Your browser doesn't support javascript.
loading
Stress Evolution during Ge Nanoparticles Growth in a SiO2 Matrix.
Pivac, Branko; Dubcek, Pavo; Dasovic, Jasna; Popovic, Jasminka; Radic, Nikola; Bernstorff, Sigrid; Zavasnik, Janez; Vlahovic, Branislav.
Afiliação
  • Pivac B; Materials Physics , R. Boskovic Institute , Bijenicka 54 , Zagreb 10000 , Croatia.
  • Dubcek P; Materials Physics , R. Boskovic Institute , Bijenicka 54 , Zagreb 10000 , Croatia.
  • Dasovic J; Materials Physics , R. Boskovic Institute , Bijenicka 54 , Zagreb 10000 , Croatia.
  • Popovic J; Materials Physics , R. Boskovic Institute , Bijenicka 54 , Zagreb 10000 , Croatia.
  • Radic N; Materials Physics , R. Boskovic Institute , Bijenicka 54 , Zagreb 10000 , Croatia.
  • Bernstorff S; Elettra-Sincrotrone Trieste , SS 14, Km 163.5, in AREA Science Park , Basovizza 34149 , Trieste , Italy.
  • Zavasnik J; Jozef Stefan Institute , Jamova Cesta 39 , Ljubljana 1000 , Slovenia.
  • Vlahovic B; Max-Planck-Institut für Eisenforschung GmbH , Max-Planck-Straße 1 , Düsseldorf 40237 , Germany.
Inorg Chem ; 57(23): 14939-14952, 2018 Dec 03.
Article em En | MEDLINE | ID: mdl-30427673
ABSTRACT
Superstructures are explored that were obtained by multilayer magnetron deposition at room temperature of 20 SiO2 and SiO2Ge bilayers, each 2 × 4 nm thick, and subsequently annealed in inert N2 atmosphere at different temperatures in the range of 500-750 °C. The structural and optical changes induced by annealing and the formation and growth of Ge nanoparticles (nps) from early clusters to their full growth and final dissolution were studied by the simultaneous grazing-incidence small- and wide-angle X-ray scattering, transmission electron microscopy, and (time-resolved) photoluminescence (PL). It is shown that in as-deposited multilayers aggregation of small clusters already occurred, and the clusters were reasonably well intercorrelated in the lateral plane. During annealing at Ta = 550 °C or higher temperatures, Ge nps start to form and remain partly amorphous at lower Ta but crystallize completely at about 600 °C. At even higher temperatures, the Ge nps dissolve and Ge diffuses out almost completely, leaving voids in the SiO2 matrix. Visible PL from the samples was detected and attributed to defects in the nps/matrix interface layers rather than to the nps itself because PL persisted even after Ge nps dissolution.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2018 Tipo de documento: Article