Your browser doesn't support javascript.
loading
Vasculotide, an angiopoietin-1 mimetic, reduces pulmonary vascular leakage and preserves microcirculatory perfusion during cardiopulmonary bypass in rats.
Dekker, N A M; van Meurs, M; van Leeuwen, A L I; Hofland, H M; van Slyke, P; Vonk, A B A; Boer, C; van den Brom, C E.
Afiliação
  • Dekker NAM; Department of Anaesthesiology, Experimental Laboratory for Vital Signs, Amsterdam Cardiovascular Sciences, VU University Medical Center, Amsterdam, The Netherlands; Department of Cardiothoracic Surgery and Amsterdam Cardiovascular Sciences, VU University Medical Center, Amsterdam, The Netherlands; D
  • van Meurs M; Department of Pathology and Medical Biology, University Medical Center Groningen, Groningen, The Netherlands; Department of Critical Care Medicine, University Medical Center Groningen, Groningen, The Netherlands.
  • van Leeuwen ALI; Department of Anaesthesiology, Experimental Laboratory for Vital Signs, Amsterdam Cardiovascular Sciences, VU University Medical Center, Amsterdam, The Netherlands; Department of Cardiothoracic Surgery and Amsterdam Cardiovascular Sciences, VU University Medical Center, Amsterdam, The Netherlands; D
  • Hofland HM; Department of Anaesthesiology, Experimental Laboratory for Vital Signs, Amsterdam Cardiovascular Sciences, VU University Medical Center, Amsterdam, The Netherlands; Department of Physiology, Amsterdam Cardiovascular Sciences, VU University Medical Center, Amsterdam, The Netherlands.
  • van Slyke P; Vasomune Therapeutics, Toronto, ON, Canada.
  • Vonk ABA; Department of Cardiothoracic Surgery and Amsterdam Cardiovascular Sciences, VU University Medical Center, Amsterdam, The Netherlands.
  • Boer C; Department of Anaesthesiology, Experimental Laboratory for Vital Signs, Amsterdam Cardiovascular Sciences, VU University Medical Center, Amsterdam, The Netherlands.
  • van den Brom CE; Department of Anaesthesiology, Experimental Laboratory for Vital Signs, Amsterdam Cardiovascular Sciences, VU University Medical Center, Amsterdam, The Netherlands; Department of Physiology, Amsterdam Cardiovascular Sciences, VU University Medical Center, Amsterdam, The Netherlands. Electronic addre
Br J Anaesth ; 121(5): 1041-1051, 2018 Nov.
Article em En | MEDLINE | ID: mdl-30336848
BACKGROUND: Cardiopulmonary bypass (CPB) during cardiac surgery impairs microcirculatory perfusion and is paralleled by vascular leakage. The endothelial angiopoietin/Tie2 system controls microvascular leakage. This study investigated whether targeting Tie2 with the angiopoietin-1 mimetic vasculotide reduces vascular leakage and preserves microcirculatory perfusion in a rat CPB model. METHODS: Rats were subjected to 75 min of CPB after treatment with vasculotide or phosphate buffered solution as control or underwent a sham procedure. Microcirculatory perfusion and leakage were assessed with intravital microscopy (n=10 per group) and Evans blue dye extravasation (n=13 per group), respectively. Angiopoietin-1, -2, and Tie2 protein and gene expression were determined in plasma, kidney, and lung. RESULTS: CPB immediately impaired microcirculatory perfusion [5 (4-8) vs 10 (7-12) vessels per recording, P=0.002] in untreated CPB rats compared with sham, which persisted after weaning from CPB. CPB increased circulating angiopoeietin-1, -2, and soluble Tie2 concentrations and reduced Tie2 messenger ribonucleic acid (mRNA) expression in kidney and lung. Moreover, CPB increased Evans blue dye leakage in kidney [12 (8-25) vs 7 (1-12) µg g-1, P=0.04] and lung [and 23 (13-60) vs 6 (4-16) µg g-1, P=0.001] compared with sham. Vasculotide treatment preserved microcirculatory perfusion during and after CPB. Moreover, vasculotide treatment reduced Evans blue dye extravasation in lung compared with CPB control [18 (6-28) µg g-1vs 23 (13-60) µg g-1, P=0.04], but not in kidney [10 (3-23) vs 12 (8-25) µg g-1, P=0.38]. Vasculotide did not affect circulating or mRNA expression of angiopoietin-1, -2, and Tie2 concentrations compared with untreated CPB controls. CONCLUSIONS: Treatment with the angiopoietin-1 mimetic vasculotide reduced pulmonary vascular leakage and preserved microcirculatory perfusion during CPB in a rat model.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fragmentos de Peptídeos / Ponte Cardiopulmonar / Circulação Pulmonar / Angiopoietina-1 Limite: Animals Idioma: En Ano de publicação: 2018 Tipo de documento: Article