Assessment using CFD of the wind direction on the air discharges caused by natural ventilation of a poultry house.
Rojano, Fernando; Bournet, Pierre-Emmanuel; Hassouna, Melynda; Robin, Paul; Kacira, Murat; Choi, Christopher Y.
Afiliação
  • Rojano F; INECOL, Instituto de Ecología, A. C, El Haya, Camino Antiguo a Coatepec 351, 91070, Xalapa, Mexico. fernando.rojano@wvstateu.edu.
  • Bournet PE; EPHor, Environmental Physics and Horticulture Research Unit, Agrocampus Ouest, Centre d'Angers, 2, rue Le Nôtre, 49045, Angers, France.
  • Hassouna M; SAS Lab, INRA 65 Rue de Saint-Brieuc, 35042, Rennes, France.
  • Robin P; SAS Lab, INRA 65 Rue de Saint-Brieuc, 35042, Rennes, France.
  • Kacira M; Agricultural and Biosystems Engineering, The University of Arizona, Tucson, AZ, 85721, USA.
  • Choi CY; Biological Systems Engineering, University of Wisconsin, Madison, WI, 53706, USA.
Environ Monit Assess ; 190(12): 724, 2018 Nov 14.
Article em En | MEDLINE | ID: mdl-30430268
Air inside poultry houses must be removed on a regular basis to prevent excess of heat, particles and noxious gases that can imperil animals. To cope with this issue, natural ventilation could be an effective method when assisted by accurate predictions. This study investigates air discharges caused by natural ventilation of a poultry house by means of a three-dimensional computational fluid dynamics (CFD) model. It solves the governing equations of momentum, heat and mass transport, radiative transfers and animal-generated heat. Wind directions of 0°, 36° and 56° (0° corresponds to a wind blowing perpendicular to the ridgeline) were investigated; the CFD model predictions achieved a RMSE of 1.2 °C and 0.6 g[H2O] kg-1 [dry air] for internal temperature and absolute humidity, respectively, when air blew with an angle of 36°. Air renewal rates (ARR) were 39.5 (± 1.9), 34.9 (± 2.2) and 33.6 (± 1.7) volumes of the building per hour, when air blew at 0°, 36° and 56°, respectively. Such ARR predictions served to know how the gases contained in air would likely spread downstream from the building in order to define regions of potentially high gas concentration that could endanger neighbouring habitable facilities.