Your browser doesn't support javascript.
loading
The natural matching of harmonic responses in the pulmonary circulation.
Pérez Del Villar, Candelas; Martínez-Legazpi, Pablo; Mombiela, Teresa; Chazo, Christian; Desco, Mar; Rodríguez-Pérez, Daniel; Benito, Yolanda; Barrio, Alicia; Gutiérrez-Ibañes, Enrique; Del Álamo, Juan C; Elízaga, Jaime; Antoranz, José Carlos; Fernández-Avilés, Francisco; Yotti, Raquel; Bermejo, Javier.
Afiliação
  • Pérez Del Villar C; Department of Cardiology, Hospital General Universitario Gregorio Marañón; Facultad de Medicina, Universidad Complutense de Madrid; Instituto de Investigación Sanitaria Gregorio Marañón; and CIBERCV, Instituto de Salud Carlos III, Madrid, Spain.
  • Martínez-Legazpi P; Department of Cardiology, Hospital General Universitario Gregorio Marañón; Facultad de Medicina, Universidad Complutense de Madrid; Instituto de Investigación Sanitaria Gregorio Marañón; and CIBERCV, Instituto de Salud Carlos III, Madrid, Spain.
  • Mombiela T; Department of Cardiology, Hospital General Universitario Gregorio Marañón; Facultad de Medicina, Universidad Complutense de Madrid; Instituto de Investigación Sanitaria Gregorio Marañón; and CIBERCV, Instituto de Salud Carlos III, Madrid, Spain.
  • Chazo C; Department of Cardiology, Hospital General Universitario Gregorio Marañón; Facultad de Medicina, Universidad Complutense de Madrid; Instituto de Investigación Sanitaria Gregorio Marañón; and CIBERCV, Instituto de Salud Carlos III, Madrid, Spain.
  • Desco M; Department of Mathematical Physics and Fluids, Facultad de Ciencias, Universidad Nacional de Educación a Distancia, Madrid, Spain.
  • Rodríguez-Pérez D; Department of Mathematical Physics and Fluids, Facultad de Ciencias, Universidad Nacional de Educación a Distancia, Madrid, Spain.
  • Benito Y; Department of Cardiology, Hospital General Universitario Gregorio Marañón; Facultad de Medicina, Universidad Complutense de Madrid; Instituto de Investigación Sanitaria Gregorio Marañón; and CIBERCV, Instituto de Salud Carlos III, Madrid, Spain.
  • Barrio A; Department of Cardiology, Hospital General Universitario Gregorio Marañón; Facultad de Medicina, Universidad Complutense de Madrid; Instituto de Investigación Sanitaria Gregorio Marañón; and CIBERCV, Instituto de Salud Carlos III, Madrid, Spain.
  • Gutiérrez-Ibañes E; Department of Cardiology, Hospital General Universitario Gregorio Marañón; Facultad de Medicina, Universidad Complutense de Madrid; Instituto de Investigación Sanitaria Gregorio Marañón; and CIBERCV, Instituto de Salud Carlos III, Madrid, Spain.
  • Del Álamo JC; Mechanical and Aerospace Engineering Department, University of California San Diego, and the Institute for Engineering in Medicine, University of California San Diego, La Jolla, CA, USA.
  • Elízaga J; Department of Cardiology, Hospital General Universitario Gregorio Marañón; Facultad de Medicina, Universidad Complutense de Madrid; Instituto de Investigación Sanitaria Gregorio Marañón; and CIBERCV, Instituto de Salud Carlos III, Madrid, Spain.
  • Antoranz JC; Department of Mathematical Physics and Fluids, Facultad de Ciencias, Universidad Nacional de Educación a Distancia, Madrid, Spain.
  • Fernández-Avilés F; Department of Cardiology, Hospital General Universitario Gregorio Marañón; Facultad de Medicina, Universidad Complutense de Madrid; Instituto de Investigación Sanitaria Gregorio Marañón; and CIBERCV, Instituto de Salud Carlos III, Madrid, Spain.
  • Yotti R; Department of Cardiology, Hospital General Universitario Gregorio Marañón; Facultad de Medicina, Universidad Complutense de Madrid; Instituto de Investigación Sanitaria Gregorio Marañón; and CIBERCV, Instituto de Salud Carlos III, Madrid, Spain.
  • Bermejo J; Department of Cardiology, Hospital General Universitario Gregorio Marañón; Facultad de Medicina, Universidad Complutense de Madrid; Instituto de Investigación Sanitaria Gregorio Marañón; and CIBERCV, Instituto de Salud Carlos III, Madrid, Spain.
J Physiol ; 597(15): 3853-3865, 2019 08.
Article em En | MEDLINE | ID: mdl-31187875
ABSTRACT
KEY POINTS The right ventricle of the mammal heart is highly sensitive to the afterload imposed by a combination of the pulmonary circulation and the retrograde contribution of the left heart. Right ventricular afterload can be analysed in terms of pulmonary artery input impedance, which we were able to decompose as the result of the harmonic frequency responses of the pulmonary vessels and the left heart attached in series. Using spectral methods, we found a natural matching between the pulmonary vasculature and the left chambers of the heart. This coupling implies that the upstream transmission of the left heart frequency-response has favourable effects on the pulmonary tree. This physiological mechanism protects the right ventricle against acute changes in preload, and its impairment may be a relevant contribution to right ventricle dysfunction in pulmonary hypertension. ABSTRACT The right ventricle (RV) of the mammal heart is highly sensitive to the afterload imposed by the pulmonary circulation, and the left heart (LH) retrogradely contributes significantly to this vascular load. Transmission-line theory anticipates that the degree of matching between the frequency responses of the pulmonary vasculature and the LH should modulate the global right haemodynamic burden. We measured simultaneous high-fidelity flow (pulmonary artery) and pressure (pulmonary artery and left atrium) in 18 healthy minipigs under acute haemodynamic interventions. From these data, we decomposed the impedance spectra of the total right-circulation system into the impedance of the pulmonary vessels and the harmonic response of the LH. For frequencies above the first harmonic, total impedance was below the pulmonary impedance during all phases (P < 0.001; pooled phases), demonstrating a favourable effect of the LH harmonic response on RV pulsatile load the LH harmonic response was responsible for a 20% reduction of pulse pulmonary artery pressure (P < 0.001 vs. a theoretical purely-resistive response) and a 15% increase of pulmonary compliance (P = 0.009). This effect on compliance was highest during acute volume overload. In the normal right circulation, the longitudinal impedance of the pulmonary vasculature is matched to the harmonic response of the LH in a way that efficiently reduces the pulmonary pulsatile vascular load. This source of interaction between the right and left circulations of mammals protects the RV against excessive afterload during acute volume transients and its disruption may be an important contributor to pulmonary hypertension.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Circulação Pulmonar / Hemodinâmica / Modelos Cardiovasculares Limite: Animals Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Circulação Pulmonar / Hemodinâmica / Modelos Cardiovasculares Limite: Animals Idioma: En Ano de publicação: 2019 Tipo de documento: Article