Your browser doesn't support javascript.
loading
A low-cost portable system for elemental mapping by XRF aiming in situ analyses.
Campos, P H O V; Appoloni, C R; Rizzutto, M A; Leite, A R; Assis, R F; Santos, H C; Silva, T F; Rodrigues, C L; Tabacniks, M H; Added, N.
Afiliação
  • Campos PHOV; Instituto de Física, Universidade de São Paulo, Rua do Matão, Trav. R, 187, 05508-090, São Paulo, Brazil; Departamento de Física, Centro de Ciências Exatas, Universidade Estadual de Londrina, Londrina, Brazil. Electronic address: pcampos@usp.br.
  • Appoloni CR; Departamento de Física, Centro de Ciências Exatas, Universidade Estadual de Londrina, Londrina, Brazil.
  • Rizzutto MA; Instituto de Física, Universidade de São Paulo, Rua do Matão, Trav. R, 187, 05508-090, São Paulo, Brazil.
  • Leite AR; Instituto de Física, Universidade de São Paulo, Rua do Matão, Trav. R, 187, 05508-090, São Paulo, Brazil.
  • Assis RF; Instituto de Física, Universidade de São Paulo, Rua do Matão, Trav. R, 187, 05508-090, São Paulo, Brazil.
  • Santos HC; Instituto de Física, Universidade de São Paulo, Rua do Matão, Trav. R, 187, 05508-090, São Paulo, Brazil.
  • Silva TF; Instituto de Física, Universidade de São Paulo, Rua do Matão, Trav. R, 187, 05508-090, São Paulo, Brazil.
  • Rodrigues CL; Instituto de Física, Universidade de São Paulo, Rua do Matão, Trav. R, 187, 05508-090, São Paulo, Brazil.
  • Tabacniks MH; Instituto de Física, Universidade de São Paulo, Rua do Matão, Trav. R, 187, 05508-090, São Paulo, Brazil.
  • Added N; Instituto de Física, Universidade de São Paulo, Rua do Matão, Trav. R, 187, 05508-090, São Paulo, Brazil.
Appl Radiat Isot ; 152: 78-85, 2019 Oct.
Article em En | MEDLINE | ID: mdl-31280111
ABSTRACT
This work presents the development of a portable system that allows 2D elemental mapping of large areas (maximum of 35.0 × 35.0 cm2) by XRF. A measuring head, composed of an x-ray source and a detector, is mounted on a 3-axis stage with movement reproducibility better that 0.03 mm. The final elemental map resolution of 1.4 mm was experimentally determined in the best condition of collimation, and the same experiments indicate that the resolution is fully dominated by the x-ray beam spot size. The main goal of this new setup is to perform analyses of historical, archaeological and geological objects. Because it's lightweight, our setup has the potential to be of great utility for in situ analyses, given the great difficulty and high costs transporting the artifacts from the museum to a laboratory. The importance of this instrumentation is related to the need to identify the distribution of the chemical elements in large surface areas of cultural heritage objects by a nondestructive method.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Health_economic_evaluation / Prognostic_studies Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Health_economic_evaluation / Prognostic_studies Idioma: En Ano de publicação: 2019 Tipo de documento: Article