Your browser doesn't support javascript.
loading
Simple and green synthesis of carbon dots (CDs) from valerian root and application of modified mesoporous boehmite (AlOOH) with CDs as a fluorescence probe for determination of imipramine.
Sobhani, Reyhaneh; Rezaei, Behzad; Shahshahanipour, Marzieh; Ensafi, Ali A; Mohammadnezhad, Gholamhossein.
Afiliação
  • Sobhani R; Department of Chemistry, Isfahan University of Technology, Isfahan, 84156-83111, Iran.
  • Rezaei B; Department of Chemistry, Isfahan University of Technology, Isfahan, 84156-83111, Iran. rezaei@cc.iut.ac.ir.
  • Shahshahanipour M; Department of Chemistry, Isfahan University of Technology, Isfahan, 84156-83111, Iran.
  • Ensafi AA; Department of Chemistry, Isfahan University of Technology, Isfahan, 84156-83111, Iran.
  • Mohammadnezhad G; Department of Chemistry, Isfahan University of Technology, Isfahan, 84156-83111, Iran.
Anal Bioanal Chem ; 411(14): 3115-3124, 2019 May.
Article em En | MEDLINE | ID: mdl-30989266
ABSTRACT
A novel, sensitive, rapid, and simple fluorescent probe has been developed based on green-synthesized carbon dots (CDs). In this work, CDs have been synthesized from valerian root by hydrothermal method. Transmission electron microscopy (TEM) and dynamic light scattering (DLS) results confirm the formation of CDs with sizes of less than 10 nm. Fluorescence quenching of CDs was due to the aggregation of the negative charges of CDs with the positive charge of imipramine (IMI) and was then used as the signal for determination of IMI. In addition, the cytotoxicity of CDs was determined using the MTT assay. The probe responses under optimum conditions were linear in the range of 1.0-200.0 ng mL-1 with a limit of detection of 0.6 ng mL-1. Afterwards, mesoporous boehmite (MB) was modified with synthesized CDs (CDs/MB). TEM images confirmed MB modification with CDs. In this case, the variations in the fluorescence signal for different concentrations of IMI increased leading to the higher sensitivity for IMI detection. The limit of detection and linear range for determination of IMI with CDs/MB were obtained as 0.2 and 0.5-200.0 ng mL-1, respectively. To evaluate the fluorescent probe, IMI was measured in real samples. Graphical abstract.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Valeriana / Carbono / Raízes de Plantas / Química Verde / Hidróxido de Alumínio / Óxido de Alumínio / Corantes Fluorescentes / Imipramina / Antidepressivos Tricíclicos Limite: Humans Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Valeriana / Carbono / Raízes de Plantas / Química Verde / Hidróxido de Alumínio / Óxido de Alumínio / Corantes Fluorescentes / Imipramina / Antidepressivos Tricíclicos Limite: Humans Idioma: En Ano de publicação: 2019 Tipo de documento: Article