Your browser doesn't support javascript.
loading
Portable detection of colorectal cancer SW620 cells by using a personal glucose meter.
Zhou, Jun; Duan, Lunxi; Huang, Jiangsheng; Zuo, Zhongkun; Tang, Tenglong; Cao, Ding; Ye, Fei; Zhou, Shiwei; Zhou, Yueying; Zhang, Leiyi.
Afiliação
  • Zhou J; Department of Minimally Invasive Surgery, The Second Xiangya Hospital, Xiangya Stomatological Hospital, Central South University, Changsha, Hunan, PR China.
  • Duan L; Department of Minimally Invasive Surgery, The Second Xiangya Hospital, Xiangya Stomatological Hospital, Central South University, Changsha, Hunan, PR China.
  • Huang J; Department of Minimally Invasive Surgery, The Second Xiangya Hospital, Xiangya Stomatological Hospital, Central South University, Changsha, Hunan, PR China.
  • Zuo Z; Department of Minimally Invasive Surgery, The Second Xiangya Hospital, Xiangya Stomatological Hospital, Central South University, Changsha, Hunan, PR China.
  • Tang T; Department of Minimally Invasive Surgery, The Second Xiangya Hospital, Xiangya Stomatological Hospital, Central South University, Changsha, Hunan, PR China.
  • Cao D; Department of Minimally Invasive Surgery, The Second Xiangya Hospital, Xiangya Stomatological Hospital, Central South University, Changsha, Hunan, PR China.
  • Ye F; Department of Minimally Invasive Surgery, The Second Xiangya Hospital, Xiangya Stomatological Hospital, Central South University, Changsha, Hunan, PR China.
  • Zhou S; Department of Minimally Invasive Surgery, The Second Xiangya Hospital, Xiangya Stomatological Hospital, Central South University, Changsha, Hunan, PR China.
  • Zhou Y; Department of Minimally Invasive Surgery, The Second Xiangya Hospital, Xiangya Stomatological Hospital, Central South University, Changsha, Hunan, PR China.
  • Zhang L; Department of Minimally Invasive Surgery, The Second Xiangya Hospital, Xiangya Stomatological Hospital, Central South University, Changsha, Hunan, PR China. Electronic address: zhangleiyi@csu.edu.cn.
Anal Biochem ; 577: 110-116, 2019 07 15.
Article em En | MEDLINE | ID: mdl-31034799
It is of great value to develop general, low-cost and even household methods for colorectal cancer detection. Here, a portable detection strategy based on a personal glucose meter (PGM) was designed for meeting this purpose. In this strategy, the anti-EpCAM coated magnet beads (MBs) were used as capture probes for enriching cancer cells and the aptamer modified and invertase loaded graphene oxides (GO) were used as report probes for producing glucose signal. This method is sensitive with detection limit as low as 560 cells, and demonstrates excellent detection specificity. Meanwhile, we succeeded in the specific detection of target cells in 20% human serum samples, indicating this method has great prospect in clinical diagnosis. Moreover, this method presents favourable universality for detecting different colorectal cancer cells by just using different recognition aptamers. Importantly, this method can be implemented for the target cell detection at room temperature without any expensive and large-scale instruments but a portable PGM. Therefore, this portable detection method possesses great potential in point-of-care detection of colorectal cancer cells.