, Tomohiro; Kato, Takayoshi; Kawase, Yoshiaki; Okubo, Munenori; Kamiya, Hiroki; Tsuchiya, Kunihiko; Tomita, Shinji; Hirakawa, Akihiro; Kondo, Takeshi; Suzuki, Takahiko; Matsuo, Hitoshi.
Afiliação
  • Kawamura I; Gifu Heart Center.
  • Kajiura R; Gifu Heart Center.
  • Motoji Y; Gifu Heart Center.
  • Okamoto S; Gifu Heart Center.
  • Tanigaki T; Gifu Heart Center.
  • Omori H; Gifu Heart Center.
  • Hirata T; Gifu Heart Center.
  • Kikuchi J; Gifu Heart Center.
  • Ota H; Gifu Heart Center.
  • Sobue Y; Gifu Heart Center.
  • Miyake T; Gifu Heart Center.
  • Tsunekawa T; Gifu Heart Center.
  • Kato T; Gifu Heart Center.
  • Kawase Y; Gifu Heart Center.
  • Okubo M; Gifu Heart Center.
  • Kamiya H; Gifu Heart Center.
  • Tsuchiya K; Gifu Heart Center.
  • Tomita S; Gifu Heart Center.
  • Hirakawa A; Department of Biostatistics and Bioinformatics, Graduate School of Medicine, The University of Tokyo.
  • Kondo T; Gifu Heart Center.
  • Suzuki T; Gifu Heart Center.
  • Matsuo H; Gifu Heart Center.
Circ J ; 82(11): 2837-2844, 2018 10 25.
Article em En | MEDLINE | ID: mdl-30175800
ABSTRACT

BACKGROUND:

This study compared the diagnostic value of myocardial perfusion imaging (MPI) between the rest-stress 99 mTc-tetrofosmin protocol (Tc/Tc protocol) and simultaneous acquisition rest 99 mTc-tetrofosmin/stress 201Tl dual-isotope protocol (SDI protocol) with a semiconductor camera.Methods and 

Results:

We retrospectively studied 147 patients who underwent stress MPI using a cadmium-zinc-telluride camera and invasive coronary angiography within a 3-month interval. The Tc/Tc and SDI protocols were used in 59 and 88 patients, respectively. The sensitivity, specificity, and accuracy of the summed difference score in per-patient analysis were 56%, 85%, and 69%, respectively, for the Tc/Tc protocol and 89%, 82%, and 85%, respectively, for the SDI protocol. The area under the receiver operating characteristic curve was significantly better for the SDI than Tc/Tc protocol for the left anterior descending artery (0.836 vs. 0.674; P=0.0380), the left circumflex artery (0.754 vs. 0.599; P=0.0441), and in per-patient analysis (0.875 vs. 0.707; P=0.0135). There was no significant difference in the diagnostic accuracy of the summed stress score for any vessel or in per-patient analysis between the 2 protocols.

CONCLUSIONS:

The SDI protocol had a higher diagnostic accuracy for the detection of coronary ischemia than the Tc/Tc protocol.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Compostos Organofosforados / Radioisótopos de Tálio / Compostos de Organotecnécio / Tomografia Computadorizada de Emissão de Fóton Único / Angiografia Coronária / Isquemia Miocárdica / Imagem de Perfusão do Miocárdio Tipo de estudo: Diagnostic_studies / Guideline / Observational_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Compostos Organofosforados / Radioisótopos de Tálio / Compostos de Organotecnécio / Tomografia Computadorizada de Emissão de Fóton Único / Angiografia Coronária / Isquemia Miocárdica / Imagem de Perfusão do Miocárdio Tipo de estudo: Diagnostic_studies / Guideline / Observational_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article