Your browser doesn't support javascript.
loading
Evaluation of a newly developed 2D parametric parenchymal blood flow technique with an automated vessel suppression algorithm in patients with chronic thromboembolic pulmonary hypertension undergoing balloon pulmonary angioplasty.
Maschke, S K; Winther, H M B; Meine, T; Werncke, T; Olsson, K M; Hoeper, M M; Baumgart, J; Wacker, F K; Meyer, B C; Renne, J; Hinrichs, J B.
Afiliação
  • Maschke SK; Department of Diagnostic and Interventional Radiology, Member of the German Center for Lung Research (DZL), Hannover Medical School, Hannover, Germany.
  • Winther HMB; Department of Diagnostic and Interventional Radiology, Member of the German Center for Lung Research (DZL), Hannover Medical School, Hannover, Germany.
  • Meine T; Department of Diagnostic and Interventional Radiology, Member of the German Center for Lung Research (DZL), Hannover Medical School, Hannover, Germany.
  • Werncke T; Department of Diagnostic and Interventional Radiology, Member of the German Center for Lung Research (DZL), Hannover Medical School, Hannover, Germany.
  • Olsson KM; Clinic for Pneumology, Member of the German Center for Lung Research (DZL), Hannover Medical School, Hannover, Germany.
  • Hoeper MM; Clinic for Pneumology, Member of the German Center for Lung Research (DZL), Hannover Medical School, Hannover, Germany.
  • Baumgart J; Siemens Medical Solutions USA, Inc., Angiography, Fluoroscopic and Radiographic Systems, Hoffman Estates, IL, USA.
  • Wacker FK; Department of Diagnostic and Interventional Radiology, Member of the German Center for Lung Research (DZL), Hannover Medical School, Hannover, Germany.
  • Meyer BC; Department of Diagnostic and Interventional Radiology, Member of the German Center for Lung Research (DZL), Hannover Medical School, Hannover, Germany.
  • Renne J; Department of Diagnostic and Interventional Radiology, Member of the German Center for Lung Research (DZL), Hannover Medical School, Hannover, Germany.
  • Hinrichs JB; Department of Diagnostic and Interventional Radiology, Member of the German Center for Lung Research (DZL), Hannover Medical School, Hannover, Germany. Electronic address: hinrichs.jan@mh-hannover.de.
Clin Radiol ; 74(6): 437-444, 2019 06.
Article em En | MEDLINE | ID: mdl-30890260

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Interpretação de Imagem Assistida por Computador / Angiografia Digital / Angioplastia com Balão / Hipertensão Pulmonar Tipo de estudo: Observational_studies / Prognostic_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Interpretação de Imagem Assistida por Computador / Angiografia Digital / Angioplastia com Balão / Hipertensão Pulmonar Tipo de estudo: Observational_studies / Prognostic_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2019 Tipo de documento: Article